Cheat sheet
COT Ophthalmic Technician Cheat Sheet
History + Documentation
- 10% of exam
- Chief Complaint Ocular History SOAP Note HIPAA
Visual Assessment
- 15% of exam
- Visual Acuity Scale Pupils + Color RAPD Amsler Grid
Refractometry + Lensometry
- 15% of exam
- Refractive Errors Optics + Formulas Refraction Tools Lensometry
Ocular Motility + Binocular
- 10% of exam
- Cover Test EOM Innervation NPC Worth 4-dot
Diagnostic Testing + Imaging
- 20% of exam
- Tonometry + IOP Visual Fields Imaging Keratometry + Biometry
Patient Care + Pharmacology
- 15% of exam
- Pharmacology Anatomy + Triage Drop Picker Emergencies
Surgical Assisting
- 15% of exam
- Surgical Assisting Sterile Technique IOL + Phaco Microbiology
Quick Facts
- Exam COT
- Credential Certified Ophthalmic Technician
- Body IJCAHPO
- Level Intermediate
- MCQ 200 questions
- Time 180 min MCQ
- Skills 7-station evaluation
- Delivery Pearson VUE
- Fee $325 initial
- Renew 3 yrs, 27 CE
History + Documentation HI
- CC Reason for visit
- HPI Symptom story
- OD/OS/OU Right, left, both
- Meds + allergies Drug reaction risk
- Ocular Hx Past eye disease
- Family Hx Inherited eye risk
- SOAP Structured chart note
- HIPAA Protect patient information
- Minimum necessary Share only needed
Snellen Fraction VI
- Top is test, bottom is normal
- Top: your distance Bottom: normal distance Bigger bottom worse
RAPD vs Anisocoria VI
RAPD
- Afferent problem
- Swinging light
- Optic nerve cue
Anisocoria
- Size difference
- Light and dark
- Autonomic cue
- Input vs size
Visual Acuity Scale VI
- Snellen top Testing distance
- Snellen bottom Normal-eye distance
- 20/40 Worse than normal
- 20/20-2 Missed two letters
- Pinhole Screens refractive blur
- CF Counting fingers
- HM Hand motion
- LP / NLP Light or none
- Tumbling E Nonreader acuity chart
- Teller cards Infant preferential looking
Pupils, Color + Screens VI
- PERRLA Pupils equal, reactive
- RAPD Afferent pupil defect
- Swinging light Detects RAPD
- Anisocoria Unequal pupil size
- Direct reflex Same eye constricts
- Consensual reflex Other eye constricts
- Ishihara Red-green color plates
- Amsler grid Central distortion screen
- Confrontation Gross field screen
Lensometry Order RE
- Sphere first, then cylinder power
- Most plus meridian Then orthogonal Difference is cylinder
Retinoscopy vs Subjective RE
Retinoscopy
- No responses needed
- Neutralize reflex
- Children reliable
Subjective
- Patient compares
- Phoropter choices
- Needs cooperation
- Objective vs subjective
Refraction Tool Picker RE
- No patient responses → Retinoscopy
- Refine astigmatism → JCC
- Balance final sphere → Duochrome
- Quick starting Rx → Autorefractor
- Read glasses power → Lensometer
- Corneal curvature → Keratometer
- Child hidden hyperopia → Cycloplegic refraction
Refractive Errors RE
- Myopia Minus lens correction
- Hyperopia Plus lens correction
- Astigmatism Cylinder lens correction
- Presbyopia Age near-focus loss
- Emmetropia No correction needed
- Anisometropia Unequal eye powers
- WTR Steep vertical meridian
- ATR Steep horizontal meridian
Transposition RE
- Add sphere, flip cylinder, rotate ninety
- New sphere sums Cylinder sign flips Axis plus ninety
Optics + Formulas RE
- Diopter 1 / focal length (m)
- Lens power P = 1/f (meters)
- Vergence L' = L + P
- Spherical equivalent Sphere + half cylinder
- Prism diopter 1 cm shift at 1 m
- Prentice rule Prism = decentration × power
- Transposition Add sphere, flip cylinder
- Vertex Lens-to-eye distance
- Plus lens Converges light rays
Refraction + Lensometry Tools RE
- Phoropter Subjective refraction lenses
- Retinoscopy Objective refraction reflex
