Cheat sheet
EPA 609 MVAC Cheat Sheet
Ozone Depletion & Climate
- Not published of exam
- Montreal Protocol ODP vs GWP Stratospheric Ozone UV-B Radiation
Clean Air Act Section 609 Rules
- Not published of exam
- Venting Ban Recordkeeping Sales Restriction Civil Penalties
Refrigerant Types & Properties
- Not published of exam
- R-12 R-134a R-1234yf Label Colors
Recovery, Recycling, Reclamation
- Not published of exam
- Recover vs Recycle Reclaim Cylinder Fill Limit SAE Standards
MVAC Servicing Equipment
- Not published of exam
- Refrigerant Identifier Unique Fittings Leak Detection Evacuation
Safety Procedures
- Not published of exam
- PPE A2L Flammability Frostbite Risk SDS Review
Quick Facts
- Exam EPA 609
- Owner U.S. EPA (CAA Section 609)
- Format Open-book, multiple-choice
- Questions 50 (ESCO) or 25 (MACS)
- Pass score 84%
- Time limit None
- Validity Lifetime, never expires
- Prerequisite None (training required first)
GWP Ladder OZ
- R-1234yf lowest, R-134a middle, CFC-12 highest impact
- R-1234yf: GWP 4 R-134a: GWP 1,430 CFC-12: ODP 1.0
Ozone & Climate Basics OZ
- ODP Ozone depletion potential
- GWP Global warming potential
- CFC-12 ODP 1.0, the reference value
- HFC-134a ODP Zero
- R-1234yf GWP 4 (EPA SNAP value)
- R-134a GWP 1,430
- Montreal Protocol 1987 CFC phaseout treaty
- UV-B radiation Blocked by ozone layer
Ozone Science & Policy OZ
- Chlorine atom Destroys thousands of ozone
- Stratosphere Ozone layer's location
- CAA Title VI Implements Montreal Protocol
- AIM Act 2020 HFC phasedown law
- MY2025 rule Limits new high-GWP HFC-134a
Venting Rule Reminder RE
- Never vent on purpose; accidents only are de minimis
- Intentional venting is a violation Accidental hose loss is fine Never vent recovered gas
Section 608 vs 609 RE
Section 608
- Stationary refrigeration systems
- HVAC/R technicians
- Separate certification
Section 609
- Motor vehicle AC only
- MVAC technicians
- This exam's focus
- Stationary vs mobile systems
Is a Release a Violation RE
- Loss connecting or disconnecting hoses → De minimis, allowed ( Good-faith attempt only )
- Any intentional refrigerant release → Violation ( Any refrigerant class )
- Recovered gas released later → Violation ( No exception applies )
- CO2 (R-744) vented → Allowed under Section 608 ( Still needs 609 cert )
- Paid service, no cert → Violation ( Up to $124,426 per day )
Section 609 Core Rules RE
- Section 609 CAA MVAC technician rule
- Certification trigger Servicing MVAC for payment
- Applies to Every refrigerant type used
- Venting ban No intentional refrigerant release
- De minimis Good-faith hose-loss allowed
- CFC-12 sales Certified techs, under 20 lb
- Records retention 3 years minimum
De Minimis vs Violation RE
De minimis
- Accidental hose-connect loss
- Good-faith recovery attempt
- Allowed by EPA
Violation
- Intentional venting
- Recovered gas released later
- Civil fines apply
- Accidental vs intentional release
Recordkeeping & Penalties RE
- Shop records Tech certs plus reclaim destination
- New shop step Certify equipment to EPA region
- Current max penalty Up to $124,426 per day
- Outdated figure $44,539/day in older guides
- Violation type Civil, per-day, per-violation
- Enforcer EPA Regional Office
Label Color Recall RE
- White is old, blue is common, yf has none
- R-12: white R-134a: sky blue R-1234yf: SAE J639 only
R-134a vs R-1234yf RE
R-134a
- GWP of 1,430
- A1, nonflammable
- Sky blue label
R-1234yf
- GWP of 4
- A2L, mildly flammable
- No mandated label color
- High GWP vs low GWP
Identify Refrigerant By Vehicle RE
- Vehicle made before 1994 → Likely R-12 ( White label )
- Vehicle made 1994 to 2016 → Likely R-134a ( Sky blue label )
- Vehicle model year 2025+ → R-1234yf required ( Low-GWP mandate )
- Label missing or unclear → Run refrigerant identifier ( SAE J1771 device )
- Identifier shows a mix → Treat as contaminated ( Recover only, don't recycle )
Refrigerant Identity RE
- R-12 CFC-12, pre-1994 vehicles
- R-134a HFC-134a, most 1994-2020s vehicles
- R-1234yf HFO, mandated MY2025+ vehicles
- R-744 CO2, rare US natural refrigerant
- Blends Must be SNAP-approved
- Non-SNAP substitute Illegal to use ever
CFC-12 vs HFC-134a RE
CFC-12
- ODP equals 1.0
- Depletes the ozone
- White label
HFC-134a
- ODP equals zero
- High GWP instead
- Sky blue label
- Ozone harm vs climate harm
Label Colors & Fittings RE
- R-12 label White
- R-134a label Sky blue
- R-1234yf label No color; follows SAE J639
- R-134a fitting Quick-connect, size-coded couplers
