Cheat sheet
IA CIT Cheat Sheet
Understanding Basic Irrigation Principles
- 41-46% of exam
- Sprinklers + Nozzles Backflow Functionality Pipe + Pressure Ratings Pumps + Water Supplies Job Safety Startup + Winterization
Understanding Electrical Principles
- 28-32% of exam
- Voltmeter Operation Controllers + Transformers Solenoids + Field Wiring Wire Tracking + Splices Zone Will Not Start
Understanding Hydraulic Principles
- 26-27% of exam
- Pressure + Flow Testing Valves Sensors Drip Mechanics Friction Loss Charts
Quick Facts
- Exam CIT
- Credential Certified Irrigation Technician
- Body Irrigation Association
- Questions 100 multiple choice
- Weighting All items weighted equally
- Time 3 hours
- Pass Unannounced; typically 68-72%
- Delivery Computer-based testing centers
- Languages English and Spanish
- Fee $175 member / $300 nonmember
- Experience 6 months or 1,000 hours
- Register by 14 days before exam
- Bring Silent nonprinting calculator, pencils
- Provided Scratch sheets and equations
- Results Emailed within 24 hours
- Retake 90 days between attempts
- Attempt cap Three per two-year period
- Recert 20 CEUs every two years
What Each Backflow Stops IR
- Siphon only: AVB, PVB. Both: DCVA, RP
- AVB: no continuous pressure PVB: continuous pressure allowed DCVA: low hazard only RP: high hazard rated
Backsiphonage vs Backpressure IR
Backsiphonage
- Supply pressure turns negative
- Main break or hydrant use
- AVB and PVB protect
Backpressure
- Downstream pressure exceeds supply
- Pump, boiler, or elevation
- Needs DCVA or RP
- Suction vs push back
Backflow Assembly Picker IR
- High hazard or chemigation → RP assembly ( 12 in above grade )
- Backpressure is possible → DCVA or RP ( Vacuum breakers fail here )
- Low hazard, continuous pressure → PVB ( 12 in above heads )
- Low hazard, below grade → DCVA ( Vault with drainage )
- One zone, intermittent pressure → AVB ( 6 in above heads )
- Reclaimed water supply → RP assembly ( Purple pipe required )
- Absolute separation needed → Air gap ( Not a testable assembly )
Sprinklers + Nozzles IR
- Fixed spray head Fine mist, no moving stream
- Spray precipitation rate Roughly 1.5-2.0 in/hr Fast
- Gear-drive rotor Rotating stream, larger radius
- Rotor precipitation rate Roughly 0.4-0.6 in/hr Slow
- Spray nozzle pressure About 30 psi at nozzle
- Rotor nozzle pressure About 45 psi at nozzle
- Head-to-head spacing Throw reaches the next head
- Spacing percentage About 50% of diameter
- MPR nozzle Flow scaled to arc
- Quarter-circle MPR flow About one quarter of full
- Misting at nozzle Pressure is too high
- Dry ring around head Pressure is too low
- Nozzle replacement rule Match brand, arc, radius
- Zone matching rule Never mix sprays and rotors
Blowout Limits IR
- 80 PVC, 50 poly, never through backflow
- 80 psi rigid PVC 50 psi polyethylene Connect downstream of backflow Always wear eye protection
AVB vs PVB IR
AVB
- 6 in above highest outlet
- Downstream of each valve
- No continuous pressure
- Not testable
PVB
- 12 in above highest outlet
- Upstream of all valves
- Continuous pressure allowed
- Testable assembly
- Per zone vs whole system
Sprinkler Symptom Picker IR
- Fine fog at nozzle → Reduce pressure ( Regulator or flow control )
- Short throw, large droplets → Raise pressure ( Check for leaks )
- Dry ring around head → Pressure too low ( Or wrong nozzle )
- Head weeps after shutdown → Add check valve ( Classic low-head drainage )
- Head will not retract → Debris in wiper seal ( Flush the riser )
- Uneven depth across arcs → Install MPR nozzles ( Match flow to arc )
- Runoff before cycle ends → Cycle and soak ( Rate exceeds infiltration )
Swing Joints + Fittings IR
- Swing joint Flexible riser under sprinkler head
- Triple-swing assembly Three street ells linked
- Swing joint purpose Absorbs impact, allows height adjustment
- PVC primer Softens and cleans joint surfaces
- Solvent cement Fuses pipe and fitting
- Cement cure time Wait per label before pressurizing
- Poly pipe joints Barbed insert plus stainless clamp
