Cheat sheet

IMSA Traffic Signal Field Technician II Cheat Sheet

Practice this exam

Programming and Replacing Equipment

  • Not published of exam
  • Cabinet Equipment Cabinet Standards Controller Programming BIU vs SIU TS 2 Type 1 vs 2

Traffic Signal Troubleshooting

  • Not published of exam
  • Monitor Fault Types Electrical Theory Test Equipment Preventive Maintenance Flash Fault Picker

Traffic Signal Standards

  • Not published of exam
  • MUTCD Essentials Signal Indications Pushbutton Placement Accessible Pedestrian Signals MUTCD Verb Ladder

Operation, Phasing, Timing, Detection

  • Not published of exam
  • Timing Intervals Coordination Terms Detection Types Preemption and Priority Timing Complaint Picker

Installation and Testing

  • Not published of exam
  • Field Devices IMSA Cable Specs Underground and Overhead Work Loop Wire vs Lead-In HAWK vs RRFB

Documentation and Asset Management

  • Not published of exam
  • Records and Assets Plan Reading Closeout Checks Documentation Picker

Quick Facts

  • Exam IMSA Field Technician II
  • Body IMSA
  • Prereq Level I plus two years
  • Questions Not published
  • Time Not published
  • Pass Not published
  • Weights Not published
  • Program Two days
  • Formats Hybrid, virtual, in-person
  • Fee Set by host section
  • Renewal 16 hours, three years
  • Reinstate One year after expiration
  • Registration Closes seven days before
  • Standards MUTCD 11th Edition Revision 1

TS 2 Type 1 vs 2 PR

Type 1

  • All input output serial
  • BIUs for every rack

Type 2

  • Serial monitor and detection
  • A, B, C connectors kept
  • Fully serial versus hybrid

Cabinet Equipment PR

  • Controller unit Runs phase and timing
  • Load switch Powers one signal channel
  • Flasher unit Drives flashing mode output
  • Flash transfer relay Bypasses controller during flash
  • MMU TS 2 malfunction monitor
  • CMU TS 1 conflict monitor
  • BIU TS 2 serial interface
  • SIU ATC cabinet serial interface
  • Detector rack Holds detector amplifier cards
  • Power supply Provides cabinet logic voltages
  • Police panel Manual flash and advance
  • UPS Runs signals during outage

BIU vs SIU PR

BIU

  • NEMA TS 2 cabinets
  • SDLC Port 1 bus

SIU

  • ATC 5301 ITS cabinets
  • Serial bus 1, 2
  • TS 2 versus ATC

Cabinet Standards PR

  • NEMA TS 1 Parallel A, B, C connectors
  • NEMA TS 2 Type 1 Fully serial SDLC cabinet
  • NEMA TS 2 Type 2 Serial monitor, parallel outputs
  • SDLC Port 1 153,600 bps serial bus
  • ATC 5301 ITS cabinet standard
  • Serial bus 1 ATC cabinet SIU bus

Controller Programming PR

  • Database backup Save before any change
  • Phase sequence Order phases are served
  • Channel assignment Load switch to indication
  • Detector assignment Detector mapped to phase
  • Coordination pattern Cycle, split, offset set
  • Time-of-day schedule When each pattern runs
  • Firmware version Record before and after

Flash Fault Order TR

  • Log, channels, load switch, field
  • Log: what tripped Channels: which conflicted Load switch: test output Field: short or crossfeed

MMU vs CMU TR

MMU

  • TS 2 cabinets
  • Reports over Port 1
  • Adds Port 1 timeout

CMU

  • TS 1 cabinets
  • Parallel wiring only
  • No serial diagnostics
  • Serial monitor versus parallel

Flash Fault Picker TR

  • All indications dark → Check service, breaker, power
  • Intersection in flash → Read monitor fault display ( Do not reset first )
  • Fault reads conflict → Compare channels and load switches
  • Fault reads red failure → Test load switch output
  • Fault reads Port 1 timeout → Check SDLC cable, BIUs
  • Flash after program change → Restore backup, verify channels
  • Monitor trips again → Trace field short or crossfeed

Monitor Fault Types TR

  • Conflict Conflicting greens detected together
  • Red failure No active channel output
  • Dual indication Two indications, one channel
  • Clearance failure Yellow shorter than minimum
  • Port 1 timeout SDLC communication lost
  • CVM fault Controller voltage monitor dropped
  • 24V monitor Cabinet logic voltage low
  • Minimum flash Holds flash before restart

