Cheat sheet

ARRT Nuclear Medicine Technology (N) Cheat Sheet

Practice this exam

Patient Care

  • 12% of exam
  • Informed Consent HIPAA Standard Precautions Allergic Reactions

Safety

  • 12.5% of exam
  • Radiation Protection Cardinals NRC Dose Limits Posting & Area Classifications Survey & Dosimetry Instruments

Image Production

  • 16.5% of exam
  • Collimator Types Gamma Camera QC PET/CT & SPECT Terms Health IT & Informatics

Procedures

  • 59% of exam
  • Radionuclide Table Cardiac Procedures Endocrine & Oncology GI & GU Procedures Other Imaging Generator & Radiopharmacy QC

Quick Facts

  • Exam ARRT NMT (N)
  • Credential Nuclear Medicine Technology
  • Time 230 min (250 total)
  • Pass Scaled score 75
  • Fee $225
  • Questions 230 (200 scored)
  • Provider Pearson VUE
  • Blueprint Jan 1 2022

Patient Care Essentials PA

  • Informed consent Physician explains; tech witnesses
  • HIPAA minimum necessary Access only what's needed
  • Chain of infection 6 links; break one
  • Standard precautions All patients; PPE by exposure
  • Early allergy signs Urticaria, pruritus, flushing
  • Metformin and FDG PET Hold ~48h before scan

Cardinal Principles SA

  • Time, Distance, Shielding = ALARA
  • Time: minimize duration Distance: inverse square law Shielding: match radiation type ALARA: as low as achievable

Radiation Area vs High Radiation Area SA

Radiation Area

  • Over 5 mrem/hr
  • At 30 cm
  • Standard posting required

High Radiation Area

  • Over 100 mrem/hr
  • At 30 cm
  • Stricter access control
  • 20x higher threshold

Radiation Protection Cardinals SA

  • Time Minimize exposure duration
  • Distance Inverse square law falloff
  • Shielding Match material to radiation
  • ALARA As low as reasonably achievable
  • Deterministic effects Threshold dose; severity increases
  • Stochastic effects No threshold; only probability increases

NRC Dose Limits SA

  • Public -> Occupational -> Eye -> Skin
  • Public: 100 mrem/yr Occupational: 5 rem/yr Eye: 15 rem/yr Skin: 50 rem/yr

Photoelectric Effect vs Compton Scattering SA

Photoelectric

  • Low-energy photon absorbed
  • Ejects inner-shell electron
  • No scatter produced

Compton

  • Higher-energy photon interaction
  • Ejects outer-shell electron
  • Main source of scatter
  • Absorption vs scatter

NRC Dose Limits (10 CFR 20) SA

  • Occupational whole-body 5 rem (50 mSv)/year
  • Public dose limit 100 mrem (1 mSv)/year
  • Declared pregnant worker 500 mrem per gestation
  • Lens of eye 15 rem (150 mSv)/year
  • Skin extremities 50 rem (0.5 Sv)/year
  • Minor worker (under 18) 10% of adult limits

GM Counter vs Ionization Chamber SA

GM Counter

  • Highly sensitive
  • For low-level contamination
  • Saturates at high dose

Ion Chamber

  • Less sensitive
  • Accurate at high dose
  • For area, spill surveys
  • Low-level vs high dose-rate

Posting & Area Classifications SA

  • Radiation area Over 5 mrem/hr at 30cm
  • High radiation area Over 100 mrem/hr at 30cm
  • Very high radiation area Over 500 rad/hr at 1m
  • Restricted area Access controlled for protection
  • Controlled area Occupational dose is managed
  • Airborne radioactivity area Airborne concentration limits exceeded

Survey & Dosimetry Instruments SA

  • GM counter Low-level contamination; saturates high-dose
  • Ion chamber Higher dose rates; less sensitive
  • Well counter In vitro samples; high sensitivity
  • Thyroid probe In vivo uptake; collimated NaI
  • Pocket dosimeter Real-time direct-reading personal dose
  • TLD/OSL badge Cumulative personnel dose record

SPECT vs Planar IM

SPECT

  • 3D tomographic imaging
  • Multiple angle views
  • Better contrast resolution

Planar

  • 2D single view
  • Faster acquisition time
  • Whole-body screening
  • Depth vs speed

Image Artifact Troubleshooting IM

  • Cold or hot spot → Check PMT/crystal ( Recalibrate camera )
  • Nonuniform flood, edge packing → Reset energy window ( Off-peak photopeak )
  • Blurred edges, streaking → Repeat acquisition ( Patient motion )
  • Star-pattern artifact → High-energy collimator ( Septal penetration )
  • Ring artifact on SPECT → Update uniformity map ( Detector nonuniformity )
  • Missing outer body (PET/CT) → Extend CT field ( Truncation artifact )
  • Photopenic rim at edges → Re-register CT/PET ( Attenuation misalignment )
  • Diffuse extra-osseous uptake → Check free pertechnetate ( Poor labeling )