- Poly and solvent cement Cement will not bond poly
- Threaded joint sealing Tape or dope, no overtightening
- Male adapter rule Plastic male into metal female
Locate Paint Colors IR
- Red power, yellow gas, blue water, purple reclaimed
- Orange: communications Green: sewer White: proposed dig Pink: survey marks
Class vs Schedule Pipe IR
Class pipe
- Number is the psi rating
- Class 200 means 200 psi
- Same rating every diameter
Schedule pipe
- Number describes wall thickness
- Rating falls as diameter grows
- Schedule 40 is common
- Pressure rated vs wall rated
Pipe + Pressure Ratings IR
- Class 200 PVC 200 psi working pressure Pressure rated
- Class 315 PVC 315 psi working pressure
- Schedule 40 Wall thickness, not fixed psi Wall rated
- Schedule rating drift Rating falls as diameter grows
- SDR Diameter divided by wall thickness
- Rating temperature Rated at 73 degrees F
- Polyethylene pipe Flexible, freeze tolerant, barbed fittings
- Purple pipe Reclaimed, non-potable water
- Mainline Constantly pressurized upstream of valves
- Lateral Pressurized only while zone runs
- Sleeve Larger pipe under hardscape
Spray vs Rotor IR
Fixed spray
- About 1.5-2.0 in/hr
- Roughly 30 psi nozzle
- Short radius, sprays continuously
Gear rotor
- About 0.4-0.6 in/hr
- Roughly 45 psi nozzle
- Long radius, rotating stream
- Never mix in one zone
Backflow Functionality IR
- AVB Backsiphonage only, not testable
- AVB height 6 in above highest outlet
- AVB pressure limit No continuous pressure allowed
- AVB position Downstream of the control valve
- PVB Testable, continuous pressure allowed
- PVB height 12 in above highest outlet
- PVB protection Backsiphonage only, not backpressure
- DCVA Two check valves in series Low hazard
- RP assembly Checks plus atmospheric relief valve High hazard
- RP height 12 in above grade
- Air gap Physical separation, strongest protection
- Anti-siphon valve Control valve with built-in AVB
- Chemigation protection RP assembly required
- Assembly testing Usually annual, per local code
Pumps + Water Supplies IR
- Centrifugal pump Above water, needs priming
- Submersible pump Sits in well below water
- Jet pump Shallow well, self-priming
- Cavitation Suction bubbles collapse in impeller
- Cavitation sound Like gravel rattling inside pump
- Pump start relay Controller signal energizes pump
- Dry-run protection Low pressure or float cutoff
- Dead-heading a pump Closed discharge overheats the pump
- Potable supply City main through backflow assembly
- Non-potable supply Well, pond, or reclaimed
- Static water level Well level before pumping
- Drawdown Level drop while pumping
Water Meters + Leaks IR
- Low-flow indicator Small triangle, star, or dial
- Leak test All off, indicator still turns
- Meter sizing Size to peak system flow
- Oversized flow Meter loses excessive pressure
- Mainline leak sign Wet spot, meter creeps constantly
- Lateral leak sign Wet only while zone runs
- Low-head drainage Lowest head weeps after shutdown
- Check valve fix Stops low-head drainage
Job Safety IR
- Call 811 first Mark utilities before any digging
- Locate wait period Legal notice before breaking ground
- Red locate paint Electric power lines
- Yellow locate paint Gas, oil, or steam
- Orange locate paint Communication and signal lines
- Blue locate paint Potable water lines
- Purple locate paint Reclaimed water and irrigation
- Green locate paint Sewer and drain lines
- Trench safety Shore or slope deep trenches
- Confined space entry Test atmosphere, follow permit
- SDS Chemical hazard sheets onsite
- Blowout eye protection Required whenever air is used
Startup + Winterization IR
- Spring startup Fill slowly to purge air
- Fast fill risk Air surge blows nozzles off
- Blowout PVC limit 80 psi maximum air
- Blowout poly limit 50 psi maximum air
- Compressor sizing Zone GPM divided by 7.5
- Blowout connection point Downstream of the backflow assembly
- Air through backflow Destroys internal checks and seats
