Cheat sheet
Red Seal Truck and Transport Mechanic Cheat Sheet
A: Common Occupational Skills
- 6% of exam
- Safe Work Service identity Hoisting Fasteners
B: Engines and Supporting Systems
- 16% of exam
- Engine Tests Aftertreatment Compression Rail service
C: Air Systems and Brake Systems
- 13% of exam
- Air and Brake Checks Governor Brake stroke Spring chamber
D: Electrical and Electronic Systems
- 16% of exam
- Electrical Relationships Electrical Diagnosis Loaded voltage drop No communication
E: Drive Trains
- 12% of exam
- Drivetrain Checks Clutch release AMT calibration Axle ratio
F: Steering, Chassis/Frames, Suspensions, Tires, Wheels, Hubs
- 13% of exam
- Chassis and Wheel Checks Kingpin play Multi-piece rim Wheel bearing
G: Cabs
- 4% of exam
- Cab Checks Seat drops Wiper stalls SRS service
H: Trailers
- 6% of exam
- Trailer Checks Landing gear Reefer service Defrost
I: Climate Control Systems
- 5% of exam
- Climate Checks Evaporator Condenser Heater airflow
J: Hydraulic Systems
- 6% of exam
- Hydraulic Checks Hydraulic force Slow actuator Injection injury
K: Hybrid and Electric Vehicles
- 3% of exam
- High-Voltage Safety Qualified HV technician Isolation Verification
Quick Facts
- Official questions 135 multiple-choice questions
- Writing time 4 hours
- Passing mark 70%
- Answer format Four options; one correct answer
- Blueprint 11 blocks; A–K
- Largest block Electrical/electronic systems; 22 questions
- Weights Published percentages; counts shown below
- Supplied references Trade formulas and acronyms
- Ontario identity Truck and Coach Technician; 310T
- Fees and rewrites Confirm provincial/territorial authority rules
Diagnostic Sequence CO
- Confirm → Measure → Compare → Repair → Verify
- Confirm: concern and conditions Measure: prescribed tests Compare: OEM expected values Verify: retest and document
Safe Test Picker CO
- Before work beneath raised truck → Rated support; secure against movement ( OEM lift points and locks )
- Before high-voltage component work → Qualified technician; OEM isolation procedure ( Discharge; verify with rated equipment )
- Before pressurized fuel line service → OEM shutdown, isolation, depressurization ( Verify pressure safe before opening )
- Before cooling pressure test → Safe temperature; OEM test pressure ( Correct tester and adapters )
- Excess automatic-adjuster stroke → Adjuster and foundation-brake cause diagnosis ( Chamber-specific pressure and stroke limits )
- Before reefer inspection/service → Qualified service; disable automatic start ( Isolate unit-specific energy sources )
- Slow hydraulic actuator → Flow, restriction, leakage tests ( Specified load and operating conditions )
- Hydraulic injection puncture → Seek immediate emergency medical treatment ( Identify injected fluid )
- Before multi-piece rim inflation → Trained personnel; prescribed restraining device ( Stay outside possible component trajectory )
Safe Work CO
- Lockout Isolate, restrain, dissipate, verify energy Block A: 8 questions
- Raised truck Rated supports; lock lift; restrain vehicle
- Hoisting Load, sling angle, anchor ratings
- Service identity VIN, component ID, current bulletins
- Fasteners OEM torque, sequence, replacement rules
- Fluid selection Application, climate, OEM grade
- Mentoring Demonstrate; learner practices; give feedback
Compression vs Leakage EN
Compression
- Measures developed cylinder pressure
- Specified cranking/test conditions
Leakage
- Introduces regulated test air
- Escape path helps locate leak
- Measure sealing; then localize leakage
Engine Tests EN
- Compression Measures cylinder sealing performance Block B: 21 questions
- Leakage test Locates escaping test air
- Low oil-pressure warning Stop safely; verify specified gauge pressure
- CAC leaks OEM pressure-limited leak test
- Rail service OEM shutdown; isolate; verify depressurization
- Cooling test Safe temperature; OEM test pressure
- Engine retarder Supplements service-brake deceleration
