Cheat sheet

ARRT Limited Scope Cheat Sheet

Practice this exam

Patient Care

  • 18% of exam
  • Identity Consent HIPAA Infection Control Emergencies

Safety

  • 40% of exam
  • Radiation Physics ALARA Dose Units Shielding Scatter

Image Production

  • 42% of exam
  • Technique Image Quality Digital Imaging Equipment QA

Procedure Modules

  • 20-25% of exam
  • Chest Extremities Skull/Sinuses Spine Podiatric

Quick Facts

  • Exam Limited Scope
  • Owner ARRT/state agencies
  • Core 100 scored
  • Pilots Core +15
  • Modules State assigned
  • Core time 1h 55m
  • Fee $150
  • Pass State-determined 75

Identifier vs Room PA

Identifier

  • Name/DOB
  • Matches order
  • Patient-specific

Room

  • Location only
  • Can change
  • Never enough
  • Verify the person

Patient Action Picker PA

  • Patient refuses → Stop exam ( Document )
  • Wrong identity → Reverify ( Two IDs )
  • Pulseless patient → CPR/AED ( Activate help )
  • Airway reaction → Emergency response ( Oxygen/epi )
  • Contact isolation → Gown/gloves ( Before entry )
  • Catheter transfer → Bag below ( Closed system )
  • Pregnancy question → Follow policy ( Protect fetus )
  • Order mismatch → Clarify order ( Before exposure )

Patient Rights PA

  • Two identifiers Name plus DOB
  • Consent Permission for care
  • Refusal Stop and document
  • HIPAA Protect PHI
  • Battery Unauthorized touching
  • Negligence Care below standard
  • Respondeat Employer liability
  • Res ipsa Thing speaks

Sterile vs Aseptic PA

Sterile

  • No microorganisms
  • Sterile field
  • Surgical asepsis

Aseptic

  • Reduce microbes
  • Clean technique
  • Break transmission
  • Eliminate vs reduce

Infection + Emergency PA

  • Hand hygiene Before/after contact
  • Standard Every patient
  • Contact Gown + gloves
  • Droplet Mask close contact
  • Airborne N95 isolation
  • Asepsis Reduce microbes
  • Sterile No microorganisms
  • CPR/AED Pulseless response
  • Contrast airway Emergency reaction

ALARA SA

  • ALARA: time distance shielding
  • Time Distance Shielding Collimation

Deterministic vs Stochastic SA

Deterministic

  • Threshold
  • Severity increases
  • Tissue reaction

Stochastic

  • No threshold
  • Probability increases
  • Cancer risk
  • Severity vs chance

Radiation Physics SA

  • Thermionic Electron release
  • Bremsstrahlung Braking radiation
  • Characteristic Shell transition
  • Primary beam Useful x-rays
  • Remnant beam Exit radiation
  • Photoelectric Absorption interaction
  • Compton Scatter interaction
  • Attenuation Beam reduction
  • Gy Absorbed dose
  • Sv Dose equivalent

Grid vs Collimation SA

Grid

  • Absorbs scatter
  • Improves contrast
  • May raise dose

Collimation

  • Limits field
  • Lowers scatter
  • Protects patient
  • Clean vs restrict

Radiation Protection SA

  • ALARA Keep dose low
  • Time Shorter exposure
  • Distance Inverse square
  • Shielding Barrier attenuation
  • Collimation Restrict beam
  • Filtration Remove low energy
  • Dosimeter Personnel monitor
  • Pregnancy Follow policy
  • Scatter Patient source
  • DAP Dose-area product

