Cheat sheet
NFPA Firefighter I Cheat Sheet
Orientation, ICS + Hazmat
- Not published of exam
- Standards Map 2026 ICS Basics Hazmat + NFPA 704 Pro Board vs IFSAC
Fire Behavior
- Not published of exam
- Fire Development Heat Transfer Hostile Fire Events Flashover vs Backdraft
PPE + SCBA
- Not published of exam
- Turnout Ensemble SCBA Facts NFPA 1970 vs NFPA 1850 Air Management
Fireground Skills
- Not published of exam
- Hose + Handlines Nozzles + Fire Streams Water Supply + Hydrants Ground Ladders Forcible Entry Ventilation Knots + Ropes
Search, Rescue + Survival
- Not published of exam
- Search + Rescue Survival + RIT Building Construction Two-In Two-Out
Quick Facts
- Standard NFPA 1010 Chapter 6
- Edition 2024 edition
- Replaced NFPA 1001 Chapter 4
- Accreditation Pro Board or IFSAC
- Who certifies State or regional entity
- Questions Set by certifying entity
- Pass mark Entity set; 70% common
- Also required Practical skills evaluation
- Hazmat Operations plus product control
- Pro Board deadline June 30, 2026
Pro Board vs IFSAC OR
Pro Board
- Accredits certifying entities
- Over 75 agencies
- Seal aids reciprocity
IFSAC
- Certificate Assembly accredits entities
- Degree Assembly accredits programs
- Also accredits internationally
- Both accredit, neither tests
Standards Map 2026 OR
- NFPA 1010 Firefighter pro qualifications 2024
- Chapter 5 New Support Person level
- Chapter 6 Firefighter I JPRs
- Chapter 7 Firefighter II JPRs
- Replaced 1001 Also 1002, 1003, 1005
- NFPA 470 Hazmat responder competencies
- NFPA 1970 Turnouts, SCBA, PASS design
- NFPA 1850 Gear care and retirement
- NFPA 1930 Hose and ladder testing
- NFPA 1550 Responder health and safety
- NFPA 1580 Medical, fitness, rehab
NFPA 704 vs DOT Placard OR
NFPA 704
- Fixed facilities
- Four colored quadrants
- Ratings 0 to 4
DOT placard
- Transport vehicles
- Hazard class number
- UN identification number
- Building versus vehicle
ICS Basics OR
- Span of control Three to seven 5 ideal
- Unity of command One supervisor each
- Unified command Agencies share one plan
- Type 5 incident Smallest; one operational period
- Type 1 incident Largest, most complex
- IAP Incident action plan
- PAR Personnel accountability report
- Clear text Plain language, no codes
- Accountability tag Tracks who is inside
Hazmat + NFPA 704 OR
- Blue quadrant Health hazard Left
- Red quadrant Flammability Top
- Yellow quadrant Instability or reactivity Right
- White quadrant Special: OX, W-slash Bottom
- Rating scale 0 minimal to 4
- NFPA 704 use Fixed facilities only
- DOT placard Materials in transport
- ERG orange Guide pages
- ERG green Isolation distances
- Firefighter I hazmat Operations with product control
Fire Tetrahedron FI
- Fuel, Heat, Oxygen, Chain reaction
- Triangle: first three Fourth: chain reaction Break any side
Flashover vs Backdraft FI
Flashover
- Heat driven
- Rollover and darkening
- All contents ignite
Backdraft
- Oxygen driven
- Puffing smoke, stained glass
- Explodes on air entry
- Heat versus oxygen
Fire Development FI
- Fire triangle Fuel, heat, oxygen
- Fire tetrahedron Adds chemical chain reaction
- Incipient Ignition, room unaffected
- Growth Plume builds hot layer
- Fully developed All fuels burning
- Decay Fuel or oxygen exhausted
- Ventilation-limited Oxygen starved, fuel remains
- Flashover Transition, not a stage
Heat Transfer FI
- Conduction Through solid contact
- Convection Moving hot gases
- Radiation Across open space
- Direct flame contact Flame touches new fuel
- Exposure fires Radiation drives spread
- Thermal layering Hot gases stay high
Hostile Fire Events FI
- Flashover Heat driven, simultaneous ignition
- Flashover temperature About 1,100 F
- Flashover warning Rollover, driving heat, darkening
- Rollover Flame across ceiling gases
- Backdraft Oxygen driven, smoke explodes
- Backdraft warning Puffing smoke, stained windows
