Core

  • 25% of exam
  • 25 questions Certification Rules Environmental Effects Three Rs Safety Current Regulations

Type I Small Appliances

  • 25% of exam
  • 25 questions Five-pound maximum Recovery Percentages Passive Recovery Safe Disposal

Type II Medium to Very-High Pressure

  • 25% of exam
  • 25 questions High Pressure Evacuation Levels Leak Repair Service Practices

Type III Low Pressure

  • 25% of exam
  • 25 questions Low Pressure Centrifugal Chillers Purge Units Freeze Prevention

Quick Facts

  • Universal structure Core + I + II + III
  • Question total 100
  • Questions per part 25
  • Closed-book passing 70%
  • Mail-in Type I passing 84%
  • Universal testing Closed-book and proctored
  • Universal award Pass all four examinations
  • Open-book Core Cannot count toward Universal
  • Certifier EPA-approved organization
  • Federal time limit Not specified
  • Federal exam fee Not specified
  • Credential validity Does not expire
  • Primary rules 40 CFR Parts 82 and 84

Universal Four CO

  • Core | I | II | III
  • Core proctored I small II high III low

Open Core vs Universal Core CO

Open-book Core

  • Type I pathway
  • Mail-in option
  • Cannot count Universal

Universal Core

  • Closed-book
  • Secure and proctored
  • Counts toward Universal
  • Universal requires proctored Core

Certification Picker CO

  • Small factory-charged appliance → Type I ( Five pounds maximum )
  • Medium through very-high pressure → Type II
  • Low-pressure appliance → Type III
  • All Section 608 types → Universal ( All four proctored )
  • Motor vehicle AC → Section 609
  • Registered apprentice → Supervised exemption ( Closely and continually )

Certification and Exam CO

  • Test source EPA question bank
  • Administrator EPA-approved certifying organization
  • Universal questions One hundred total
  • Core Twenty-five questions
  • Type I Twenty-five questions
  • Type II Twenty-five questions
  • Type III Twenty-five questions
  • Closed-book passing Seventy percent
  • Mail-in Type I Eighty-four percent; not Universal
  • Universal conditions Closed-book, secure, proctored
  • Universal award Pass all four examinations
  • Universal route One sitting or combined passes
  • Combined-route condition Every counted part closed-book proctored
  • Open-book Core Invalid toward Universal
  • Expiration Credentials do not expire
  • EPA card role Does not issue cards
  • Time and fee Provider determines both

Three Rs CO

  • Recover | Recycle | Reclaim
  • Remove Clean AHRI 700 Reclaim before transfer

Section 608 vs 609 CO

Section 608

  • Stationary appliances
  • Types I through III
  • Universal available

Section 609

  • Motor vehicle AC
  • Separate training and test
  • MVAC refrigerants
  • Stationary versus motor vehicle

Service Practice Sequence CO

  • Before connecting equipment → Identify refrigerant
  • Opening the circuit → Recover required amount
  • Large charge present → Recover liquid first
  • Recovered refrigerant stays owner → Reuse permitted
  • Refrigerant changes owner → Reclaim first
  • Pressure leak testing → Use regulated nitrogen
  • Charging zeotropic blend → Charge liquid
  • Repair is complete → Evacuate air and moisture

Certification Scope CO

  • Type I Small appliances
  • Type II Medium through very-high pressure
  • Type III Low-pressure appliances
  • Universal All Section 608 types
  • Section 608 Stationary refrigeration equipment
  • Section 609 Motor vehicle air conditioning
  • Technician action Violates refrigerant-circuit integrity
  • Hoses and gauges Technician activity
  • Adding refrigerant Technician activity
  • Removing refrigerant Technician activity
  • Registered apprentice Closely and continually supervised
  • Training class Voluntary, not federally required

Recover vs Recycle CO

Recover

  • Remove refrigerant
  • External container
  • No cleaning required

Recycle

  • Clean refrigerant
  • Oil and moisture removal
  • Equipment reuse
  • Remove versus clean

