Cheat sheet
DANB CDA Cheat Sheet
General Chairside
- 39% of exam
- Evaluation Chairside Dentistry Dental Materials Emergencies Procedure Picker
Infection Control
- 31% of exam
- Disease Transmission Cross-contamination Instrument Processing OSHA Sterilization Picker
Radiation Health Safety
- 31% of exam
- Purpose + Technique Radiation Protection Image Errors Digital Sensors Radiograph Picker
Quick Facts
- Exam DANB CDA
- Components GC + ICE + RHS
- Questions 245 MCQ
- Time 195 min
- Testing Pearson VUE
- Scoring CAT scaled
- Pass 400 each component
- Window 60 days
- Credential Renew annually
CDA Components GC
- CDA needs every GIRL component.
- GC ICE RHS Within five years
CDA vs Components GC
CDA
- Credential outcome
- GC + ICE + RHS
- Annual renewal
Components
- Separate exams
- Five-year validity
- Can take separately
- Credential vs exams
Procedure Picker GC
- Need tooth isolation → Dental dam
- Control aerosol → HVE
- Restore proximal wall → Matrix band
- Final prosthesis record → Elastomeric impression
- Preliminary model → Alginate
- Pit protection → Sealant
Eligibility + Logistics GC
- CDA Three component exams
- GC 95 questions
- ICE 75 questions
- RHS 75 questions
- GC time 75 minutes
- ICE time 60 minutes
- RHS time 60 minutes
- Five-year rule Pass all components
- RHS/ICE No eligibility
- GC pathways Three routes
HVE vs Saliva Ejector GC
HVE
- Aerosol control
- High-volume suction
- Assistant operated
Saliva ejector
- Moisture control
- Low-volume suction
- Patient comfort
- Aerosol vs saliva
GC Weights GC
- Evaluation 17%
- Patient management 17%
- Chairside dentistry 50% Heavy
- Dental materials 16%
- Preliminary exam Vitals + histories
- Oral anatomy Teeth + tissues
- Documentation Consent + treatment
- Emergencies Medical complications
Chairside Workflow GC
- Room setup Prepare surfaces
- Tray setup Procedure armamentarium
- Seating Patient position
- Operator zone Dentist access
- Assistant zone Transfer access
- Transfer Instrument exchange
- Dental dam Isolation field
- HVE Aerosol control
- Saliva ejector Moisture control
GC Procedures GC
- Restorative Prep + restore
- Crown Prep + cement
- Bridge Multiunit prosthesis
- Matrix band Wall replacement
- Final impression Prosthetic record
- Suture removal Post-op support
- Sealant Pit protection
- Fluoride Caries prevention
- Dry socket Post-extraction complication
Dental Materials GC
- Alginate Preliminary impression
- Elastomeric Final impression
- Wax Registration pattern
- Amalgam Metal restoration
- Composite Tooth-colored restoration
- Etchant Micromechanical retention
- Bonding agent Adhesive layer
- Glass ionomer Fluoride release
- Gypsum Cast material
Sterilization Flow IC
- Dirty moves one direction only.
- Transport Clean Package Sterilize Store
Critical vs Semicritical IC
Critical
- Penetrates tissue
- Highest risk
- Heat sterilize
Semicritical
- Touches mucosa
- Usually heat sterilize
- HLD if heat-sensitive
- Penetrate vs touch
Sterilization Picker IC
- Penetrates tissue → Heat sterilize ( Critical )
- Touches mucosa → Heat sterilize ( Semicritical )
- Cannot tolerate heat → High-level disinfect
- Touches intact skin → Low-level disinfect ( Noncritical )
- Package is wet → Reprocess
- Routine speed needed → More instrument sets
ICE Weights IC
- Transmission prevention 20%
- Cross-contamination 34% Heavy
- Instrument processing 26%
- OSHA protocols 20%
- Hand hygiene Core protocol
- PPE Barrier protection
- Aerosols Evacuation + barriers
- Medical history Transmission review
OSHA Hazards IC
- Blood and chemicals need plans.
