Cheat sheet

PRC Radiologic Technologists Licensure Exam Cheat Sheet

Practice this exam

Radiologic Physics, Equipment, Biology, Protection

  • 20% of exam
  • X-Ray Physics & Generators Radiobiology & Dose Limits Quality Assurance & Informatics Radiation Protection

Image Production and Evaluation

  • 20% of exam
  • Exposure Math & Grids Film, CR, DR & Displays Image Geometry Film Processing

Radiographic Positioning and Radiologic Procedures

  • 20% of exam
  • Skull, Sinus & Spine Views Chest, Abdomen & Extremities Mammography & Contrast Procedures Trauma Adaptation

Patient Care and Management

  • 20% of exam
  • R.A. 7431 Law & Jurisprudence Patient Care & Emergencies Anatomy & Terminology Infection Prevention

Radiological Sciences

  • 20% of exam
  • CT & MRI Physics Ultrasound, Nuclear Med & Therapy Contrast, Renal Labs & Extravasation Pharmacology & Venipuncture

Quick Facts

  • Official Exam Items 500 across five 100-item subjects
  • Subject Weight 20% each
  • 2026 Exam Dates December 10–11
  • Session Time 150 minutes per subject
  • Total Session Time 12.5 hours; breaks excluded
  • Passing Ratings Average ≥75%; each subject ≥60%
  • Complete Exam Fee P900
  • Removal Exam Fee P450
  • Educational Route Recognized BSRT degree

Photoelectric and Compton Interactions PH

Photoelectric

  • Incident photon absorbed
  • Bound electron ejected
  • Strong atomic-number dependence

Compton

  • Photon retains part of energy
  • Photon changes direction
  • Scatter can reduce image contrast
  • Absorption differs from partial-energy scattering

X-Ray Physics & Generators PH

  • Tungsten Target Atomic number 74; K-binding ≈69.5 keV
  • Bremsstrahlung Electron braking; continuous photon spectrum
  • Characteristic Emission Shell vacancy filled; discrete photon energy
  • Photoelectric Effect Photon absorbed; bound electron ejected
  • Compton Scatter Photon redirected; some energy transferred
  • Anode Heel Effect Cathode-side intensity generally greater
  • HVL Specified absorber halves narrow-beam air kerma
  • Added Filtration Harder beam; lower output
  • Generator Ripple Lower ripple generally increases output

Tissue Reactions and Stochastic Effects PH

Tissue Reactions

  • Endpoint-dependent threshold
  • Severity generally rises with dose
  • Example: sufficiently severe skin injury

Stochastic Effects

  • Probability is the protection concern
  • Severity not predicted by dose
  • Low-dose risk uses protective models
  • Threshold injury differs from probabilistic risk

Radiobiology & Dose Limits PH

  • Radiosensitivity Cell type, endpoint and dose matter
  • Lymphocytes Apoptosis challenges simple division-rate rule
  • Tissue Reactions Threshold depends on endpoint and conditions
  • Stochastic Effects Probability modeled; severity not dose-scaled
  • Fetal Exposure Assess dose and developmental stage
  • PNRI Adult Effective Dose 20mSv/year averaged over five years
  • PNRI Adult Lens Dose 20mSv/year averaged over five years
  • PNRI Single-Year Maximum 50 mSv effective and lens doses
  • PNRI Skin and Extremities 500 mSv/year adult occupational limit
  • PNRI Scope Radioactive-material practices; excludes DOH-FDA X-rays

Quality Assurance & Informatics PH

  • QA Organized process for reliable imaging
  • QC Measurements checking equipment and process performance
  • DICOM Image information and communication standard
  • PACS Image storage, retrieval and distribution system
  • Image Privacy Check pixels and identifying metadata
  • Repeat Analysis Identify causes; improve acquisition process
  • Dose Indicators Interpret with image quality and context

Exposure Calculation Checks IM

  • Units → Assumptions → Formula → Result
  • Use consistent distance units Grid factor must be supplied 15% rule is approximate DI describes index versus target

CR and Direct DR Signal Conversion IM

CR

  • Storage phosphor latent signal
  • Laser readout releases light
  • Plate requires appropriate erasure

Direct DR

  • Photoconductor creates charge
  • Electronic detector readout
  • No scintillator light-conversion stage
  • Conversion pathway cannot guarantee image superiority

Technique & Grid Picker IM

  • Higher kVp proposed → Apply validated technique; assess contrast ( 15% rule is approximate )
  • Grid factor explicitly supplied → Multiply original mAs by factor ( Ratio alone does not specify factor )
  • Focused-grid peripheral cutoff → Check orientation, centering, level and SID ( Do not merely raise exposure )
  • Exposure index differs from target → Assess segmentation, technique and image quality ( Not automatic repeat )
  • Film control strip has shifted → Investigate processing against QC baseline ( Do not compensate through patient exposure )

