Cheat sheet
ICC E1 Residential Electrical Inspector Cheat Sheet
General Requirements
- 10% of exam
- IRC Part VIII Map Clearances Working Space Splices Definitions
Services
- 17% of exam
- Service Load Calc Service Conductors Disconnects Grounding Electrode Bonding
Branch Circuits + Feeders
- 28% of exam
- Required Circuits Receptacle Spacing Conductor Ampacity Overcurrent Feeders
Wiring Methods + Distribution
- 21% of exam
- GFCI Locations AFCI Locations Box Fill Cable Support Equipment Ground
Devices, Lighting, Appliances
- 19% of exam
- Lighting Outlets Closet Luminaires Tamper-Resistant Appliance Circuits Wet Location
Swimming Pools
- 5% of exam
- Equipotential Bonding Pool GFCI Underwater Luminaires Pool Clearances Pool Receptacles
Quick Facts
- Exam ICC E1
- Credential Residential Electrical Inspector
- Questions 60 multiple-choice
- Time 2 hours
- Pass Scaled 75 (~45/60)
- Format Open-book
- Fee $199-$249
- Validity 3 years (1.5 CEUs)
- Reference 2024 IRC Chs. 34-43
IRC Electrical Spine GE
- 34 General, 36 Service, 37 Branch
- Ch. 34: general Ch. 36: services Ch. 37: branch/feeder Ch. 38-43: methods
IRC Part VIII Map GE
- Ch. 34 General requirements
- Ch. 35 Definitions
- Ch. 36 Services
- Ch. 37 Branch/feeder Heaviest
- Ch. 38-39 Wiring methods
- Ch. 40-42 Devices/appliances
- Ch. 43 Class 2, low-voltage
Clearances + Working Space GE
- Panel depth 36 in working space
- Panel width 30 in front
- Headroom 6 ft 6 in
- Service over roof 8 ft typical
- Over driveway 12 ft (residential)
- Over public road 18 ft
- Above grade 10 ft min
General Rules GE
- Splices Approved devices/connectors
- Splice location Inside accessible box
- Made electrode GEC 6 AWG copper max
- Conductor material Copper or aluminum
- Ampacity basis 60/75°C terminals
- Identification Grounded = white/gray
Grounding vs Bonding SE
Grounding
- Earth connection
- GEC to electrode
- Stabilize voltage
Bonding
- Joins metal parts
- Fault current path
- EGC continuity
- To earth vs together
Grounding Electrode Picker SE
- Concrete footing rebar → Ufer/CEE ( Preferred )
- Metal water pipe → Bond + electrode ( Within 5 ft )
- Ground rod only → Two rods ( Unless 25 ohm )
- Made electrode GEC → 6 AWG copper ( Max needed )
- Service enclosure → Main bonding jumper ( Neutral-to-can )
- Subpanel → Separate EGC bus ( No N-G bond )
Service Load Calc SE
- General lighting 3 VA per sq ft
- Small appliance 1500 VA x 2
- Laundry 1500 VA circuit
- First 3000 VA 100% demand factor
- 3001-120,000 VA 35% demand factor
- Range Table demand factor
- Dryer 5000 VA or nameplate
- Largest motor Add 25%
Neutral vs EGC SE
Grounded (neutral)
- Carries current
- White/gray
- Insulated
EGC
- No normal current
- Green/bare
- Fault path
- Current vs fault only
Service Equipment SE
- Min service rating 100 A dwelling
- 200 A copper SE 2/0 AWG typical
- Max disconnects Up to 6 motions
- Disconnect location Readily accessible
- SE conductor sizing Per dwelling table
- Grounded conductor Sized to GEC
Grounding + Bonding SE
- GEC To grounding electrode
- EGC Equipment fault path
- Grounded conductor Neutral, current-carrying
- Main bonding jumper Neutral-to-enclosure (service)
- Ground rod 8 ft, two if needed
- Ufer/CEE Concrete-encased electrode
- Metal water pipe Bond within 5 ft
- Neutral-ground bond Service only, once
Required 20 A Circuits BR
- Two SA, one Laundry, one Bath
- 2x small-appliance 1x laundry 1x bathroom Plus dedicated appliances
Service vs Feeder BR
Service
- Utility supply
- Neutral bonded
- Before disconnect
Feeder
- Between panels
- Neutral isolated
- Has EGC
- Source vs distribution
Service vs Feeder vs Branch BR
- Utility to disconnect → Service conductors ( Calc load )
- Panel to subpanel → Feeder ( EGC + neutral )
- Last OCPD to outlet → Branch circuit ( Rated amps )
- Sizing dwelling service → Standard calc ( IRC E3602 )
- 14 AWG copper → 15 A max ( Lighting OK )
- 12 AWG copper → 20 A max ( Recep./SA )
- Subpanel neutral → Isolated ( No bond )
- Service neutral → Bonded ( Main jumper )
Required Branch Circuits BR
- Small-appliance Two 20 A min
- Laundry One 20 A
- Bathroom One 20 A
- Dishwasher Individual circuit
- Disposal Individual circuit
- HVAC Per nameplate
- Range Dedicated 240 V
Wire to Breaker BR
- 14=15, 12=20, 10=30
- 14 AWG: 15 A 12 AWG: 20 A 10 AWG: 30 A Copper, 60°C
Receptacle Spacing BR
- Wall rule 12 ft max spacing
- From opening 6 ft max
- Wall width 2 ft or wider counts
- Kitchen counter 4 ft max apart
- Counter island Min one receptacle
- Hallway 10 ft+ One receptacle
- Bathroom Within 3 ft of basin