- Backdraft relief Vertical vent above fire
- Smoke explosion Ignites outside fire room
- Gas cooling Short bursts into layer
NFPA 1970 vs NFPA 1850 PP
NFPA 1970
- Product design standard
- Turnouts, SCBA, PASS
- Aimed at manufacturers
NFPA 1850
- Care and maintenance
- Advanced inspection yearly
- Ten-year retirement
- Built versus maintained
Turnout Ensemble PP
- Outer shell Flame and abrasion resistance
- Moisture barrier Blocks water, steam, chemicals
- Thermal liner Most of the insulation
- Particulate hood Blocks fireground carcinogens
- Compression burn Squeezed layers lose insulation
- Helmet Impact and heat protection
- Boots and gloves Puncture and cut protection
- Advanced inspection At least every year
- Retirement Ten years from manufacture
- Rehab Rest, fluids, medical monitoring
SCBA Facts PP
- Open-circuit SCBA Exhaled air vents out
- Positive pressure Facepiece stays pressurized
- EOSTI Low-air alarm activates
- 33% setting NFPA 1981 alarm point
- NFPA 1970 EOSTI Graduated by cylinder rating
- Rule of air management Exit before alarm sounds
- PASS pre-alert About 20 seconds motionless
- PASS full alarm About 30 seconds motionless
- Facial hair Breaks the facepiece seal
- Seal check Every donning, every shift
- UAC Universal air connection
Extinguisher PASS FI
- Pull, Aim, Squeeze, Sweep
- Pull the pin Aim at base Squeeze the handle Sweep side to side
Solid Bore vs Fog FI
Solid bore
- 50 psi handline
- Greater reach and penetration
- Less steam produced
Combination fog
- 100 psi standard
- Adjustable stream pattern
- Better gas cooling
- Reach versus flexibility
Ventilation Picker FI
- No charged line ready → Do not vent ( Wait for attack )
- Contents fire, sound windows → Horizontal vent ( Doors and windows )
- Attic or cockloft fire → Vertical vent ( Directly over fire )
- Backdraft signs present → Vertical vent ( Relieve from above )
- Roof spongy or unsafe → Horizontal only ( No roof crews )
- Large open floor plan → PPV ( Exhaust opening first )
- Light smoke after knockdown → Hydraulic ventilation ( Fog out window )
- Smoke filling stairwell → Vent stairwell top ( Protects egress )
Hose + Handlines FI
- 1.75-inch line Residential attack, 150-180 gpm
- 2.5-inch line Commercial, about 250 gpm
- 1.5-inch line Older, lighter attack line
- 3-inch and larger Supply line duty
- Booster line Small outside fires only
- Attack hose test Minimum 300 psi annually
- Supply hose test Minimum 200 psi annually
- Friction loss Rises with flow squared
- Storz coupling Sexless quarter-turn connection
- Higbee indicator Aligns coupling threads
Conventional Forcing FI
- Gap, Set, Force
- Gap the door Set the tool Force the lock
Horizontal vs Vertical Vent FI
Horizontal
- Doors and windows
- Faster and safer
- Typical contents fires
Vertical
- Cut roof opening
- Directly over fire
- Attic and cockloft
- Existing versus new opening
Attack Line Picker FI
- Single-family residence → 1.75-inch line ( 150-180 gpm )
- Commercial or heavy fire → 2.5-inch line ( About 250 gpm )
- Long interior stretch → 2.5-inch line ( Less friction loss )
- Standpipe operation → 2.5-inch line ( Smooth bore preferred )
- Defensive exterior attack → Master stream ( 80 psi solid bore )
- Protecting an exposure → Second line ( Blocks radiant heat )
- Vehicle fire → 1.75-inch line ( Approach at angle )
- Small trash fire → Booster line ( Exterior Class A )
Nozzles + Fire Streams FI
- Solid bore handline 50 psi nozzle pressure
- Solid bore master 80 psi nozzle pressure
- Combination fog 100 psi standard
- Low-pressure fog 75 or 50 psi
- Straight stream Fog nozzle, narrowed pattern
- Direct attack Water onto burning fuel
- Indirect attack Steam conversion, unoccupied space
- Combination attack O, Z or T
- Nozzle pressure Fixed design value
Hydrant Colors FI
- Blue, Green, Orange, Red descending
- Blue: 1,500+ gpm Green: 1,000-1,499 Orange: 500-999 Red: under 500