- Blowout run limit Short bursts, one zone
- Manual drain system Open drain valves at lows
- Backflow winterizing Open test cocks, relieve pressure
- Controller in winter Set off or rain mode
Soil-Plant-Water Basics IR
- Infiltration rate Speed soil absorbs applied water
- Sandy soil Fast intake, low water holding
- Clay soil Slow intake, high water holding
- Runoff cause Precipitation rate exceeds infiltration rate
- Cycle and soak Split run time, add soaks
- Root zone depth Turf shallower than trees
- Field capacity Water held after gravity drainage
- Wilting point Plant can no longer extract
- Available water Between capacity and wilting point
Plans + As-Builts IR
- As-built drawing Record of what was installed
- Legend Key to plan symbols
- Scale Plan distance to real distance
- Engineer scale Reads decimal foot plans
- Specifications Written material and method rules
- Valve location record Measure from two fixed points
- Sleeve record Pipe crossings under hardscape
Ohm's Law EL
- V = I x R at 24 VAC
- Volts = amps x ohms Low ohms means high current 20-60 ohms is healthy
Open vs Short Circuit EL
Open circuit
- Meter reads OL or infinite
- Cut wire or burned coil
- Zone simply will not run
Short circuit
- Meter reads near zero ohms
- Nicked jacket or failed coil
- Controller faults or blows fuse
- No path vs bypass path
Zone Will Not Start EL
- Controller display is dead → Check 120 VAC supply ( Breaker or GFCI )
- No zone runs at all → Test transformer output ( Look for 24 VAC )
- One zone silent, others fine → Test that station output ( Meter set to VAC )
- Station reads 24 VAC → Fault is in field ( Wire, splice, or solenoid )
- Station reads zero volts → Controller output failed ( Move wire to spare )
- Bleed screw opens valve → Electrical fault confirmed ( Valve is mechanically sound )
- Bleed screw does nothing → Hydraulic fault confirmed ( No water or debris )
- Sensor light is active → Bypass the rain sensor ( Common wire interrupted )
Voltmeter Operation EL
- VAC setting Measures field solenoid voltage
- VDC setting Wrong for 24 VAC circuits
- Ohms setting Power off, leads disconnected
- Continuity Beeps on a complete path
- Amps setting Measures current draw inline
- Clamp meter Reads amps without breaking circuit
- OL reading Open circuit, infinite resistance
- Near-zero ohms Short circuit or crossed wires
- Healthy station voltage Roughly 24-28 VAC under load
- Zero volts at station No output from the controller
- Solenoid current draw Well under one amp
Troubleshooting Order EL
- Power, program, controller, wire, solenoid, valve
- Start at the controller Split the run in half Bleed screw separates the fault
Master Valve vs Pump Relay EL
Master valve
- Normally closed solenoid valve
- Isolates mainline when idle
- Limits leak and break damage
Pump start relay
- Switches line power to pump
- Controller cannot drive pumps
- Needs adequate zone flow
- Same terminal, different device
Ohm Reading Picker EL
- Reads 20-60 ohms → Coil is healthy ( Look upstream instead )
- Reads under 20 ohms → Shorted solenoid ( Replace the coil )
- Reads OL or infinite → Open circuit ( Cut wire or coil )
- Good at valve, bad at controller → Field wire or splice ( Track the wire )
- Resistance climbing over time → Corroded splice ( Redo waterproof connector )
- Two zones open together → Two solenoids, one station ( Split to separate terminals )
Controllers + Transformers EL
- Program Start times, run times, days
- Start time meaning Whole program runs once each
- Repeated cycles cause Extra start times were entered
- Station terminal One numbered wire per zone
- Common terminal Shared return for all solenoids
- MV/P terminal Master valve or pump relay
- Transformer job Steps 120 VAC to 24
- Transformer test Read primary and secondary volts
- Seasonal adjust Percent scaling of every runtime
- Rain delay Pauses watering for set days
- Controller reset Clears faults per manufacturer steps
- Smart ET controller Adjusts runtime from weather data
