Cheat sheet

BICSI Technician Cheat Sheet

Practice this exam

Copper Cabling

  • 25% of exam
  • Cat 5e/6/6A specs T568A/B color order Twisted pair Distance limits Termination blocks

Optical Fiber

  • 25% of exam
  • Singlemode vs multimode OM1-OM5 bandwidth Wavelengths 850/1310/1550 Connector types Splice loss

Termination and Connectors

  • 10% of exam
  • RJ45 pinout 110/Krone/BIX blocks LC/SC/ST/MTP Polish types Cable prep

Testing and Certification

  • 10% of exam
  • OTDR traces TDR copper NVP Loss budgets Certification scanners

Codes and Standards

  • 5% of exam
  • TIA-568 TIA-607 bonding TIA-562 NEC/NFPA TSB bulletins

Grounding, Bonding, Firestopping

  • 15% of exam
  • TBB #6 AWG TMGB/TGB F/T/L/W ratings Penetration seals NEC compliance

Pathways and Spaces

  • 5% of exam
  • Conduit fill Cable trays Sleeves TR/TEF spaces Bend radius

Safety

  • 5% of exam
  • PPE Lockout/tagout Ladder safety Fiber shards Laser eye safety

Project and Documentation

  • 5% of exam
  • As-built drawings Test reports Warranty Coordination Blueprint reading

Quick Facts

  • Exam BICSI TECH
  • Questions 100 MCQ
  • Time 2 hours
  • Pass Scaled score
  • Hands-On 12 tasks
  • Task Time 20 min each
  • Fee $200+
  • Validity 3 years
  • Retake 30 days

T568A Color Order CO

  • WGrn Grn WOrg Blu WBlu Org WBrn Brn
  • Pin1 WGrn Pin3 WOrg Pin6 Org

T568A vs T568B CO

T568A

  • WGrn first
  • Residential
  • US gov

T568B

  • Worg first
  • Commercial
  • Most common
  • Orange/green swap

Copper Category Picker CO

  • Up to 1GbE → Cat 5e ( 100 MHz )
  • Up to 5GbE → Cat 6 ( 250 MHz )
  • 10GbE 55m → Cat 6 ( 37-55m )
  • 10GbE 100m → Cat 6A ( 500 MHz )
  • 25/40GbE 30m → Cat 8 ( 2000 MHz )
  • Noisy environment → S/FTP Cat 6A ( Shielded )

Copper Categories CO

  • Cat 5e 100 MHz, 1GbE 100MHz
  • Cat 6 250 MHz, 5GbE 250MHz
  • Cat 6A 500 MHz, 10GbE 500MHz
  • Cat 8 2000 MHz, 25/40GbE 2GHz
  • UTP Unshielded twisted pair
  • F/UTP Foil over twisted pairs
  • S/FTP Braid + foil pairs
  • AWG 22-24 Typical conductor gauge

Cat 6 vs Cat 6A CO

Cat 6

  • 250 MHz
  • 10GbE 55m
  • UTP common

Cat 6A

  • 500 MHz
  • 10GbE 100m
  • Alien crosstalk
  • Freq and distance

Copper Distance Limits CO

  • Channel 100 m max 100m
  • Permanent Link 90 m max 90m
  • Equipment Cord 5 m each end 5m
  • Work Area Cord 5 m max 5m
  • CP Cord 5 m max 5m
  • Total Cords 10 m combined

Permanent Link vs Channel CO

Permanent Link

  • 90 m
  • Excludes cords
  • Tester adapter

Channel

  • 100 m
  • Includes cords
  • Full end-to-end
  • Tester setup

T568A/B Color Order CO

  • T568A Pin 1 White/Green
  • T568A Pin 2 Green
  • T568A Pin 3 White/Orange
  • T568A Pin 4 Blue
  • T568A Pin 5 White/Blue
  • T568A Pin 6 Orange
  • T568A Pin 7 White/Brown
  • T568A Pin 8 Brown
  • T568B Swap orange/green pairs

OM Fiber 10GbE Distance FI

  • OM1 33m OM2 82m OM3 300m OM4 400m
  • OM1 62.5um 33m OM3 laser 300m OM4 400m

Singlemode vs Multimode FI

Singlemode

  • 9um core
  • One path
  • Long haul km

Multimode

  • 50/62.5um core
  • Multiple paths
  • Short m
  • Distance vs cost

Fiber Type Picker FI

  • Long haul >10km → OS2 ( 9um 1310/1550 )
  • 10GbE 33m → OM1 ( 62.5um )
  • 10GbE 82m → OM2 ( 50um )
  • 10GbE 300m → OM3 ( laser optimized )
  • 10GbE 400m → OM4 ( VCSEL )
  • 40/100GbE short → OM4/OM5 ( MTP parallel )

