Cheat sheet
PRC Radiologic Technologists Licensure Exam Cheat Sheet
Radiologic Physics, Equipment, Biology, Protection
- 20% of exam
- X-Ray Physics & Generators Radiobiology & Dose Limits Quality Assurance & Informatics Radiation Protection
Image Production and Evaluation
- 20% of exam
- Exposure Math & Grids Film, CR, DR & Displays Image Geometry Film Processing
Radiographic Positioning and Radiologic Procedures
- 20% of exam
- Skull, Sinus & Spine Views Chest, Abdomen & Extremities Mammography & Contrast Procedures Trauma Adaptation
Patient Care and Management
- 20% of exam
- R.A. 7431 Law & Jurisprudence Patient Care & Emergencies Anatomy & Terminology Infection Prevention
Radiological Sciences
- 20% of exam
- CT & MRI Physics Ultrasound, Nuclear Med & Therapy Contrast, Renal Labs & Extravasation Pharmacology & Venipuncture
Quick Facts
- Official Exam Items 500 across five 100-item subjects
- Subject Weight 20% each
- 2026 Exam Dates December 10–11
- Session Time 150 minutes per subject
- Total Session Time 12.5 hours; breaks excluded
- Passing Ratings Average ≥75%; each subject ≥60%
- Complete Exam Fee P900
- Removal Exam Fee P450
- Educational Route Recognized BSRT degree
Photoelectric and Compton Interactions PH
Photoelectric
- Incident photon absorbed
- Bound electron ejected
- Strong atomic-number dependence
Compton
- Photon retains part of energy
- Photon changes direction
- Scatter can reduce image contrast
- Absorption differs from partial-energy scattering
X-Ray Physics & Generators PH
- Tungsten Target Atomic number 74; K-binding ≈69.5 keV
- Bremsstrahlung Electron braking; continuous photon spectrum
- Characteristic Emission Shell vacancy filled; discrete photon energy
- Photoelectric Effect Photon absorbed; bound electron ejected
- Compton Scatter Photon redirected; some energy transferred
- Anode Heel Effect Cathode-side intensity generally greater
- HVL Specified absorber halves narrow-beam air kerma
- Added Filtration Harder beam; lower output
- Generator Ripple Lower ripple generally increases output
Tissue Reactions and Stochastic Effects PH
Tissue Reactions
- Endpoint-dependent threshold
- Severity generally rises with dose
- Example: sufficiently severe skin injury
Stochastic Effects
- Probability is the protection concern
- Severity not predicted by dose
- Low-dose risk uses protective models
- Threshold injury differs from probabilistic risk
Radiobiology & Dose Limits PH
- Radiosensitivity Cell type, endpoint and dose matter
- Lymphocytes Apoptosis challenges simple division-rate rule
- Tissue Reactions Threshold depends on endpoint and conditions
- Stochastic Effects Probability modeled; severity not dose-scaled
- Fetal Exposure Assess dose and developmental stage
- PNRI Adult Effective Dose 20mSv/year averaged over five years
- PNRI Adult Lens Dose 20mSv/year averaged over five years
- PNRI Single-Year Maximum 50 mSv effective and lens doses
- PNRI Skin and Extremities 500 mSv/year adult occupational limit
- PNRI Scope Radioactive-material practices; excludes DOH-FDA X-rays
Quality Assurance & Informatics PH
- QA Organized process for reliable imaging
- QC Measurements checking equipment and process performance
- DICOM Image information and communication standard
- PACS Image storage, retrieval and distribution system
- Image Privacy Check pixels and identifying metadata
- Repeat Analysis Identify causes; improve acquisition process
- Dose Indicators Interpret with image quality and context
Exposure Calculation Checks IM
- Units → Assumptions → Formula → Result
- Use consistent distance units Grid factor must be supplied 15% rule is approximate DI describes index versus target
CR and Direct DR Signal Conversion IM
CR
- Storage phosphor latent signal
- Laser readout releases light
- Plate requires appropriate erasure
Direct DR
- Photoconductor creates charge
- Electronic detector readout
- No scintillator light-conversion stage
- Conversion pathway cannot guarantee image superiority
Technique & Grid Picker IM
- Higher kVp proposed → Apply validated technique; assess contrast ( 15% rule is approximate )
- Grid factor explicitly supplied → Multiply original mAs by factor ( Ratio alone does not specify factor )
- Focused-grid peripheral cutoff → Check orientation, centering, level and SID ( Do not merely raise exposure )
- Exposure index differs from target → Assess segmentation, technique and image quality ( Not automatic repeat )
