ICC Journeyman Plumber Cheat Sheet
Administration and General Regulations
- 40% of exam
- Exam Day Logistics Must-Know Definitions Rough-In and Final Tests Materials and Pressure Ratings Supports and Protection Plan Reading and Math 2015 to 2018 Renumbering
Plumbing Fixtures
- 17% of exam
- Fixture Clearances IPC Flow and Flush Limits Water Heater Safety Shower Valve vs Public Lavatory Fixture Clearance Numbers
Water Supply and Distribution
- 14% of exam
- Water Service and Pressure Minimum Fixture Supply Sizes Backflow Device Rules Backflow Device Picker AVB vs RPZ
Sanitary Drainage
- 13% of exam
- DFU Values and Slopes Cleanouts, Sumps, Backwater Which Slope Applies Air Gap or Air Break Which Cleanout Is Required
Plumbing Vent Requirements
- 7% of exam
- Vent Sizing and Terminals Vent Method Picker Trap Arm Ladder Vent Stack vs Stack Vent
Traps, Interceptors, and Separators
- 7% of exam
- Trap Rules Interceptors and Separators Trap Seal Window Prohibited trap types Building trap ban
Storm Drainage
- 2% of exam
- Storm Drainage Rules No sanitary connection Secondary drainage 100-year rainfall basis
Quick Facts
- Exam IDs F25 | G25
- Credential Journeyman Plumber (ICC)
- Questions 70 multiple-choice
- Time F25 3 hours; G25 4 hours
- Code Basis F25 2015 IPC; G25 2018 IPC
- Pass 70%, PASS/FAIL only
- Fee $120
- Format Open book, Pearson VUE
- Retake 10-day wait
- Pass Rate Not published by ICC
Test Numbers AD
- Ten feet, five psi, fifteen minutes
- Water: 10 ft head Air: 5 psi Both: 15 minutes Metal supply air: 50 psi
F25 vs G25 AD
F25
- 2015 IPC
- 3-hour limit
- No grease slope clause
G25
- 2018 IPC
- 4-hour limit
- 1/4 in grease slope
- Same outline, different edition
Exam Day Logistics AD
- F25 2015 IPC, 3 hours
- G25 2018 IPC, 4 hours
- Questions 70 four-option multiple-choice
- Passing score 70 percent, PASS or FAIL
- Retake wait 10 days after a failure
- Guessing penalty None; answer every question
- Calculator Basic non-programmable four-function only
- Allowed marks Ink notes, highlighting, attached tabs
- Prohibited Photocopies of copyrighted material
- Fuel gas Excluded; F28 adds gas
Edition Number Shift AD
- Shower moved up, backwater valve moved down
- 417.4 to 421.4 424.3 to 412.3 715.1 to 714.1
Service vs Distribution Pipe AD
Water Service
- 160 psi at 73.4 F
- PVC permitted
- Buried outside structure
Hot Distribution
- 100 psi at 180 F
- CPVC, never PVC
- Inside the building
- Cold buried vs hot inside
Must-Know Definitions AD
- Branch interval 8 ft stack vertical length
- Developed length Along centerline through fittings
- Building drain ends 30 in past exterior wall
- Stack vent Extension of the waste stack
- Vent stack Air-only vertical vent pipe
- Flood level rim Edge where receptacle overflows
- Critical level C-L mark on backflow device
- No C-L marking Bottom of device governs
- Soil vs waste stack Fecal matter vs liquid waste
Rough-In and Final Tests AD
- DWV water test 10 ft head, 15 min
- Top 10 feet Exempt from the head
- DWV air test 5 psi, 15 minutes
- Air test equivalent 10 in mercury column
- Plastic DWV piping Air test prohibited; water only
- Water supply test Working pressure, 15 minutes
- Air on metal supply 50 psi minimum allowed
- Final smoke test 1 in water column, 15 min
- Shower liner test 2 in water, 15 minutes
- AAV install timing Only after DWV test
Materials and Pressure Ratings AD
- PVC Water service only, never distribution
- CPVC Interior hot and cold distribution
- Water service rating 160 psi at 73.4 F
- Hot distribution rating 100 psi at 180 F
- Lead free pipe 0.25 percent weighted average
- Lead free solder 0.2 percent maximum lead
- PVC primer ASTM F656, purple colored