Electrical Theory TR

  • Ohm's law V = I x R
  • Power P = V x I
  • Series circuit Same current, resistances add
  • Parallel circuit Same voltage, currents add
  • Voltage drop Current times conductor resistance
  • Multimeter Reads volts, amps, ohms
  • Clamp meter Current without breaking circuit
  • Megohmmeter Tests insulation to ground
  • Service disconnect Isolates cabinet from supply

Test Equipment TR

  • Monitor tester Verifies fault detection response
  • Loop analyzer Reads inductance and resistance
  • Megohmmeter Finds insulation breakdown
  • Ground tester Measures electrode resistance
  • OTDR Locates fiber loss events
  • Optical power meter Measures fiber end-to-end loss
  • Laptop and software Uploads and backs up

Preventive Maintenance TR

  • PM schedule Planned inspection intervals
  • Cabinet cleaning Clear filters and debris
  • Torque check Retighten terminals and hardware
  • Ground test Verify electrode resistance
  • Battery test Confirm UPS runtime, transfer
  • Head inspection Check aim, seals, damage
  • Monitor test Verify fault response periodically

MUTCD Verb Ladder ST

  • Shall, should, may, informational
  • Standard: shall Guidance: should Option: may Support: informational

MUTCD Essentials ST

  • Standard Mandatory statement, uses shall
  • Guidance Recommended statement, uses should
  • Option Permissive statement, uses may
  • Support Informational, no requirement
  • Part 4 Highway traffic signals
  • Part 8 Railroad grade crossings
  • Current edition 11th Edition, Revision 1
  • Revision 1 date December 2025
  • Section 4F.17 Yellow and red clearance
  • Section 4I.06 Pedestrian intervals and phases

Pedestrian Walking Speeds ST

  • 3.5 clearance, 3.0 walk plus clearance
  • 3.5 ft/s: clearance interval 3.0 ft/s: walk plus clearance Measure to far side Slower speed where needed

Signal Indications ST

  • Circular green Permissive, yield when turning
  • Green arrow Protected exclusive movement
  • Flashing yellow arrow Permissive left turn
  • Steady yellow Right of way ending
  • Red clearance All approaches show red
  • Flashing red Stop, then proceed
  • Flashing yellow Proceed with caution

Pushbutton Placement ST

  • Mounting height About 3.5 feet, 4 maximum
  • Activation force No more than 5 pounds
  • From curb face Between 1.5 and 6 feet
  • From crosswalk edge Within 5 feet
  • From curb ramp Within 10 feet
  • Two buttons per corner At least 10 feet apart
  • Clear access route 4-foot minimum continuous width
  • Extended press plaque R10-32P sign required

Accessible Pedestrian Signals ST

  • Locator tone Repeats at 1-second intervals
  • Tone duration 0.15 seconds or less
  • Tone audibility 6 to 12 feet
  • Ambient response Tone tracks background sound
  • Vibrotactile arrow On the pushbutton surface
  • Arrow alignment Parallel to associated crosswalk
  • Speech walk message Names the crossing street
  • Walking speed 3.5 ft/s clearance interval

Preemption Priority Order OP

  • Train, boat, fire, police, rail, bus
  • Train: hardest to stop Boat: movable bridge Fire and EMS next Police, light rail, bus

Preemption vs Priority OP

Preemption

  • Interrupts normal operation
  • Trains and emergency vehicles

Priority

  • Modifies normal operation
  • Transit keeps normal sequence
  • Interrupt versus adjust

Detection Fault Picker OP

  • Loop never calls → Megohmmeter test the lead-in
  • Loop calls constantly → Inspect splice, adjust sensitivity
  • Loop reading drifts → Check pavement cracks, sealant
  • Video misses at night → Check lighting and aim
  • Radar detects wrong lane → Re-aim, redraw detection zone
  • Pushbutton gives no walk → Trace input to controller

Timing Intervals OP

  • Minimum green Shortest green that serves
  • Passage time Extension per detector actuation
  • Maximum green Cap with conflicting call
  • Yellow change 3 to 6 seconds
  • Red clearance Not exceeding 6 seconds
  • Walk Steady walking person interval
  • Pedestrian clearance Flashing upraised hand interval
  • Gap out Detector gap expired
  • Max out Maximum green expired
  • Force off Coordination terminates the phase
  • Recall Call placed without detection

