Cheat sheet

COA Ophthalmic Cheat Sheet

Practice this exam

History + Documentation

  • 9% of exam
  • Chief Complaint Ocular History Meds + Allergies SOAP Notes

Visual Assessment

  • 7% of exam
  • Snellen Near Vision Pinhole Low Vision

Visual Field Testing

  • 6% of exam
  • Confrontation Amsler Grid Automated Fields Reliability

Pupil Assessment

  • 7% of exam
  • PERRLA RAPD Anisocoria Swinging Light

Tonometry

  • 7% of exam
  • IOP Goldmann NCT Disinfection

Keratometry

  • 2% of exam
  • Corneal Curve Mires Contact Lens IOL Planning

Lensometry

  • 3% of exam
  • Sphere Cylinder Axis Add Power

Biometry

  • 3% of exam
  • Axial Length A-Scan IOL Power Cataract

Diagnostic Ultrasound

  • 2% of exam
  • A-Scan B-Scan Media Opacity Posterior Segment

Supplemental Testing

  • 3% of exam
  • BAT PAM Color Plates Tear Tests

Microbiology

  • 2% of exam
  • Standard Precautions Asepsis Cultures Transmission

Pharmacology

  • 6% of exam
  • Drops Mydriatics Cycloplegics Side Effects

Surgical Assisting

  • 3% of exam
  • Aseptic Technique Instrument Prep Laser Safety Site ID

Patient Services

  • 8% of exam
  • Education Triage Accessibility Vital Signs

Optics + Spectacles

  • 2% of exam
  • Lens Power Prism Frames Adjustments

Contact Lenses

  • 2% of exam
  • Soft Lens RGP Hygiene Overwear

Equipment Maintenance

  • 2% of exam
  • Cleaning Calibration Troubleshooting Safe Use

Ethics + Legal

  • 4% of exam
  • HIPAA Consent Scope Documentation

General Medical Knowledge

  • 8% of exam
  • Anatomy Systemic Disease Terminology Safety

Refraction

  • 5% of exam
  • Autorefraction Transposition Spherical Equivalent Vertex

Ophthalmic Imaging

  • 5% of exam
  • OCT Fundus Photo Image Quality Documentation

Ocular Motility Testing

  • 4% of exam
  • Versions Ductions Cover Test Diplopia

Quick Facts

  • Exam COA
  • Credential Certified Ophthalmic Assistant
  • Body IJCAHPO
  • Level Entry core
  • Questions 200 scored
  • Time 180 minutes
  • Delivery Pearson VUE
  • Scoring Modified Angoff
  • Fee $300 initial
  • Blueprint August 1 2025

Core History HI

  • COMFS: complaint, ocular, meds, family, social.
  • Complaint Ocular history Meds/allergies Family Social

COA vs COT HI

COA

  • Entry core
  • Assistant level
  • 200 scored

COT

  • Intermediate core
  • Technician level
  • Skill evaluation
  • Assistant before technician

History + Documentation HI

  • CC Reason for visit
  • HPI Symptom story
  • Ocular Hx Eye disease history
  • Medical Hx Systemic conditions
  • Meds Current medications
  • Allergies Drug reaction risk
  • Family Hx Inherited eye risks
  • Social Hx Smoking work driving
  • SOAP Structured note
  • OD/OS/OU Right left both

Snellen Fraction VI

  • Top is test; bottom is normal.
  • 20 feet Normal distance Higher bottom worse

Acuity vs Refraction VI

Acuity

  • Measures seeing
  • Snellen result
  • Screening output

Refraction

  • Finds correction
  • Diopter result
  • Rx process
  • Seeing vs correcting

Visual Acuity VI

  • Snellen top Testing distance
  • Snellen bottom Normal-eye distance
  • 20/40 Worse than normal
  • Pinhole Refractive screen
  • CF Counting fingers
  • HM Hand motion
  • LP Light perception
  • NLP No light perception
  • Near card Reading distance test
  • Stereoacuity Depth perception

Confrontation vs Automated VI

Confrontation

  • Gross screen
  • Exam room
  • Fast comparison

Automated

  • Mapped field
  • Reliability indices
  • Disease monitoring
  • Screen vs quantify

Fields + Pupils VI

  • Confrontation Gross field screen
  • Amsler Macula distortion grid
  • Perimetry Mapped visual field
  • Fixation loss Reliability warning
  • False positive Trigger happy
  • False negative Missed seen stimulus
  • PERRLA Pupils equal reactive
  • RAPD Afferent defect
  • Swinging light Compares optic nerves
  • Anisocoria Unequal pupils

Pupil Check PU

  • Size, shape, reaction, RAPD.
  • Measure Compare Light Swinging test

RAPD vs Anisocoria PU

RAPD

  • Afferent problem
  • Swinging light
  • Optic nerve cue

Anisocoria

  • Size difference
  • Light/dark compare
  • Autonomic cue
  • Input vs size

Pupil Picker PU

  • Compare optic nerves → Swinging light ( RAPD )
  • Unequal pupils → Measure light/dark
  • Direct reflex → Same-eye response
  • Consensual reflex → Opposite-eye response
  • Poor near response → Check accommodation
  • Pharmacologic concern → Alert physician