- Copper types K thickest, L medium, M thin
Supports and Protection AD
- PVC/ABS DWV horizontal 4 ft spacing
- PVC/ABS DWV vertical 10 ft spacing
- Copper 1-1/4 in horizontal 6 ft spacing
- Cast iron horizontal 5 ft, or 10 ft lengths
- Cast iron vertical 15 ft spacing
- Water pipe burial 6 in below frost line
- Burial floor 12 in below grade minimum
- Foundation penetration Sleeve two pipe sizes larger
Plan Reading and Math AD
- 1/4 in scale One inch equals four feet
- 1/8 in scale One inch equals eight feet
- Static head 0.433 psi per vertical foot
- 1 psi 2.31 feet of head
- 45-degree offset Travel equals run times 1.414
- Isometric drawing Shows vertical runs and vents
- Read off isometric DFU, trap arms, vent heights
2015 to 2018 Renumbering AD
- Shower compartment 417.4 becomes 421.4
- Shower opening 417.4.2 becomes 421.4.2
- Shower valve 424.3 becomes 412.3
- Backwater valve 715.1 becomes 714.1
- Chapter 4 order Resequenced alphabetically by fixture
- What changed Numbers moved, rules unchanged
Fixture Clearance Numbers FI
- Fifteen to the wall, thirty apart, twenty-one ahead
- 15 in to wall 30 in center to center 21 in in front
Shower Valve vs Public Lavatory FI
Shower Valve
- 120 F maximum
- ASSE 1016 valve
- Limit stop at valve
Public Lavatory
- 110 F maximum
- ASSE 1070 device
- Tempered water required
- Two limits, two devices
Fixture Clearances FI
- Centerline to wall 15 in minimum
- Centerline to centerline 30 in minimum
- Clear space in front 21 in minimum
- Shower area 900 sq in minimum
- Shower least dimension 30 in minimum
- Shower exception 25 in with 1,300 sq in
- Shower measure height Up to 70 in
- Shower door opening 22 in clear width
- Fixture outlet to weir 24 in vertical maximum
IPC vs WaterSense Flow FI
IPC Table 604.4
- Showerhead 2.5 gpm
- Lavatory 2.2 gpm
- Urinal 1.0 gpf
WaterSense or State
- Showerhead 2.0 gpm
- Lavatory 1.5 gpm
- Urinal 0.5 gpf
- Code base vs amendment
IPC Flow and Flush Limits FI
- Showerhead 2.5 gpm at 80 psi
- Private lavatory faucet 2.2 gpm at 60 psi
- Public lavatory faucet 0.5 gpm at 60 psi
- Metering faucet 0.25 gallon per cycle
- Water closet 1.6 gallons per flush
- Urinal 1.0 gallon per flush
- 2015 vs 2018 Identical flow and flush values
- 2.0, 1.5, 0.5 figures WaterSense or state amendment
Water Heater Safety FI
- T&P discharge size Full size of valve outlet
- Discharge termination 6 in maximum above floor
- Discharge end No threads, no valves
- Discharge routing Gravity, untrapped, one device
- Never connect to The drainage system
- Pan depth 1-1/2 in minimum
- Pan drain 3/4 in indirect waste
- Shower valve limit 120 F, ASSE 1016
- Public lavatory limit 110 F, ASSE 1070
AVB vs RPZ WA
AVB
- 6 in above rim
- No downstream valve
- Not continuous pressure
RPZ
- High hazard rated
- Continuous pressure allowed
- Backpressure and backsiphonage
- Hazard and pressure decide
Backflow Device Picker WA
- High hazard, continuous pressure → RPZ assembly ( ASSE 1013 )
- Low hazard, pollution only → Double check assembly
- Hose bibb or sillcock → Hose connection vacuum breaker ( Permanently attached )
- No downstream valve, intermittent → Atmospheric vacuum breaker ( 6 in above rim )
- Open receptor available → Physical air gap ( Cannot fail mechanically )
- Static pressure over 80 psi → Pressure-reducing valve ( Creates a closed system )
Water Service and Pressure WA
- Minimum service size 3/4 in diameter
- Sewer separation 5 ft compacted earth
- Sleeve alternative 5 ft each side of sewer
- Vertical alternative 12 in above sewer top
- PRV trigger Static pressure over 80 psi
- PRV standard ASSE 1003 with strainer
- 10 ft separation Utility rule, not IPC
RPZ vs Double Check WA