Environment and Refrigerants CO

  • CFC Chlorine, high ODP
  • HCFC Chlorine, lower ODP
  • HFC Zero ODP, often high GWP
  • R-12 CFC example
  • R-22 HCFC example
  • R-134a HFC example
  • ODP Ozone depletion potential
  • GWP Global warming potential
  • Stratospheric chlorine Catalytically destroys ozone
  • Montreal Protocol International ODS phaseout
  • AIM Act HFC phasedown and management
  • Drop-in replacement No universal substitute exists
  • Oil compatibility Verify refrigerant and lubricant
  • Zeotropic blend Can fractionate

Recycle vs Reclaim CO

Recycle

  • Field cleaning
  • Same-owner use
  • No AHRI certification

Reclaim

  • AHRI 700 purity
  • EPA-certified reclaimer
  • Ownership transfer allowed
  • Reuse versus ownership transfer

Refrigeration Cycle CO

  • Compressor Raises vapor pressure
  • Condenser Rejects heat, forms liquid
  • Metering device Drops refrigerant pressure
  • Evaporator Absorbs heat, forms vapor
  • Receiver Stores high-side liquid
  • Accumulator Protects compressor from liquid
  • Filter-drier Removes moisture and contaminants
  • Sight glass Shows refrigerant condition
  • High-side gauge Red hose
  • Low-side gauge Blue hose
  • psia conversion Add atmospheric pressure
  • Vacuum purpose Removes air and moisture

ODP vs GWP CO

ODP

  • Stratospheric ozone
  • Chlorine matters
  • HFC equals zero

GWP

  • Climate warming
  • HFC can be high
  • CO2 is baseline
  • Ozone impact versus climate impact

Three Rs and Ownership CO

  • Recover Remove into external container
  • Recycle Clean for equipment reuse
  • Reclaim Process to AHRI 700
  • Same owner Reuse across same-owner appliances
  • Ownership changes Reclamation required first
  • Reclaimer EPA-certified processor
  • Mixed refrigerants Avoid cross-contamination
  • Recovery speed Short, large-diameter hoses
  • Liquid recovery Begin before vapor
  • Pressure rebound Wait and recheck

Venting, Sales, and Records CO

  • Intentional venting Generally prohibited
  • De minimis release Good-faith recovery incident
  • Normal operation Permitted, subject to leak rules
  • Exempt substitutes Only EPA-listed uses
  • Refrigerant purchase Matching certification required
  • Stationary refrigerant Section 608 buyer
  • MVAC refrigerant Section 609 buyer
  • Employer purchase Certified employee evidence
  • Wholesaler invoice Buyer, date, quantity
  • Invoice retention Three years
  • Technician copy Keep at business
  • Copy retention Three years after stopping

Refrigerant Safety CO

  • Eye and skin Goggles and gloves
  • Large release Use SCBA if trained
  • Liquid contact Frostbite risk
  • Confined space Oxygen displacement risk
  • High heat Toxic decomposition products
  • Recovery cylinder Gray body, yellow top
  • Cylinder fill Eighty percent maximum
  • Disposable cylinder Never refill
  • Leak-test gas Dry regulated nitrogen
  • Oxygen or air Never pressure-test
  • Nitrogen regulator Required
  • Relief valve Required with nitrogen
  • Shipping cylinder Identify refrigerant and hazard

HFC Management Since 2026 CO

  • Rule 40 CFR Part 84
  • Start date January 1, 2026
  • Refrigerant scope Regulated HFC or qualifying substitute
  • Substitute GWP threshold Greater than fifty-three
  • Full-charge threshold Fifteen pounds or more
  • ODS-only appliance Excluded; Part 82 may apply
  • Comfort and other Ten percent annually
  • Refrigerated transport Ten percent annually
  • Commercial refrigeration Twenty percent annually
  • Industrial process Thirty percent annually
  • Residential light-commercial AC and heat pumps excluded
  • Repair period Thirty days
  • IPR shutdown One hundred twenty days
  • Verification Initial and follow-up tests
  • Retrofit or retire Plan within thirty days
  • Plan completion Within one year
  • Mothballing Pauses applicable timelines
  • Chronic leak 125% requires EPA report
  • Current changes Check EPA Part 84 updates

