General Administration
- 39% of exam
- Permit Lifecycle Fees & Valuation Inspections & CO Customer Service Application Intake
Plans and Documents
- 25% of exam
- Occupancy Groups Construction Types Plan Review Basics Maps & Scales
Legal Aspects
- 22% of exam
- Public Records Appeals & Enforcement Records Research Liability Disclosure
Zoning & Site Development
- 14% of exam
- Zoning & Site Terms Site Plan Review Setbacks & Lot Coverage Easements & ROW
Quick Facts
- Exam ICC Exam 14
- Credential Permit Technician
- Questions 60 MC
- Time 2 hours
- Pass Scaled 75
- Format Open-book
- Level Entry-level
- Codes 2021 IBC/IZC
Domain Weight Order GE
- 39% Admin 25% Plans 22% Legal 14% Zoning
- Admin biggest at 39% Plans second at 25% Legal third at 22% Zoning smallest at 14%
Permit vs Permit Exemption GE
Permit Required
- Structural plumbing electrical work
- Needs application plus fee
Permit Exempt
- Minor accessory work only
- No application needed
- Regulated work vs minor work
Is a Permit Required? GE
- New structural work → Permit required ( 105.1 )
- Shed under 200 sq ft → No permit needed ( 105.2 )
- Fence under 7 ft → No permit needed ( 105.2 )
- Retaining wall over 4 ft → Permit required ( 105.2 )
- Deck over 30 in high → Permit required
- Like-for-like water heater → Permit required ( Plumbing )
Permit Lifecycle GE
- Permit Required Regulated work needs permit 105.1
- Shed Exemption 200 sq ft accessory max 105.2
- Fence Exemption Fences up to 7 ft 105.2
- Retaining Wall Permit if over 4 ft 105.2
- 180-Day Rule Unstarted permit expires 105.5
- Extension One 180-day extension max 105.5
180-Day Rule Everywhere GE
- 180 days to start suspend or abandon
- 105.5 permit start clock 105.5 work suspension clock 107.3.4 abandonment clock
CO vs TCO GE
Certificate of Occupancy
- Final approval issued
- Full compliance verified
Temporary CO
- Partial occupancy allowed
- Time-limited conditions apply
- Final vs temporary approval
Which Approval Comes Next GE
- Plans submitted → Plan review ( 107 )
- Plans approved → Permit issuance ( 105 )
- Work in progress → Progress inspections ( 110 )
- Work complete → Final inspection
- Final inspection passes → Certificate of Occupancy ( 111 )
- Occupy before final CO → Request TCO ( 111.3 )
Fees & Valuation GE
- Valuation Total labor materials equipment value 109.3
- Fee Schedule Set by jurisdiction locally 109.2
- Payment of Fees Paid before permit issued 109.1
- Investigation Fee Work-without-permit double fee 109.4
- Related Fees Other agency fees apply 109.5
- Refund Before plan review starts 109.6
Fee Payment Order GE
- Plan fee first then permit fee
- Fee schedule equals 109.2 Permit fee equals issuance Investigation fee equals penalty
Inspections & CO GE
- Inspection Request Owner or contractor schedules inspection 110.3
- Special Inspection Owner hires approved agency Ch 17
- Final Inspection Last inspection before CO
- TCO Temporary occupancy certificate 111.3
- Certificate of Occupancy Required before occupancy begins 111.1
- Reinspection Fee Charged for failed reinspection
Customer Service Skills GE
- Active Listening Confirm customer's real need
- Plain Language Avoid code jargon
- Scope Clarification Define project before intake
- Referral Protocol Route to correct department
Project Application Intake GE
- Completeness Check Verify all required documents
- Licensing Verify Confirm contractor license active
- Signature Authority Owner or authorized agent
- Prerequisite Approvals Zoning or HOA sign-off first
Occupancy Group Letters PL
- A B E F H I M R S U
- A is Assembly B is Business E is Educational R is Residential S is Storage
Plan Review Routing PL
- Commercial occupancy change → Full plan review
- Site plan submitted → Zoning review first ( Zoning domain )
- Structural questions arise → Route to plans examiner
- Scale or measurement unclear → Verify with engineering scale
Occupancy Groups PL
- Group A Assembly A-1 to A-5
- Group B Business professional office
- Group E Educational K-12
- Group F Factory F-1 or F-2
- Group H Hazardous H-1 to H-5
- Group I Institutional I-1 to I-4