RPZ
- High hazard, contamination
- ASSE 1013 assembly
DCVA
- Low hazard, pollution
- Never on health hazard
- Hazard class picks device
Minimum Fixture Supply Sizes WA
- Lavatory 3/8 in
- Water closet flush tank 3/8 in
- Kitchen sink 1/2 in
- Bathtub 1/2 in
- Shower, single head 1/2 in
- Hose bibb 1/2 in
- Urinal flushometer 3/4 in
- Water closet flushometer 1 in, the outlier
Backflow Device Rules WA
- Air gap size Twice the effective opening
- Air gap minimum 1 in above flood rim
- AVB height 6 in above flood rim
- AVB downstream valve Never permitted
- AVB pressure limit 12 hours in any 24
- RPZ High hazard, continuous pressure
- DCVA Low hazard, pollution only
- Hose bibb Permanently attached vacuum breaker
Slope Ladder SA
- Quarter, eighth, sixteenth as pipe grows
- 2-1/2 in: 1/4 in 3-6 in: 1/8 in 8 in: 1/16 in Grease upstream: 1/4 in, G25
Air Gap vs Air Break SA
Air Gap
- Open space above rim
- Twice the effective opening
- Food equipment requires it
Air Break
- Pipe ends below rim
- Separation to trap seal
- Dishwasher may use it
- Above rim vs below rim
Which Slope Applies SA
- Pipe 2-1/2 in or less → 1/4 in per foot
- Pipe 3 in to 6 in → 1/8 in per foot ( Steeper always allowed )
- Pipe 8 in or larger → 1/16 in per foot
- Upstream of grease interceptor → 1/4 in per foot ( G25 only, 2018 IPC )
- F25, upstream of interceptor → Table 704.1 slopes apply
- Trap arm 2 in or smaller → 1/4 in per foot ( Table 909.1 basis )
- Trap arm 3 or 4 in → 1/8 in per foot ( Table 909.1 basis )
DFU Values and Slopes SA
- Bathroom group 5 dfu, 1.6 gpf closet
- Water closet, private 3 dfu
- Water closet, public 4 dfu
- Lavatory 1 dfu
- Bathtub, shower, kitchen sink 2 dfu each
- Pipe 2-1/2 in or less 1/4 in per foot
- Pipe 3 in to 6 in 1/8 in per foot
- Pipe 8 in or larger 1/16 in per foot
- Upstream of grease trap 1/4 in per foot, G25
Air Gap or Air Break SA
- Food-handling equipment waste → Air gap ( Air break not allowed )
- Potable clear-water waste → Air gap
- Commercial dishwashing machine → Air gap or air break
- Potable water storage tank → Air gap above overflow
- Pipe ends below flood rim → Air break ( Separation to trap seal )
- Sizing the air gap → Twice the effective opening ( No 1-in floor here )
Cleanouts, Sumps, Backwater SA
- Cleanout interval 100 ft, all pipe sizes
- Direction change Cleanout over 45 degrees
- Stack base Cleanout at the foot
- Drain meets sewer Cleanout near that junction
- Clearance, 6 in pipe 18 in in front
- Clearance, 8 in pipe 36 in in front
- Sewage sump pit 18 in wide, 24 deep
- Sump cover Gas-tight, removable, vented
- Discharge valve order Check valve, then full-open
- Ejector solids 2 in spheres with closets
- Backwater valve trigger Floor below upstream manhole cover
- Above that elevation Must bypass the valve
Which Cleanout Is Required SA
- Horizontal run over 100 ft → Cleanout at 100 ft intervals
- Direction change over 45 degrees → Cleanout at the fitting
- Base of a waste stack → Cleanout at stack base
- Building drain meets sewer → Cleanout near that junction
- Pipe 6 in or smaller → 18 in clearance in front
- Pipe 8 in or larger → 36 in clearance in front
- Backwater valve installed → Accessible cleanout for service
Trap Arm Ladder VE
- Bigger trap arm buys a longer run
- 1-1/4 in = 5 ft 1-1/2 in = 6 ft 2 in = 8 ft 3 in = 12 ft 4 in = 16 ft
Vent Stack vs Stack Vent VE
Vent Stack
- Carries air only
- Required at 5 intervals
- Connects at stack base
Stack Vent
- Extends the waste stack
- Above highest drain connection
- Terminates through roof
- Separate pipe vs extension
Vent Method Picker VE
- One fixture trap → Individual vent ( Half the drain served )
- Two traps, one fitting → Common vent