- BBP ECP Sharps HazCom SDS
Clean vs Sterilize IC
Clean
- Remove debris
- Before packaging
- Not final step
Sterilize
- Kill microorganisms
- After packaging
- Validated cycle
- Debris before microbes
Cross-contamination IC
- Clinical contact Touch surfaces
- Housekeeping Low-touch surfaces
- Surface barrier Cover then discard
- Disinfectant EPA-registered product
- Single-use Discard after use
- Unit dose Avoid bulk contamination
- DUWL Waterline biofilm
- Impressions Disinfect before lab
- Biohazard waste Regulated disposal
Barrier vs Disinfect IC
Barrier
- Prevents contamination
- Remove after care
- Useful on touchpoints
Disinfect
- Chemical process
- After contamination
- Follow contact time
- Prevent vs process
Instrument Processing IC
- Transport Covered puncture container
- Clean Remove debris first
- Ultrasonic Safer cleaning
- Package Maintain sterility
- Label Load traceability
- Load Manufacturer IFU
- Monitor Indicators + spores
- Store Dry closed cabinet
- Compromised pack Reprocess before use
OSHA + Safety IC
- BBP Bloodborne pathogens
- ECP Exposure control plan
- Sharps Engineered controls
- Needlestick Post-exposure protocol
- HazCom Chemical hazards
- SDS Chemical safety data
- Secondary label Container identification
- Training records Document compliance
ALARA Memory RH
- Expose only what diagnosis needs.
- Justification Collimation Positioning Retake reduction
Paralleling vs Bisecting RH
Paralleling
- Receptor parallel
- Less distortion
- Preferred method
Bisecting
- Angle bisector
- More distortion risk
- Anatomy workaround
- Parallel beats compromise
Radiograph Picker RH
- See apex → Periapical
- Detect proximal caries → Bitewing
- Full arch survey → Panoramic
- Occlusal localization → Occlusal
- Orthodontic profile → Cephalometric
- Three-dimensional need → CBCT
RHS Weights RH
- Purpose + technique 50% Heavy
- Radiation protection 25%
- RHS infection 25%
- Digital only No film concepts
- Periapical Entire tooth
- Bitewing Interproximal caries
- Panoramic Broad survey
- CBCT Three-dimensional imaging
Radiograph Errors RH
- Overlap is horizontal; length is vertical.
- Overlap Elongation Foreshortening Cone cut
Elongation vs Foreshortening RH
Elongation
- Teeth too long
- Too little vertical
- Increase angle
Foreshortening
- Teeth too short
- Too much vertical
- Decrease angle
- Long up, short down
Error Correction Picker RH
- Contacts overlap → Fix horizontal angle
- Teeth elongated → Increase vertical angle
- Teeth foreshortened → Decrease vertical angle
- Cone cut appears → Align PID
- Image blurred → Stabilize patient
- Image too light → Check exposure
Radiography Technique RH
- Paralleling Preferred intraoral technique
- Bisecting Angle compromise
- Receptor Image capture
- Bite block Stabilizes receptor
- PID Directs x-ray beam
- Central ray Beam center
- Horizontal angle Contact separation
- Vertical angle Length distortion
- Mounting Anatomic orientation
kVp vs mA RH
kVp
- Beam energy
- Penetration
- Contrast influence
mA
- Photon amount
- Exposure intensity
- Density influence
- Energy vs quantity
Radiation Protection RH
- ALARA Minimize exposure
- ALADA Diagnostic dose
- Primary beam Useful radiation
- Scatter Secondary radiation
- kVp Penetrating power
- mA Photon quantity
- Collimation Restrict beam
- Filtration Remove low energy
- Distance Operator protection
- Retake Unnecessary exposure
Image Errors RH
- Underexposed Too light
- Overexposed Too dark
- Cone cut Beam misalignment
- Overlap Horizontal error
- Elongation Low vertical angle
- Foreshortening High vertical angle
- Blur Movement
- Artifact Foreign object
- Reversed plate PSP orientation error
Common Traps
CDA Pass Logic
- One strong component ≠ All components pass
GC Eligibility
- RHS/ICE open access ≠ GC pathway required
Flash Sterilization
- Convenience shortcut ≠ Routine approved method
Surface Workflow
- Barrier removed after care ≠ Barrier reused between patients
Instrument Sequence
- Clean before sterilize ≠ Sterilize visible debris
Radiography Scope
- Digital radiography only ≠ Film chemistry tested
Image Error Cause
- Overlap from horizontal ≠ Overlap from vertical
Radiation Safety
- Retakes add dose ≠ Digital means unlimited retakes
OSHA Documents
- SDS for chemicals ≠ SDS for blood exposure
Last Minute
- 1. CDA = GC + ICE + RHS
- 2. Pass components within five years
- 3. GC chairside dentistry = 50%
- 4. ICE cross-contamination = 34%
- 5. RHS purpose/technique = 50%
- 6. RHS tests digital only
- 7. Clean before package before sterilize
- 8. Critical items penetrate tissue
- 9. Semicritical items touch mucosa
- 10. Wet/torn pack gets reprocessed
- 11. Overlap means horizontal error
- 12. ALARA means minimize exposure
DANB Certified Dental Assistant (CDA)
- Practice Questions 100 questions Study Guide 28 topics Cheat Sheet 115 facts Flashcards 50 cards Shorts 2 short s Videos 2 videos Blogs 5 blogs Free CE Podcast