Cheat sheet

LEED AP BD+C Cheat Sheet

Practice this exam

Integrative Process

  • 1% of exam
  • Integrative Process Charrette Discovery Energy + Water Analysis

Location + Transportation

  • 15% of exam
  • LEED ND Sensitive Land Transit Access Bicycle Facilities Parking Green Vehicles

Sustainable Sites

  • 9% of exam
  • Site Assessment Open Space Rainwater Heat Island Light Pollution

Water Efficiency

  • 10% of exam
  • Outdoor Water Indoor Water Cooling Tower Process Water Metering

Energy + Atmosphere

  • 30% of exam
  • Commissioning Energy Performance Renewables Refrigerants Grid Harmonization

Materials + Resources

  • 12% of exam
  • Life-Cycle Impact EPD HPD Sourcing Waste Management

Indoor Environmental Quality

  • 15% of exam
  • IAQ Low-Emitting Thermal Comfort Daylight Acoustics Views

Innovation

  • 5% of exam
  • Innovation Credits Pilot Credits Exemplary Performance LEED AP

Regional Priority

  • 4% of exam
  • Regional Priority Location Bonus ZIP-based Credits Up to 4 Points

Quick Facts

  • Exam LEED AP BD+C
  • Provider GBCI / Prometric
  • Questions 100 (85 scored)
  • Time 2 hours
  • Pass 170/200 scaled
  • Fee $250 member combined
  • Prereq LEED Green Associate
  • Validity 2 yr / 30 CE

Credit Categories IP

  • I LSWE MEQ IR maps nine BD+C categories.
  • IP 1 LT 16 SS 10 WE 11 EA 33 MR 13 EQ 16 IN 6 RP 4

Prerequisite vs Credit IP

Prerequisite

  • Mandatory
  • No points awarded
  • Required for certification

Credit

  • Optional
  • Earns points
  • Builds toward level
  • Must do vs choose

IP Credits IP

  • Integrative Process 1 point
  • Discovery phase Pre-design analysis
  • Energy analysis Early load modeling
  • Water analysis Early demand budgeting
  • Charrette Whole-team workshop

Certification Ladder IP

  • C-S-G-P at 40, 50, 60, 80.
  • Certified 40 Silver 50 Gold 60 Platinum 80

Certification Levels IP

  • Certified 40-49 points
  • Silver 50-59 points
  • Gold 60-79 points
  • Platinum 80+ points
  • Total scale 110 points possible
  • Base credits 100 core points

Integrative Flow IP

  • Discover then implement; team agrees early.
  • Discovery Charrette Implementation Iteration

LEED Process IP

  • MPR Minimum program requirements
  • Registration Start certification
  • Scorecard Track credits
  • LEED Online Submit documentation
  • CIR Credit interpretation request
  • Appeal Challenge denial
  • USGBC Develops LEED
  • GBCI Administers certification

BD+C Project Type LT

  • Ground-up office → New Construction ( Default )
  • Developer leases space → Core & Shell ( Pre-tenant )
  • K-12 academic building → Schools ( Acoustics rules )
  • Inpatient hospital → Healthcare ( GGHC overlap )
  • Server-dense facility → Data Centers ( PUE focus )
  • Sales floor space → Retail ( Process loads )
  • Hotel or lodging → Hospitality ( Occupant turnover )
  • Distribution facility → Warehouses ( Logistics fit )

LT Credits (16 pts) LT

  • LEED ND Location Up to 16 points
  • Sensitive Land 1-2 points
  • High Priority Site 1-2 points
  • Surrounding Density 1-5 points
  • Access to Transit 1-5 points
  • Bicycle Facilities 1 point
  • Reduced Parking 1 point
  • Green Vehicles 1 point

BD+C Project Types LT

  • New Construction Default BD+C path
  • Core & Shell Speculative buildings
  • Schools K-12 academic
  • Retail Sales floor space
  • Data Centers Server-dense projects
  • Warehouses Distribution facilities
  • Hospitality Hotels and lodging
  • Healthcare Inpatient facilities

SS Credits (10 pts) SS

  • Construction Pollution Prerequisite Prereq
  • Site Assessment 1 point
  • Site Development 1-2 points
  • Open Space 1 point
  • Rainwater Management 2-3 points
  • Heat Island Reduction 1-2 points
  • Light Pollution 1 point

Graywater vs Rainwater WE

Graywater

  • Used lavatory water
  • Treatment required
  • Indoor reuse

Rainwater

  • Captured precipitation
  • Roof + site
  • Reduces runoff
  • Reuse vs capture

Site Water Strategy WE

  • Cut irrigation demand → Native landscaping ( WE outdoor )
  • Reuse roof runoff → Rainwater capture ( SS rainwater )
  • Lower fixture flow → WaterSense fixtures ( WE indoor )
  • Reduce HVAC water → Cooling tower limits ( WE credit )
  • Track building water → Permanent metering ( WE prereq )
  • Reuse lavatory water → Graywater system ( Treatment needed )

WE Credits (11 pts) WE

  • Outdoor Reduction Prerequisite Prereq
  • Indoor Reduction Prerequisite Prereq
  • Building Metering Prerequisite Prereq
  • Outdoor Reduction credit 1-2 points
  • Indoor Reduction credit 1-6 points
  • Cooling Tower Water 1-2 points
  • Water Metering credit 1 point