Conductor + OCPD BR
- 14 AWG Cu 15 A breaker
- 12 AWG Cu 20 A breaker
- 10 AWG Cu 30 A breaker
- 8 AWG Cu 40 A
- 6 AWG Cu 55 A (60°C)
- Continuous load Max 80% rating
- Fastened appliance Max 50% on shared
GFCI Locations WI
- Bad Girls Often Kiss Boys Causing Laughter
- Bathroom Garage Outdoor Kitchen Basement Crawl space Laundry
GFCI vs AFCI WI
GFCI
- Shock protection
- Wet/grounded areas
- Trips ~5 mA
AFCI
- Arc-fault/fire
- Living areas
- Detects arcing
- Shock vs fire
GFCI vs AFCI Required WI
- Bathroom receptacle → GFCI ( Not AFCI )
- Bedroom circuit → AFCI ( All outlets )
- Kitchen counter recep. → Both ( GFCI + AFCI )
- Garage receptacle → GFCI ( All )
- Outdoor receptacle → GFCI ( Wet rated )
- Within 6 ft of sink → GFCI ( Any sink )
- Unfinished basement → GFCI ( All recep. )
- Living room circuit → AFCI ( All outlets )
GFCI-Required Locations WI
- Bathrooms All receptacles
- Garages All receptacles
- Outdoors All receptacles
- Kitchens Counter-serving receptacles
- Within 6 ft sink GFCI required
- Unfinished basement All receptacles
- Crawl spaces At/below grade
- Laundry areas All receptacles
Box Fill Volumes WI
- 14=2.0, 12=2.25, 10=2.5
- Device yoke: x2 Clamps: x1 Grounds: x1 Largest conductor
AFCI-Required Areas WI
- Scope 120 V, 15/20 A circuits
- Bedrooms AFCI required
- Living/family rooms AFCI required
- Kitchens AFCI required
- Hallways/closets AFCI required
- Laundry areas AFCI required
- Bathrooms Not AFCI required
Box Fill Volume WI
- 14 AWG 2.00 cu in each
- 12 AWG 2.25 cu in each
- 10 AWG 2.50 cu in each
- Internal clamps One conductor allowance
- Each device yoke Two (largest) allowances
- Equipment grounds One allowance total
- Pigtail Not counted
Cable + Support WI
- NM cable Dry interior, dwelling
- NM support Within 12 in box
- NM staple Every 4.5 ft
- Bored holes 1.25 in from edge
- Protect plate Steel where <1.25 in
- EGC required Metal enclosures bonded
Tamper vs Weather Resistant DE
Tamper-resistant
- Shutter mechanism
- Child safety
- Dwelling interior
Weather-resistant
- Corrosion rated
- Damp/wet
- Outdoor use
- Kids vs weather
Required Lighting DE
- Habitable rooms Switched lighting outlet
- Bathrooms/halls Switched lighting outlet
- Stairways Switched both ends
- Outdoor entrances Switched lighting outlet
- Attic/crawl w/ equip Light at access
- Garage Switched lighting outlet
Damp vs Wet Location DE
Damp
- Protected outdoor
- Under eave
- Listed damp
Wet
- Direct exposure
- In-use cover
- Listed wet
- Sheltered vs exposed
Luminaires + Wet DE
- Closet surface incand. 12 in clearance
- Closet recessed 6 in clearance
- Closet LED/fluor. 6 in surface
- Open lamp closet Not permitted
- Wet location fixture Listed wet location
- Damp location Listed damp minimum
Receptacles + Devices DE
- Tamper-resistant Dwelling 15/20 A
- Weather-resistant Damp/wet outdoor
- Outdoor in-use cover Wet location
- Receptacle grounding EGC connected
- Switch in wet box Weatherproof enclosure
- Faceplate Cover finished opening
Pool Equipotential Bond PO
- Bonding conductor 8 AWG solid copper
- Bonded parts Shell, deck, equipment
- Perimeter surface Within 3 ft bonded
- Pump motor Bonded to grid
- Metal fittings Bonded together
- Purpose Reduce voltage gradient
Pool GFCI + Clearances PO
- Pump receptacle GFCI protected
- Within 20 ft GFCI receptacles
- Receptacle distance Min 6 ft from wall
- Underwater luminaire GFCI if >15 V
- Wet-niche max 150 V to ground
- Overhead conductors 22.5 ft over water
Common Traps
GFCI vs AFCI scope
- GFCI = shock/wet ≠ AFCI = arc/living areas
Bathroom protection
- GFCI required ≠ AFCI not required
Neutral vs ground bond
- Bonded at service only ≠ Isolated at subpanel
Grounding vs bonding
- Grounding to earth ≠ Bonding joins metal
Wall vs counter spacing
- Wall: 12 ft / 6 ft ≠ Counter: 4 ft / 2 ft
Code reference
- E1 uses IRC ≠ Not standalone NEC
TR vs WR receptacle
- TR = shutters ≠ WR = weather rated
Last Minute
- 1. E1 = 60 Q, 2 hr, open-book
- 2. Pass = scaled 75, ~45/60
- 3. Reference 2024 IRC Chs. 34-43
- 4. Heaviest domain: branch circuits 28%
- 5. GFCI: bath, garage, outdoor, kitchen
- 6. GFCI within 6 ft of sink
- 7. AFCI: bedrooms, living, kitchen
- 8. Bathroom GFCI yes, AFCI no
- 9. Required circuits: 2 SA, 1 bath
- 10. Wall receptacle 12 ft spacing
- 11. Kitchen counter: 4 ft max apart
- 12. Copper wire: 14=15A, 12=20A
- 13. Box fill 14 AWG = 2.0
- 14. Device yoke counts as two
- 15. Pool bond: 8 AWG solid copper
- 16. Neutral-ground bonded service only
- 17. Min dwelling service 100 A
ICC Residential Electrical Inspector (E1)