Cheat sheet
NCCER Millwright Cheat Sheet
Machinery Installation & Alignment
- 20% of exam
- Foundations & Installation Hand Tools & Fasteners Shaft Alignment Alignment Method Picker Rigging & Safety
Precision Measurement
- 15% of exam
- Precision Measuring Tools Trade Math & Blueprints Micrometer vs Dial Indicator Blueprint Reading
Bearings & Lubrication
- 20% of exam
- Bearing Types & Failure Lubrication Bearing & Vibration Diagnosis True vs False Brinelling
Pumps & Mechanical Seals
- 20% of exam
- Pumps Mechanical Seals & Sealing Pump Problem Picker Cavitation vs Gas Binding
Conveyors, Compressors & Turbines
- 25% of exam
- Belt, Chain & Gear Drives Compressors & Turbines Hydraulics & Pneumatics Drive System Picker
Quick Facts
- Exam NCCER Millwright
- Credential NCCER Registry
- Questions 100 multiple-choice
- Time 2 hours
- Pass 70%
- Level Journey-level
- Curriculum 4 levels (2021 ed.)
- Expires Never (Registry)
Alignment Sequence IN
- Level, Soft Foot, Rough, Fine, Dowel
- Level: baseplate flat Soft foot: shim first Rough: jackscrews close Fine: dial/laser final Dowel: lock position
Rim-and-Face vs Reverse-Indicator IN
Rim-and-Face
- One shaft's rim + face
- Needs a solid face
- Axial float risk
Reverse-Indicator
- Both shafts' OD only
- No face reading
- Avoids float error
- Face-dependent vs face-free
Alignment Method Picker IN
- No face reading wanted → Reverse-indicator ( Two brackets )
- Face surface is reliable → Rim-and-face ( Axial float risk )
- Fast rough check only → Straightedge + feeler ( Visual pass )
- Tight final tolerance → Laser alignment ( Digital readout )
- Multiple baseplate elevations → Optical level ( Room reference )
- Machine runs hot → Cold target offset ( Thermal growth )
Hand Tools & Fasteners IN
- Ball peen hammer Strikes chisels, sets rivets
- Box-end wrench Grips all six bolt points
- Tap and die Cut new internal/external threads
- SAE Grade 5 Three radial lines on head
- SAE Grade 8 Six radial lines on head
- Right-hand thread Tightens clockwise
- Wedge anchor Steel clip expands in concrete
- Sleeve anchor Sleeve expands as bolt tightens
- Epoxy anchor Adhesive bonds bolt to concrete
Foundations & Installation IN
- Soft foot Frame twists once bolted down
- Star bolt pattern Even, progressive clamping force
- Jackscrews Fine-tune position before bolt-down
- Dowel pins Lock final aligned position
- Grouting Fills the baseplate void
- Baseplate Fixed machine mounting surface
- Thermal growth Casing expands as it heats
- Woodruff key Self-aligns on tapered shafts
- Gib-head key Angled head drives out easily
Shaft Alignment IN
- Offset misalignment Parallel centerlines, shifted sideways
- Angular misalignment Centerlines meet at an angle
- Reverse-indicator method No face reading needed
- Rim-and-face method Reads rim plus coupling face
- Bar sag Bracket deflection error to subtract
- Cold alignment target Preset offset before startup
- Laser alignment Digital shaft offset readout
- 12-3-6-9 readings Separate vertical from horizontal
- Shim Corrects vertical position only
Rigging & Safety IN
- Personnel-hoist rigging Needs a 5:1 safety factor
- Suspension scaffold rope Needs a 6:1 safety factor
- Sling angle Shallower angle raises leg tension
- Center of gravity Must hang directly under hook
- LOTO Physically isolates every energy source
- Hard hat Type I Top-impact protection only
- Hard hat Type II Top plus lateral protection
- Class G hard hat Protects up to 2,200 volts
- Class E hard hat Protects up to 20,000 volts
- Bench grinder gap Work rest within 1/8 inch
Micrometer vs Dial Indicator ME
Micrometer
- Absolute size
- Thousandths of an inch
- Static dimension
Dial Indicator
- Relative movement
- Runout/alignment use
- Zero-reference change
- Size vs movement
Precision Measuring Tools ME
- Micrometer Reads size to 0.001 in
- Vernier scale Adds 0.0001 in resolution