Maximum Preemption Time OP

  • Transfer + queue + separation
  • Transfer: reach track clearance Queue: clear the tracks Separation: clear before arrival Sum: maximum preemption time

Gap Out vs Max Out OP

Gap out

  • Detector gap expired
  • Demand satisfied early

Max out

  • Maximum green expired
  • Conflicting call still waiting
  • Demand ends versus timer

Timing Complaint Picker OP

  • Side street waits long → Verify detection before timing
  • Green ends too early → Review passage time setting
  • Green never ends → Check maximum green, recall
  • Platoon stops each signal → Review offset and cycle
  • Walk time too short → Recalculate using 3.5 ft/s
  • Signals lost coordination → Check time source, pattern

Coordination Terms OP

  • Cycle length One complete phase sequence
  • Split Time allotted per phase
  • Offset Reference start time difference
  • Yield point Coordinated phase may release
  • Permissive period Window to serve phases
  • Bandwidth Usable green through band
  • Time-space diagram Progression plotted against distance
  • Early return to green Coordinated phase starts early

Coordination Parameters OP

  • Cycle, Split, Offset
  • Cycle: full sequence length Split: share per phase Offset: reference start time All three must match

Offset vs Split OP

Offset

  • Reference between signals
  • Tunes corridor progression

Split

  • Share within one cycle
  • Splits sum to cycle
  • Between signals versus within

Detection Types OP

  • Inductive loop Senses inductance change
  • Detector amplifier Converts loop change to call
  • Magnetometer Senses magnetic field change
  • Magnetic detector Moving vehicles only
  • Ultrasonic Sound waves sense presence
  • Infrared Detects heat or reflection
  • Radar Radio waves sense movement
  • LIDAR Laser pulses measure distance
  • Video Image processing detection zones
  • Pedestrian pushbutton Places a pedestrian call

Presence vs Pulse Detection OP

Presence

  • Call held while occupied
  • Used at stop line

Pulse

  • Momentary call output
  • Used for counting
  • Held call versus momentary

Preemption and Priority OP

  • Preemption Interrupts normal signal operation
  • Priority Modifies normal signal operation
  • Priority order Train outranks emergency vehicles
  • Track clearance interval Clears queue off tracks
  • Right-of-way transfer time Time before track clearance
  • Queue clearance time Time to clear track
  • Separation time Track clear before arrival
  • Maximum preemption time Transfer, queue, separation combined
  • Advance preemption Notice before warning devices activate
  • Simultaneous preemption Signal and crossing notified together
  • EVP Emergency vehicle preemption
  • TSP Transit signal priority

IMSA Cable Numbers IN

  • 19-1 signal, 50-2 lead-in, 51 loop
  • 19-1: traffic signal cable 20-1: traffic signal cable 50-2: loop lead-in 51-5 and 51-7: loop wire

Loop Wire vs Lead-In IN

Loop wire

  • IMSA 51-5 or 51-7
  • Sits in sawcut slot

Lead-in

  • IMSA 50-2 cable
  • Runs conduit to cabinet
  • Pavement versus conduit

Field Devices IN

  • Mast arm Rigid arm on pole
  • Span wire Signals hung on messenger
  • Strain pole Anchors span wire tension
  • Flashing beacon Warning or stop beacon
  • Pedestrian hybrid beacon HAWK, dark until actuated
  • RRFB Rectangular rapid flashing beacon
  • Backplate Improves signal head contrast
  • Pedestrian head Walk and clearance indications
  • Signal head hardware Brackets, clamps, disconnect hangers

HAWK vs RRFB IN

Pedestrian hybrid beacon

  • Dark until actuated
  • Displays steady red indication

RRFB

  • Flashing yellow only
  • Never displays red indication
  • Stops traffic versus warns

Underground and Overhead Work IN

  • Raceway Protected conductor pathway
  • Pull box Access for pulling conductors
  • Foundation Resists pole overturning loads
  • Conduit fill 40 percent, over two conductors
  • Splice Listed connector, insulation restored
  • Termination Landed, torqued, labeled conductor
  • Grounding NEC Article 250 rules
  • Drip loop Prevents water tracking inside
  • Pole plumb Verify after final torque

