Cheat sheet
CFEI Cheat Sheet
Fire Science & Chemistry
- Not published of exam
- Fire Tetrahedron Heat Transfer Combustion Chemistry Combustion Byproducts
Fire Behavior & Dynamics
- Not published of exam
- Compartment Fire Stages Fire Dynamics Variables Flashover Backdraft
Explosion Investigation
- Not published of exam
- Deflagration Detonation BLEVE Flammable Range
Origin Determination & Fire Patterns
- Not published of exam
- Fire Patterns Fire Effects Origin Analysis Scene Examination
Cause Determination
- Not published of exam
- Cause Classifications Ignition Sources Incendiary Indicators Negative Corpus
Evidence Collection & Lab Analysis
- Not published of exam
- Evidence Handling Chain of Custody Lab Analysis GC-MS
Electrical Fire Investigation
- Not published of exam
- Electrical Failures Arc Mapping GFCI Photovoltaic Hazards
Methodology, Legal & Documentation
- Not published of exam
- Scientific Method Legal Standards Documentation Confirmation Bias
Building Systems & Construction
- Not published of exam
- Fire Protection Systems Construction Types Fire Walls Detectors
Quick Facts
- Exam CFEI
- Credential Fire & Explosion Investigator
- Questions 100 MC/True-False
- Time 2 hours
- Pass score 75% (75 of 100)
- Format Closed-book
- Level Professional certification
- Primary reference NFPA 921
Fire Tetrahedron FI
- Fuel + Heat + Oxygen + Chain Reaction
- Fuel: combustible material Heat: ignition energy Oxygen: the oxidizer Chain reaction: sustains burning
Flash Point vs Autoignition Temperature FI
Flash point
- Needs ignition source
- Lower temperature
Autoignition temp
- No spark needed
- Higher temperature
- External spark vs spontaneous
Heat Transfer Mode Picker FI
- Direct object-to-object contact → Conduction
- Hot gas or fluid movement → Convection
- No contact, electromagnetic waves → Radiation
- Fire spreading to nearby exposures → Radiant heat transfer
Fire Tetrahedron & Heat Transfer FI
- Fuel Combustible material
- Heat Ignition energy source
- Oxygen Oxidizer, roughly 16%+
- Chain reaction Self-sustaining combustion process
- Conduction Direct contact heat transfer
- Convection Hot gas or fluid movement
- Radiation EM waves, no contact
Combustion Chemistry & Byproducts FI
- Pyrolysis Heat decomposes solid fuel
- Flash point Lowest vapor-ignites temperature
- Autoignition temperature Ignites without external spark
- Stoichiometric mixture Ideal fuel-to-air ratio
- Heat of combustion Energy released per mass
- Fire load Combustibles per floor area
- Carbon monoxide (CO) Incomplete combustion, most toxic
- Hydrogen chloride (HCl) PVC burning, corrosive gas
Compartment Fire Stages FI
- Ignition, growth, flashover, fully developed, decay
- Order: I-G-F-FD-D Flashover near 1,000°F Decay: fuel or O2 gone
Flashover vs Backdraft FI
Flashover
- Radiant heat feedback
- Full room involvement
Backdraft
- Sudden oxygen introduction
- Ventilation-limited fire
- Heat trigger vs oxygen trigger
Compartment Fire Stages FI
- Ignition Combustion begins
- Growth Fire size increasing
- Flashover ~1,000°F, full room involvement
- Fully developed Peak burning rate
- Decay Fuel or oxygen depleted
- Backdraft Sudden oxygen, explosive ignition
Fire Dynamics Variables FI
- Heat release rate (HRR) kW, key fire variable
- Thermal layering Hot gases stratify at ceiling
- Ventilation-controlled Oxygen-limited burning rate
- Fuel-controlled Fuel-limited burning rate
- Growth rate (alpha) kW/s², fire growth speed
Deflagration vs Detonation EX
Deflagration
- Subsonic propagation
- Most fuel-air explosions
Detonation
- Supersonic shock front
- High explosives
- Speed of propagation
Explosion & Flammable Range EX
- Deflagration Subsonic flame propagation
- Detonation Supersonic shock front
- BLEVE Pressurized vessel ruptures, boils
- LEL Minimum ignitable concentration
- UEL Maximum ignitable concentration
- Propane range 2.1% to 9.5%
- Methane range 5% to 15%
Area of Origin vs Point of Origin OR
Area of origin
- General location
- Room or zone
Point of origin
- Exact spot
- Fuel meets heat source
- General vs specific
Fire Pattern Interpretation OR
- V-shape burn on wall → Trace plume to base
- Irregular pattern on floor → Send sample to lab
- Shiny large char blisters → Rapid heat, not proof
- Multiple unconnected fire origins → Strong incendiary indicator
- Pattern alone, no lab data → Insufficient for cause
Fire Pattern Types OR
- V-pattern Plume rises from base
- Pour pattern Possible liquid, confirm via lab
- Clean burn Soot burned off, intense heat
- Demarcation line Boundary of fire damage
- Alligator char Rapid, intense heat exposure
- Trailer Connects fuel packages, arson sign
Fire Effects & Origin Analysis OR
- Char depth Relative burn duration/intensity
- Calcination Gypsum loses bound water
- Spalling Concrete surface flaking, heat
- Glass fracture Shows force direction, timing
- Arc mapping Plots arcs, shows spread
- Origin matrix Systematic data evaluation tool
- Area of origin General fire start location
- Point of origin Exact ignition location
- Top-down excavation Remove debris layer by layer
- Seat of fire Deepest char, not always origin
Four Cause Classifications CA
- Accidental, natural, incendiary, undetermined, never negligent
- No 'negligent' category exists Undetermined is valid Negative corpus is invalid
Accidental vs Undetermined CA
Accidental
- No deliberate act
- Cause identified
Undetermined
- Cause unknown
- Insufficient evidence
- Known cause vs no cause