- Film control strip has shifted → Investigate processing against QC baseline ( Do not compensate through patient exposure )
Exposure Math & Grids IM
- Inverse Square I₂ = I₁ × (d₁/d₂)²
- Point-Source Example 160µGy at 1m → 40µGy/2m
- Approximate 15% Rule 80kVp/20mAs → 92kVp/10mAs
- Distance Compensation mAs₂ = mAs₁ × (SID₂/SID₁)²
- SID Example 10mAs/100cm → 32.4mAs/180cm
- Specified Bucky Factor 5 5mAs without grid → 25mAs
- Magnification SID ÷ SOD
- Geometric Unsharpness Focal-spot size × OID/SOD
- Focused Grid Cutoff Check orientation, alignment and focal range
Film, CR, DR & Displays IM
- Film Development Exposed crystals become metallic silver
- Film Fixation Removes remaining unexposed silver halide
- Film QC Compare sensitometry with established baseline
- CR Laser stimulates stored phosphor signal
- Indirect DR Scintillator light → electrical charge
- Direct DR Photoconductor converts X-rays to charge
- Nyquist Frequency 1 ÷ (2 × sampling pitch)
- 100µm Pitch Nyquist 5lp/mm; not measured resolution
- IEC Deviation Index 10 log₁₀(EI/EIₜ)
- DI +3 Exposure index approximately twice target
- Window Width Adjusts displayed intensity range
- Window Level Adjusts displayed range centre
Towne Baseline Relationship PO
- OML thirty; IOML thirty-seven
- Angles relative to named baseline About seven degrees difference Do not force injured neck
Cervical and Lumbar Oblique Targets PO
Cervical
- Intervertebral foramina emphasized
- Rotation changes demonstrated side
- Avoid routine rotation in uncleared trauma
Lumbar
- Zygapophyseal joints emphasized
- Obliquity changes joint demonstration
- Use only when clinically indicated
- Different targets require different positioning logic
Positioning & Trauma Picker PO
- Decubitus fluid demonstration indicated → Place fluid side dependent if safe ( Horizontal beam )
- Decubitus pneumothorax demonstration indicated → Place affected side elevated if safe ( Horizontal beam )
- Free-air study; cannot safely stand → Use prescribed safe decubitus adaptation ( No forced waiting in instability )
- Suspected neck or hip fracture → Preserve precautions; adapt or escalate imaging ( No forced rotation )
- Suspected GI perforation → Radiologist selects appropriate initial water-soluble agent ( Consider aspiration risk )
Skull, Sinus & Spine Views PO
- Towne with OML 30° caudal to OML
- Towne with IOML 37° caudal to IOML
- Caldwell Routine Geometry 15° caudal PA axial projection
- Waters Routine Geometry OML about 37° to detector
- Sinus Fluid Levels Use appropriate horizontal-beam geometry
- Suspected Cervical Injury Preserve precautions; avoid forced movement
- Cervical Obliques Foramina; unsafe routine rotation in trauma
- Lumbar Obliques Zygapophyseal joints; assess clinical indication
Chest, Abdomen & Extremities PO
- PA Chest Less heart magnification than comparable AP
- Decubitus Pleural Fluid Dependent side demonstrates layering fluid
- Decubitus Pneumothorax Elevated affected side demonstrates free gas
- Left Decubitus Abdomen Free gas adjacent to liver
- Grashey Open glenohumeral joint space
- Scapular Y Profile scapula; assess humeral-head relationship
- Gaynor-Hart Tangential carpal canal; avoid forced extension
- Judet Iliac Oblique Posterior column and anterior wall
- Judet Obturator Oblique Anterior column and posterior wall
- Ankle Mortise Approximate 15–20° internal limb rotation
Mammography & Contrast Procedures PO
- CC and MLO Complementary breast tissue demonstration
- Compression Reduce thickness and motion; individualized technique
- US MQSA Phantom Dose ≤3mGy per standard-phantom CC exposure
- Phantom Dose Benchmark Not universal patient-dose ceiling
- Suspected GI Leak Usually begin appropriate water-soluble study
- Aspiration Risk Avoid unsuitable hyperosmolar enteric agents
- Negative Initial Leak Study Radiologist selects further imaging if needed
- Dental Paralleling Principle Receptor parallel to tooth; beam perpendicular
RA 7431 Board Composition PA
- Three technologists; one radiologist; one physicist
- Five members total Chair among three technologists Professional qualifications also required
Radiologic and X-Ray Technology Routes PA
Radiologic Technologist
- Recognized BSRT educational route
- Separate professional registration
- Five-subject enhanced RTLE blueprint
X-Ray Technologist
- Recognized associate-diploma educational route