Soot vs Ash EN
Soot
- Combustible trapped particulate
- Regeneration oxidizes it
Ash
- Noncombustible residue
- Specified cleaning/removal
- Regeneration does not remove ash
Aftertreatment EN
- DPF Traps soot in porous filter
- Regeneration Oxidizes soot; leaves ash
- Ash Specified cleaning or filter replacement
- SCR DEF-supported catalytic NOx reduction
- Exhaust diagnosis Pressure, temperature, dosing; OEM tests
Relay Memory AI
- Relay receives control; reservoir supplies chambers
- Control line: foot-valve signal Supply line: local reservoir air
Service vs Spring Brake AI
Service chamber
- Air pressure applies braking
- Pedal-commanded brake demand
Spring chamber
- Spring applies parking brake
- Air releases powerful spring
- No air still leaves spring energy
Air and Brake Checks AI
- Governor cut-in Compressor resumes charging Block C: 17 questions
- Governor cut-out Compressor unloads
- Air dryer Removes moisture; reservoirs still checked
- Relay valve Local reservoir supplies brake chambers
- Spring chamber Stored spring energy; never disassemble
- Brake stroke Chamber-specific limits and test pressure
- Automatic slack adjuster Excess stroke requires cause diagnosis
- ABS warning Codes and system tests required
Electrical Relationships EL
- Voltage = current × resistance; DC power = voltage × current
- V: volts I: amperes R: ohms P: DC power in watts
Series vs Parallel Batteries EL
Series
- Compatible voltages add
- Two 12 V → 24 V
Parallel
- Voltage remains nominally equal
- Compatible capacity increases
- Follow OEM battery compatibility requirements
Electrical Test Picker EL
- No crank → Battery, loaded cables, start command ( Retain safety interlocks; OEM tests )
- Normal battery; slow crank → Loaded power and ground drops ( Compare OEM limits )
- Missing spark → Approved spark tester; supply/control checks ( OEM spark-ignition procedure )
- Module will not communicate → Power, grounds, data-link tests ( Vehicle wiring diagram )
- Resistance measurement needed → De-energize; discharge; isolate parallel paths ( Follow applicable OEM procedure )
- Alternator output seems low → Specified speed/load; cable-drop tests ( Check belt and regulator control )
- Code points to sensor → Test supply, ground, signal ( Code alone does not prove failure )
- Intermittent electrical concern → Connections, wiring; logged data ( Preserve codes before clearing )
- Electrical repair completed → Retest under specified operating conditions ( Record tests and results )
Electrical Relationships EL
- Voltage V = I × R Block D: 22 questions
- Current I = V ÷ R
- DC electrical power P = V × I
- Ideal 24 V; 6 Ω 4 A load current
- 24 V DC; 100 A 2,400 W electrical output
- Series 12 V batteries 24 V nominal; compatible pair
- Parallel 12 V batteries 12 V nominal; increased capacity
DTC vs Failure Cause EL
DTC
- Reports detected condition
- Guides diagnostic test selection
Cause
- Established by measurements
- May involve wiring or supply
- Test before replacing named components
Electrical Diagnosis EL
- Voltage drop Measure across path under prescribed load
- Resistance mode De-energize; discharge; isolate parallel paths
- No crank Battery, loaded paths, interlocks, command
- Spark ignition Approved spark tester; supply/control checks
- No communication Power, grounds, network; wiring diagram
- DTC Detected condition; follow diagnostic tests
Drivetrain Checks DR
- Clutch release OEM bearing travel and linkage checks Block E: 17 questions
- Automatic-transmission fluid Level at specified temperature/conditions
- AMT calibration After clutch replacement: specified calibration
- Driveline vibration Ride height, angles, phasing, joints
- Transfer case Distributes output to additional driven axles
- Axle ratio Ring teeth ÷ pinion teeth
- 41 ring; 10 pinion teeth 4.10:1 pinion-to-ring revolution ratio
Chassis and Wheel Checks CH
- Steer-tire wear Inspect pressure, play, bearings, suspension Block F: 18 questions