- Manual station test Runs each zone in order
Solenoids + Field Wiring EL
- Solenoid function Plunger vents the diaphragm chamber
- Solenoid voltage 24 VAC standard
- Healthy coil resistance Roughly 20-60 ohms Memorize
- Below 20 ohms Shorted coil, blows fuse
- Infinite ohms Open coil or cut wire
- Manual bleed screw Opens valve without any electricity
- Bleed opens the valve Fault is electrical, not hydraulic
- Wire size rule Longer runs need thicker wire
- Voltage drop Volts lost over wire length
- Common wire color Usually white in the field
- Burial depth 6 in minimum, NEC low voltage
- Under driveways, streets 18 in homes; 24 in streets
- Spare wires Pull extras for future repairs
Wire Tracking + Splices EL
- Wire tracker Transmitter tone plus handheld receiver
- Valve locating Follow the tone to solenoid
- Direct-burial splice Waterproof grease or gel connector
- Wire nut alone Not rated for buried splices
- Failing splice symptom Resistance climbs, valve chatters
- Splice location Inside an accessible valve box
- Surge protection Ground the controller properly
- Lightning damage sign Several zones dead at once
Pressure and Head HY
- psi x 2.31 = feet; feet x 0.433 = psi
- 2.31 feet per psi 0.433 psi per foot 20 feet costs 8.7 psi
Static vs Dynamic Pressure HY
Static
- Measured with no flow
- Highest reading you will see
- Set by supply and elevation
Dynamic
- Measured while zone runs
- Always lower than static
- Falls further as flow rises
- No flow vs flowing
Low Pressure Picker HY
- Static reading is low → Supply side problem ( Meter, city, or well )
- Static fine, dynamic low → Flow related loss ( Friction or too many heads )
- Only far heads suffer → Undersized lateral pipe ( Check the friction chart )
- All zones weak after repair → Partly closed isolation valve ( Open it fully )
- Uphill heads are weak → Elevation loss ( 0.433 psi per foot )
- Pressure fine, flow poor → Clogged filter or nozzle ( Clean and retest )
- Whole system lost pressure → Mainline break ( Meter spins with all off )
Pressure + Flow Testing HY
- Static pressure Measured with no flow
- Dynamic pressure Measured while the zone runs
- Pressure loss Static minus dynamic reading
- psi to feet Multiply psi by 2.31 IA equation
- Feet to psi Multiply feet by 0.433 IA equation
- Elevation gain Costs 0.433 psi per foot
- Elevation drop Gains 0.433 psi per foot
- Flow equation Q = A x V
- Velocity limit Below 5 feet per second
- Water hammer Surge from fast valve closure
- Gauge test point Read at the last head
- Bucket test Time to fill known volume
- Precipitation rate equation PR = 96.3 x GPM / area
Globe vs Angle Valve HY
Globe body
- Inlet and outlet inline
- Drops into straight pipe
- Serviced from the top
Angle body
- Inlet below, outlet at side
- Turns flow ninety degrees
- Used under anti-siphon valves
- Straight run vs corner
Drip Component Picker HY
- Emitters plugging repeatedly → Finer filter ( 120-200 mesh )
- Pressure over emitter rating → Pressure regulator ( Often 25-30 psi )
- Long run or slope → Pressure compensating emitters ( Even flow throughout )
- Fines collect at line end → Flush valve ( Flush every season )
- Soil pulled in at shutdown → Air vacuum relief ( Install at high point )
- Turf area over dripline → Subsurface drip ( Add root protection )
Valves HY
- Globe valve body Inlet and outlet inline
- Angle valve body Inlet below, outlet at side
- Diaphragm operation Pressure above holds valve shut
- Flow control stem Throttles the zone at valve
- Master valve Normally closed, isolates the mainline
- Isolation valve Manual shutoff for repairs
- Quick coupling valve Hose point on the mainline
- Valve box Access, protection, splice housing
- Valve will not close Debris under the diaphragm
- Valve will not open No power or plugged port
- Valve chatter Weak voltage or low flow
- Pressure regulating module Holds a set downstream pressure
Chart vs Hazen-Williams HY
CIT scope
- Read friction loss charts
- Look up size and flow
- Multiply by run length