Exposure Math & Grids IM

  • Inverse Square I₂ = I₁ × (d₁/d₂)²
  • Point-Source Example 160µGy at 1m → 40µGy/2m
  • Approximate 15% Rule 80kVp/20mAs → 92kVp/10mAs
  • Distance Compensation mAs₂ = mAs₁ × (SID₂/SID₁)²
  • SID Example 10mAs/100cm → 32.4mAs/180cm
  • Specified Bucky Factor 5 5mAs without grid → 25mAs
  • Magnification SID ÷ SOD
  • Geometric Unsharpness Focal-spot size × OID/SOD
  • Focused Grid Cutoff Check orientation, alignment and focal range

Film, CR, DR & Displays IM

  • Film Development Exposed crystals become metallic silver
  • Film Fixation Removes remaining unexposed silver halide
  • Film QC Compare sensitometry with established baseline
  • CR Laser stimulates stored phosphor signal
  • Indirect DR Scintillator light → electrical charge
  • Direct DR Photoconductor converts X-rays to charge
  • Nyquist Frequency 1 ÷ (2 × sampling pitch)
  • 100µm Pitch Nyquist 5lp/mm; not measured resolution
  • IEC Deviation Index 10 log₁₀(EI/EIₜ)
  • DI +3 Exposure index approximately twice target
  • Window Width Adjusts displayed intensity range
  • Window Level Adjusts displayed range centre

Towne Baseline Relationship PO

  • OML thirty; IOML thirty-seven
  • Angles relative to named baseline About seven degrees difference Do not force injured neck

Cervical and Lumbar Oblique Targets PO

Cervical

  • Intervertebral foramina emphasized
  • Rotation changes demonstrated side
  • Avoid routine rotation in uncleared trauma

Lumbar

  • Zygapophyseal joints emphasized
  • Obliquity changes joint demonstration
  • Use only when clinically indicated
  • Different targets require different positioning logic

Positioning & Trauma Picker PO

  • Decubitus fluid demonstration indicated → Place fluid side dependent if safe ( Horizontal beam )
  • Decubitus pneumothorax demonstration indicated → Place affected side elevated if safe ( Horizontal beam )
  • Free-air study; cannot safely stand → Use prescribed safe decubitus adaptation ( No forced waiting in instability )
  • Suspected neck or hip fracture → Preserve precautions; adapt or escalate imaging ( No forced rotation )
  • Suspected GI perforation → Radiologist selects appropriate initial water-soluble agent ( Consider aspiration risk )

Skull, Sinus & Spine Views PO

  • Towne with OML 30° caudal to OML
  • Towne with IOML 37° caudal to IOML
  • Caldwell Routine Geometry 15° caudal PA axial projection
  • Waters Routine Geometry OML about 37° to detector
  • Sinus Fluid Levels Use appropriate horizontal-beam geometry
  • Suspected Cervical Injury Preserve precautions; avoid forced movement
  • Cervical Obliques Foramina; unsafe routine rotation in trauma
  • Lumbar Obliques Zygapophyseal joints; assess clinical indication

Chest, Abdomen & Extremities PO

  • PA Chest Less heart magnification than comparable AP
  • Decubitus Pleural Fluid Dependent side demonstrates layering fluid
  • Decubitus Pneumothorax Elevated affected side demonstrates free gas
  • Left Decubitus Abdomen Free gas adjacent to liver
  • Grashey Open glenohumeral joint space
  • Scapular Y Profile scapula; assess humeral-head relationship
  • Gaynor-Hart Tangential carpal canal; avoid forced extension
  • Judet Iliac Oblique Posterior column and anterior wall
  • Judet Obturator Oblique Anterior column and posterior wall
  • Ankle Mortise Approximate 15–20° internal limb rotation

Mammography & Contrast Procedures PO

  • CC and MLO Complementary breast tissue demonstration
  • Compression Reduce thickness and motion; individualized technique
  • US MQSA Phantom Dose ≤3mGy per standard-phantom CC exposure
  • Phantom Dose Benchmark Not universal patient-dose ceiling
  • Suspected GI Leak Usually begin appropriate water-soluble study
  • Aspiration Risk Avoid unsuitable hyperosmolar enteric agents
  • Negative Initial Leak Study Radiologist selects further imaging if needed
  • Dental Paralleling Principle Receptor parallel to tooth; beam perpendicular

RA 7431 Board Composition PA

  • Three technologists; one radiologist; one physicist
  • Five members total Chair among three technologists Professional qualifications also required

Radiologic and X-Ray Technology Routes PA

Radiologic Technologist

  • Recognized BSRT educational route
  • Separate professional registration
  • Five-subject enhanced RTLE blueprint

X-Ray Technologist

  • Recognized associate-diploma educational route
  • Separate professional registration
  • Different examination and result cohort
  • Keep qualifications and pass rates separate