- Kingpin play Axle-specific loading, measurement, wear limits
- Air ride height OEM dimension; pressure varies with load
- Frame cracks Material/location-specific OEM repair procedure
- Coupler play Check wear, mounts, positive lock
- Multi-piece rim Trained service; restraint; outside trajectory
- Rim heat Never heat or weld rim components
- Wheel bearing Dial-indicator end play; hub-specific limits
Cab Checks CA
- Seat drops Inspect pneumatic supply, controls, leakage Block G: 5 questions
- Wiper stalls Check linkage binding and electrical supply
- SRS service OEM isolation and capacitor discharge
- Cab tilt Support and lock using OEM procedure
Trailer Checks TR
- Landing gear Support trailer; inspect gearing/cross-shaft Block H: 8 questions
- Reefer service Qualified technician; isolate automatic-start energy
- Defrost Removes evaporator ice; restores airflow
- Trailer structure Inspect corrosion, cracks, fasteners, flooring
- Trailer lighting Check circuit, connectors, ground; applicable rules
Climate Checks CL
- Evaporator Absorbs cab heat; refrigerant evaporates Block I: 7 questions
- Condenser Rejects heat; refrigerant condenses
- Low heater airflow Blower, filter, duct diagnosis
- Low heater temperature Coolant flow, core, temperature controls
- A/C recharge Identify refrigerant; recover; OEM charge
Hydraulic Pressure vs Flow HY
Pressure
- Force per piston area
- Load-related measurement
Flow
- Speed × effective piston area
- Measured under specified load
- Pressure alone cannot establish delivered flow
Hydraulic Checks HY
- Hydraulic force F = A × P Block J: 8 questions
- Piston area A = 3.14 × r²
- 50 mm bore; 10 MPa 19.625 kN ideal cap-end force π3.14; no losses/opposing pressure
- Slow actuator Test delivered flow under specified load
- Leak search Never use hands near pressure leaks
- Injection injury Immediate emergency treatment; identify injected fluid
Energy Control HY
- Identify → Isolate → Control → Verify
- Identify: all energy sources Isolate: vehicle-specific procedure Control: stored-energy hazards Verify: rated equipment and PPE
High-Voltage Safety HY
- Qualified HV technician Vehicle-specific training, rated tools, required PPE Block K: 4 questions
- Isolation OEM high/low-voltage and charging isolation Hybrid engine sources also isolated
- Discharge Observe vehicle-specific stored-energy discharge procedure
- Verification Rated meter, required PPE; prove isolation
Common Traps
Ignition-off vs isolation
- Ignition-off stops a command ≠ Isolation controls all hazardous energy
Zero air vs zero energy
- Chamber air can be exhausted ≠ Spring still stores mechanical energy
Code vs failed component
- Code reports a detected condition ≠ Tests establish the failure cause
Dryer vs dry reservoirs
- Dryer removes most moisture ≠ Reservoir checks/draining remain specified
Stroke correction vs repair
- Manual readjustment may hide excessive stroke ≠ Repair identified cause; verify stroke
Nominal vs measured voltage
- Nominal voltage names the system ≠ Measured voltage depends on operating conditions
Last Minute
- 1. 135 questions; four hours; 70% pass
- 2. Electrical block: 22; engines: 21 questions
- 3. Ontario: Truck and Coach Technician, 310T
- 4. Loaded voltage-drop tests reveal unwanted resistance
- 5. Resistance tests require de-energized, discharged circuits
- 6. Regeneration burns soot; ash requires cleaning
- 7. Spring-brake energy remains without air pressure
- 8. Brake-stroke limits require chamber-specific test conditions
- 9. Inspect wear before changing steering geometry
- 10. Reefer service requires automatic-start energy isolation
- 11. Hydraulic injection needs immediate emergency treatment
- 12. Qualified HV work: isolate, discharge, verify
- 13. Verify repairs under specified operating conditions
Red Seal Truck and Transport Mechanic (Interprovincial Exam)
- Practice Questions 135 questions Study Guide 56 topics Cheat Sheet 79 facts Flashcards 50 cards Podcast