Master Electrician Cheat Sheet

Practice this exam

General Knowledge

  • 12% of exam
  • Theory Calculations Definitions Plan Reading Exam Rules

Services + Service Equipment

  • 16% of exam
  • Services Fault Current Transformers Grounding Bonding

Feeders

  • 4% of exam
  • Feeders Load Calculations Equipment Grounding Voltage Drop

Branch Circuits + Conductors

  • 16% of exam
  • Branch Circuits OCPD Conductors GFCI/AFCI Outlets

Wiring Methods + Materials

  • 19% of exam
  • Raceways Underground Boxes Panelboards Flexible Cords

Equipment + Devices

  • 10% of exam
  • Luminaires Receptacles Switches Appliances HVAC

Control Devices

  • 3% of exam
  • Switches Disconnects Controllers Within Sight

Motors + Generators

  • 8% of exam
  • Motors Generators FLC Tables Overload SCPD

Special Occupancies + Conditions

  • 12% of exam
  • Pools Hazardous Healthcare Emergency Fire Alarms

Quick Facts

  • Exam R16/T16/G16
  • Questions 100 MCQ
  • Time 5 hours
  • Format Open book
  • Fee $120
  • Pass 75%
  • Pace 3 min/question
  • License Jurisdiction controls

Exam Codes GE

  • R16=2023 | T16=2020 | G16=2017
  • R16: 2023 NEC T16: 2020 NEC G16: 2017 NEC

ICC vs Board GE

ICC

  • Exam delivery
  • Bulletin rules
  • Score report

Board

  • Eligibility
  • License issue
  • Local rules
  • Test vs license

Find NEC Route GE

  • Defined term → Article 100 ( Definitions )
  • General install → Article 110 ( Baseline )
  • Load clue → Article 220 ( Calculations )
  • Service clue → Article 230 ( Source )
  • Grounding clue → Article 250 ( Bonding )
  • Table clue → Chapter 9 ( Notes first )

Exam Logistics GE

  • R16 2023 NEC
  • T16 2020 NEC
  • G16 2017 NEC
  • Items 100 MCQ
  • Limit 5 hours
  • Pass 75%
  • Fee $120
  • Result PASS only

Master Weights GE

  • Wiring leads; services and branches follow
  • Wiring: 19% Services: 16% Branches: 16% Special: 12%

Authority Control GE

  • ICC Exam provider
  • Pearson VUE Test center
  • PRONTO Remote option
  • Board License authority
  • AHJ Interprets code
  • Catalog Current outline
  • Bulletin Rules source
  • Retake 10-day wait

Power Wheel GE

  • E=IR, P=EI, VA=EI
  • Amps: E/R Watts: ExI 3ph: x1.732

Code Map GE

  • 90 Purpose + scope
  • 100 Definitions
  • 110 Install rules
  • 200 Use identification
  • 210 Branch circuits
  • 215 Feeders
  • 220 Load calculations
  • 230 Services
  • 240 Overcurrent
  • 250 Grounding/bonding

Theory Formulas GE

  • Ohm E=IxR
  • Current I=E/R
  • Power P=ExI
  • 1ph VA VxA
  • 3ph VA VxAx1.732
  • PF Watts / VA
  • Series R Add resistances
  • Parallel R Reciprocal sum

Ground/Bond SE

  • Ground stabilizes; bond clears faults
  • Ground: earth Bond: continuity EGC: fault path

Service vs Feeder SE

Service

  • Utility source
  • Before main
  • Article 230

Feeder

  • After service
  • Before branch
  • Article 215
  • Source side matters

Service Sequence SE

  • Calculate load → Article 220
  • Pick service → Article 230
  • Size conductors → 310.16
  • Size GEC → 250.66
  • Bond service → 250.24
  • Check space → 110.26

Service Core SE

  • Article 230 Services
  • Service point Utility boundary
  • Service conductors Before service equipment
  • Disconnect Readily accessible
  • Six rule Max disconnects
  • Fault current Available short-circuit
  • Temporary service Article 590
  • Working space 110.26 route

Grounding vs Bonding SE

Grounding

  • Earth connection
  • Voltage stabilization
  • GEC route

Bonding

  • Metal continuity
  • Fault path
  • MBJ route
  • Earth vs continuity

Grounding + Bonding SE

  • Article 250 Grounding/bonding
  • GEC Electrode conductor
  • EGC Fault path
  • MBJ Service bond
  • SBJ Supply-side bond
  • Ground rod 8 ft electrode
  • Concrete electrode Ufer route
  • Water pipe Bonding route

Load Cues SE

  • Dwelling lighting 3 VA/sq ft
  • Small appliance Two 20A
  • Laundry One 20A
  • Range Table 220.55
  • Dryer 220.54 route
  • Demand factor Table reduction
  • Neutral 220.61 route
  • Continuous Use 125%

Feeder vs Branch BR

Feeder

  • Supplies final OCPD
  • Panel loads
  • 215 route

Branch

  • After final OCPD
  • Outlet loads
  • 210 route
  • Before vs after

Conductor Picker BR

  • Branch circuit → 210.19
  • Feeder circuit → 215.2
  • Motor branch → 430.22
  • Terminal limit → 110.14(C)
  • OCPD limit → 240.4
  • Derating needed → 310.15

