ICC E1 Residential Electrical Inspector Cheat Sheet

Practice this exam

General Requirements

  • 10% of exam
  • IRC Part VIII Map Clearances Working Space Splices Definitions

Services

  • 17% of exam
  • Service Load Calc Service Conductors Disconnects Grounding Electrode Bonding

Branch Circuits + Feeders

  • 28% of exam
  • Required Circuits Receptacle Spacing Conductor Ampacity Overcurrent Feeders

Wiring Methods + Distribution

  • 21% of exam
  • GFCI Locations AFCI Locations Box Fill Cable Support Equipment Ground

Devices, Lighting, Appliances

  • 19% of exam
  • Lighting Outlets Closet Luminaires Tamper-Resistant Appliance Circuits Wet Location

Swimming Pools

  • 5% of exam
  • Equipotential Bonding Pool GFCI Underwater Luminaires Pool Clearances Pool Receptacles

Quick Facts

  • Exam ICC E1
  • Credential Residential Electrical Inspector
  • Questions 60 multiple-choice
  • Time 2 hours
  • Pass Scaled 75 (~45/60)
  • Format Open-book
  • Fee $199-$249
  • Validity 3 years (1.5 CEUs)
  • Reference 2024 IRC Chs. 34-43

IRC Electrical Spine GE

  • 34 General, 36 Service, 37 Branch
  • Ch. 34: general Ch. 36: services Ch. 37: branch/feeder Ch. 38-43: methods

IRC Part VIII Map GE

  • Ch. 34 General requirements
  • Ch. 35 Definitions
  • Ch. 36 Services
  • Ch. 37 Branch/feeder Heaviest
  • Ch. 38-39 Wiring methods
  • Ch. 40-42 Devices/appliances
  • Ch. 43 Class 2, low-voltage

Clearances + Working Space GE

  • Panel depth 36 in working space
  • Panel width 30 in front
  • Headroom 6 ft 6 in
  • Service over roof 8 ft typical
  • Over driveway 12 ft (residential)
  • Over public road 18 ft
  • Above grade 10 ft min

General Rules GE

  • Splices Approved devices/connectors
  • Splice location Inside accessible box
  • Made electrode GEC 6 AWG copper max
  • Conductor material Copper or aluminum
  • Ampacity basis 60/75°C terminals
  • Identification Grounded = white/gray

Grounding vs Bonding SE

Grounding

  • Earth connection
  • GEC to electrode
  • Stabilize voltage

Bonding

  • Joins metal parts
  • Fault current path
  • EGC continuity
  • To earth vs together

Grounding Electrode Picker SE

  • Concrete footing rebar → Ufer/CEE ( Preferred )
  • Metal water pipe → Bond + electrode ( Within 5 ft )
  • Ground rod only → Two rods ( Unless 25 ohm )
  • Made electrode GEC → 6 AWG copper ( Max needed )
  • Service enclosure → Main bonding jumper ( Neutral-to-can )
  • Subpanel → Separate EGC bus ( No N-G bond )

Service Load Calc SE

  • General lighting 3 VA per sq ft
  • Small appliance 1500 VA x 2
  • Laundry 1500 VA circuit
  • First 3000 VA 100% demand factor
  • 3001-120,000 VA 35% demand factor
  • Range Table demand factor
  • Dryer 5000 VA or nameplate
  • Largest motor Add 25%

Neutral vs EGC SE

Grounded (neutral)

  • Carries current
  • White/gray
  • Insulated

EGC

  • No normal current
  • Green/bare
  • Fault path
  • Current vs fault only

Service Equipment SE

  • Min service rating 100 A dwelling
  • 200 A copper SE 2/0 AWG typical
  • Max disconnects Up to 6 motions
  • Disconnect location Readily accessible
  • SE conductor sizing Per dwelling table
  • Grounded conductor Sized to GEC

Grounding + Bonding SE

  • GEC To grounding electrode
  • EGC Equipment fault path
  • Grounded conductor Neutral, current-carrying
  • Main bonding jumper Neutral-to-enclosure (service)
  • Ground rod 8 ft, two if needed
  • Ufer/CEE Concrete-encased electrode
  • Metal water pipe Bond within 5 ft
  • Neutral-ground bond Service only, once

