Cheat sheet
ICC Residential Plumbing Inspector (P1) Cheat Sheet
General Requirements
- 14% of exam
- Permits Piping Protection Installation & Support Building Damage Testing
Fixtures
- 8% of exam
- Locations Materials & Approvals Installation & Clearances Flow Rates & Temps Faucet Fittings
Water Heaters
- 12% of exam
- Installation T&P Relief Valve Discharge Piping Thermal Expansion Fuel Gas & Venting
Water Supply and Distribution
- 21% of exam
- Materials & Joints Sizing Backflow Prevention Pressure & Volume Water Treatment
Sanitary Drainage
- 23% of exam
- DFU Loading Pipe Sizing & Slope Cleanouts Traps Indirect Waste
Vents
- 22% of exam
- Materials & Grades Sizing Trap-to-Vent Distance Wet & Circuit Vents AAVs
Quick Facts
- Exam ID P1, Residential Plumbing Inspector
- Questions 60 multiple-choice
- Time Limit 2 hours
- Format Open book
- Passing Score Scaled score of 75
- Code Basis 2024 IRC, Chapters 25-33
- Validity 3 years
- Delivery Pearson VUE or ICC PRONTO
IRC Plumbing Chapter Range GE
- Plumbing lives in IRC Chapters 25 through 33
- 25 Admin 26-27 Fixtures 28 Heaters 29 Supply 30 Drainage 31 Vents
DWV Water Test vs Air Test GE
DWV Water Test
- 10 ft head minimum
- Hold 15 minutes
Water Supply Air Test
- 50 psi minimum
- Hold 15 minutes
- Match the test method to system
Testing & Permit Thresholds GE
- DWV water test 10 ft head, hold 15 min
- Water supply air test 50 psi min, hold 15 min
- Permit required example water heater replacement
- Permit exempt example clearing stoppages, stopping leaks
- Notch limit 2x6 stud 25 percent depth, 1-3/8 in
- Bore limit bearing stud 40 percent of stud depth
- Firestop requirement approved system at fire wall
- Modification authority building official grants in writing
- Sleeve at foundation allows movement, seals water entry
Fixture Clearances & Approvals FI
- Water closet side clearance 15 in minimum from obstruction
- Water closet centerline spacing 30 in minimum apart
- Water closet front clearance 21 in minimum clear space
- Fixture approval basis listing, labeling, material standard
- Flow rate control max and min rates verified
- Temperature limiting control at fixture, not heater thermostat
Seismic Strap Memory Aid WA
- Upper third and lower third with four inches over controls
- Upper 1/3 Lower 1/3 4 in above controls SDC D0-D2 + C townhouse
Water Heater Safety Check WA
- T&P valve installed → Verify no isolation valve
- Discharge pipe routed → Check 6 in max height ( no threads, rigid pipe )
- SDC D0-D2 or C townhouse → Require seismic strapping
- Storage tank in attic → Require an approved drain pan
Water Heater Safety Rules WA
- T&P valve isolation never permitted between tank
- T&P discharge height 6 in max above floor
- T&P discharge threads not permitted on end
- T&P discharge pipe rigid, no valve or trap
- Drain pan trigger where leakage could damage building
- Seismic strap zones SDC D0-D2 plus C townhouse
- Seismic strap points upper third and lower third
- Lower strap clearance 4 in above controls
- Thermal expansion trigger closed system, check valve present
Air Gap vs Backflow Preventer WA
Air Gap
- Physical separation
- No moving parts
- Visual verification
Mechanical Backflow Preventer
- Compact, in-line device
- Needs periodic testing
- Fits tight spaces
- Use air gap when space allows
Backflow Protection Selection WA
- Direct cross-connection, high hazard → Reduced pressure principle assembly ( continuous pressure use )
- Air gap achievable at fixture → Install approved air gap ( 2x opening, 1 in min )
- Hose bibb outdoor connection → Atmospheric vacuum breaker
- Boiler with chemical treatment → Air gap or RP assembly
- Irrigation system connection → Device per Table P2902.3
Water Supply & Backflow Rules WA
- Static pressure limit over 80 psi needs PRV
- Air gap sizing 2x opening, 1 in min
- Backflow device table Table P2902.3 by hazard
- Backsiphonage cause supply pressure drops below
- Backpressure cause downstream pressure exceeds supply
