Cheat sheet
DANB RHS Cheat Sheet
Purpose and Technique
- 50% of exam
- Image Types Technique Basics Image Errors Digital Receptors Image Picker Error Fix Picker
Radiation Characteristics
- 25% of exam
- Exposure Factors Radiation Biology ALARA Protection Dose Units Protection Picker
Infection Prevention
- 25% of exam
- Standard Precautions Spaulding Items Barriers PPE IC Workflow Picker
Quick Facts
- Exam DANB RHS
- Questions 75 MCQ
- Time 60 min
- Pass Scaled 400
- Fee $270 / $265
- Format CAT
- Scope Digital only
- Blueprint Mar 12 2025
Object Localization TE
- SLOB = Same Lingual Opposite Buccal
- Same = lingual Opposite = buccal Tube-shift rule
PA vs Bitewing TE
Periapical
- Full tooth + apex
- Root pathology
- Single-tooth focus
Bitewing
- Crowns in occlusion
- Interproximal caries
- Crestal bone
- Apex vs contacts
Image Picker TE
- Apex / root pathology → Periapical ( PA )
- Interproximal caries → Bitewing ( BW )
- Full dentition baseline → FMS ( PA + BW )
- Broad arch / sialolith → Occlusal
- Third molars survey → Panoramic ( Extraoral )
- Ortho growth planning → Cephalometric
- Implant / 3D anatomy → CBCT
- Paralleling possible → Paralleling ( Preferred )
Image Types TE
- Periapical Crown to apex PA
- Bitewing Crowns + crest BW
- FMS / FMX Full mouth set
- Occlusal Broad arch view
- Panoramic Both jaws survey
- Cephalometric Ortho skull view
- CBCT 3D multiplanar
Domain Weights TE
- Technique 50 | Protection 25 | IC 25
- Half is technique Safety quarter Infection quarter
Paralleling vs Bisecting TE
Paralleling
- Receptor parallel
- Less distortion
- Preferred when possible
Bisecting
- Ray to bisector
- More vertical error
- Shallow palate option
- Preferred vs workaround
Error Fix Picker TE
- Overlapped contacts → Fix horizontal ( Through contacts )
- Teeth too long → Increase vertical ( Elongation )
- Teeth too short → Decrease vertical ( Foreshortening )
- Clear unexposed edge → Center PID ( Cone cut )
- Blurred anatomy → Stabilize patient ( Motion )
- Too light / noisy → Increase exposure
- Too dark / washed → Decrease exposure
- Shallow palate / tori → Modify / bisect
Technique Basics TE
- Paralleling Receptor parallel tooth
- Bisecting Ray to bisector
- PID Aims useful beam
- XCP holder Beam alignment device
- SLOB Same lingual opposite buccal
- Frankfort plane Panoramic head plane
- Central ray Beam centerline
- OFD Object-receptor distance
Vertical Errors TE
- Long = add angle | Short = reduce
- Elongation: increase Foreshorten: decrease
Elongation vs Foreshortening TE
Elongation
- Teeth look longer
- Insufficient vertical
- Increase angulation
Foreshortening
- Teeth look shorter
- Excessive vertical
- Decrease angulation
- Too little vs too much
Image Errors TE
- Overlap Bad horizontal angle
- Elongation Too little vertical
- Foreshortening Too much vertical
- Cone cut Beam missed receptor
- Motion blur Patient/tube moved
- Underexposed Light / noisy
- Overexposed Dark / washed
- Artifact Jewelry / piercings
CCD/CMOS vs PSP TE
CCD / CMOS
- Immediate display
- Wired/wireless sensor
- Barrier only
PSP
- Latent then scan
- Reusable plate
- Scratch-sensitive
- Instant vs scanned
Digital Receptors TE
- CCD Solid-state sensor
- CMOS Solid-state sensor
- PSP Scanned storage plate
- Radiopaque Appears light/white
- Radiolucent Appears dark
- Density Overall blackness
- Contrast Gray-scale range
- Sharpness Edge detail