R.A. 7431 Law & Jurisprudence PA

  • RTLE Degree Recognized Bachelor of Radiologic Technology
  • Professional Practice Degree alone does not confer registration
  • Board Composition Three technologists; radiologist; medical physicist
  • Board Minimum Age 30 years at appointment
  • Passing Average At least 75% weighted average
  • Subject Minimum No subject below 60%
  • Conditioned Reexamination Qualifying candidates repeat deficient subjects
  • Removal Rating At least 75% each repeated subject
  • Privacy Lawful purpose; proportionate information sharing

Vasovagal and Allergic-Like Clues PA

Vasovagal Pattern

  • Hypotension with bradycardia may occur
  • Pallor and sweating may occur
  • Assess overall presentation and evolution

Allergic-Like Pattern

  • Airway or skin signs may occur
  • Hypotension can be severe
  • Heart rate alone cannot exclude
  • Emergency assessment overrides a pulse mnemonic

Patient Care & Emergencies PA

  • Patient Identity Reconcile identifiers, order, anatomy and side
  • Unclear Examination Request Clarify before exposure
  • Transfer Safety Assess mobility, precautions, lines and assistance
  • Standard Precautions Apply to all patients
  • Airborne Precautions Additional controls for pulmonary tuberculosis
  • Reaction Assessment Airway, breathing and circulation; summon help
  • Adult CPR Rate 100–120 compressions per minute
  • Adult CPR Depth At least 5cm; avoid >6cm
  • Conventional Adult CPR 30 compressions : 2 breaths

Four Radiotherapy Rs RA

  • Repair; Redistribution; Reoxygenation; Repopulation
  • Repair of sublethal damage Redistribution through cell cycle Reoxygenation of hypoxic tumor cells Tumor repopulation can oppose control

Conventional Spin-Echo T1 and T2 RA

T1 Weighting

  • Relatively short TR and TE
  • Longitudinal relaxation contrast
  • Simple fluid usually relatively dark

T2 Weighting

  • Relatively long TR and TE
  • Transverse relaxation contrast
  • Simple fluid usually relatively bright
  • Sequence modifications can change signal appearance

Contrast & Emergency Picker RA

  • Severe symptoms during contrast injection → Stop; summon response; assess ABC ( Follow trained emergency protocol )
  • Extravasation suspected → Stop injection; obtain clinical examination ( Assess perfusion, sensation and movement )
  • Severe/progressive extravasation symptoms → Obtain urgent surgical assessment ( Do not use volume alone )
  • IV contrast; no AKI; eGFR≥30 → ACR: metformin need not stop ( Local policy/label may differ )
  • AKI/eGFR<30 or renal-embolic arterial study → Hold metformin; reassess after 48h ( Authorized restart decision )
  • Potential penetrating orbital ferromagnetic injury → Radiograph or review suitable prior CT ( Metalworking alone is not indication )

CT & MRI Physics RA

  • Helical Pitch Travel/rotation ÷ nominal beam width
  • Pitch-Dose Relationship Inverse only with other settings fixed
  • Water CT Number Approximately 0 HU
  • Air CT Number Approximately −1000 HU
  • CTDIvol Standardized phantom-based scanner-output index
  • DLP Example 10mGy × 30cm = 300mGy·cm
  • Proton Frequency 42.58 MHz/T × field strength
  • 1.5T / 3T Protons Approximately 63.87 / 127.74 MHz
  • MR Zone III Controlled access under Level-2 MR supervision
  • ACR 2026 B₀ Hazard Area Within 9-gauss line; mapped spatially
  • Orbital Trauma Concern Evaluate suspected penetrating ferromagnetic foreign body

Modality Physics Picker RA

  • GBCA needed; CKD4/5 → Use group II; avoid group I ( Supervising clinician assesses benefit and risk )
  • Bolus specified in therapy plan → Verify material, position and planned use ( No independent treatment alteration )
  • C-arm geometry can be optimized → Under-table tube; close receptor where feasible ( Use shielding and appropriate exposure settings )
  • 5Gy reference air kerma reached → Activate local follow-up process ( Not measured peak skin dose )
  • Tc-99m generator eluate prepared → Check radionuclidic and chemical purity ( Use product limits and administration time )

Ultrasound, Nuclear Med & Therapy RA

  • Ultrasound Assumed Speed 1540 m/s in soft tissue
  • Ultrasound Output ALARA; indication-specific mode and duration
  • Tc-99m Photon Approximately 140 keV
  • Tc-99m Half-Life Approximately six hours
  • TECHNELITE Mo-99 Limit ≤0.15 µCi/mCi Tc-99m at administration
  • TECHNELITE Aluminum Limit ≤10 µg/mL before administration
  • PET Annihilation Approximately 511keV paired photons
  • 20% Window at 140keV 126–154keV: ±10% about centre
  • Therapy Fractionation Repair, redistribution, reoxygenation, repopulation
  • Tumor Repopulation Can oppose treatment control
  • Bolus Use only as specified in plan
  • Fluoroscopy Follow-Up Triggers 3Gy skin; 5Gy reference air kerma

