Cheat sheet
NMTCB CNMT Cheat Sheet
Radiation Physics + Detection
- 7% of exam
- Radioactive Materials Decay Photon Interactions Counting Statistics Detectors
Radiation Safety + Regulations
- 13% of exam
- ALARA Surveys Dosimetry NRC Records
Pharmaceutical + Radiopharmaceutical Agents
- 25% of exam
- Generators Kit Preparation Quality Control Diagnostic Agents Therapy Agents
Instrument Operations + QC
- 15% of exam
- Dose Calibrator Gamma Camera SPECT PET Artifacts
Clinical Procedures
- 40% of exam
- Patient Screening Procedure Selection Acquisition Image Quality Patient Education
Quick Facts
- Credential Certified Nuclear Medicine Technologist
- Owner NMTCB
- Exam type Classification CAT
- Items 90 total items
- Time 1 hour 55 minutes
- Format Four-to-five option MCQ
- Passing score 375 scaled score
- Scale 200 to 500
- Unscored items Seamlessly included
- Navigation No skip or return
Compton vs Photoelectric PH
Compton
- Photon deflection
- Scatter contribution
Photoelectric
- Photon absorption
- Energy transfer
- Scatter vs absorption
Physics Foundations PH
- Isotope Element nuclear variant
- Half-life Time for half decay
- Gamma emitter Emits gamma photon
- Beta emitter Emits beta particle
- Alpha emitter Emits alpha particle
- Positron emitter Emits positron
- Counting statistics Quantify count variation
Detection + Interactions PH
- Compton scatter Photon deflection interaction
- Photoelectric effect Photon absorption interaction
- NaI well Scintillation detector
- Ion chamber Gas ionization detector
- Solid-state detector Semiconductor radiation detector
- GM meter Gas survey detector
- Energy spectrum Detected energy distribution
ALARA SA
- Time, distance, shielding reduce exposure
- Shorter time More distance Proper shielding
Deterministic vs Stochastic SA
Deterministic
- Threshold-related
- Tissue effect
Stochastic
- Probability-related
- Cancer risk
- Threshold effect vs probability
Safety + Protection SA
- ALARA Minimize practical exposure
- Time Reduce exposure duration
- Distance Increase source separation
- Shielding Attenuate radiation
- Deterministic effect Threshold-related tissue effect
- Stochastic effect Probability-based effect
- Radiosensitivity Cell response to radiation
Regulatory Controls SA
- Area survey Monitor radiation area
- Personal monitor Track worker exposure
- Restricted area Controlled radiation access
- NRC Nuclear regulatory authority
- Radioactive waste Controlled waste handling
- Written directive Required therapy authorization
- HIPAA Protect patient privacy
Radiochemical vs Radionuclidic Purity AG
Radiochemical
- Desired chemical form
- Kit quality control
Radionuclidic
- Correct radionuclide
- Generator breakthrough
- Chemical form vs nuclide
Radiopharmacy Preparation AG
- Generator Produces daughter radionuclide
- Eluate Generator collection product
- Mo-99 breakthrough Generator QC result
- Aluminum breakthrough Generator QC result
- Kit preparation Prepare radiopharmaceutical dose
- Radiochemical purity Desired chemical fraction
- Dose calibrator Measure dose activity
Agent Application AG
- Diagnostic agent Supports diagnostic imaging
- Therapeutic agent Delivers radionuclide therapy
- Tc-99m agent Common diagnostic category
- PET agent Positron imaging agent
- Adjunct drug Supports procedure protocol
- Blood labeling Radiolabel blood components
- Administration route Use prescribed route
SPECT vs PET IN
SPECT
- Gamma photon imaging
- Tomographic acquisition
PET
- Positron emission imaging
- Coincidence detection
- Single photons vs coincidence
Instrument Systems IN
- Well counter Count small samples
- Survey meter Measure contamination exposure
- Gamma camera Planar photon imaging
- SPECT Tomographic gamma imaging
- PET Positron emission imaging
- CT X-ray cross-section imaging
- PACS Image storage network
Uniformity vs Resolution IN
Uniformity
- Consistent detector response
- QC consistency
Resolution
- Distinguish structures
- Image detail
- Even response vs detail
Quality Control IN
- Constancy Check consistent response
- Uniformity Check detector consistency
- Center of rotation SPECT alignment check
- Energy resolution Separate photon energies
- Spatial resolution Distinguish small structures
- Attenuation correction Adjust tissue photon loss
- Artifact Nonclinical image feature
Five Domains CL
- Physics, safety, agents, QC, clinical
- 7 percent 13 percent 40 percent
CAT vs Fixed Form CL
Classification CAT
- Pass/fail decision
- Different item sets
Fixed form
- Same item set
- Common administration
- Adaptive classification vs fixed test
Blueprint Picker CL
- Need decay review → Physics ( 7 percent )
- Need detector review → Physics ( Detection principles )
- Need ALARA review → Safety ( 13 percent )
- Need NRC review → Safety ( Regulations and records )
- Need generator review → Agents ( 25 percent )
- Need agent review → Agents ( Preparation and application )
- Need camera review → Instrumentation ( 15 percent )
- Need QC review → Instrumentation ( Operations and artifacts )
- Need procedure review → Clinical ( 40 percent )
Clinical Workflow CL
- Patient identification Verify correct patient
- Order review Verify requested study
- Pre-exam screening Check preparation factors
- Informed consent Support authorized procedure
- Patient education Explain procedure precautions
- Positioning Prepare reproducible acquisition
- Image quality Evaluate diagnostic adequacy
Procedure Workflow CL
- Screen, reconcile, acquire, evaluate, document
- Patient safety Image quality Clear record
Procedure Safety Scan CL
- Before procedure → Verify identity ( Patient and order )
- Preparation needed → Screen patient ( Protocol factors )
- Agent prescribed → Reconcile agent ( Patient and dose )
- Dose prepared → Check quality ( Follow procedure )
- Imaging begins → Position patient ( Acquisition parameters )
- Image acquired → Evaluate quality ( Artifacts and coverage )
- Safety concern → Follow emergency protocol ( Escalate promptly )
- Therapy involved → Follow written directive ( Authorized-user guidance )
- Procedure ends → Document and educate ( Records and precautions )
Procedure Families CL
- Pulmonary Ventilation and perfusion
- Bone imaging Musculoskeletal procedure family
- Oncology Tumor imaging procedures
- Renal Genitourinary procedure family
- Endocrine Thyroid and parathyroid
- Cardiovascular Cardiac procedure family
- CNS Central nervous procedures
Common Traps
Scaled score ≠ percentage
- 375 is passing ≠ Scale is 200-500
CAT ≠ harder questions
- Classification purpose ≠ Equated item sets
Pretest ≠ visible
- Seamlessly included ≠ Cannot identify items
Domain weight ≠ order
- Random content order ≠ Approximate proportions
SPECT/CT ≠ PET/CT
- Gamma camera hybrid ≠ Positron camera hybrid
Clinical outline ≠ local protocol
- Study content scope ≠ Follow authorized procedures
Last Minute
- 1. Prioritize Clinical Procedures: 40 percent
- 2. Review Agents: 25 percent
- 3. Review Instrumentation: 15 percent
- 4. Review Safety: 13 percent
- 5. Review Physics: 7 percent
- 6. Know 90-item CAT format
- 7. Remember 375 scaled passing score
- 8. Answer before moving forward
- 9. Cannot return to items
- 10. Use official COPS outline
NMTCB Certified Nuclear Medicine Technologist
- Practice Questions 114 questions Study Guide 57 topics Cheat Sheet 70 facts Flashcards 50 cards Free CE Podcast