Small Appliance 90-80-4 TY

  • Working 90 | Dead 80 | Vacuum 4
  • Post-1993 working Dead compressor Four inches Hg

Type I vs Type II TY

Type I

  • Small appliances
  • Five pounds maximum
  • Factory-charged sealed unit

Type II

  • Medium pressure
  • High and very-high pressure
  • Excludes small appliances
  • Charge and appliance type decide

Type I Recovery TY

  • Small appliance Factory-charged, hermetically sealed
  • Charge maximum Five pounds
  • Post-1993 recovery + working Recover ninety percent
  • Pre-1993 recovery equipment Recover eighty percent
  • Dead compressor Recover eighty percent
  • Vacuum alternative Four inches Hg vacuum
  • System-dependent Uses appliance pressure
  • Self-contained Has independent compressor
  • Dead compressor access Use both system sides
  • Working compressor Run during passive recovery
  • Piercing valve Remove after service
  • R-134a Common R-12 substitute

Leak Threshold Ladder TY

  • Comfort 10 | Commercial 20 | Industrial 30
  • 10% comfort 20% commercial 30% industrial

ODS vs HFC Leak Rules TY

Part 82 ODS

  • Fifty-pound charge
  • ODS refrigerant
  • 10/20/30 thresholds

Part 84 HFC

  • Fifteen-pound full charge
  • Substitutes above GWP 53
  • Sector exclusions apply
  • Identify refrigerant and governing rule

Evacuation Picker TY

  • Small post-1993, compressor working → Recover 90%
  • Small pre-1993 recovery equipment → Recover 80%
  • Small compressor inoperative → Recover 80%
  • Small vacuum alternative → Four inches Hg
  • Very-high pressure → Zero inches Hg
  • High under 200 pounds → Zero inches Hg
  • High 200+ post-1993 → Ten inches Hg
  • Medium under 200 post-1993 → Ten inches Hg
  • Medium 200+ post-1993 → Fifteen inches Hg
  • Low-pressure appliance → 25 mm Hg absolute
  • Changing refrigerant oil → Five psig maximum

Required Evacuation Levels TY

  • Equipment date November 15, 1993
  • Very-high, either date Zero inches Hg
  • High under 200 Zero inches Hg
  • High 200+, pre-date Four inches Hg
  • High 200+, post-date Ten inches Hg
  • Medium under 200, pre-date Four inches Hg
  • Medium under 200, post-date Ten inches Hg
  • Medium 200+, pre-date Four inches Hg
  • Medium 200+, post-date Fifteen inches Hg
  • Low-pressure, either date Twenty-five mm Hg absolute
  • Date applies to Recovery equipment manufacture

Leak Rule Picker TY

  • ODS full charge under fifty → No Part 82 leak trigger
  • ODS full charge fifty-plus → Apply 10/20/30 thresholds
  • Part 84 charge under fifteen → No Part 84 leak trigger
  • Part 84 charge fifteen-plus → Check refrigerant and exclusions
  • Residential light-commercial AC → Part 84 leak exclusion
  • Leak exceeds threshold → Repair within thirty days
  • IPR shutdown required → One hundred twenty days
  • Repair completed → Perform verification tests
  • Repair not chosen → Retrofit or retire

Type II Service Practices TY

  • Liquid recovery Recover liquid first
  • System-dependent limit Fifteen pounds unless permanent pump-out
  • Major repair Removes compressor or listed heat exchanger
  • Major opening Over 4 in² beyond fifteen minutes
  • Nonmajor exception No later evacuation to atmosphere
  • Medium/high/very-high nonmajor Zero psig before opening
  • Leaking component Lowest attainable, maximum zero psig
  • Oil change Five psig maximum
  • Hermetic under vacuum Never energize
  • Leak testing Test before recharging
  • Zeotropic blend Charge as liquid
  • Pressure rebound Wait before declaring complete
  • Recovery machine change Prevent cross-contamination
  • ASHRAE 15 Equipment-room safety