Collimator Types IM

  • Parallel-hole General purpose; no magnification
  • Pinhole Magnifies small superficial organs
  • Converging (fan-beam) Magnifies; smaller field size
  • Diverging Minifies; wider field coverage
  • LEHR Best resolution; longer scan time
  • ME/HE collimators For I-131, higher-energy isotopes

Gamma Camera QC IM

  • Uniformity (flood) Daily; extrinsic or intrinsic
  • Center of rotation Weekly; SPECT cameras only
  • Resolution/linearity Monthly; bar phantom test
  • Multi-window registration Quarterly; dual-isotope alignment check
  • Energy resolution Acceptance testing; annual verification

PET/CT & SPECT Terms IM

  • Attenuation correction CT density corrects photon loss
  • SUV Standardized uptake value; tumor metric
  • Coincidence detection Two 511 keV photons simultaneously
  • Iterative reconstruction OSEM; better noise than FBP
  • Filtered back projection (FBP) Older method; streak artifacts
  • CTAC artifact Metal, contrast, or motion misregistration
  • Matrix size Pixel grid; affects resolution

Health IT & Informatics IM

  • DICOM Transmits/stores medical images
  • HL7 Exchanges orders and reports
  • PACS Archives and displays images
  • RIS Scheduling, orders, and reporting

Half-Life Order PR

  • F-18 -> Tc-99m -> I-123 -> Mo-99
  • F-18: 110 min Tc-99m: 6 hours I-123: 13 hours Mo-99: 66 hours

Constancy vs Accuracy PR

Constancy

  • Daily check
  • Cs-137 reference source
  • Detects day-to-day drift

Accuracy

  • Install + annual check
  • NIST-traceable source
  • Confirms true activity
  • Drift check vs true value

Radiopharmaceutical Selection by Indication PR

  • Thyroid uptake or Graves → I-123 ( Oral capsule )
  • Thyroid ablation or therapy → I-131 ( High-dose therapy )
  • Myocardial perfusion imaging → Tc-99m sestamibi/tetrofosmin ( Or Tl-201 )
  • Bone metastases survey → Tc-99m MDP ( 3-phase for infection )
  • Acute cholecystitis workup → Tc-99m mebrofenin (HIDA) ( Nonvis at 60 min )
  • Parathyroid adenoma localization → Tc-99m sestamibi dual-phase ( Delayed washout )
  • Neuroendocrine tumor imaging → Ga-68 DOTATATE ( Replaced OctreoScan )
  • Pheochromocytoma or neuroblastoma → I-123 MIBG ( Block thyroid first )
  • GFR calculation needed → Tc-99m DTPA ( Glomerular filtration )
  • Poor renal function → Tc-99m MAG3 ( Tubular secretion )

Radionuclide Table PR

  • Tc-99m 6 h, 140 keV IT decay; workhorse agent
  • Mo-99 66 h, generator parent β⁻ decay to Tc-99m
  • I-123 13 h, 159 keV EC decay; diagnostic thyroid
  • I-131 8 d, 364 keV β⁻/γ; thyroid ablation
  • F-18 110 min, 511 keV β+ decay; PET FDG
  • Ga-67 78 h, 93/184/300 keV EC decay; infection, tumor
  • In-111 2.8 d, 171/245 keV EC decay; tumor, infection
  • Tl-201 73 h, 69-83/167 keV EC decay; cardiac perfusion
  • Xe-133 5.24 d, 81 keV β⁻/γ; lung ventilation
  • Lu-177 6.65 d, 208 keV β⁻ decay; PRRT, PSMA
  • Y-90 64 h, pure beta No primary gamma photon

Dose Calibrator QC PR

  • C-A-L-G: Constancy, Accuracy, Linearity, Geometry
  • Constancy: daily check Accuracy: install, annual Linearity: install, quarterly Geometry: install only

Linearity vs Geometry PR

Linearity

  • Across activity range
  • Install + quarterly
  • Catches nonlinear response

Geometry

  • Different volumes, containers
  • Install only
  • Catches volume-dependent error
  • Activity range vs container size

Pharmacologic Stress Agent Picker PR

  • Standard vasodilator stress needed → Regadenoson ( Fixed dose )
  • Reactive airway disease → Regadenoson preferred ( A2A selective )
  • AV block, no pacemaker → Avoid vasodilators ( Use dobutamine )
  • Recent caffeine or theophylline → Hold before vasodilator ( Antagonizes receptors )
  • Cannot exercise, no contraindication → Adenosine or dipyridamole ( Alternative vasodilators )
  • Vasodilator contraindicated → Dobutamine ( Inotrope, chronotrope )

Generator & Radiopharmacy QC PR

  • Mo-99 breakthrough ≤0.15 µCi/mCi Tc-99m
  • Al breakthrough ≤10 µg/mL eluate
  • Stannous ion Reduces Tc for labeling
  • Labeling efficiency Depends on pH, time, temp
  • Radiochemical purity (RCP) TLC measures unbound activity
  • Elution Saline extracts Tc-99m only