- R-1234yf high side 17mm OD coupler
- R-1234yf low side 14mm OD coupler
- Adapters Never allowed between refrigerants
Flammability Classification RE
- R-12 class A1, nonflammable
- R-134a class A1, nonflammable
- R-1234yf class A2L, mildly flammable
- A2L meaning Low toxicity, low flammability
The Three Rs RE
- Recover, then recycle, then reclaim for resale
- Recover: remove refrigerant Recycle: on-site cleanup Reclaim: certified resale purity
Recovery vs Recycling RE
Recovery
- Removes refrigerant from system
- No purity requirement
- Always the first step
Recycling
- Cleans refrigerant on-site
- Same-owner reuse only
- Reduces moisture and contaminants
- Remove first, then clean
Recover, Recycle, or Reclaim RE
- Removing refrigerant from system → Recover first ( Always the first step )
- Reusing in same vehicle → Recycle on-site ( No purity standard needed )
- Selling to another owner → Reclaim required ( AHRI 700 purity needed )
- Refrigerant is contaminated → Recover-only unit ( Don't recycle it )
- R-1234yf below 98% purity → Send to reclaimer ( Cannot recycle on-site )
Recover, Recycle, Reclaim RE
- Recovery Remove refrigerant, no purity spec
- Recycling On-site cleanup, same-owner reuse
- Reclamation AHRI 700 purity, resale-ready
- Reclaimer EPA-certified facility only
- Contaminated refrigerant Recover it, don't recycle
- Identifier check Run before recovery, always
Recycling vs Reclamation RE
Recycling
- Stays on-site only
- No purity standard
- Same vehicle or owner
Reclamation
- Meets AHRI 700 purity
- Certified facility required
- Allows resale to others
- On-site vs certified resale
Cylinders & Equipment Standards RE
- Max cylinder fill 80% by weight
- Fill guideline AHRI Guideline K
- R-134a equipment std SAE J2788
- R-1234yf equipment std SAE J2843
- Dual-refrigerant machine std SAE J3030
- Recovery efficiency target 95%, per SAE J2843
- R-1234yf reclaim purity 98% minimum required
Servicing Equipment EQ
- Refrigerant identifier Confirms type before recovery
- Manifold gauge set Refrigerant-specific fittings only
- Vacuum pump Removes air and moisture
- Micron gauge Measures evacuation depth
- UV dye Visible leak trace
- Electronic sniffer Detects refrigerant leaks
- Topping off leak Repair required first
Service Sequence Steps EQ
- Step 1 Identify the refrigerant
- Step 2 Recover the refrigerant
- Step 3 Repair leak or component
- Step 4 Evacuate the system
- Step 5 Charge to specification
- Step 6 Leak-check after recharge
Safety Response By Hazard SA
- Liquid refrigerant touches skin → Flush and treat frostbite ( Not a burn )
- R-1234yf near open flame → Remove ignition source ( A2L flammability risk )
- Working in enclosed space → Ventilate before starting ( Asphyxiation risk )
- Unknown chemical exposure occurs → Consult the SDS ( Before further handling )
PPE & Hazards SA
- Eye protection Goggles for splash risk
- Gloves Prevent refrigerant frostbite burns
- Liquid contact Causes frostbite, not heat burn
- Confined space Oxygen displacement risk
- R-1234yf hazard Mild flammability near heat
- SDS Review before handling refrigerant
- Mixing refrigerants Never mix; fire or pressure hazard
Common Traps
Recovery ≠ Recycling
- Recovery just removes the gas ≠ Recycling cleans it for reuse
Recycling ≠ Reclamation
- Recycling stays on-site only ≠ Reclamation meets resale purity standards
Section 608 ≠ Section 609
- 608 is stationary HVAC/R ≠ 609 is vehicle AC only
GWP ≠ ODP
- GWP measures global warming ≠ ODP measures ozone depletion
De minimis ≠ intentional venting
- De minimis is accidental loss ≠ Intentional venting is always illegal
Lifetime cert ≠ needs renewal
- 609 credential never expires ≠ No periodic renewal required
Topping off ≠ compliant repair
- Topping off ignores the leak ≠ Leak must be repaired first
Last Minute
- 1. Pass score is 84 percent
- 2. 50 questions (ESCO) or 25 (MACS)
- 3. Open-book exam, no time limit
- 4. Certification never expires, ever
- 5. 609 covers MVAC, not stationary HVAC
- 6. Always recover before recycling or reclaiming
- 7. Recycling stays on-site only
- 8. Reclamation needs AHRI 700 purity
- 9. R-1234yf is A2L, mildly flammable
- 10. Never vent refrigerant on purpose
- 11. De minimis is accidental only
- 12. Fittings differ by refrigerant type
EPA 609 MVAC Technician Certification
- Practice Questions 100 questions Study Guide 18 topics Cheat Sheet 76 facts Flashcards 50 cards Videos 1 video Blogs 1 blog Free CE Podcast