ODS Leak Repair TY

  • Rule 40 CFR Part 82
  • Refrigerant scope Ozone-depleting refrigerant
  • Full-charge threshold Fifty pounds or more
  • Comfort cooling Ten percent annually
  • All other appliances Ten percent annually
  • Commercial refrigeration Twenty percent annually
  • Industrial process Thirty percent annually
  • Repair period Thirty days
  • IPR shutdown One hundred twenty days
  • Retrofit plan Create within thirty days
  • Plan completion Within one year
  • Verification Initial and follow-up tests
  • Mothballing Pauses applicable timelines
  • Chronic leak 125% requires EPA report
  • Report deadline March 1 following calendar year

Low-Pressure Numbers TY

  • 25 absolute | heat first | 130°F oil
  • 25 mm Hg Heat before nitrogen Oil at 130°F

Type II vs Type III TY

Type II

  • Above atmospheric operation
  • Leaks move outward
  • High-pressure equipment

Type III

  • Below atmospheric operation
  • Leaks pull inward
  • Low-pressure chillers
  • Operating pressure determines type

Type III Chillers TY

  • Operating pressure Below atmospheric pressure
  • Leak direction Air and moisture enter
  • Excessive purging Leak warning
  • Purge unit Removes noncondensables
  • Recovery target Twenty-five mm Hg absolute
  • Leak pressurization Warm water preferred
  • Nitrogen Second pressurization choice
  • Leak-test maximum Manufacturer limit, below disc
  • Rupture disc Max working pressure relief
  • Low-pressure nonmajor Pressurize no higher than zero psig
  • Recovery sequence Liquid, then vapor
  • Freeze prevention Circulate or remove water
  • Oil removal Heat oil to 130°F
  • Recharge sequence Vapor before liquid
  • Charging valve Evaporator connection
  • Pressure rebound Wait and recheck

Common Traps

Open Core toward Universal

  • Open-book Core cannot count ≠ Universal Core must be proctored

Combined Universal score

  • Pass every required examination ≠ Strong parts do not substitute

Type I size

  • Five pounds is maximum ≠ Factory-charged and sealed

Equipment date

  • Date refers recovery equipment ≠ Not appliance manufacture

Low-pressure vacuum

  • Twenty-five millimeters absolute ≠ Not inches of vacuum

ODS vs HFC leaks

  • ODS trigger starts fifty pounds ≠ Part 84 starts fifteen pounds

Below leak-rule charge threshold

  • Only leak repair is untriggered ≠ Other requirements can still apply

Every hydrocarbon exempt

  • Only EPA-listed uses exempt ≠ Check exact substitute and end-use

Universal covers MVAC

  • Universal covers Section 608 ≠ MVAC generally needs Section 609

Recycle equals reclaim

  • Recycling is field cleaning ≠ Ownership transfer needs reclamation

Fixed federal logistics

  • EPA sets no standard time ≠ Provider controls fees and scheduling

Last Minute

  • 1. Universal = Core + I + II + III
  • 2. Universal Core must be proctored
  • 3. Pass all four examinations individually
  • 4. Closed-book passing = 70%
  • 5. Mail-in Type I passing = 84%
  • 6. Type I maximum = five pounds
  • 7. Working small appliance, 1993+ equipment = 90%
  • 8. Dead compressor = 80%
  • 9. Small vacuum option = four inches Hg
  • 10. High 200+ post-1993 = ten inches
  • 11. Low pressure = 25 mm absolute
  • 12. Oil change = five psig maximum
  • 13. Leak-test with regulated nitrogen
  • 14. Never refill disposable cylinders
  • 15. Never exceed eighty-percent cylinder fill
  • 16. Recover liquid before vapor
  • 17. Ownership transfer requires reclamation
  • 18. ODS leak rule begins fifty pounds
  • 19. Part 84: fifteen-pound full charge
  • 20. Part 84: check GWP and exclusions
  • 21. 608 stationary; 609 motor vehicle
  • 22. Check current EPA Part 84 updates

EPA Section 608 Universal Refrigerant Certification

  • Practice Questions 120 questions Study Guide 33 topics Cheat Sheet 177 facts Flashcards 50 cards Blogs 1 blog Free CE Podcast