IMSA Cable Specs IN

  • IMSA 19-1 Traffic signal cable
  • IMSA 20-1 Traffic signal cable
  • IMSA 50-2 Loop detector lead-in
  • IMSA 51-5 Loop detector wire
  • IMSA 51-7 Loop detector wire
  • IMSA 19-6 Aerial or direct burial

Documentation Picker DO

  • Before changing timing → Back up controller database
  • After rewiring a cabinet → Redline the cabinet print
  • Field differs from plan → Record as-built, notify agency
  • Repair finished → Close work order, list parts
  • Unsafe condition remains → Secure site, notify authority

Records and Assets DO

  • As-built plan Field condition after construction
  • Timing sheet Approved controller timing values
  • Cabinet print Wiring and channel assignments
  • Work order Authorized task and closeout
  • Asset record Equipment, location, condition, history
  • Database backup Restorable controller configuration
  • Fault log Monitor and controller events
  • Retention Supports agency liability defense

Plan Reading DO

  • Phase diagram Movements assigned to phases
  • Conductor schedule Wire counts per run
  • Pole schedule Arm length and mounting
  • Quantity sheet Pay items and counts
  • Detail sheet Standard construction drawings
  • Legend Symbol meanings on plans

Closeout Checks DO

  • Functional test Verify every affected movement
  • Flash test Confirm required flash indications
  • Detection test Confirm calls reach controller
  • Photo record Document final field condition
  • Timing sheet update Match record to field
  • Notification Inform agency and dispatch

Common Traps

Preemption vs priority

  • Preemption interrupts the sequence ≠ Priority only adjusts timing

MMU vs conflict monitor

  • MMU reports over Port 1 ≠ Conflict monitor has no bus

Offset vs split

  • Offset links adjacent signals ≠ Split divides one cycle

Gap out vs max out

  • Gap out means demand ended ≠ Max out means timer expired

HAWK vs RRFB

  • HAWK displays a red indication ≠ RRFB flashes yellow only

Loop wire vs lead-in

  • Loop wire sits in sawcut ≠ Lead-in runs through conduit

Detection vs timing fault

  • Check detection before retiming ≠ Bad detector mimics timing complaint

Dark vs flash

  • Dark means power is lost ≠ Flash is a controlled state

Yellow vs pedestrian intervals

  • Preempt cannot shorten yellow ≠ Preempt may shorten walk

Vehicle vs track clearance

  • Red clearance frees the intersection ≠ Track clearance empties the crossing

Last Minute

  • 1. Prereq: Level I plus two years
  • 2. Renewal: 16 hours every three years
  • 3. Reinstate within one year of expiration
  • 4. Yellow change: 3 to 6 seconds
  • 5. Red clearance: 6 seconds maximum
  • 6. Pedestrian clearance uses 3.5 ft/s
  • 7. MMU = TS 2 monitor
  • 8. CMU = TS 1 monitor
  • 9. Preemption interrupts; priority only adjusts
  • 10. Trains outrank emergency vehicle preemption
  • 11. Gap out ends on demand
  • 12. Max out ends on timer
  • 13. Offset links signals; split divides cycle
  • 14. IMSA 50-2 = loop lead-in
  • 15. IMSA 19-1 = traffic signal cable
  • 16. Back up database before programming
  • 17. MUTCD: shall mandatory, should recommended
  • 18. Fee is set by section

IMSA Traffic Signal Field Technician Level II

  • Practice Questions 124 questions Study Guide 41 topics Cheat Sheet 174 facts Flashcards 50 cards 1 Job Wiki Free CE Podcast

Same family resources

  • Explore More IMSA Traffic Signal Technician
  • Continue into nearby exams from the same family. Each card keeps practice questions, study guides, flashcards, videos, and articles in one place.

IMSA Traffic Signal Technician Level I

  • Cheat Sheet 114 facts Practice Questions 160 questions Study Guide 16 topics Flashcards 50 cards Shorts 1 short 1 Job Wiki Free CE

IMSA Traffic Signal Senior Field Technician Level III

  • Practice Questions 124 questions Study Guide 55 topics 1 Job Wiki Free CE

IMSA Traffic Signal Bench Technician Level II

  • Practice Questions 100 questions 1 Job Wiki Free CE

IMSA Traffic Signal Construction Technician Level II

  • Practice Questions 100 questions Shorts 1 short Free CE

IMSA Traffic Signal Inspector

  • Practice Questions 100 questions Free CE