- Dial indicator Reads relative movement, runout
- Feeler gauge Checks a static gap
- Bore gauge Measures internal bore diameter
- Optical level Sets a room reference plane
- Straightedge Checks baseplate flatness
- Torque wrench Verifies bolt clamping force
- Stroboscope Checks rotating shaft speed
Trade Math & Blueprints ME
- Taper per foot Diameter change over shaft length
- Sheave ratio Speed is inverse of diameter
- Gear reducer ratio Speed down, torque up
- Hidden line Short dashes, edge not visible
- Centerline Marks an axis of symmetry
- Detail drawing One part, full dimensions
- Assembly drawing Shows multiple parts together
- P&ID Piping and instrumentation diagram
Vibration Frequency BE
- 1X Means Unbalance, 2X Means Misalignment
- 1X: rotor weight 2X: coupling misalignment Bearing tone: race defect Broadband: looseness
True vs False Brinelling BE
True Brinelling
- Static overload or impact
- Permanent race dent
- Single event cause
False Brinelling
- Vibration while stationary
- Fretting wear pattern
- No overload event
- Impact vs fretting
Bearing & Vibration Diagnosis BE
- Static overload dent → True brinelling ( Impact damage )
- Marks with no overload → False brinelling ( Shipping fretting )
- Flaking or pitted race → Spalling ( Fatigue failure )
- Peak at 1X RPM → Suspect unbalance ( Rotor weight )
- Peak at 2X RPM → Suspect misalignment ( Coupling stress )
- Install without impact → Induction heater ( Below 250°F )
- Over-filled grease housing → Drop to half full ( Prevent overheat )
Bearing Types & Failure BE
- Anti-friction bearing Uses rolling balls or rollers
- Plain/sleeve bearing Relies on an oil film
- Tapered roller bearing Handles radial plus thrust load
- Thrust bearing Absorbs axial load only
- L10 life 90% survive that rating
- True brinelling Static overload dents the race
- False brinelling Fretting wear while stationary
- Spalling Fatigue flaking of the race
- Heat limit Stay below about 250°F
L10 Bearing Life BE
- L10 Equals 90 Percent Still Surviving
- 10% may fail early Statistical, not guaranteed Higher load shortens L10
Grease vs Oil BE
Grease
- Stays in place
- Low maintenance
- Moderate speed use
Oil
- Better heat removal
- Can filter and circulate
- High-speed, high-temp use
- Simplicity vs cooling
Lubrication BE
- NLGI Grade 2 Most common grease consistency
- ISO VG 68 Oil viscosity centered at 68 cSt
- Grease Low maintenance, stays in place
- Oil Better cooling, high-speed use
- Fill level One-third to one-half full
- Oil analysis Tracks wear-metal trends
- Thermography Finds abnormal heat patterns
Grease Fill Rule BE
- Fill One-Third To One-Half, Never Full
- Full housing overheats Churn needs air space Over-grease is a real risk
NPSH Rule PU
- Keep NPSH Available Above NPSH Required
- NPSHa: system side NPSHr: pump spec Margin avoids cavitation
Centrifugal vs Positive-Displacement Pump PU
Centrifugal
- Flow varies with pressure
- Throttle changes output
- No relief valve needed
Positive Displacement
- Fixed volume per revolution
- Needs a relief valve
- Pressure builds if blocked
- Variable vs fixed flow
Pump Problem Picker PU
- Pitted, noisy impeller → Check NPSHa margin ( Cavitation )
- Lost prime, no pitting → Check for gas binding ( Air ingress )
- Discharge fully closed → Open valve or relief ( Dead-head heat )
- Seal leaking, scored faces → Check the flush plan ( API plan )
- Flow and head both drop → Check wear rings ( Internal recirculation )
Pumps PU
- Centrifugal pump Flow varies with pressure
- Positive-displacement pump Fixed volume per revolution
- NPSH required Pump's own suction spec
- NPSH available System's actual suction margin
- Cavitation Vapor bubbles collapse, pit impeller
- Gas binding Air displaces liquid, loses prime
- Dead-heading Closed discharge overheats fluid
- Wear ring clearance Controls internal fluid recirculation