Salvage vs Overhaul FI
Salvage
- Protects property
- Covers and chutes
- Starts during fire
Overhaul
- Exposes hidden fire
- Opens walls and ceilings
- After knockdown
- Protect versus expose
Ladder Picker FI
- Second-floor window → 24-foot extension ( Butt about 6 feet )
- Third floor or roof → 35-foot extension
- Working on pitched roof → Roof ladder ( Hooks over ridge )
- Climbing to flat roof → Extension ladder ( Tip 3-5 rungs above )
- Rescue from window → Extension ladder ( Tip below the sill )
- Venting a window → Extension ladder ( Tip at window top )
- Attic or scuttle hatch → Folding ladder ( Narrow spaces )
Water Supply + Hydrants FI
- Class AA Light blue, 1,500+ gpm
- Class A Green, 1,000-1,499 gpm
- Class B Orange, 500-999 gpm
- Class C Red, under 500 gpm
- Hydrant barrel Chrome yellow
- Rating pressure 20 psi residual
- Static source Pond, river, cistern
- Drafting Hard suction from static
- Forward lay Hydrant toward the fire
- Reverse lay Fire back to hydrant
- Color scheme status Recommended, not mandatory
Forcible Entry Picker FI
- Door may be unlocked → Try before you pry
- Inward-swinging wood door → Fork end ( Gap, set, force )
- Outward-swinging metal door → Adz end ( Gap above lock )
- Storefront with cylinder → K-tool ( Through-the-lock )
- Heavy commercial door → Hydraulic spreader ( Rabbit tool )
- Padlock on hasp → Bolt cutters ( Or duckbill lock breaker )
- Speed over damage → Rotary saw ( Most destructive )
Ground Ladders FI
- Climbing angle About 75 degrees
- Butt spacing One quarter working length
- Working length Butt to top support
- Roof access tip Three to five rungs above
- Window rescue tip Even with or below sill
- Ventilation window tip Even with window top
- Fly section Faces away from building
- Leg lock Secures you for work
- Roof ladder Hooks over the ridge
- 24-foot extension Typical second-floor window
- 35-foot extension Third floor or roof
- Folding ladder Attic and scuttle access
Extinguisher Picker FI
- Wood, paper, cloth → Water or ABC ( Class A )
- Gasoline or solvent → Dry chemical or foam ( Class B )
- Energized electrical panel → Carbon dioxide ( Class C )
- Magnesium or sodium → Dry powder agent ( Never water )
- Kitchen fryer fire → Wet chemical ( Class K )
- Mixed occupancy risk → ABC dry chemical ( Broadest coverage )
Forcible Entry FI
- The irons Halligan plus flathead axe
- Fork end Inward-swinging doors
- Adz end Outward-swinging doors
- Pick end Punches locks and glass
- Try before you pry Check unlocked doors first
- Gap, set, force Conventional prying sequence
- K-tool Through-the-lock cylinder pull
- Rabbit tool Hydraulic door spreader
- Bam-bam tool Screws into lock cylinder
- Through-the-lock Least damage method
Ventilation FI
- Tactical ventilation Planned heat, smoke removal
- Horizontal Existing doors and windows
- Vertical Roof opening over fire
- PPV Blower pressurizes the building
- Negative pressure Fan pulls smoke out
- Hydraulic Fog stream out window
- Flow path Inlet to outlet travel
- Exhaust opening Make it before pressurizing
- Coordination rule Charged line in place
- Sounding the roof Tests roof before walking
Portable Extinguishers FI
- Class A Wood, paper, cloth
- Class B Flammable liquids and gases
- Class C Energized electrical equipment
- Class D Combustible metals
- Class K Cooking oils and fats
- Dry chemical Common ABC agent
- Carbon dioxide Class BC, no residue
- Water can Class A only
Knots + Ropes FI
- Life safety rope Supports people; block creel
- Utility rope Tools and cordons only
- Clove hitch Attaches rope to object
- Bowline Fixed loop that holds
- Figure eight on bight Loop anywhere in rope
- Becket bend Joins unequal diameter ropes
- Half hitch Backs up other knots
- Water knot Joins webbing ends
- Working end Part being tied
Salvage + Overhaul FI
- Salvage Protects property from damage