Fiber Types FI

  • OS1 Singlemode indoor, 1310/1550 9um
  • OS2 Singlemode low-water, 1310/1550 9um
  • OM1 62.5 um, 10GbE 33m 62.5um
  • OM2 50 um, 10GbE 82m 50um
  • OM3 50um laser, 10GbE 300m 50um
  • OM4 50um, 10GbE 400m 50um
  • OM5 WBMMF, 4x WDM 50um
  • Core/Clad 9/125, 50/125, 62.5/125

Fusion vs Mechanical FI

Fusion

  • Arc weld
  • ~0.05 dB loss
  • Permanent

Mechanical

  • Adhesive sleeve
  • 0.1-0.3 dB
  • Field quick
  • Low loss vs speed

Splice Picker FI

  • Min loss → Fusion ( ~0.05 dB )
  • Field quick → Mechanical ( 0.1-0.3 dB )
  • Permanent OSP → Fusion ( Long term )
  • Emergency restore → Mechanical ( No arc )
  • High count ribbon → Fusion mass ( 12 at once )

Fiber Wavelengths FI

  • 850 nm Multimode short MM
  • 1310 nm Singlemode/OM zero SM
  • 1550 nm Singlemode long SM
  • 1490 nm PON downlink
  • 1625 nm OTDR test port
  • Loss Budget Max allowable attenuation
  • Macrobend Bend loss > spec
  • Microbend Small fiber stress loss

Splicing Methods FI

  • Fusion Arc weld, ~0.05 dB 0.05dB
  • Mechanical Adhesive sleeve, 0.1-0.3 dB 0.3dB
  • Cleaver Score/break clean end
  • Splice Tray Holds splice in closure
  • OSP Closure Aerial/buried splice case
  • Splice Box Rack mounted splice

Termination Blocks TE

  • 110 Block Insulation displacement, Cat 5e/6
  • Krone IDC, European telecom
  • BIX Nortel IDC block
  • 66 Block Legacy voice, M-block
  • RJ45 8P8C modular plug
  • RJ11 6P2C/6P4C voice
  • Modular Plug Terminates patch cord
  • Jack Female workstation outlet

Fiber Connectors TE

  • LC Small form factor, snap
  • SC Push-pull, 2.5mm
  • ST Bayonet, 2.5mm
  • MTP 12/24 fiber multifiber
  • MPO Multifiber, ribbon
  • UPC Ultra physical contact, blue
  • APC Angled 8 deg, green
  • Polish PC/UPC/APC return loss

OTDR vs Certification Scanner TE

OTDR

  • Fiber length
  • Fault location
  • Backscatter trace

Scanner

  • Cat 6 cert
  • NEXT/RL
  • Pass/fail report
  • Fiber vs copper

Tester Picker TE

  • Fiber length/fault → OTDR ( Backscatter )
  • Copper length/fault → TDR ( Impedance )
  • Cat 6A cert → Certification Scanner ( TIA pass/fail )
  • End-to-end loss → OLTS ( Source + meter )
  • Broken fiber → VFL ( Red light )
  • Pair tracing → Tone Generator ( Probe amp )

Test Equipment TE

  • OTDR Optical time domain reflectometer
  • TDR Copper fault distance
  • Certification Scanner Validates Cat 6/6A
  • OLTS Optical loss test set
  • OPM Optical power meter
  • VFL Visual fault locator
  • Tone Generator Copper pair trace
  • NVP Nominal velocity propagation

Copper Test Parameters TE

  • NEXT Near-end crosstalk
  • PSNEXT Power sum NEXT
  • ACRF Attenuation crosstalk ratio
  • Return Loss Impedance mismatch
  • Insertion Loss Attenuation, dB
  • Delay Skew Pair timing diff
  • Length TDR distance check

Codes and Standards CO

  • TIA-568 Commercial cabling standard
  • TIA-569 Pathways and spaces
  • TIA-607 Bonding/grounding standard
  • TIA-570 Residential cabling
  • NEC Article 770 Optical fiber cables
  • NEC Article 800 Premises comms wiring
  • NFPA 70 National Electrical Code
  • TSB-95 Cat 5e performance

Firestop Ratings GR

  • F fire T temp L leak W water
  • F hours endurance L cfm leakage W water resistance