- Separate professional registration
- Different examination and result cohort
- Keep qualifications and pass rates separate
R.A. 7431 Law & Jurisprudence PA
- RTLE Degree Recognized Bachelor of Radiologic Technology
- Professional Practice Degree alone does not confer registration
- Board Composition Three technologists; radiologist; medical physicist
- Board Minimum Age 30 years at appointment
- Passing Average At least 75% weighted average
- Subject Minimum No subject below 60%
- Conditioned Reexamination Qualifying candidates repeat deficient subjects
- Removal Rating At least 75% each repeated subject
- Privacy Lawful purpose; proportionate information sharing
Vasovagal and Allergic-Like Clues PA
Vasovagal Pattern
- Hypotension with bradycardia may occur
- Pallor and sweating may occur
- Assess overall presentation and evolution
Allergic-Like Pattern
- Airway or skin signs may occur
- Hypotension can be severe
- Heart rate alone cannot exclude
- Emergency assessment overrides a pulse mnemonic
Patient Care & Emergencies PA
- Patient Identity Reconcile identifiers, order, anatomy and side
- Unclear Examination Request Clarify before exposure
- Transfer Safety Assess mobility, precautions, lines and assistance
- Standard Precautions Apply to all patients
- Airborne Precautions Additional controls for pulmonary tuberculosis
- Reaction Assessment Airway, breathing and circulation; summon help
- Adult CPR Rate 100–120 compressions per minute
- Adult CPR Depth At least 5cm; avoid >6cm
- Conventional Adult CPR 30 compressions : 2 breaths
Four Radiotherapy Rs RA
- Repair; Redistribution; Reoxygenation; Repopulation
- Repair of sublethal damage Redistribution through cell cycle Reoxygenation of hypoxic tumor cells Tumor repopulation can oppose control
Conventional Spin-Echo T1 and T2 RA
T1 Weighting
- Relatively short TR and TE
- Longitudinal relaxation contrast
- Simple fluid usually relatively dark
T2 Weighting
- Relatively long TR and TE
- Transverse relaxation contrast
- Simple fluid usually relatively bright
- Sequence modifications can change signal appearance
Contrast & Emergency Picker RA
- Severe symptoms during contrast injection → Stop; summon response; assess ABC ( Follow trained emergency protocol )
- Extravasation suspected → Stop injection; obtain clinical examination ( Assess perfusion, sensation and movement )
- Severe/progressive extravasation symptoms → Obtain urgent surgical assessment ( Do not use volume alone )
- IV contrast; no AKI; eGFR≥30 → ACR: metformin need not stop ( Local policy/label may differ )
- AKI/eGFR<30 or renal-embolic arterial study → Hold metformin; reassess after 48h ( Authorized restart decision )
- Potential penetrating orbital ferromagnetic injury → Radiograph or review suitable prior CT ( Metalworking alone is not indication )
CT & MRI Physics RA
- Helical Pitch Travel/rotation ÷ nominal beam width
- Pitch-Dose Relationship Inverse only with other settings fixed
- Water CT Number Approximately 0 HU
- Air CT Number Approximately −1000 HU
- CTDIvol Standardized phantom-based scanner-output index
- DLP Example 10mGy × 30cm = 300mGy·cm
- Proton Frequency 42.58 MHz/T × field strength
- 1.5T / 3T Protons Approximately 63.87 / 127.74 MHz
- MR Zone III Controlled access under Level-2 MR supervision
- ACR 2026 B₀ Hazard Area Within 9-gauss line; mapped spatially
- Orbital Trauma Concern Evaluate suspected penetrating ferromagnetic foreign body
Modality Physics Picker RA
- GBCA needed; CKD4/5 → Use group II; avoid group I ( Supervising clinician assesses benefit and risk )
- Bolus specified in therapy plan → Verify material, position and planned use ( No independent treatment alteration )
- C-arm geometry can be optimized → Under-table tube; close receptor where feasible ( Use shielding and appropriate exposure settings )
- 5Gy reference air kerma reached → Activate local follow-up process ( Not measured peak skin dose )
- Tc-99m generator eluate prepared → Check radionuclidic and chemical purity ( Use product limits and administration time )
Ultrasound, Nuclear Med & Therapy RA
- Ultrasound Assumed Speed 1540 m/s in soft tissue
- Ultrasound Output ALARA; indication-specific mode and duration
- Tc-99m Photon Approximately 140 keV
- Tc-99m Half-Life Approximately six hours
- TECHNELITE Mo-99 Limit ≤0.15 µCi/mCi Tc-99m at administration
- TECHNELITE Aluminum Limit ≤10 µg/mL before administration