Goldmann Endpoint TO

  • Inner fluorescein edges just touch.
  • Too wide low Overlap high Touch correct

Goldmann vs NCT TO

Goldmann

  • Applanation contact
  • Fluorescein mires
  • More precise

NCT

  • Air puff
  • No contact
  • Screening tool
  • Contact vs air

IOP Picker TO

  • Precise IOP needed → Goldmann
  • Screening only → NCT
  • Bedside patient → Tono-Pen
  • Mires too wide → Increase force
  • Mires overlap → Decrease force
  • After tonometer use → Disinfect tip

Tonometry + Keratometry TO

  • IOP Intraocular pressure
  • GAT Gold standard applanation
  • NCT Air puff screen
  • Tono-Pen Handheld applanator
  • Fluorescein Goldmann endpoint aid
  • Mires touch Correct GAT endpoint
  • Thick cornea IOP may overread
  • Thin cornea IOP may underread
  • K reading Corneal curvature
  • Distorted mires Poor keratometry quality

Keratometry vs Biometry KE

Keratometry

  • Corneal curvature
  • K readings
  • Contact lens cue

Biometry

  • Axial length
  • IOL planning
  • Cataract cue
  • Curve vs length

Lensometry + Refraction LE

  • Sphere All meridians
  • Cylinder Astigmatic difference
  • Axis No cylinder power
  • Add Near plus power
  • Prism Image displacement
  • Plus lens Thick center
  • Minus lens Thick edge
  • Myopia Minus correction
  • Hyperopia Plus correction
  • SE Sphere plus half cyl
  • Transpose Add flip rotate
  • Vertex Lens-eye distance

Biometry + Ultrasound BI

  • Axial length Front-back eye length
  • A-scan One-dimensional echo
  • B-scan Two-dimensional image
  • IOL power Cataract implant planning
  • Immersion Less compression error
  • Contact A-scan Cornea touch risk
  • Dense cataract Ultrasound indication
  • Retinal detachment B-scan concern

A-Scan vs B-Scan UL

A-scan

  • One dimension
  • Axial length
  • IOL calculation

B-scan

  • Two dimensions
  • Posterior image
  • Opaque media
  • Measure vs image

Test Picker SU

  • Macula distortion → Amsler grid
  • Glare complaint → BAT
  • Color defect → Ishihara
  • Dry eye → Schirmer/TBUT
  • Angle depth → Van Herick
  • Corneal thickness → Pachymetry

Supplemental Tests SU

  • BAT Glare testing
  • PAM Potential acuity
  • Ishihara Color vision plates
  • Schirmer Tear production
  • TBUT Tear stability
  • Rose Bengal Surface staining
  • Pachymetry Corneal thickness
  • Van Herick Angle depth screen

Microbiology MI

  • Standard precautions All patients
  • Hand hygiene Before and after
  • Clinical asepsis Reduce microorganisms
  • Disinfection Kills many pathogens
  • Sterilization Kills all microbes
  • Bacteria Cellular organisms
  • Virus Host-cell dependent
  • Fungus Yeast or mold
  • Specimen Culture sample
  • Fomite Contaminated object

Mydriatic vs Cycloplegic PH

Mydriatic

  • Dilates pupil
  • Retina view
  • Light sensitivity

Cycloplegic

  • Stops focusing
  • Pediatric refraction
  • Blurred near
  • Pupil vs focus

Drop Picker PH

  • Need dilation → Mydriatic
  • Stop accommodation → Cycloplegic
  • Numb cornea → Anesthetic
  • Corneal stain → Fluorescein
  • Multiple drops → Wait 5 min
  • Systemic risk → Punctal occlusion

Pharmacology PH

  • Mydriatic Dilates pupil
  • Cycloplegic Paralyzes accommodation
  • Anesthetic Numbs surface
  • Fluorescein Stains tear film
  • Antibiotic Bacterial treatment
  • Steroid Inflammation suppression
  • NSAID Nonsteroid inflammation
  • Lubricant Artificial tears
  • Punctal occlusion Limits systemic absorption
  • Five minutes Between drops

Aseptic vs Sterile SU

Aseptic

  • Prevents contamination
  • Technique concept
  • Clinical workflow

Sterile

  • No living microbes
  • Field status
  • Surgical standard
  • Method vs state

Surgery + Equipment SU

  • Aseptic technique Prevent contamination
  • Sterile field Protected workspace
  • Site ID Correct eye check
  • Time-out Final safety pause
  • Laser safety Eye protection required
  • Instrument prep Ready sterile tools
  • Calibration Accuracy check
  • Maintenance log Service documentation
  • Slit lamp Anterior exam tool
  • Lens cleaner Optics protection