Bonding and Grounding GR

  • TBB Telecom bonding backbone, #6 AWG
  • TMGB Telecom main grounding busbar
  • TGB Telecom grounding busbar
  • BCBB Bonding conductor backbone
  • Riser Vertical bonding per floor
  • #6 AWG Min TBB conductor
  • #3 AWG Bonding for multi-floor

Bonding Chain GR

  • TMGB -> TGB -> TBB -> Equipment
  • TMGB main busbar TBB #6 AWG TGB per room

Firestop Systems GR

  • F Rating Fire endurance, hours
  • T Rating Temperature rise, hours
  • L Rating Air leakage, cfm
  • W Rating Water resistance
  • Through Penetration Cable through wall
  • Membrane Penetration One side breach
  • Firestop Putty Retrofittable seal
  • Intumescent Expands with heat

Pathways and Spaces PA

  • Conduit Rigid raceway, fill 40%
  • Cable Tray Open support, ladder
  • Sleeve Wall/floor penetration
  • TR Telecom room, equipment
  • TEF Telecom equipment field
  • ER Equipment room, main
  • Bend Radius Min 10x diameter UTP

Safety SA

  • PPE Gloves, glasses, hard hat
  • Lockout/Tagout Energy isolation
  • Fiber Shard Sharps container dispose
  • Laser Class 1/1M/2/3R fiber safety
  • Ladder 3-point contact
  • Fall Arrest Above 6 ft harness
  • MSDS Solvent/adhesive sheets

Project and Documentation PR

  • As-Built Final installed drawings
  • Test Reports Certification records
  • Warranty Manufacturer 25 yr system
  • Blueprint Read plan/elevation
  • RFP Request for proposal
  • CEC Continuing ed credits

Common Traps

Channel vs permanent

  • Channel includes cords ≠ PL is 90m

T568A vs B

  • A residential WGrn ≠ B commercial WOrg

OM core size

  • OM1 62.5um ≠ OM2-OM5 50um

Splice loss

  • Fusion 0.05 dB ≠ Mechanical up to 0.3

Wavelength use

  • 850 MM short ≠ 1310/1550 SM

Bonding size

  • TBB #6 AWG min ≠ Multi-floor #3 AWG

Hands-on first

  • Hands-on required first ≠ Then written exam

Last Minute

  • 1. 100m channel / 90m permanent link
  • 2. T568A WGrn,Grn,WOrg,Blu,WBlu,Org,WBrn,Brn
  • 3. Cat5e 100MHz,Cat6 250MHz,Cat6A 500MHz
  • 4. OM1 33m,OM3 300m,OM4 400m at 10GbE
  • 5. Singlemode 9um,1310/1550nm
  • 6. Fusion ~0.05 dB,mechanical 0.1-0.3 dB
  • 7. TBB #6AWG TMGB TGB/room
  • 8. Firestop F T L W ratings
  • 9. OTDR fiber TDR copper scanner cert
  • 10. Hands-on 12 tasks,20 min each,first

BICSI Technician

  • Practice Questions 118 questions Study Guide 45 topics Cheat Sheet 119 facts Flashcards 50 cards Shorts 1 short Free CE Podcast

Same family resources

  • Explore More BICSI Certifications
  • Continue into nearby exams from the same family. Each card keeps practice questions, study guides, flashcards, videos, and articles in one place.

BICSI RCDD Registered Communications Distribution Designer

  • Cheat Sheet 118 facts Practice Questions 117 questions Study Guide 32 topics Flashcards 50 cards Shorts 1 short Videos 1 video Blogs 1 blog Free CE

BICSI DCDC Data Center Design Consultant

  • Practice Questions 100 questions Study Guide 61 topics Shorts 1 short Videos 1 video Blogs 1 blog Free CE

BICSI Installer 2 Copper

  • Cheat Sheet 63 facts Practice Questions 329 questions Study Guide 39 topics Flashcards 50 cards Free CE

BICSI Installer 2 Optical Fiber

  • Practice Questions 175 questions Study Guide 45 topics Free CE

BICSI Installer 1 Copper

  • Cheat Sheet 94 facts Practice Questions 121 questions Study Guide 40 topics Flashcards 50 cards Free CE

BICSI OSP Outside Plant Designer

  • Practice Questions 100 questions Free CE

More From This Family

  • Videos and articles for deeper review.
  • Video BICSI RCDD Exam Guide 2026: Registered Communications Distribution Designer Video CDCP vs CDCS vs CDCE vs ATD vs DCDC: 2026 Decision Guide Article CDCP vs CDCS vs CDCE vs ATD vs DCDC: 2026 Decision Guide 17 min read Article BICSI RCDD Exam Guide 2026: Registered Communications Distribution Designer 14 min read