- PET Annihilation Approximately 511keV paired photons
- 20% Window at 140keV 126–154keV: ±10% about centre
- Therapy Fractionation Repair, redistribution, reoxygenation, repopulation
- Tumor Repopulation Can oppose treatment control
- Bolus Use only as specified in plan
- Fluoroscopy Follow-Up Triggers 3Gy skin; 5Gy reference air kerma
Contrast, Renal Labs & Extravasation RA
- Metformin: IV, No AKI, eGFR≥30 ACR: no routine interruption
- Metformin: AKI or eGFR<30 Withhold; 48h; reassess before restarting
- Arterial Renal Embolic Risk ACR metformin withholding also applies
- Gadolinium: CKD4/5 Avoid group I; use group II
- Known or Suspected AKI Group II preferred when GBCA needed
- Extravasation Stop injection; obtain clinical assessment
- Initial Limb Care Elevate; initially apply cold compresses
- Surgical Referral Severe/progressive symptoms; not volume alone
- Routine Extravasation Aspiration Not recommended by ACR
- Contrast Warming Not routinely supported for lower-viscosity agents
Common Traps
Dose Metric
- Reference air kerma ≠ Peak skin absorbed dose
Rating Versus Raw Count
- Official weighted rating ≠ Unvalidated number-correct conversion
Grid Specification
- Grid geometric ratio ≠ Exposure multiplication factor
Detector Versus Patient
- Detector exposure index ≠ Patient organ absorbed dose
Renal Contrast Groups
- Group I gadolinium agents ≠ Group II gadolinium agents
MR Safety Geometry
- Mapped magnetic-field contour ≠ Scanner-room physical wall
Warming Evidence
- Lower-viscosity contrast agents ≠ Higher-viscosity contrast agents
Film and Digital Appearance
- Film optical density ≠ Processed digital display brightness
Last Minute
- 1. 500 items; five equally weighted subjects
- 2. Five sessions ×150min =750min
- 3. Pass average ≥75%; subjects ≥60%
- 4. Board has five specified professionals
- 5. Current PNRI lens: 20mSv five-year average
- 6. PNRI excludes DOH-FDA X-ray sources
- 7. Formula assumptions precede numerical substitution
- 8. Focused grids require correct geometry
- 9. Do not force injured joint movement
- 10. Metformin decision includes AKI and route
- 11. Gadolinium decision includes agent group
- 12. Extravasation referral follows clinical severity
- 13. MR safety includes implants and fields
- 14. Mammography phantom limit is not patient-limit
- 15. Follow-up trigger is not confirmed injury
Philippine Radiologic Technologists Licensure Examination
- Practice Questions 125 questions Study Guide 77 topics Cheat Sheet 124 facts Flashcards 50 cards Games 20 terms Podcast
- Word games 20 terms Guess the Term T E R M S Read the clue and guess the term in 6 tries. Word games 20 terms Term Match Swap tiles to line up three of the same term. Word games 20 terms Term Pairs ? ✓ ✓ ? ? Flip two cards at a time to find matching terms. Word games 20 terms Term Search Q T E R M X Find five hidden terms in a grid of letters.
Same family resources
- Explore More Philippines PRC Health Exams
- Continue into nearby exams from the same family. Each card keeps practice questions, study guides, flashcards, videos, and articles in one place.
Philippine Nurse Licensure Examination
- Cheat Sheet 105 facts Practice Questions 160 questions Study Guide 34 topics Flashcards 50 cards Games 44 terms Shorts 2 short s Videos 1 video Blogs 1 blog
PRC Social Worker Licensure Examination (Philippines)
- Cheat Sheet 221 facts Practice Questions 140 questions Study Guide 82 topics Flashcards 50 cards Shorts 1 short Blogs 1 blog
Nutritionist-Dietitian Licensure Examination
- Cheat Sheet 91 facts Practice Questions 134 questions Study Guide 94 topics Flashcards 50 cards Games 40 terms Shorts 2 short s Blogs 1 blog
Guidance Counselor Licensure Examination (GCLE), Philippines
- Practice Questions 120 questions Study Guide 57 topics
Philippine Medical Technologists Licensure Examination
- Practice Questions 100 questions Study Guide 67 topics Games 20 terms Shorts 1 short
Philippine Physician Licensure Examination
- Practice Questions 100 questions Study Guide 149 topics Shorts 2 short s
More From This Family
- Videos and articles for deeper review.
- Video PNLE TOS 2026: Use the Official PRC Program as Your Study Map Article NDLE Reviewer 2026: PRC Nutritionist-Dietitian Exam Guide 22 min read Article SWLE 2026: Free Social Work Board Exam Guide, Sept 9-11 11 min read Article PNLE TOS 2026: Use the Official PRC Program as Your Study Map 10 min read