Cheat sheet
BCSP ASP Cheat Sheet
Mathematical Calculations
- 10% of exam
- Core Formulas Exposure Math Unit Conversions Calculation Picker
Safety Programs
- 25% of exam
- Safety Systems Hazard Analysis Controls Program Picker
Ergonomics
- 8% of exam
- Ergo Factors Ergo Tools NIOSH Lift Work Design
Fire Protection
- 12% of exam
- Fire Science Fire Controls Extinguishers Bonding vs Grounding
Emergency Response
- 10% of exam
- Emergency Planning ICS Roles Exercise Picker Mutual Aid
Industrial Hygiene
- 12% of exam
- IH Limits Routes IH Program Exposure Limits
Environmental Management
- 7% of exam
- Environmental Rules Waste P2 ESG
Training + Communication
- 11% of exam
- Training Design Culture Competence Human Factors
Legal
- 5% of exam
- Legal Risk Records Risk Transfer Scope Limits
Quick Facts
- Exam BCSP ASP
- Credential Associate Safety Professional
- Questions 200 MCQ
- Time 5 hours
- Delivery Pearson VUE
- Book Closed book
- Eligibility Degree + 1 year
- Exam fee $350
- Blueprint ASP11
Calculation Picker MA
- Tank capacity → Volume formula ( Geometry )
- Noise shift → Dose/TWA ( Log math )
- Incident trend → TRIR/DART ( 200000 base )
- Manual lift → NIOSH equation ( RWL/LI )
- Radiation distance → Inverse square ( Intensity )
- Rigging angle → Vector tension ( Leg load )
- Ventilation flow → Flow rate ( CFM )
- Financial choice → Cost-benefit ( ROI )
Core Formulas MA
- Cylinder volume pi r2 h
- TRIR Cases x200000 / hours
- DART DART x200000 / hours
- EMR Actual / expected losses
- Ohm law V = I R
- Power P = V I
- Force Mass x acceleration
- Momentum Mass x velocity
Exposure Math MA
- TWA Time-weighted average
- STEL Short-term limit
- Ceiling Never exceed
- Dose Sum C over T
- Half-life Half activity time
- Inverse square Distance cuts intensity
- Heat index Temperature plus humidity
- Wind chill Cold plus wind
Controls Order PR
- Eliminate, substitute, engineer, admin, PPE
- E: remove S: replace E: isolate A: procedure PPE: person
Leading vs Lagging PR
Leading
- Before incidents
- Activities
- Predictive
Lagging
- After incidents
- Outcomes
- Historical
- Preventive vs reactive
Program Picker PR
- Task hazards → JHA ( Step review )
- Failure ranking → FMEA ( RPN )
- Top event → FTA ( Logic gates )
- Unknown scenario → What-if ( Prompts )
- Process change → MOC ( Pre-change )
- Restart process → PSSR ( Pre-startup )
- Chemical labels → GHS ( HazCom )
- Energy service → LOTO ( Isolation )
Safety Systems PR
- ISO 45001 OHSMS standard
- ANSI Z10 US OHSMS standard
- PDCA Plan do check act
- Hierarchy Controls ranked
- Leading Preventive activity metric
- Lagging Incident outcome metric
- MOC Change risk control
- PSSR Startup readiness check
MOC vs PSSR PR
MOC
- Review change
- Before modification
- Risk approval
PSSR
- Verify readiness
- Before startup
- Training complete
- Change approval vs startup check
Hazard Analysis PR
- JHA Task hazard steps
- FMEA Failure mode ranking
- RPN Severity x occurrence x detection
- FTA Top-down fault logic
- What-if Scenario questions
- Checklist Known hazard prompts
- Fishbone Cause categories
- Risk matrix Likelihood x severity
JHA vs FMEA PR
JHA
- Task steps
- Job hazards
- Controls
FMEA
- Failure modes
- RPN ranking
- Design/process
- Task vs failure
Controls PR
- Elimination Remove hazard
- Substitution Safer replacement
- Engineering Isolate people
- Administrative Change work method
- PPE Protect worker
- LOTO Control hazardous energy
- Confined space Permit when hazardous
- GHS Chemical hazard communication
Ergo Factors ER
- Force High exertion
- Repetition Repeated motions
- Awkward posture Joint deviation
- Static posture Held position
- Contact stress Localized pressure
- Vibration Tool or whole-body
- Temperature Cold or heat
- Lighting Visual strain
Ergo Tools ER
- NIOSH Lift Manual lifting screen
- RWL Recommended weight limit
- LI Load / RWL
- REBA Whole-body posture
- RULA Upper-limb posture
- Anthropometry Human body dimensions
- Job rotation Exposure sharing
- Hoist Engineering lift control
Fire Classes FI
- A ash, B boil, C current
- A: solids B: liquids C: energized D: metals K: kitchen
Bonding vs Grounding FI
Bonding
- Connect objects
- Equal potential
- Static transfer
Grounding
- Connect earth
- Dissipate charge
- Fault path
- Equalize vs dissipate
Fire Science FI
- Triangle Heat fuel oxygen
- Tetrahedron Adds chain reaction
- LEL Too lean below
- UEL Too rich above
- Flash point Ignitable vapor temperature