- Water hammer fix arrestor near quick-closing valve
- Hose bibb protection atmospheric vacuum breaker required
Backsiphonage vs Backpressure WA
Backsiphonage
- Supply pressure drops
- Vacuum pulls water back
Backpressure
- Downstream pressure rises
- Pushes water upstream
- Match the device to the mechanism
DFU Quick Recall SA
- Lav one, sink two, tub two, WC three or four
- Lav 1 Sink 2 Tub 2 WC 3-4
S-Trap vs P-Trap SA
S-Trap
- Self-siphons on discharge
- Prohibited configuration
P-Trap
- Vented trap arm
- Code-compliant design
- S-trap is prohibited unvented risk
Cleanout Placement Decision SA
- Building drain meets sewer → Cleanout required at junction
- Horizontal branch, 2+ fixtures → Cleanout at the junction
- Direction change over 45 deg → Cleanout at that bend
- Multiple bends within 40 ft → One cleanout serves all
- Long straight horizontal run → Cleanout every 100 ft
Drainage Fixture Unit Values SA
- Water closet, 1.6 gpf 3 DFU
- Water closet, other 4 DFU
- Lavatory 1 DFU
- Bathtub or shower 2 DFU
- Kitchen sink 2 DFU
- Clothes washer standpipe 2 DFU
Drainage Slope & Cleanout Sizing SA
- Slope, 2.5 in or less 1/4 in per ft
- Slope, 3 in or more 1/8 in per ft
- Cleanout max interval 100 ft horizontal run
- Cleanout direction change required over 45 degrees
- Multiple bends in 40 ft one cleanout serves all
- Backwater valve trigger rim below upstream manhole
Traps & Indirect Waste SA
- Trap seal depth 2 in min, 4 in max
- S-trap status prohibited, self-siphons
- Water closet trap size 3 in minimum, no exceptions
- Indirect waste protection air break or air gap
Trap Arm Growth Pattern VE
- Bigger trap arm allows a longer run to the vent
- 1-1/4 in = 30 in 1-1/2 in = 42 in 2 in = 60 in 3 in = 72 in
Wet Vent vs Circuit Vent VE
Wet Vent
- Drain also vents fixtures
- Limited to bathroom group
Circuit Vent
- Vents a fixture battery
- Serves a horizontal branch
- Both need an exact arrangement
Trap-to-Vent Distance Check VE
- Trap arm is 1-1/4 in → Max 30 in to vent
- Trap arm is 1-1/2 in → Max 42 in to vent
- Trap arm is 2 in → Max 60 in to vent
- Trap arm is 3 in → Max 72 in to vent
Vent Sizing & Trap-Arm Distance VE
- Min vent pipe size 1-1/4 in minimum
- Vent-to-drain ratio at least half drain diameter
- Trap arm, 1-1/4 in 30 in max to vent
- Trap arm, 1-1/2 in 42 in max to vent
- Trap arm, 2 in 60 in max to vent
- Trap arm, 3 in 72 in max to vent
AAV vs Open Vent VE
Air Admittance Valve
- Admits air only
- Mechanical, needs access
Open Vent
- Two-way air path
- Connects to outdoors
- AAV never fully replaces open vent
Vent Terminals & Vent Types VE
- Vent terminal height 6 in above roof surface
- Snow climate vent 6 in above snow line
- Terminal near opening 10 ft, or 3 ft above
- Wet vent scope bathroom group, one floor
- AAV limitation no positive-pressure relief path
- Common vent condition method-specific fixture arrangement only
Common Traps
Confusing Trap Seal Limits
- Minimum seal is 2 inches ≠ Maximum seal is 4 inches
S-Trap Looks Like P-Trap
- S-trap self-siphons and fails ≠ P-trap with vent holds seal
Two Different Test Standards
- DWV test needs 10 ft head ≠ Air test needs 50 psi minimum
Mixing Up Backflow Mechanisms
- Backsiphonage is a pressure drop ≠ Backpressure is a pressure push
Assuming AAV Replaces Open Vent
- AAV only admits air in ≠ System still needs outdoor vent
Slope Ratio Varies By Size
- 2.5-in pipe needs 1/4 slope ≠ 3-in pipe needs 1/8 slope
Cleanout Rule Depends On Layout
- Straight runs cleanout every 100 ft ≠ Bend over 45 deg needs cleanout
Last Minute
- 1. Exam is 60 questions total
- 2. Time limit is two hours
- 3. Exam is open book format
- 4. Passing score is 75 scaled
- 5. Trap seal range is 2-4 in
- 6. Min vent size 1-1/4 in
- 7. Pressure over 80 psi needs PRV
- 8. Cleanouts required every 100 feet
- 9. T&P valve must never be isolated
- 10. Bring only approved code references
- 11. Tab your IRC before exam day
- 12. Six attempts allowed per six months