- Group M Mercantile retail use
- Group R Residential R-1 to R-4
- Group S Storage S-1 or S-2
- Group U Utility or misc structures
Construction Types PL
- Type I Fire-resistive noncombustible
- Type II Noncombustible lower fire rating
- Type III Exterior noncombustible walls
- Type IV Heavy or mass timber
- Type V Combustible wood frame
Plan Review Basics PL
- Submittal Documents Plans specs engineering data 107
- Deferred Submittal Approved later noted upfront
- Site Plan Shows lot and structure layout
- Structural Plans Load paths and framing
- Occupant Load Factor Table 1004.5 floor area 1004.5
- Review Necessity Determine if review required
Maps & Scales PL
- Plat Subdivided lot map
- Tract Map Larger development boundary map
- Engineering Scale 1 inch equals feet
- Architectural Scale Fractional inch to foot
- Legal Description Formal property boundary text
Appeal vs Variance LE
Appeal
- Disputes code interpretation
- Goes to Board of Appeals
Variance
- Requests zoning deviation
- Goes to zoning body
- Interpretation dispute vs code exception
Dispute or Violation Routing LE
- Disagree with interpretation → File an appeal ( Board 113 )
- Work without permit found → Stop work order ( 114 )
- False info on application → Permit revocation
- Public records request made → Release per retention policy
Public Records & Info LE
- Public Record Permit files open to public
- Records Retention Keep per jurisdiction schedule
- PII Redaction Remove personal data first
- Records Research Verify project history compliance
- Liability Disclosure Give facts not opinions
Records Retention vs Research LE
Records Retention
- How long to keep
- Storage and destruction schedule
Records Research
- Look up project history
- Verify past compliance
- Keeping records vs finding them
Appeals & Enforcement LE
- Board of Appeals Hears code interpretation disputes 113
- Appeal Basis Not for waiving code
- Stop Work Order Halts unsafe unpermitted work 114
- Permit Revocation False info or violation
- Notice of Violation Formal non-compliance notice
Variance vs Nonconforming Use ZO
Variance
- Approved deviation requested
- Applicant seeks exception
Nonconforming Use
- Pre-existing legal use
- No approval needed
- New exception vs grandfathered
Zoning & Site Terms ZO
- Setback Min distance from lot line
- Lot Coverage Percent lot covered by structure
- Easement Right to use another's land
- Right-of-Way Public land for infrastructure
- Variance Approved zoning code deviation
- Nonconforming Use Legal before rezoning occurred
Easement vs Right-of-Way ZO
Easement
- Private land limited use
- Benefits specific party
Right-of-Way
- Public land strip
- For roads and utilities
- Private grant vs public land
Site Plan Review ZO
- Utility Easement Reserved for utility lines
- Encroachment Permit Work in right-of-way
- Site Plan Approval Required before building permit
- Grading Plan Shows elevation and drainage
Common Traps
Permit Exemption ≠ Compliance Waiver
- Exemption skips permit only ≠ Code compliance still required
Appeal ≠ Variance Request
- Appeal disputes interpretation only ≠ Variance requests code exception
CO ≠ Final Inspection Pass
- Inspection is one step ≠ CO is the final document
Easement ≠ Right-of-Way
- Easement is a private grant ≠ ROW is public land
Valuation ≠ Materials Cost Only
- Valuation includes labor and equipment ≠ Not materials cost alone
Investigation Fee ≠ Court Penalty
- Investigation fee is administrative ≠ Court penalties are separate action
Last Minute
- 1. 39% General Administration weight
- 2. 25% Plans and Documents weight
- 3. 22% Legal Aspects weight
- 4. 14% Zoning and Site weight
- 5. 60 questions in 2 hours
- 6. Scaled score of 75 to pass
- 7. Open-book exam: tab your IBC
- 8. Sheds under 200 sq ft exempt
- 9. Permits expire after 180 days
- 10. Know all 10 occupancy groups
- 11. Board of Appeals hears disputes
- 12. Bring a calculator and pencil
ICC Permit Technician (Exam 14)
- Practice Questions 125 questions Study Guide 21 topics Cheat Sheet 72 facts Flashcards 50 cards Free CE Podcast