Cheat sheet

ICC B3 Building Plans Examiner Cheat Sheet

Practice this exam

General Administration

  • 5% of exam
  • Chapter 1 Administration Construction Documents Certificate of Occupancy Means of Appeals

Building Planning

  • 21% of exam
  • Occupancy + Construction Type Height + Area Tables Exterior Walls + Accessibility Construction Type Picker Height Limit vs Area Limit

Footings and Foundations

  • 8% of exam
  • Soils + Foundations Concrete Reference Standard Frost Protection IBC vs ACI 318-19

Floor Construction

  • 4% of exam
  • Floor Systems Live Loads Concrete Slabs Wood Framing

Wall Construction and Coverings

  • 12% of exam
  • Wall Systems Masonry Steel Walls Wood Walls

Roof/Ceiling Construction

  • 4% of exam
  • Roof Systems Roof Coverings Class A Class C

Public Safety and Special Construction

  • 46% of exam
  • Egress Sizing Exit Arrangement Fire-Resistance Construction Fire Alarms + Sprinklers Finishes + Safety Glazing Fire Separation Picker

Quick Facts

  • Exam ICC B3
  • Credential Building Plans Examiner
  • Questions 80 multiple-choice
  • Time 3.5 hrs (210 min)
  • Pass Scaled score 75
  • Format Open book
  • Delivery ICC PRONTO
  • Fee $320 ($255 members)
  • References IBC, Concrete Manual, ACI 318-19

Chapter 1 Administration GE

  • Section 107 Construction documents required
  • Section 109 Permit fees
  • Section 110 Required inspections
  • Section 111 Certificate of occupancy
  • Section 113 Means of appeals
  • Section 114 Code violations
  • Section 115 Stop work order

Height Area Hierarchy BU

  • 504.3=height | 504.4=stories | 506.2=area
  • 504.3: feet above grade 504.4: stories above grade 506.2: allowable area factor

Height Limit vs Area Limit BU

Height (504.3/504.4)

  • Feet + stories
  • By construction type

Area (506.2)

  • Square feet per story
  • Frontage increases allowed
  • Vertical vs horizontal limit

Construction Type Picker BU

  • Need max fire rating → Type I-A ( 3-hr frame )
  • Budget wood frame ok → Type V-B ( 0-hr frame )
  • Mass timber high-rise → Type IV-A ( Up to 18 stories )
  • Need area increase → Check frontage ( Section 506.3 )
  • Multiple occupancies → Section 508 ( Separated or nonseparated )

Occupancy + Construction Type BU

  • Chapter 3 Occupancy classification
  • Chapter 6 Five construction types
  • Type I-A 3-hour frame rating
  • Type V-B 0-hour frame rating
  • Section 508 Mixed occupancy rules

Height + Area Tables BU

  • Table 504.3 Max height, feet
  • Table 504.4 Max stories above grade
  • Table 506.2 Allowable area factor
  • NS No sprinkler system
  • S1 Sprinklered, one story
  • Section 506.3 Frontage area increase

Exterior Walls + Accessibility BU

  • Chapter 14 Exterior wall coverings
  • Chapter 11 Accessibility scoping only
  • Section 1104 Accessible route
  • ICC A117.1 NOT an approved reference
  • Chapter 12 Interior environment

IBC vs ACI 318-19 FO

IBC Chapter 19

  • Adopts by reference
  • IBC-specific modifications

ACI 318-19

  • Base concrete standard
  • Design + construction rules
  • Adopting code vs standard

Soils + Foundations FO

  • Chapter 18 Soils and foundations
  • Section 1809.5 Frost protection required
  • Section 1807 Foundation and retaining walls
  • Table 1806.2 Presumptive bearing values

Concrete Reference Standard FO

  • Chapter 19 IBC concrete chapter
  • Section 1901.2 Design per ACI 318
  • ACI 318-19 Approved B3 reference
  • Concrete Manual Approved B3 reference
  • Shotcrete Special concrete provisions

Floor Systems FL

  • Table 1607.1 Minimum live loads
  • Offices 50 psf live load
  • Residential units 40 psf live load
  • Assembly, fixed seats 60 psf live load
  • Library stacks 150 psf live load
  • Chapter 19 Concrete floor slabs

Wall Systems WA

  • Chapter 21 Masonry wall systems
  • Chapter 22 Steel wall systems
  • Chapter 23 Wood wall framing
  • Chapter 14 Exterior wall coverings
  • Veneer Anchored masonry veneer

Roof Systems RO

  • Chapter 15 Roof assemblies chapter
  • Table 1505.1 Roof covering classification
  • Class A Most fire-resistant covering
  • Class C Least fire-resistant covering
  • Roof drainage Chapter 15 scuppers

Five Fire Separations PU

  • Wall=strongest | Barrier=vertical | Partition=corridor | Smoke=air only
  • Fire wall: standalone structure Fire barrier: shafts/stairs Fire partition: corridors Smoke barrier: I-2/I-3

Fire Wall vs Fire Barrier PU

Fire Wall

  • Independent structural stability
  • Separates buildings
  • Section 706

Fire Barrier

  • Protects shafts/stairs
  • Vertical fire-resistant
  • Section 707
  • Standalone vs component