- Autoignition Ignites without spark
- Combustible dust Fine fuel explosion
- Hot work Ignition-producing work
Fire Controls FI
- Class A Ordinary combustibles
- Class B Flammable liquids
- Class C Energized electrical
- Class D Combustible metals
- Class K Cooking oils
- Sprinkler Automatic water control
- Bonding Equalize potential
- Grounding Dissipate charge
ICS Sections EM
- Operations plans, logistics supplies, finance pays
- Ops: tactics Planning: information Logistics: resources Finance: costs
Tabletop vs Full-Scale EM
Tabletop
- Discussion
- Low cost
- Plan review
Full-scale
- Deployment
- High realism
- Field resources
- Talk through vs act out
Exercise Picker EM
- Discussion only → Tabletop ( Low disruption )
- Operations center → Functional ( Simulated response )
- Field deployment → Full-scale ( Real resources )
- Evacuation route → Drill ( Practice movement )
- External resources → Mutual aid ( Partner support )
- Media message → PIO ( Approved release )
Emergency Planning EM
- ERP Response roles and actions
- EAP Evacuation and accountability
- ICS Incident command system
- IAP Incident action plan
- BCP Business continuity plan
- Mutual aid Shared emergency resources
- Lone worker Isolation risk control
- Workplace violence Threat prevention program
ICS Roles EM
- IC Overall command
- PIO Public information
- Safety Officer Responder safety
- Liaison Agency coordination
- Operations Tactical response
- Planning Information and resources
- Logistics Facilities and supplies
- Finance Costs and procurement
Exposure Limits IH
- TWA shift, STEL short, ceiling never
- TWA: average STEL: 15 min Ceiling: cap IDLH: escape
TWA vs STEL IH
TWA
- Full shift
- Average exposure
- Chronic concern
STEL
- Short duration
- Peak exposure
- Acute concern
- Shift average vs peak
IH Limits IH
- PEL OSHA legal limit
- TLV ACGIH guidance limit
- REL NIOSH recommended limit
- IDLH Immediate life threat
- TWA Full-shift average
- STEL Fifteen-minute average
- Ceiling Instant cap
- OEL Exposure limit family
Routes IH
- Inhalation Breathe contaminant
- Absorption Skin uptake
- Ingestion Swallow contaminant
- Injection Puncture entry
- Acute Short exposure effect
- Chronic Long exposure effect
- Target organ Affected body system
- Universal precautions Treat blood infectious
Environmental Rules EN
- ISO 14001 Environmental management system
- SPCC Oil spill prevention
- EPCRA Emergency chemical reporting
- Tier II Chemical inventory report
- Manifest Waste tracking form
- Cradle-to-grave Generator responsibility
- P2 Pollution prevention
- ESG Environmental social governance
Competent vs Qualified TR
Competent
- Identify hazards
- Authority
- Corrective action
Qualified
- Training/degree
- Knowledge
- Demonstrated ability
- Authority vs expertise
Training Design TR
- Needs analysis Find training gaps
- Task analysis Break job steps
- Baseline competency Starting skill level
- Objective Measurable performance target
- JIT Before-task training
- Retention Knowledge kept
- Effectiveness Training changed behavior
- Feedback Worker input loop
Legal Risk LE
- Compliance Meet legal requirements
- Liability Legal responsibility
- Contractor Shared site exposure
- Multi-employer Multiple duty holders
- Records Controlled evidence
- Chain custody Evidence handling trail
- Privacy Worker data limits
- Risk transfer Insurance or contract
Common Traps
Eligibility duty
- One safety year ≠ At least 50%
Blueprint weight
- Programs largest ≠ Legal smallest
Control ranking
- Elimination strongest ≠ PPE weakest
MOC timing
- MOC before change ≠ PSSR before startup
Exposure limits
- TWA averages ≠ Ceiling caps
Fire electrical
- Class C energized ≠ Class B liquids
ICS confusion
- Ops acts ≠ Planning tracks
Legal scope
- Know limits ≠ Escalate specialists
Last Minute
- 1. Domain 2 = 25%
- 2. ASP11 effective September 1 2025
- 3. 200 MCQ; 5 hours; closed book
- 4. Degree plus one safety year
- 5. Application $160; exam $350
- 6. Programs = largest domain
- 7. Eliminate before PPE
- 8. JHA = task; FMEA = failure
- 9. MOC before change; PSSR before startup
- 10. TWA average; ceiling never exceed
- 11. Class C = energized electrical
- 12. Competent = authority plus hazard recognition
- 13. Records need chain of custody
- 14. Pearson scheduling through BCSP profile
BCSP ASP
- Practice Questions 200 questions Study Guide 74 topics Cheat Sheet 128 facts Flashcards 50 cards Shorts 7 short s Videos 1 video Blogs 1 blog 1 Job Wiki Free CE