Cavitation vs Gas Binding PU
Cavitation
- Local pressure drops
- Vapor bubbles collapse
- Pits the impeller
Gas Binding
- Air or gas enters suction
- Displaces liquid at eye
- Loses prime, no pitting
- Vapor collapse vs air displacement
Mechanical Seals & Sealing PU
- Mechanical seal Two lapped faces, near-zero leak
- Packing gland Controlled drip cools packing
- Flush plan Cools and cleans seal faces
- O-ring Static or dynamic elastomer seal
- Spiral wound gasket High-temperature, high-pressure joints
- Cork composite gasket Lower pressure, lower cost joints
Mechanical Seal vs Packing Gland PU
Mechanical Seal
- Two lapped faces
- Near-zero leakage
- Higher cost, precision
Packing Gland
- Compressed packing rings
- Controlled drip cools it
- Simpler, more upkeep
- Sealed vs designed-to-leak
V-Belt vs Timing Belt RO
V-Belt
- Wedges into a groove
- Friction-based grip
- Some slip possible
Timing Belt
- Toothed engagement
- Positive, slip-free drive
- Exact synchronization
- Friction vs positive drive
Drive System Picker RO
- Need slip-free timing → Timing belt ( Toothed drive )
- Need max friction torque → V-belt ( Wedge grip )
- Light duty, low torque → Flat belt ( Surface friction )
- Need positive chain drive → Roller chain ( Check elongation )
- Increase torque, cut speed → Gear reducer ( Same power )
- Incline conveyor loses power → Backstop device ( Blocks runback )
Belt, Chain & Gear Drives RO
- V-belt Wedges into a grooved pulley
- Flat belt Plain surface friction only
- Timing belt Toothed, positive, slip-free drive
- Over-tensioned belt Overloads bearings and shafts
- Under-tensioned belt Slips, glazes, and overheats
- Chain elongation Pin and bushing wear adds up
- Gear reducer Trades speed for more torque
- Backstop Blocks reverse runback on inclines
- Belt tracking Tension, crown, or buildup issue
Compressors & Turbines RO
- Reciprocating compressor Piston compresses gas in pulses
- Rotary screw compressor Continuous meshing-rotor compression
- Intercooling Removes heat between compression stages
- Governor Holds turbine speed under load
- Radial clearance Tight blade-to-casing gap
- Axial thrust Rotor pushed along its axis
- Thrust bearing Absorbs that axial force
Hydraulics & Pneumatics RO
- Pascal's law Pressure transmits equally in fluid
- Force = pressure x area Sizes cylinder output force
- Hydraulic reservoir Stores, cools, settles the fluid
- FRL unit Filters, regulates, lubricates air
- Double-acting cylinder Force in both directions
- Single-acting cylinder Force one way, spring returns
Common Traps
Micrometer vs dial indicator
- Micrometer reads part size ≠ Dial indicator reads movement
True vs false brinelling
- True = impact damage ≠ False = fretting wear
Cavitation vs gas binding
- Cavitation collapses vapor bubbles ≠ Gas binding traps entrained air
NPSHa vs NPSHr
- NPSHa = system's margin ≠ NPSHr = pump's spec
5:1 vs 6:1 rigging factor
- Personnel-hoist rigging needs 5:1 ≠ Suspension scaffold rope needs 6:1
1X vs 2X vibration
- 1X peak signals unbalance ≠ 2X peak signals misalignment
Hard hat Class G vs E
- Class G caps at 2,200V ≠ Class E caps at 20,000V
Last Minute
- 1. Exam: 100 questions, 2 hours, 70%
- 2. Weights: 20-15-20-20-25 by domain
- 3. Micrometer = size; indicator = movement
- 4. Reverse-indicator needs no face reading
- 5. Shims correct vertical position only
- 6. 1X = unbalance; 2X = misalignment
- 7. Heat bearings below 250°F only
- 8. L10 = 90% survive rating
- 9. Grease fills one-third to half
- 10. Keep NPSHa above NPSHr always
- 11. Cavitation = vapor; gas binding = air
- 12. Scaffold rope factor is 6:1
- 13. Personnel-hoist rigging factor is 5:1
- 14. LOTO isolates energy, not just off
NCCER Millwright
- Practice Questions 130 questions Study Guide 35 topics Cheat Sheet 106 facts Flashcards 50 cards Shorts 2 short s Videos 1 video Blogs 1 blog Free CE Podcast