Egress Width Picker PU

  • Sizing a stairway → 0.3 in/occupant
  • Sizing a corridor → 0.2 in/occupant
  • Sprinklered + voice alarm → Reduce factor ( 0.15 or 0.2 )
  • Occupant load over 49 → Provide 2 exits
  • Common path too long → Add second exit ( Table 1006.2.1 )
  • Need travel distance limit → Table 1017.2

Egress Sizing PU

  • Table 1004.5 Occupant load factors
  • Business areas 150 gross sf/occupant
  • Assembly, unconcentrated 15 net sf/occupant
  • Stairways 0.3 in per occupant
  • Other components 0.2 in per occupant
  • Section 1006.2.1 Common path limits

Egress Width Factors PU

  • Stairs=0.3 in | Other=0.2 in | Sprinklered=0.15-0.2 in
  • Stairways: 0.3 in/occupant Other components: 0.2 in Sprinklered: factor drops

Fire Partition vs Smoke Barrier PU

Fire Partition

  • Rates corridor walls
  • 1-hour typical
  • Section 708

Smoke Barrier

  • Limits smoke spread
  • I-2/I-3 compartments
  • Section 709
  • Fire rating vs smoke control

Fire Separation Picker PU

  • Separate buildings on one lot → Fire wall ( Section 706 )
  • Enclose exit stairway → Fire barrier ( Section 707 )
  • Rate a corridor wall → Fire partition ( Section 708 )
  • Compartmentalize I-2/I-3 smoke → Smoke barrier ( Section 709 )
  • Limit smoke only → Smoke partition ( Section 710 )

Exit Arrangement PU

  • Table 1017.2 Travel distance limits
  • Group B 200 to 300 ft
  • Section 1011.5.2 Stair riser and tread
  • Max riser 7 inches
  • Min tread 11 inches
  • Section 1020.3 Corridor width rule

Occupant Load Memory Line PU

  • Business 150 | Mercantile 60 | Assembly 15 | Warehouse 500
  • Business: 150 gross sf Mercantile: 60 gross sf Assembly unconcentrated: 15 net sf Warehouses: 500 gross sf

Travel Distance vs Common Path PU

Travel Distance

  • Full route to exit
  • Table 1017.2

Common Path

  • Before 2 directions exist
  • Table 1006.2.1
  • Total path vs first segment

Finish Class Picker PU

  • Exit stairwell finish → Class A or B typical ( Verify Table 803.13 )
  • Need most fire resistant → Class A ( FSI 0-25 )
  • Hazardous glazing location → Safety glazing ( Section 2406.4 )
  • Need fire door rating → Table 716.1(2)

Fire-Resistance Construction PU

  • Table 601 Rating by element
  • Table 705.5 Rating by separation
  • Section 706 Fire walls
  • Section 707 Fire barriers
  • Section 708 Fire partitions
  • Section 709 Smoke barriers
  • Section 710 Smoke partitions

Class A vs Class C Finish PU

Class A

  • FSI 0-25
  • Most restrictive

Class C

  • FSI 76-200
  • Least restrictive
  • Exits need stricter class

Fire Alarms + Sprinklers PU

  • Section 903.2 Sprinkler triggers
  • Section 903.2.8 All Group R areas
  • Section 907.2 Fire alarm triggers
  • Section 907.2.1 Group A, 300+ occupants
  • Table 716.1(2) Fire door ratings

Finishes + Safety Glazing PU

  • Table 803.13 Finish class by location
  • Class A FSI 0-25
  • Class B FSI 26-75
  • Class C FSI 76-200
  • Section 2406.4.1 Glazing in doors
  • Section 2406.4.5 Wet surfaces, under 60 in

Common Traps

Scaled score vs percent correct

  • 75 is scaled score ≠ Not 75% raw correct

A117.1 is not approved

  • Approved refs: IBC + ACI ≠ A117.1 is not listed

Common path vs travel distance

  • Common path ends at choice ≠ Travel distance ends at exit

Fire wall vs fire barrier

  • Wall is standalone structure ≠ Barrier protects shafts/stairs

ICC PRONTO not Pearson VUE

  • B3 delivered via PRONTO ≠ Older guides say Pearson VUE

Height table vs area table

  • 504.3/504.4 give feet/stories ≠ 506.2 gives allowable area

Last Minute

  • 1. 80 Qs, 210 min, open book
  • 2. Pass = scaled score 75, not 75%
  • 3. References: IBC, Concrete Manual, ACI 318-19
  • 4. A117.1 is NOT an approved reference
  • 5. Delivery: ICC PRONTO, not Pearson VUE
  • 6. Public Safety = 46% of exam
  • 7. Building Planning = 21% of exam
  • 8. Stairs 0.3 in; other 0.2 in
  • 9. Common path limits: Table 1006.2.1
  • 10. Travel distance up to 400 ft
  • 11. Corridor fire rating: Table 1020.2
  • 12. Max riser 7 in
  • 13. Min tread 11 in
  • 14. Sprinklers = 903.2; alarms = 907.2