Fire Cause Classification Logic CA
- All accidental causes ruled out → Still need positive evidence ( Avoid negative corpus )
- Deliberate act proven → Classify as incendiary
- Lightning or natural event proven → Classify as natural
- No deliberate or natural cause → Classify as accidental
- Insufficient certainty either way → Classify as undetermined
Fire Cause Classifications CA
- Accidental No deliberate human act
- Natural Lightning or natural event
- Incendiary Deliberately set fire
- Undetermined Insufficient certainty either way
- Negative corpus Invalid: elimination alone insufficient
Ignition & Incendiary Indicators CA
- Competent ignition source Sufficient heat and energy
- First fuel ignited Material first set aflame
- Incendiary device Built to start fire
- Multiple origins Strong incendiary indicator
- Total burning Can occur without accelerant
Evidence Handling & Custody EV
- Chain of custody Document all evidence handlers
- Unlined metal cans Airtight ignitable liquid containers
- Comparison samples Unburned baseline material
- Spoliation Evidence destroyed or altered
- Scene safety Always the first priority
Lab Analysis Standards EV
- GC-MS Identifies ignitable liquid residues
- ASTM E1618 GC-MS identification test method
- ASTM E1412 Passive charcoal headspace extraction
- ASTM E1413 Dynamic headspace extraction method
- Passive headspace Charcoal strip absorbs vapors
Electrical Failure Types EL
- Short circuit Current takes unintended path
- Overcurrent Exceeds conductor rating
- Ground fault Current flows to ground
- High-resistance connection Loose joint, glowing heat
- Arc bead Melted copper, arc evidence
Electrical Safety & Systems EL
- GFCI Trips at ~5 milliamps
- Circuit breaker Overcurrent protection device
- PV systems Energized whenever exposed to light
- Overload Excess current generates heat
NFPA 921 Scientific Method LE
- Recognize, define, collect, analyze, hypothesize, test, select
- Seven steps in order Test before selecting Reject unsupported hypotheses
Daubert vs Frye LE
Daubert
- Federal standard
- Reliability plus methodology test
Frye
- Some state courts
- General acceptance test
- Federal vs some states
Warrantless Entry Timing Rules LE
- During active fire suppression → No warrant needed
- Reasonable time after extinguishment → No warrant needed
- Investigators already left scene → Need consent or warrant
- Criminal evidence beyond origin/cause → Need criminal search warrant
Scientific Method Steps LE
- Recognize need Step 1: identify problem exists
- Define problem Step 2: scope the question
- Collect data Step 3: gather evidence
- Analyze data Step 4: evaluate evidence
- Develop hypothesis Step 5: propose explanation
- Test hypothesis Step 6: check against data
- Select final hypothesis Step 7: accept supported theory
Legal Standards & Cases LE
- Michigan v. Tyler Warrantless post-fire entry allowed
- Michigan v. Clifford Re-entry needs consent or warrant
- Daubert standard Federal expert testimony test
- Frye standard General scientific acceptance test
- Preponderance Civil standard, more likely than not
- Beyond reasonable doubt Criminal case standard
Documentation & Bias LE
- Photo sequence Overall scene to close-up
- Scale reference Shows true evidence size
- Baseline method Measure along fixed reference line
- Scene diagram Scaled spatial evidence layout
- NFIRS National fire incident database
- Confirmation bias Favoring pre-existing conclusion
Fire Wall vs Fire Barrier BU
Fire wall
- Structural element
- Between buildings/sections
Fire barrier
- Non-structural element
- Within one building
- Structural vs non-structural
Fire Protection Systems BU
- Fusible link Melts, releases sprinkler water
- Ionization detector Faster on flaming fires
- Photoelectric detector Faster on smoldering fires
- Fire damper Closes duct when heated
- Central station 24/7 off-site monitoring
Construction Types & Barriers BU
- Type I Fire-resistive, non-combustible
- Type III Ordinary construction
- Type IV Heavy timber construction
- Type V Wood frame construction
- Fire wall Structural, between buildings
- Fire barrier Non-structural, within one building
Common Traps
Patterns ≠ Proof of Accelerant
- V-pattern alone is insufficient ≠ Must confirm via lab test
Negative Corpus ≠ Valid Method
- Elimination isn't affirmative proof ≠ NFPA 921 explicitly rejects this
Seat of Fire ≠ Origin
- Deepest char can mislead ≠ Ventilation affects burn location
Total Burning ≠ Accelerant Proof
- Ventilated fires burn completely ≠ Ordinary combustibles alone suffice
Frye ≠ Daubert Standard
- Different jurisdictions apply each ≠ Don't assume they're identical
Alligator Char ≠ Accelerant Proof
- Shows intense heat only ≠ Any well-ventilated fire produces it
Last Minute
- 1. 100 questions, 2-hour time limit
- 2. 75% passing score required
- 3. Closed-book: no outside references allowed
- 4. NFPA 921 is primary reference
- 5. Scene safety is always first
- 6. Use scientific method, test hypotheses
- 7. Avoid negative corpus reasoning
- 8. Four causes exist, no 'negligent'
- 9. V-patterns alone don't prove accelerant
- 10. Chain of custody must be unbroken
- 11. Undetermined is a valid conclusion
- 12. Match confidence level to evidence
NAFI Certified Fire and Explosion Investigator (CFEI)
- Practice Questions 110 questions Study Guide 54 topics Cheat Sheet 108 facts Flashcards 50 cards Shorts 1 short Videos 1 video Blogs 1 blog 1 Job Wiki Free CE Podcast