- Bathroom group, one branch → Wet vent
- Battery of 2-8 fixtures → Circuit vent
- Island sink, no wall → Island fixture vent
- No roof penetration possible → Air admittance valve ( One open vent required )
- Stack has 5 branch intervals → Vent stack required
Vent Sizing and Terminals VE
- Individual vent size Half the drain served
- Absolute minimum vent 1-1/4 in
- Vent over 40 ft Increase one nominal size
- Vent stack trigger 5 or more branch intervals
- Trap to vent, 1-1/4 in 5 ft maximum
- Trap to vent, 1-1/2 in 6 ft maximum
- Trap to vent, 2 in 8 ft maximum
- Trap to vent, 3 in 12 ft maximum
- Trap to vent, 4 in 16 ft maximum
- Terminal near opening 10 ft, or 3 ft above
- Promenade roof 7 ft above the roof
- Plain roof height Bracketed; jurisdiction fills in
- Frost closure areas Increase to 3 in diameter
Trap Seal Window TR
- Two to four inches, never deeper
- 2 in minimum 4 in maximum Deeper holds solids Shallower gets siphoned
Trap Rules TR
- Trap seal depth 2 in to 4 in
- Deeper than 4 in Holds solids, not self-scouring
- Prohibited traps S, bell, crown-vented, drum
- Also prohibited Moving-part and partition traps
- Building trap Prohibited, no exception
- Drum trap exception Solids interceptor or chemical waste
- Trap arm fall Not over one pipe diameter
- Fixture outlet to weir 24 in vertical, 30 horizontal
Interceptors and Separators TR
- Grease interceptor Receives FOG-bearing kitchen waste
- Water closet waste Never into grease interceptor
- Upstream slope, G25 1/4 in per foot minimum
- Upstream slope, F25 Table 704.1 slopes govern
- Oil separator Garages and fuel facilities
- Oil separator venting Separate vapor vent required
- Sand interceptor Grit from wash-down areas
- Chemical waste Independent system, neutralize first
Storm Drainage Rules ST
- Storm to sanitary Prohibited under the IPC
- Combined public sewer Connect storm independently, trapped
- Design basis 100-year, one-hour rainfall
- Secondary drainage Required where parapets trap water
- Secondary inlet height 2 in above roof low point
- Subsoil drains Storm system, never sanitary
Common Traps
Flow rates did not change
- IPC showerhead is 2.5 gpm ≠ 2.0 gpm is WaterSense
Urinal flush volume
- IPC urinal is 1.0 gpf ≠ 0.5 gpf is an amendment
Lavatory faucet flow
- Private lavatory is 2.2 gpm ≠ 1.5 gpm is an amendment
Renumbering is not rule change
- 417.4 became 421.4 ≠ Requirements stayed identical
Building traps are banned
- Building trap prohibited outright ≠ Not the same as interceptor
Deeper trap seals are worse
- Over 4 in holds solids ≠ 2 to 4 in only
Water service is not distribution
- PVC for service only ≠ CPVC for interior hot
Sewer separation is 5 feet
- IPC requires 5 ft ≠ 10 ft is a utility rule
Burial needs both numbers
- 6 in below frost line ≠ 12 in below grade
Cleanout clearance is IPC-specific
- IPC uses 18 and 36 in ≠ The 12 in split is UPC
Vent stack vs stack vent
- Vent stack carries air ≠ Stack vent extends waste stack
Bathroom group is discounted
- Group equals 5 dfu ≠ Less than summing parts
Individual vent sizes off drain
- Half the drain served ≠ Not the trap arm
Last Minute
- 1. 70 questions, open book
- 2. F25 3 hours; G25 4 hours
- 3. Pass is 70 percent
- 4. Retake wait is 10 days
- 5. Administration is 40 percent
- 6. Slopes drop: quarter, eighth, sixteenth
- 7. Trap seal 2 to 4 in
- 8. Cleanouts every 100 ft
- 9. Air gap is twice opening
- 10. Showerhead 2.5 gpm, not 2.0
- 11. Water test: 10 ft, 15 min
- 12. No air test on plastic
- 13. Vent stack at 5 intervals
- 14. Storm never enters sanitary sewer
- 15. Building traps are prohibited
- 16. PVC service only; CPVC hot
- 17. Tab Tables 604.4, 704.1, 709.1