- JCC Refines cylinder axis, power
- Duochrome Red-green sphere balance
- Autorefraction Machine starting point
- Lensometer Reads spectacle power
- Neutralize order Sphere before cylinder
- Cycloplegic refraction Reveals hidden hyperopia
- PD Pupillary distance (mm)
EOM Innervation MO
- SO4, LR6, all the rest CN3
- SO: CN IV LR: CN VI Rest: CN III
Cover-Uncover vs Alternate MO
Cover-uncover
- Manifest tropia
- Fusion intact
- One eye covered
Alternate cover
- Total deviation
- Breaks fusion
- Tropia plus phoria
- Tropia vs total
Motility + Binocular Vision MO
- Versions Both eyes together
- Ductions One eye alone
- Cover-uncover Detects tropia
- Alternate cover Total deviation
- NPC Convergence near point
- Esotropia Eye turns inward
- Exotropia Eye turns outward
- SO4-LR6-rest3 Muscle nerve rule
- Worth 4-dot Fusion and suppression
- Stereopsis Binocular depth vision
Goldmann Endpoint DI
- Inner fluorescein edges just touch
- Too wide: low Overlap: high Touch: correct
Goldmann vs NCT DI
Goldmann
- Applanation contact
- Fluorescein mires
- More precise
NCT
- Air puff
- No contact
- Screening tool
- Contact vs air
Tonometer Picker DI
- Precise IOP needed → Goldmann ( Gold standard )
- Screening only → NCT ( Air puff )
- Bedside or supine → Tono-Pen
- Mires too wide → Add force ( Reads low )
- Mires overlap → Reduce force ( Reads high )
- After each patient → Disinfect tip
Tonometry + IOP DI
- IOP normal 10 to 21 mmHg
- Goldmann Applanation gold standard
- Imbert-Fick Flattens 3.06 mm
- Mires touch Correct GAT endpoint
- NCT Air-puff screening
- Tono-Pen Handheld applanation
- Thick cornea Reads falsely high
- Thin cornea Reads falsely low
- Pachymetry Corneal thickness (microns)
A-Scan vs B-Scan DI
A-scan
- One dimension
- Axial length
- IOL calculation
B-scan
- Two dimensions
- Posterior image
- Opaque media
- Measure vs image
Imaging Picker DI
- Retinal layers → OCT
- Glaucoma nerve fiber → OCT RNFL
- Dense media opacity → B-scan
- Document optic disc → Fundus photo
- Vascular leakage → FA
- Count endothelial cells → Specular microscopy
Visual Fields DI
- Static perimetry Fixed points, varied intensity
- Humphrey 24-2 Standard glaucoma pattern
- Humphrey 10-2 Dense central field
- Arcuate scotoma Classic glaucoma defect
- False positive Trigger-happy responses
- False negative Missed seen stimulus
- Fixation loss Eye drifted off
- Mean deviation Overall field loss
OCT vs B-Scan DI
OCT
- Uses light
- Retinal layers
- Clear media
B-scan
- Uses sound
- Penetrates opacity
- Dense cataract
- Light vs sound
Imaging + Instruments DI
- OCT Cross-section retinal layers
- RNFL Nerve fiber thickness
- B-scan Images through opacity
- Fundus photo Retina surface record
- FA Fluorescein leakage study
- Specular microscopy Counts endothelial cells
- Topography Full corneal map
- Slit lamp Magnified segment exam
- Gonioscopy Views drainage angle
- PAM Potential acuity estimate
Keratometry vs Biometry DI
Keratometry
- Corneal curvature
- K readings
- Contact lens cue
Biometry
- Axial length
- IOL planning
- Cataract cue
- Curve vs length
Keratometry + Biometry DI
- Keratometry Central corneal curvature
- K reading Diopters or millimeters
- Distorted mires Irregular corneal surface
- Axial length Front-back eye length
- A-scan Ultrasound axial length
- IOL Master Optical biometry
- SRK/T IOL power formula
- Cup-to-disc Normal 0.3 or less
Drop Order PH
- Watery first, ointment last, wait five
- Aqueous drops first Gels then ointments Space 3-5 minutes
Mydriatic vs Cycloplegic PH
Mydriatic
- Dilates pupil
- Retina view
- Light sensitivity
Cycloplegic