- Overhaul Finds hidden fire extension
- Salvage cover Diverts and catches water
- Water chute Routes water outside
- Overhaul SCBA Keep it on; carcinogens
- Preserve evidence Do not disturb origin
- Thermal imager Finds hidden hot spots
VEIS Search SE
- Vent, Enter, Isolate, Search
- Isolate: close the door Cuts the flow path One room at a time
Primary vs Secondary Search SE
Primary
- During suppression
- Fast systematic sweep
- Life safety first
Secondary
- After fire control
- Slow and thorough
- Different crew preferred
- Speed versus certainty
Search + Rescue SE
- Primary search Fast sweep during suppression
- Secondary search Thorough recheck after control
- Oriented search Officer anchors at door
- Team search Crew stays together
- VEIS Targeted single-room search
- Sweep high too Beds, cribs, tubs, closets
- Behind doors Common victim location
- Stay low Keep wall or hoseline
- Blanket drag Low-profile victim removal
- Two-person seat carry Conscious, non-ambulatory victim
- Extremity carry One arms, one legs
Mayday LUNAR SE
- Location, Unit, Name, Assignment, Resources
- Call it early Then activate PASS Stay on the radio
Type IV vs Type V SE
Type IV
- Heavy timber members
- No concealed spaces
- Massive fuel load
Type V
- Wood frame
- Lightweight trusses, I-joists
- Can fail in minutes
- Mass versus lightweight
Survival + RIT SE
- Two-in, two-out OSHA 1910.134(g)(4)
- Rescue exception Known savable victim inside
- Incipient exception Rule starts beyond incipient
- One outside member May also be IC
- RIT or RIC Dedicated firefighter rescue crew
- RIT kit Spare air with UAC
- Mayday Call it early
- LUNAR Mayday report format
- PASS activation After the Mayday transmission
Building Construction SE
- Type I Fire-resistive; protected steel, concrete
- Type II Noncombustible, unprotected steel
- Type III Ordinary: masonry walls, wood joists
- Type IV Heavy timber, large members
- Type V Wood frame; structure is fuel
- Type I hazard Spalling concrete, long burns
- Type II hazard Steel elongates, roof sags
- Type III hazard Concealed void space spread
- Type V hazard Lightweight trusses fail fast
Common Traps
Flashover vs backdraft
- Flashover is heat driven ≠ Backdraft is oxygen driven
Rollover vs flashover
- Rollover: ceiling gases ignite ≠ Flashover: whole room ignites
Standard vs certificate
- NFPA writes the standard ≠ State entity issues certificate
Chapter 4 vs Chapter 6
- NFPA 1001 used Chapter 4 ≠ NFPA 1010 uses Chapter 6
Alarm vs exit trigger
- Low-air alarm is late ≠ Air management exits sooner
Class C confusion
- Class C means energized ≠ De-energized becomes A or B
Vent timing
- Uncoordinated venting grows fire ≠ Coordinated venting supports attack
Build vs maintain standards
- NFPA 1970 builds gear ≠ NFPA 1850 maintains gear
Unity vs unified command
- Unity: one supervisor each ≠ Unified: agencies share command
Truss vs rafter roof
- Lightweight truss fails fast ≠ Conventional rafters last longer
Salvage vs overhaul
- Salvage protects property ≠ Overhaul exposes hidden fire
Last Minute
- 1. Firefighter I = NFPA 1010 Chapter 6
- 2. NFPA writes it; state entity certifies
- 3. Flashover heat driven; backdraft oxygen driven
- 4. Radiation crosses the street
- 5. Ladder angle about 75 degrees
- 6. Butt out one quarter working length
- 7. Low-air alarm at 33%
- 8. Green hydrant = 1,000-1,499 gpm
- 9. Solid bore 50 psi; fog 100
- 10. Two-in/two-out before interior attack
- 11. Vertical vent goes over fire
- 12. Type V fails fastest
- 13. Primary is fast; secondary thorough
- 14. LUNAR = Location Unit Name Assignment Resources
- 15. Attack hose tested at 300 psi
- 16. Fork end inward; adz outward
- 17. Span of control 3-7
- 18. Isolate the room during VEIS
NFPA 1001 Firefighter I (Pro Board / IFSAC)
- Practice Questions 168 questions Study Guide 27 topics Cheat Sheet 189 facts Flashcards 50 cards 2 Job Wiki Free CE Podcast