Energy Order EA

  • Load, efficiency, renewables, offsets.
  • Reduce load Efficient systems Add renewables Buy offsets

ASHRAE 90.1 vs 62.1 EA

90.1-2016

  • Energy baseline
  • EA prereq
  • Whole-building model

62.1-2016

  • Ventilation rates
  • EQ prereq
  • Outdoor air supply
  • Energy vs ventilation

Energy Strategy EA

  • Reduce load first → Envelope + passive ( IP analysis )
  • Set baseline → ASHRAE 90.1-2016 ( Prereq )
  • Verify systems → Fundamental Cx ( Prereq )
  • Beat baseline more → Enhanced Cx ( EA credit )
  • Submeter end uses → Advanced metering ( 1 point )
  • Add on-site supply → Renewable energy ( Up to 5 )

EA Prerequisites EA

  • Fundamental Cx Required commissioning Prereq
  • Minimum Energy ASHRAE 90.1-2016 Prereq
  • Building Metering Energy submetering Prereq
  • Fundamental Refrigerant No CFCs Prereq

Site EUI vs Source EUI EA

Site EUI

  • Energy at meter
  • Excludes upstream
  • Building boundary

Source EUI

  • Includes generation losses
  • Grid-level view
  • ENERGY STAR uses
  • Meter vs origin

EA Credits (33 pts) EA

  • Enhanced Cx 2-6 points
  • Optimize Energy 1-18 points
  • Advanced Metering 1 point
  • Grid Harmonization 1-2 points
  • Renewable Energy 1-5 points
  • Enhanced Refrigerant 1 point

Whole-Building vs Prescriptive EA

Simulation

  • Energy model
  • Flexible design
  • Higher points possible

Prescriptive

  • ASHRAE compliance path
  • No model needed
  • Lower point ceiling
  • Model vs checklist

Standards Referenced EA

  • ASHRAE 90.1-2016 Energy baseline
  • ASHRAE 62.1-2016 Ventilation rates
  • ASHRAE 55 Thermal comfort
  • ASHRAE 52.2 MERV filtration
  • IES TM-30 Color rendering
  • EPA WaterSense Fixture efficiency
  • Green Seal GS-11 Low-VOC paints
  • SMACNA IAQ Construction IAQ

Fundamental vs Enhanced Cx EA

Fundamental Cx

  • Required prereq
  • Design + construction
  • Verify OPR

Enhanced Cx

  • Optional credit
  • Envelope option
  • 10-month review
  • Required vs optional

Materials Hierarchy MR

  • Reduce, reuse, recycle, then disclose.
  • Reduce first Reuse second Recycle third Disclose impacts

EPD vs HPD MR

EPD

  • Environmental impacts
  • LCA-based
  • Carbon focus

HPD

  • Material ingredients
  • Health disclosure
  • Transparency focus
  • Impact vs ingredients

MR Credits (13 pts) MR

  • Storage of Recyclables Prerequisite Prereq
  • Waste Management Planning Prerequisite Prereq
  • Building Life-Cycle 2-5 points
  • EPD Optimization 1-2 points
  • Sourcing Raw Materials 1-2 points
  • Material Ingredients 1-2 points
  • Construction Waste 1-2 points

EQ Credits (16 pts) EQ

  • Minimum IAQ ASHRAE 62.1-2016 Prereq
  • Tobacco Smoke Control Prerequisite Prereq
  • Enhanced IAQ Strategies 1-2 points
  • Low-Emitting Materials 1-3 points
  • Construction IAQ Plan 1 point
  • IAQ Assessment 1-2 points
  • Thermal Comfort 1 point
  • Interior Lighting 1-2 points
  • Daylight 1-3 points
  • Quality Views 1 point
  • Acoustic Performance 1-2 points

IN + RP Credits IN

  • Innovation 1-5 points
  • LEED AP 1 point
  • Pilot credits Test new strategies
  • Exemplary performance Double credit threshold
  • Regional Priority Up to 4 points
  • RP selection ZIP-based credit list

Common Traps

Total scale

  • 110 max with bonuses ≠ Base scale is 100

Prereq vs credit

  • Prereqs earn zero ≠ Credits earn points

ASHRAE references

  • 90.1 is energy ≠ 62.1 is ventilation

EPD vs HPD

  • EPD = LCA impacts ≠ HPD = ingredients

Combined exam fee

  • $250 member combined ≠ Stand-alone is higher

Score scale

  • 170 of 200 scaled ≠ Not 85% raw

BD+C type fit

  • Core & Shell pre-tenant ≠ NC for ground-up

Last Minute

  • 1. 100 questions; two hours total
  • 2. Pass = 170 of 200 scaled
  • 3. Combined member fee = $250
  • 4. Green Associate prereq required
  • 5. Platinum starts at 80 points
  • 6. ASHRAE 90.1 = energy baseline
  • 7. ASHRAE 62.1 = ventilation baseline
  • 8. EA carries 33 credit points
  • 9. Prereqs mandatory; credits optional
  • 10. EPD impacts; HPD ingredients
  • 11. Reduce load before renewables
  • 12. 30 CE; 6 BD+C-specific

LEED AP Building Design + Construction

  • Practice Questions 200 questions Study Guide 43 topics Cheat Sheet 91 facts Flashcards 50 cards Videos 1 video Blogs 1 blog Free CE Podcast