Contrast, Renal Labs & Extravasation RA

  • Metformin: IV, No AKI, eGFR≥30 ACR: no routine interruption
  • Metformin: AKI or eGFR<30 Withhold; 48h; reassess before restarting
  • Arterial Renal Embolic Risk ACR metformin withholding also applies
  • Gadolinium: CKD4/5 Avoid group I; use group II
  • Known or Suspected AKI Group II preferred when GBCA needed
  • Extravasation Stop injection; obtain clinical assessment
  • Initial Limb Care Elevate; initially apply cold compresses
  • Surgical Referral Severe/progressive symptoms; not volume alone
  • Routine Extravasation Aspiration Not recommended by ACR
  • Contrast Warming Not routinely supported for lower-viscosity agents

Common Traps

Dose Metric

  • Reference air kerma ≠ Peak skin absorbed dose

Rating Versus Raw Count

  • Official weighted rating ≠ Unvalidated number-correct conversion

Grid Specification

  • Grid geometric ratio ≠ Exposure multiplication factor

Detector Versus Patient

  • Detector exposure index ≠ Patient organ absorbed dose

Renal Contrast Groups

  • Group I gadolinium agents ≠ Group II gadolinium agents

MR Safety Geometry

  • Mapped magnetic-field contour ≠ Scanner-room physical wall

Warming Evidence

  • Lower-viscosity contrast agents ≠ Higher-viscosity contrast agents

Film and Digital Appearance

  • Film optical density ≠ Processed digital display brightness

Last Minute

  • 1. 500 items; five equally weighted subjects
  • 2. Five sessions ×150min =750min
  • 3. Pass average ≥75%; subjects ≥60%
  • 4. Board has five specified professionals
  • 5. Current PNRI lens: 20mSv five-year average
  • 6. PNRI excludes DOH-FDA X-ray sources
  • 7. Formula assumptions precede numerical substitution
  • 8. Focused grids require correct geometry
  • 9. Do not force injured joint movement
  • 10. Metformin decision includes AKI and route
  • 11. Gadolinium decision includes agent group
  • 12. Extravasation referral follows clinical severity
  • 13. MR safety includes implants and fields
  • 14. Mammography phantom limit is not patient-limit
  • 15. Follow-up trigger is not confirmed injury

Philippine Radiologic Technologists Licensure Examination

  • Practice Questions 125 questions Study Guide 77 topics Cheat Sheet 124 facts Flashcards 50 cards Games 20 terms Podcast
  • Word games 20 terms Guess the Term T E R M S Read the clue and guess the term in 6 tries. Word games 20 terms Term Match Swap tiles to line up three of the same term. Word games 20 terms Term Pairs ? ✓ ✓ ? ? Flip two cards at a time to find matching terms. Word games 20 terms Term Search Q T E R M X Find five hidden terms in a grid of letters.

Same family resources

  • Explore More Philippines PRC Health Exams
  • Continue into nearby exams from the same family. Each card keeps practice questions, study guides, flashcards, videos, and articles in one place.

Philippine Nurse Licensure Examination

  • Cheat Sheet 105 facts Practice Questions 160 questions Study Guide 34 topics Flashcards 50 cards Games 44 terms Shorts 2 short s Videos 1 video Blogs 1 blog

PRC Social Worker Licensure Examination (Philippines)

  • Cheat Sheet 221 facts Practice Questions 140 questions Study Guide 82 topics Flashcards 50 cards Shorts 1 short Blogs 1 blog

Nutritionist-Dietitian Licensure Examination

  • Cheat Sheet 91 facts Practice Questions 134 questions Study Guide 94 topics Flashcards 50 cards Games 40 terms Shorts 2 short s Blogs 1 blog

Guidance Counselor Licensure Examination (GCLE), Philippines

  • Practice Questions 120 questions Study Guide 57 topics

Philippine Medical Technologists Licensure Examination

  • Practice Questions 100 questions Study Guide 67 topics Games 20 terms Shorts 1 short

Philippine Physician Licensure Examination

  • Practice Questions 100 questions Study Guide 149 topics Shorts 2 short s

More From This Family

  • Videos and articles for deeper review.
  • Video PNLE TOS 2026: Use the Official PRC Program as Your Study Map Article NDLE Reviewer 2026: PRC Nutritionist-Dietitian Exam Guide 22 min read Article SWLE 2026: Free Social Work Board Exam Guide, Sept 9-11 11 min read Article PNLE TOS 2026: Use the Official PRC Program as Your Study Map 10 min read