Ocular Emergency PA

  • Chemical burns irrigate before paperwork.
  • Irrigate now Alert physician Document after

Triage Picker PA

  • Chemical splash → Irrigate now ( Then alert )
  • Flashes floaters → Urgent retina ( Same day )
  • Sudden vision loss → Alert physician ( Emergency )
  • Severe eye pain → Urgent evaluation ( Do not delay )
  • Post-op shield issue → Call surgeon ( Follow protocol )
  • Routine refill → Check chart ( Follow policy )

Patient Services + Ethics PA

  • Triage Urgency sorting
  • Flashes/floaters Retina warning
  • Chemical burn Immediate irrigation
  • Consent Permission before procedure
  • HIPAA Protect PHI
  • Scope Stay within role
  • Education Clear patient instructions
  • Accessibility Adapt communication
  • Vital signs BP pulse respirations
  • Dissatisfaction Acknowledge escalate document

Contact Lenses CO

  • Soft lens Flexible hydrogel
  • RGP Rigid gas permeable
  • Base curve Lens curvature
  • Diameter Overall lens size
  • Overwear Hypoxia risk
  • No water Acanthamoeba prevention
  • Rub rinse Deposit removal
  • Red painful eye Stop lens wear

HIPAA vs Consent ET

HIPAA

  • Privacy rule
  • PHI sharing
  • Minimum necessary

Consent

  • Procedure permission
  • Patient agreement
  • Before action
  • Privacy vs permission

General Medical GE

  • Cornea Major refraction
  • Lens Accommodation
  • Retina Neural tissue
  • Macula Central vision
  • Optic nerve CN II
  • EOMs Move eyes
  • Aqueous Anterior fluid
  • Vitreous Posterior gel
  • Diabetes Retinopathy risk
  • Thyroid Orbit disease risk
  • Inflammation Immune response
  • Infection Pathogen invasion

Transposition RE

  • Add sphere, flip cyl, rotate axis.
  • New sphere Opposite cylinder Axis plus 90

OCT vs Fundus Photo IM

OCT

  • Layer cross-section
  • Signal strength
  • Macula/nerve

Photo

  • Surface documentation
  • Color record
  • Disc/retina
  • Layers vs surface

Imaging Picker IM

  • Retinal layers → OCT
  • Disc documentation → Fundus photo
  • Leakage pattern → FA
  • Choroid detail → ICG
  • Poor signal → Repeat image
  • Media opacity → B-scan

Imaging IM

  • OCT Cross-section retina
  • Fundus photo Retinal documentation
  • FA Fluorescein angiography
  • ICG Choroidal angiography
  • Red-free Nerve fiber view
  • Stereo disc Cup-depth documentation
  • Artifact Nonclinical image flaw
  • Signal strength OCT quality cue

Versions vs Ductions MO

Versions

  • Both eyes
  • Binocular movement
  • Together gaze

Ductions

  • One eye
  • Monocular movement
  • Isolated muscle
  • Both vs one

Motility MO

  • Versions Both eyes move
  • Ductions One eye moves
  • Cover test Tropia screen
  • Alternate cover Phoria screen
  • NPC Convergence near point
  • Nystagmus Rhythmic movement
  • Diplopia Double vision
  • Stereo Binocular depth

Common Traps

Exam item count

  • 200 scored questions ≠ Not 100 items

Passing score myth

  • Modified Angoff ≠ Not fixed percent

Snellen fraction

  • Top is distance ≠ Bottom is benchmark

Pinhole meaning

  • Improves refractive blur ≠ Not disease cure

RAPD vs pupil size

  • RAPD is afferent ≠ Anisocoria is size

GAT endpoint

  • Edges just touch ≠ Not full overlap

Multiple drops

  • Wait five minutes ≠ Do not stack

A-scan vs B-scan

  • A-scan measures ≠ B-scan images

K vs AL

  • K is cornea ≠ AL is eye length

Sterile vs clean

  • Sterile kills all ≠ Clean reduces soil

Contact lens pain

  • Stop lens wear ≠ Do not reassure

Scope boundary

  • Assist and document ≠ Do not diagnose

Last Minute

  • 1. COA has 200 scored
  • 2. Time limit is 180 minutes
  • 3. Blueprint effective August 2025
  • 4. History is highest: 9%
  • 5. Patient services: 8%
  • 6. General medical: 8%
  • 7. Acuity/pupils/IOP: 7% each
  • 8. Snellen top is distance
  • 9. Pinhole screens refraction
  • 10. RAPD uses swinging light
  • 11. GAT mires just touch
  • 12. Keratometry measures cornea
  • 13. A-scan measures axial length
  • 14. OCT shows retinal layers
  • 15. Wait five minutes between drops
  • 16. Chemical burn: irrigate immediately
  • 17. Protect PHI; stay in scope