Operator Controls PR
- ALARA = Time Distance Shielding
- Less time More distance Use barrier
kVp vs mAs PR
kVp
- Beam quality
- Penetration
- Affects contrast
mAs
- Beam quantity
- Density/exposure
- mA × time
- Quality vs quantity
Protection Picker PR
- Need less patient dose → Collimate + filter
- No barrier available → 6 ft + 90-135°
- Track occupational dose → Wear dosimeter
- Avoid retake dose → Correct first exposure
- Patient thyroid concern → Thyroid collar
- Suspected unit leak → Stop + report
Exposure Factors PR
- kVp Beam quality/energy
- mA Beam quantity
- Time Exposure duration
- mAs mA × time
- Filtration Removes soft x-rays
- Collimation Restricts beam size
- Primary Useful tube beam
- Scatter Secondary from matter
Somatic vs Genetic PR
Somatic
- Irradiated person
- Tissue injury risk
- Cancer risk
Genetic
- Reproductive cells
- Future offspring
- Heritable damage
- Self vs offspring
Radiation Biology PR
- Radiosensitive Rapid dividing cells
- Radioresistant Muscle / nerve
- Latent period Delay before effects
- Somatic Effects in person
- Genetic Heritable cell damage
- Gray (Gy) Absorbed dose
- Sievert (Sv) Equivalent/effective
- Inverse square Intensity ∝ 1/d²
ALARA Protection PR
- ALARA Lowest reasonable dose
- Time Minimize near source
- Distance Stand ≥6 feet
- Shielding Barrier / apron
- Thyroid collar Neck scatter shield
- MPD 50 mSv/year occupational
- Dosimeter Badge / TLD monitor
- Rectangular PID Less patient dose
Critical vs Noncritical IN
Critical / Semi
- Tissue / mucosa
- Sterilize holders
- Heat when possible
Noncritical
- Intact skin / surfaces
- Disinfect
- Barriers first
- Sterilize vs disinfect
IC Workflow Picker IN
- Before patient seated → Barriers on surfaces
- Reusable holder → Heat sterilize ( Semi-critical )
- CCD / CMOS sensor → Barrier + disinfect
- After exposure gloves → Remove before keyboard
- Between patients → Disinfect contacts
- PSP after scan → Erase + rebarrier
Standard Precautions IN
- Hand hygiene Before/after contact
- PPE Gloves mask eyewear
- Barriers Cover contact surfaces
- Cross-contamination Dirty to clean spread
- IFU Manufacturer instructions
- Clinical contact Touched during care
Spaulding Items IN
- Critical Sterilize; penetrates tissue
- Semi-critical Heat sterilize holders
- Noncritical Disinfect surfaces
- Sensor barrier Disposable sleeve
- PSP barrier Plate sleeve + erase
- Keyboard barrier Cover input devices
Common Traps
Film vs digital
- RHS is digital-only ≠ No film/darkroom items
Horizontal vs vertical
- Overlap = horizontal ≠ Length = vertical
kVp vs mAs role
- kVp = quality ≠ mAs = quantity
Gy vs Sv
- Gy = absorbed ≠ Sv = biologic effect
Hold receptor myth
- Never hold receptor ≠ Never hold tubehead
Gloves then keyboard
- Remove dirty gloves ≠ Then touch computer
Pan vs bitewing caries
- BW for contacts ≠ Pan is survey only
Last Minute
- 1. Weights: 50 / 25 / 25
- 2. Digital only since Jul 2022
- 3. 75 Q / 60 min / 400
- 4. PA = apex; BW = contacts
- 5. Overlap = horizontal fix
- 6. Long = ↑ vertical; short = ↓
- 7. ALARA: time distance shield
- 8. Stand ≥6 ft at 90-135°
- 9. CCD/CMOS barrier; PSP scan
- 10. Semi-critical holders: sterilize
- 11. Gloves off before keyboard
DANB Radiation Health and Safety (RHS)
- Practice Questions 97 questions Study Guide 36 topics Cheat Sheet 67 facts Flashcards 50 cards Videos 1 video Blogs 1 blog Free CE Podcast