Feeders + Branches BR

  • Feeder Before final OCPD
  • Branch After final OCPD
  • 215.2 Feeder ampacity
  • 210.19 Branch conductors
  • 240.4 Conductor protection
  • 310.16 Ampacity table
  • 210.8 GFCI route
  • 210.12 AFCI route

GFCI vs AFCI BR

GFCI

  • Shock protection
  • Ground-fault current
  • Wet locations

AFCI

  • Fire protection
  • Arc faults
  • Dwelling circuits
  • Shock vs fire

Conductor Rules BR

  • 14 Cu 15A max
  • 12 Cu 20A max
  • 10 Cu 30A max
  • Terminations 110.14(C)
  • Correction Ambient heat
  • Adjustment Conductor count
  • Voltage drop Informational note
  • MWBC Common disconnect

Correction vs Adjustment BR

Correction

  • Ambient temperature
  • Heat factor
  • Table correction

Adjustment

  • Conductor count
  • Bundling factor
  • Derating route
  • Temperature vs count

Fill Stack WI

  • Box counts; raceway percent
  • Box: volume Raceway: area Notes: control

Box Fill vs Raceway Fill WI

Box fill

  • Volume allowance
  • Device yokes
  • 314.16

Raceway fill

  • Area percent
  • Chapter 9
  • Table notes
  • Volume vs area

Wiring Picker WI

  • Box fill → 314.16
  • Raceway fill → Chapter 9
  • Underground run → 300.5
  • Wet location → Wet-rated conductors
  • Cord use → Article 400
  • Panelboard issue → Article 408

Wiring Methods WI

  • EMT Article 358
  • RMC Article 344
  • PVC Article 352
  • LFMC Article 350
  • NM Article 334
  • MC Article 330
  • UF Article 340
  • Flexible cord Article 400

Fill + Clearance WI

  • Box fill 314.16
  • Device yoke Two volumes
  • EGCs One total
  • Raceway fill Chapter 9
  • Table 1 40% common
  • Nipple fill 60% max
  • Burial Table 300.5
  • Guarding 110.27 route

Equipment + Devices EQ

  • Luminaires Article 410
  • Switches Article 404
  • Receptacles Article 406
  • Panelboards Article 408
  • Appliances Article 422
  • HVAC Article 440
  • Transformers Article 450
  • Listing Instructions matter

Motor Stack MO

  • FLC, conductors, overload, SCPD
  • FLC: tables Conductor: 125% Overload: nameplate SCPD: faults

OCPD vs Overload MO

OCPD

  • Short circuit
  • Ground fault
  • Conductor protection

Overload

  • Motor heating
  • Running current
  • Nameplate based
  • Fault vs heat

Motor Picker MO

  • Find FLC → 430 tables
  • Size conductor → 430.22
  • Size overload → Nameplate
  • Size SCPD → 430.52
  • Find disconnect → 430.102
  • Generator clue → Article 445

Motors + Generators MO

  • Article 430 Motors
  • Article 445 Generators
  • FLC Use tables
  • Nameplate Overload sizing
  • Conductor 125% FLC
  • SCPD Fault protection
  • Controller Starts motor
  • Disconnect Within sight

Nameplate vs FLC Table MO

Nameplate

  • Overload sizing
  • Actual motor
  • Manufacturer data

FLC table

  • Conductors
  • SCPD sizing
  • NEC standard
  • Task controls source

Emergency vs Standby SP

Emergency

  • Life safety
  • Article 700
  • Legally required

Standby

  • Optional loads
  • Article 702
  • Owner choice
  • Required vs optional

Special Picker SP

  • Pool clue → Article 680
  • Hazardous clue → Article 500
  • Hospital clue → Article 517
  • Emergency power → Article 700
  • PV clue → Article 690
  • Fire alarm → Article 760

Special Systems SP

  • Hazardous Article 500
  • Healthcare Article 517
  • Mobile homes Article 550
  • RV parks Article 551
  • Pools Article 680
  • PV Article 690
  • Emergency Article 700
  • Fire alarms Article 760

Common Traps

Exam vs license

  • ICC tests trade ≠ Board grants license

Open book trap

  • References allowed ≠ Time limited

NEC edition

  • R16 uses 2023 ≠ T16 uses 2020

Service boundary

  • Service before equipment ≠ Feeder after equipment

Ground vs bond

  • Ground earth path ≠ Bond fault path

Continuous load

  • Three hours ≠ Size at 125%

Motor sizing

  • Overload uses nameplate ≠ SCPD uses tables

Fill methods

  • Box uses volume ≠ Raceway uses percent

Protection types

  • GFCI stops shock ≠ AFCI stops arcs

Passing report

  • Pass says PASS ≠ Fail gives diagnostics

Last Minute

  • 1. R16=2023; T16=2020; G16=2017
  • 2. 100 MCQ; 5 hours
  • 3. Passing score: 75%
  • 4. No guessing penalty
  • 5. Wiring Methods weighs 19%
  • 6. Article 100 for definitions
  • 7. Article 220 for loads
  • 8. Article 230 for services
  • 9. Article 250 for grounding
  • 10. Article 430 for motors
  • 11. Chapter 9 for fill
  • 12. GFCI shock; AFCI fire
  • 13. Continuous load: 125%
  • 14. Answer every question

Master Electrician