- Stops focusing
- Pediatric refraction
- Blurred near
- Pupil vs focus
Drop Picker PH
- Need dilation → Mydriatic
- Stop accommodation → Cycloplegic
- Numb cornea → Anesthetic
- Child true refraction → Cyclopentolate
- Multiple drops → Wait 3-5 min
- Ointment plus drop → Ointment last
Ophthalmic Pharmacology PH
- Tropicamide Short mydriatic, mild cycloplegic
- Phenylephrine Sympathomimetic dilator
- Cyclopentolate Pediatric cycloplegic
- Atropine Long-acting cycloplegic
- Proparacaine Topical anesthetic
- Timolol Beta-blocker lowers production
- Latanoprost Prostaglandin increases outflow
- Fluorescein Stains corneal defects
- Drop spacing Wait 3-5 minutes
- Punctal occlusion Limits systemic absorption
Tropicamide vs Phenylephrine PH
Tropicamide
- Parasympathetic block
- Mild cycloplegia
- Routine dilation
Phenylephrine
- Sympathomimetic
- No cycloplegia
- Dilator muscle
- Block vs stimulate
Triage Picker PH
- Chemical splash → Irrigate now ( Before paperwork )
- Flashes and floaters → Urgent retina ( Same day )
- Sudden painless loss → Suspect CRAO ( Emergency )
- Before dilation → Check angle depth ( Van Herick )
- Severe eye pain → Alert physician
- Routine refill → Follow policy
Anatomy, Pathology + Triage PH
- Ciliary body Aqueous and accommodation
- Trabecular meshwork Drains aqueous humor
- Endothelium Pumps cornea clear
- Tear film Lipid, aqueous, mucin
- Macula Central detailed vision
- Keratoconus Cone-shaped thinning cornea
- Nuclear cataract Common aging lens
- Glaucoma Optic nerve damage
- Flashes + floaters Urgent retina check
- Chemical burn Irrigate immediately
Aseptic vs Sterile SU
Aseptic
- Prevents contamination
- Technique concept
- Clinical workflow
Sterile
- No living microbes
- Field status
- Surgical standard
- Method vs state
Surgical Assisting SU
- Phacoemulsification Ultrasound emulsifies lens
- Incision 2.2 to 2.8 mm
- OVD Protects corneal endothelium
- Monofocal IOL One focal distance
- Multifocal IOL Distance and near
- PCO Secondary cataract clouding
- YAG capsulotomy Opens cloudy capsule
- Intravitreal Pars plana injection
- Tech role Assist, prep, document
Sterile Technique + Microbiology SU
- Aseptic technique Prevents contamination
- Sterile field No living microbes
- Standard precautions Treat all patients
- Disinfection Kills most pathogens
- Sterilization Kills all microbes
- Autoclave Steam sterilization
- Spore test Confirms sterilization
- Surgical scrub 2 to 3 minutes
- Time-out Confirms correct eye
Common Traps
Exam length
- 200 multiple-choice ≠ Not 100
Two-part exam
- MCQ plus 7 skills ≠ Not MCQ alone
Goldmann endpoint
- Edges just touch ≠ Not overlapping
Thin cornea IOP
- Reads falsely low ≠ Not high
Cover test type
- Cover-uncover finds tropia ≠ Alternate finds total
Ultrasound scans
- A-scan measures ≠ B-scan images
Phenylephrine effect
- Dilates only ≠ No cycloplegia
Drop spacing
- Wait 3-5 minutes ≠ Do not stack
Last Minute
- 1. COT has 200 MCQ
- 2. Skill Evaluation: seven stations
- 3. MCQ time is 180 minutes
- 4. Initial fee is $325
- 5. Diagnostic testing weighs heaviest
- 6. Normal IOP 10 to 21
- 7. Goldmann mires just touch
- 8. Thin cornea reads IOP low
- 9. Snellen top is distance
- 10. RAPD uses swinging light
- 11. Retinoscopy needs no responses
- 12. Lensometer: sphere before cylinder
- 13. Wait five minutes between drops
- 14. Chemical burn: irrigate first
- 15. Recertify every three years
IJCAHPO Certified Ophthalmic Technician
- Practice Questions 100 questions Study Guide 27 topics Cheat Sheet 137 facts Flashcards 50 cards Shorts 1 short Videos 1 video Blogs 2 blogs Free CE Podcast