Required 20 A Circuits BR

  • Two SA, one Laundry, one Bath
  • 2x small-appliance 1x laundry 1x bathroom Plus dedicated appliances

Service vs Feeder BR

Service

  • Utility supply
  • Neutral bonded
  • Before disconnect

Feeder

  • Between panels
  • Neutral isolated
  • Has EGC
  • Source vs distribution

Service vs Feeder vs Branch BR

  • Utility to disconnect → Service conductors ( Calc load )
  • Panel to subpanel → Feeder ( EGC + neutral )
  • Last OCPD to outlet → Branch circuit ( Rated amps )
  • Sizing dwelling service → Standard calc ( IRC E3602 )
  • 14 AWG copper → 15 A max ( Lighting OK )
  • 12 AWG copper → 20 A max ( Recep./SA )
  • Subpanel neutral → Isolated ( No bond )
  • Service neutral → Bonded ( Main jumper )

Required Branch Circuits BR

  • Small-appliance Two 20 A min
  • Laundry One 20 A
  • Bathroom One 20 A
  • Dishwasher Individual circuit
  • Disposal Individual circuit
  • HVAC Per nameplate
  • Range Dedicated 240 V

Wire to Breaker BR

  • 14=15, 12=20, 10=30
  • 14 AWG: 15 A 12 AWG: 20 A 10 AWG: 30 A Copper, 60°C

Receptacle Spacing BR

  • Wall rule 12 ft max spacing
  • From opening 6 ft max
  • Wall width 2 ft or wider counts
  • Kitchen counter 4 ft max apart
  • Counter island Min one receptacle
  • Hallway 10 ft+ One receptacle
  • Bathroom Within 3 ft of basin

Conductor + OCPD BR

  • 14 AWG Cu 15 A breaker
  • 12 AWG Cu 20 A breaker
  • 10 AWG Cu 30 A breaker
  • 8 AWG Cu 40 A
  • 6 AWG Cu 55 A (60°C)
  • Continuous load Max 80% rating
  • Fastened appliance Max 50% on shared

GFCI Locations WI

  • Bad Girls Often Kiss Boys Causing Laughter
  • Bathroom Garage Outdoor Kitchen Basement Crawl space Laundry

GFCI vs AFCI WI

GFCI

  • Shock protection
  • Wet/grounded areas
  • Trips ~5 mA

AFCI

  • Arc-fault/fire
  • Living areas
  • Detects arcing
  • Shock vs fire

GFCI vs AFCI Required WI

  • Bathroom receptacle → GFCI ( Not AFCI )
  • Bedroom circuit → AFCI ( All outlets )
  • Kitchen counter recep. → Both ( GFCI + AFCI )
  • Garage receptacle → GFCI ( All )
  • Outdoor receptacle → GFCI ( Wet rated )
  • Within 6 ft of sink → GFCI ( Any sink )
  • Unfinished basement → GFCI ( All recep. )
  • Living room circuit → AFCI ( All outlets )

GFCI-Required Locations WI

  • Bathrooms All receptacles
  • Garages All receptacles
  • Outdoors All receptacles
  • Kitchens Counter-serving receptacles
  • Within 6 ft sink GFCI required
  • Unfinished basement All receptacles
  • Crawl spaces At/below grade
  • Laundry areas All receptacles

Box Fill Volumes WI

  • 14=2.0, 12=2.25, 10=2.5
  • Device yoke: x2 Clamps: x1 Grounds: x1 Largest conductor

AFCI-Required Areas WI

  • Scope 120 V, 15/20 A circuits
  • Bedrooms AFCI required
  • Living/family rooms AFCI required
  • Kitchens AFCI required
  • Hallways/closets AFCI required
  • Laundry areas AFCI required
  • Bathrooms Not AFCI required