Thyroid Iodine Choice PR

  • I-123 diagnoses; I-131 treats
  • I-123: 13h imaging I-131: 8d therapy Low-iodine diet: before I-131 TSH stimulation required

Free vs Hydrolyzed-Reduced Tc PR

Free Pertechnetate

  • Unbound Tc-99m
  • Thyroid, stomach, salivary uptake
  • Signals poor labeling

Hydrolyzed-Reduced Tc

  • Under-reduced by stannous ion
  • Liver, spleen uptake
  • Colloid-like behavior
  • Both are labeling failures

Dose Calibrator QC PR

  • Constancy Daily, Cs-137 source
  • Accuracy Install + annual, NIST source
  • Linearity Install + quarterly, activity range
  • Geometry Install only, varied containers
  • Attenuators (liners) Match isotope energy range

Stress vs Rest Imaging PR

Stress

  • Pharmacologic or exercise
  • Reveals reversible ischemia
  • Usually acquired first

Rest

  • Baseline perfusion state
  • Confirms fixed defects
  • Redistribution comparison point
  • Compare for reversibility

Cardiac Procedures PR

  • Reversible defect Stress only; ischemic, viable
  • Fixed defect Stress and rest; scarred tissue
  • MUGA ECG-gated; ejection fraction calc
  • Sestamibi/tetrofosmin Mitochondrial uptake; no redistribution
  • Vasodilator stress Regadenoson, adenosine, or dipyridamole
  • Dobutamine Inotrope; used if contraindicated

MAG3 vs DTPA PR

MAG3

  • Tubular secretion
  • High extraction efficiency
  • Preferred, poor function

DTPA

  • Glomerular filtration
  • Calculates GFR
  • Normal renal function
  • Secretion vs filtration

Endocrine & Oncology Procedures PR

  • RAIU % uptake at set intervals
  • Parathyroid scan Dual-phase sestamibi; adenoma persists
  • Low-iodine diet Before I-131; maximizes uptake
  • MIBG Norepinephrine analog; neuroendocrine tumors
  • Ga-68 DOTATATE Somatostatin receptor; replaces OctreoScan
  • FDG prep Fast 4-6h; check glucose

In-111 Pentetreotide vs Ga-68 DOTATATE PR

In-111 Pentetreotide

  • Older SPECT agent
  • OctreoScan brand name

Ga-68 DOTATATE

  • Newer PET agent
  • Higher resolution imaging
  • Largely replaced by PET

GI & GU Procedures PR

  • Gastric emptying Solid meal; 4-hour protocol
  • Meckel scan Pertechnetate; ectopic gastric mucosa
  • HIDA scan No gallbladder by 60 min
  • GI bleed scan Tagged RBCs; detects slow bleeds
  • MAG3 Tubular secretion; poor renal function
  • DTPA renal Glomerular filtration; calculates GFR

Other Imaging Procedures PR

  • 3-phase bone scan Flow, blood pool, delayed
  • Brain death study No flow; hollow skull sign
  • MAA lung perfusion Microembolizes capillaries; reduce dose caution
  • Xe-133 ventilation True gas; closed delivery system
  • DTPA aerosol Nebulized; uneven obstructed deposition
  • Sentinel node mapping Sulfur colloid; first-draining node
  • Cisternography/shunt patency CSF flow; confirms patency, leaks

Common Traps

Constancy vs Accuracy

  • Constancy checks daily drift ≠ Accuracy confirms true activity value

Radiation Area vs High Radiation Area

  • 5 mrem/hr threshold ≠ 100 mrem/hr threshold

Free vs Bound Pertechnetate

  • Free causes thyroid, stomach uptake ≠ Bound stays on kit ligand

Reversible vs Fixed Defect

  • Reversible resolves at rest ≠ Fixed persists at rest too

I-123 vs I-131 Use

  • I-123 is for diagnosis ≠ I-131 is for therapy

GM Counter vs Ion Chamber

  • GM for low-level survey work ≠ Chamber for high dose rates

Deterministic vs Stochastic Effects

  • Deterministic has a dose threshold ≠ Stochastic has no dose threshold

Last Minute

  • 1. Tc-99m: 6h, 140 keV
  • 2. F-18: 110 min, 511 keV
  • 3. I-123 diagnoses; I-131 treats
  • 4. Occupational 5 rem; public 100 mrem
  • 5. Radiation Area = 5 mrem/hr
  • 6. Medical event: 20% + threshold rem
  • 7. Mo-99 breakthrough ≤0.15 µCi/mCi
  • 8. Constancy daily; accuracy install + annual
  • 9. MAG3 = poor function; DTPA = GFR
  • 10. SPECT 180° arc for cardiac
  • 11. Free pertechnetate = poor labeling
  • 12. Y-90 = pure beta, no gamma

ARRT Nuclear Medicine

  • Practice Questions 270 questions Study Guide 36 topics Cheat Sheet 99 facts Flashcards 50 cards Videos 1 video Blogs 1 blog Free CE Podcast