Designer scope
- Computes the Hazen-Williams equation
- Sizes pipe from scratch
- Tested on CID and CIC
- Look up, do not derive
Sensors HY
- Rain sensor Interrupts the common wire
- Rain sensor test Press plunger, zone should stop
- Freeze sensor Blocks watering below set temperature
- Wind sensor Suspends watering above set speed
- Soil moisture sensor Waters only when soil dries
- Flow sensor Reports actual gallons per minute
- High flow alarm Broken mainline or stuck valve
- Low flow alarm Clogged zone or closed valve
- Sensor bypass switch Ignores the sensor for testing
Drip Mechanics HY
- Required drip components Filter and pressure regulator
- Filter mesh Openings per linear inch
- Typical emitter filtration 120-200 mesh screen
- Higher mesh number Finer screen, smaller particles
- Drip pressure regulator Commonly set 25-30 psi
- Pressure compensating emitter Even flow across pressure range
- Non-compensating emitter Flow rises with pressure
- Maximum lateral length Limited by flow and slope
- Flush valve Purges fines from line ends
- Air vacuum relief Stops soil suction at shutdown
- Subsurface drip Buried dripline with root protection
- Emitter flow units Gallons per hour, not minute
Friction Loss Charts HY
- Chart basis Loss per 100 feet
- Chart inputs Pipe size, material, flow
- Scale to run Multiply by actual pipe length
- Smaller pipe Higher velocity, higher loss
- Larger pipe Lower velocity, lower loss
- C factor Pipe roughness coefficient
- Fitting losses Added as equivalent pipe length
- Chart columns Velocity beside friction loss
Common Traps
Class vs Schedule
- Class 200 means 200 psi ≠ Schedule 40 is wall thickness
Vacuum breaker heights
- AVB sits 6 inches up ≠ PVB sits 12 inches up
Vacuum breakers and backpressure
- AVB and PVB stop backsiphonage ≠ Only DCVA and RP stop backpressure
Chart vs equation
- CIT reads friction charts ≠ Designers compute Hazen-Williams
Volts vs ohms
- Volts tested with power on ≠ Ohms tested with power off
Bleed screw diagnosis
- Bleed opens means electrical fault ≠ Bleed fails means hydraulic fault
Master valve vs relay
- Master valve stops water ≠ Relay switches pump power
Mesh number direction
- 200 mesh is a finer screen ≠ 100 mesh is a coarser screen
Mixing head types
- Spray applies 1.5-2.0 in/hr ≠ Rotor applies 0.4-0.6 in/hr
Pass mark
- Cut score varies by form ≠ It is not a flat 70%
Last Minute
- 1. Principles 41-46%, electrical 28-32%
- 2. Hydraulics is 26-27% of exam
- 3. 100 questions, 3 hours, equal weight
- 4. Pass mark unannounced, typically 68-72%
- 5. 1 psi = 2.31 feet head
- 6. 1 foot head = 0.433 psi
- 7. Keep velocity below 5 ft/s
- 8. Healthy solenoid reads 20-60 ohms
- 9. AVB 6 in, PVB 12 in
- 10. RP is the high-hazard assembly
- 11. Class pipe number is its psi
- 12. Blowout: 80 PVC, 50 poly
- 13. Never blow air through backflow
- 14. Ohms testing requires power off
- 15. Bleed screw isolates electrical faults
- 16. Drip needs filter and regulator
- 17. Higher mesh number is finer
- 18. Call 811 before any digging
- 19. Read charts, do not derive
- 20. Retake wait is 90 days
- 21. Recert: 20 CEUs, two years
IA Certified Irrigation Technician (CIT)
- Practice Questions 126 questions Study Guide 31 topics Cheat Sheet 207 facts Flashcards 50 cards Free CE Podcast
Same family resources
- Explore More Irrigation Association Certifications
- Continue into nearby exams from the same family. Each card keeps practice questions, study guides, flashcards, videos, and articles in one place.
IA Certified Agricultural Irrigation Specialist
- Practice Questions 100 questions Free CE
IA Certified Golf Irrigation Auditor
- Practice Questions 100 questions Free CE
IA Certified Irrigation Contractor
- Practice Questions 100 questions Free CE
IA Certified Irrigation Designer
- Practice Questions 100 questions Free CE
IA Certified Landscape Irrigation Auditor
- Practice Questions 100 questions Free CE
IA Certified Landscape Water Manager
- Practice Questions 100 questions Shorts 1 short Free CE