Technique IM

  • mAs quantity; kVp quality
  • mAs kVp EI Noise

kVp vs mAs IM

kVp

  • Beam quality
  • Contrast effect
  • Penetration

mAs

  • Beam quantity
  • Receptor exposure
  • Noise control
  • Quality vs quantity

Image Correction Picker IM

  • Quantum noise → Increase exposure ( More signal )
  • Motion blur → Shorter time ( Immobilize )
  • Magnification → Lower OID ( Increase SID )
  • Shape distortion → Align part ( Reduce angle )
  • Scatter fog → Collimate/grid ( Clean contrast )
  • Rotation error → Reposition ( Check landmarks )
  • Anatomy clipped → Repeat view ( Include anatomy )
  • Wrong marker → Correct marker ( Legal ID )

Technique Factors IM

  • kVp Beam quality
  • mAs Beam quantity
  • 15% rule Doubles receptor exposure
  • SID Source distance
  • OID Object distance
  • Focal spot Detail control
  • Motion Blur source
  • Grid Scatter cleanup
  • AEC Automatic exposure
  • EI Exposure indicator

Geometry IM

  • SID up; OID down
  • Long SID Short OID Small focal No motion

SID vs OID IM

SID

  • Source distance
  • Longer reduces blur
  • Affects intensity

OID

  • Part distance
  • Shorter reduces magnification
  • Affects distortion
  • Far source, close part

Digital + QA IM

  • Pixel Image element
  • DEL Detector element
  • DQE Detector efficiency
  • SNR Signal/noise ratio
  • Histogram Exposure distribution
  • Artifact Unwanted image mark
  • Marker Side identification
  • Fog Unwanted exposure
  • Calibration Detector maintenance
  • Monitor QC Display quality

Core Counts PR

  • Core: PC=18 S=40 IP=42
  • Patient Care Safety Image Production

Position vs Projection PR

Position

  • Patient placement
  • Body orientation
  • Landmarks

Projection

  • Beam path
  • Entry/exit
  • CR direction
  • Body vs beam

Procedure Picker PR

  • State assigns chest → Chest module ( 20 scored )
  • Routine chest → PA/lateral ( Upright )
  • Fluid level → Decubitus ( Horizontal beam )
  • Extremity trauma → Modify views ( Do no harm )
  • Long bone → Include joints ( Both ends )
  • Sinus fluid → Erect view ( Shows levels )
  • C-spine trauma → No manipulation ( Stabilize )
  • Foot alignment → Weightbearing ( If ordered )

Procedure Modules PR

  • Chest 20 scored
  • Extremities 25 scored
  • Skull/Sinuses 20 scored
  • Spine 25 scored
  • Podiatric 20 scored
  • Each module Five pilots
  • CSR Assigned modules
  • State agency Sets eligibility

Positioning Hooks PR

  • PA chest Upright routine
  • Lateral chest Second routine view
  • Decubitus Air/fluid levels
  • Long bone Include joints
  • Oblique Unsuperimpose anatomy
  • C-spine Do not force
  • Sinuses Erect when possible
  • Weightbearing Podiatric comparison

Common Traps

Consent vs order

  • Order requests exam ≠ Consent permits care

Room vs patient

  • Room number moves ≠ Identifiers stay patient-specific

ALARA scope

  • Patient dose minimized ≠ ALARA names personnel

mAs vs kVp

  • mAs controls quantity ≠ kVp controls quality

Grid vs dose

  • Grid cleans scatter ≠ Grid may raise exposure

Position vs projection

  • Position is body ≠ Projection is beam

Pilot vs scored

  • Pilots are hidden ≠ Pace every item

Last Minute

  • 1. Confirm state modules
  • 2. Core has 100 scored
  • 3. Safety has 40 scored
  • 4. Image Production has 42
  • 5. Patient Care has 18
  • 6. Use two identifiers
  • 7. ALARA: time distance shielding
  • 8. kVp quality; mAs quantity
  • 9. 15% rule doubles exposure
  • 10. Never disclose exam items

ARRT Limited Scope of Practice in Radiography

  • Practice Questions 100 questions Study Guide 9 topics Cheat Sheet 73 facts Flashcards 50 cards Shorts 2 short s Videos 1 video Blogs 1 blog Free CE Podcast