Box Fill Volume WI

  • 14 AWG 2.00 cu in each
  • 12 AWG 2.25 cu in each
  • 10 AWG 2.50 cu in each
  • Internal clamps One conductor allowance
  • Each device yoke Two (largest) allowances
  • Equipment grounds One allowance total
  • Pigtail Not counted

Cable + Support WI

  • NM cable Dry interior, dwelling
  • NM support Within 12 in box
  • NM staple Every 4.5 ft
  • Bored holes 1.25 in from edge
  • Protect plate Steel where <1.25 in
  • EGC required Metal enclosures bonded

Tamper vs Weather Resistant DE

Tamper-resistant

  • Shutter mechanism
  • Child safety
  • Dwelling interior

Weather-resistant

  • Corrosion rated
  • Damp/wet
  • Outdoor use
  • Kids vs weather

Required Lighting DE

  • Habitable rooms Switched lighting outlet
  • Bathrooms/halls Switched lighting outlet
  • Stairways Switched both ends
  • Outdoor entrances Switched lighting outlet
  • Attic/crawl w/ equip Light at access
  • Garage Switched lighting outlet

Damp vs Wet Location DE

Damp

  • Protected outdoor
  • Under eave
  • Listed damp

Wet

  • Direct exposure
  • In-use cover
  • Listed wet
  • Sheltered vs exposed

Luminaires + Wet DE

  • Closet surface incand. 12 in clearance
  • Closet recessed 6 in clearance
  • Closet LED/fluor. 6 in surface
  • Open lamp closet Not permitted
  • Wet location fixture Listed wet location
  • Damp location Listed damp minimum

Receptacles + Devices DE

  • Tamper-resistant Dwelling 15/20 A
  • Weather-resistant Damp/wet outdoor
  • Outdoor in-use cover Wet location
  • Receptacle grounding EGC connected
  • Switch in wet box Weatherproof enclosure
  • Faceplate Cover finished opening

Pool Equipotential Bond PO

  • Bonding conductor 8 AWG solid copper
  • Bonded parts Shell, deck, equipment
  • Perimeter surface Within 3 ft bonded
  • Pump motor Bonded to grid
  • Metal fittings Bonded together
  • Purpose Reduce voltage gradient

Pool GFCI + Clearances PO

  • Pump receptacle GFCI protected
  • Within 20 ft GFCI receptacles
  • Receptacle distance Min 6 ft from wall
  • Underwater luminaire GFCI if >15 V
  • Wet-niche max 150 V to ground
  • Overhead conductors 22.5 ft over water

Common Traps

GFCI vs AFCI scope

  • GFCI = shock/wet ≠ AFCI = arc/living areas

Bathroom protection

  • GFCI required ≠ AFCI not required

Neutral vs ground bond

  • Bonded at service only ≠ Isolated at subpanel

Grounding vs bonding

  • Grounding to earth ≠ Bonding joins metal

Wall vs counter spacing

  • Wall: 12 ft / 6 ft ≠ Counter: 4 ft / 2 ft

Code reference

  • E1 uses IRC ≠ Not standalone NEC

TR vs WR receptacle

  • TR = shutters ≠ WR = weather rated

Last Minute

  • 1. E1 = 60 Q, 2 hr, open-book
  • 2. Pass = scaled 75, ~45/60
  • 3. Reference 2024 IRC Chs. 34-43
  • 4. Heaviest domain: branch circuits 28%
  • 5. GFCI: bath, garage, outdoor, kitchen
  • 6. GFCI within 6 ft of sink
  • 7. AFCI: bedrooms, living, kitchen
  • 8. Bathroom GFCI yes, AFCI no
  • 9. Required circuits: 2 SA, 1 bath
  • 10. Wall receptacle 12 ft spacing
  • 11. Kitchen counter: 4 ft max apart
  • 12. Copper wire: 14=15A, 12=20A
  • 13. Box fill 14 AWG = 2.0
  • 14. Device yoke counts as two
  • 15. Pool bond: 8 AWG solid copper
  • 16. Neutral-ground bonded service only
  • 17. Min dwelling service 100 A

ICC Residential Electrical Inspector (E1)