ACS CCN1 Core Domestic Gas Cheat Sheet
Cheat sheet ACS CCN1 Core Domestic Gas Cheat Sheet Practice Questions Study Guide Print / Save PDF
Legislation & Duties Not published of exam GSIUR 1998 Gas Safe Landlord CP12 ECV RIDDOR
Tightness, Let-By & Purge Not published of exam Let-By & Tightness Purging & Pipework Permissible Drops Bonding
Gas Rate & Pressure Not published of exam Gas Rate & Heat Input Natural Gas Properties Calorific Value Working Pressure
Ventilation & Flueing Not published of exam Ventilation (BS 5440-2) Flue Types Flue Flow & Spillage Terminal Siting
Combustion & CO/CO2 Not published of exam Combustion Analysis CO Hazard & Alarms CO/CO2 Ratio Flame Picture
Unsafe Situations (GIUSP) Not published of exam GIUSP Classifications Emergency Actions ID vs AR 0800 111 999
Quick Facts Exam ACS CCN1 Credential Gas Safe core domestic Format Open book + practical Pass Each subject; ~80% theory Reassess Every 5 years Test pressure 20-21 mbar CO/CO2 limit ≤ 0.004 Standards GSIUR, IGEM, BS 5440
Legislation & Duties LE GSIUR 1998 Primary gas safety law Gas Safe Register Legal registration body CORGI ended Gas Safe from 2009 Regulation 3 Operative must be registered Regulation 36 Landlord annual check CP12 Landlord Gas Safety Record ECV Emergency control valve Operative duty Leave installation safe
Commissioning Order TE Check, Test, Purge, Light, Analyse Visual check Tightness test Purge Light + rate Flue / spillage
Let-By vs Tightness TE
Let-by Tests ECV seal 7-10 mbar No rise 1 min
Tightness Tests whole system 20-21 mbar 2-minute drop Valve vs system
Tightness Test Decision TE Before tightness test → Let-by test ( 7-10 mbar ) ECV lets by → Stop ( Do not test ) Existing, ≤28mm pipe → Allow 4 mbar ( U6/G4, appliances ) Existing, >28mm pipe → Allow 2.5 mbar ( With appliances ) New pipework only → No drop ( Any drop fails ) Pressure drop seen → Trace leak ( Rectify, retest ) Test satisfactory → Purge ( Then commission )
Let-By & Tightness Test TE Let-by test Check ECV seals First Let-by pressure 7-10 mbar applied Let-by pass No rise 1 minute Test pressure 20-21 mbar working Stabilisation 1 minute settle Timed test 2 minutes Drop ≤28mm 4 mbar max (U6/G4) Drop >28mm 2.5 mbar max New pipework only No drop permitted IGEM/UP/1B Tightness test standard
Purging & Pipework TE Purging Remove air from pipe Purge point Vent to safe place Max pipe drop 1 mbar meter to appliance Pipe sleeving Protect through walls Sleeve seal One end only Bonding Within 600mm meter outlet Bonding standard BS 7671 equipotential
Gas Rate Formula GA Volume × 3600 ÷ time = rate Then × CV CV ≈ 10.76 kWh/m³ Gives kW input
Standing vs Working GA
Standing Appliance off No flow Static pressure
Working Appliance firing Full rate Dynamic pressure Off vs running
Gas Rate & Heat Input GA Gas rate Volume × 3600 ÷ time Units m³ per hour Gross CV ≈ 39.5 MJ/m³ CV multiplier ≈ 10.76 kWh/m³ Heat input Gas rate × CV kW formula m³/h × CV ÷ 3.6 Compare with Appliance data plate Working pressure 21 mbar nominal
Natural Gas vs LPG GA
Natural gas Methane RD ≈ 0.6 Rises when leaking
LPG Propane/butane RD > 1 Sinks when leaking Lighter vs heavier
Natural Gas Properties GA Main constituent Methane (CH₄) Relative density ≈ 0.6, lighter than air Escape behaviour Rises, collects high Flammability limits 5% to 15% gas Standing pressure No flow, appliance off Meter outlet band 18.5-23 mbar (IGEM/G/13)
Flue Types A-B-C VE A=none, B=open, C=sealed A: flueless cooker B: open-flued C: room-sealed
Open-flued vs Room-sealed VE
Open-flued (B) Room combustion air Needs ventilation Spillage test
Room-sealed (C) Outside combustion air No room vent No spillage test Room air vs sealed
Flue & Spillage Check VE Open-flued appliance → Flue flow test ( Smoke first ) Flue proven clear → Spillage test ( At diverter ) Extract fan fitted → Run it ( Worst case ) Smoke spills ~5 min → Fail ( Classify unsafe ) Room-sealed appliance → No spillage test ( Sealed circuit ) Terminal near opening → Check clearances ( BS 5440-1 )
Ventilation (BS 5440-2) VE BS 5440-2 Ventilation standard ≤70kW Open-flue vent 5 cm²/kW above 7kW First 7kW Covered by adventitious air Net input basis Ventilation uses net kW Room-sealed No purpose vent needed Flueless vent Room volume + openable window Compartment High and low vents
Flue Types VE Type A Flueless (e.g. cooker) Type B Open-flued, room air Type C Room-sealed, balanced Draught diverter Open-flue spillage point Balanced flue Air in, products out Fanned flue Fan-assisted room-sealed
Flue Flow & Spillage VE Flue flow test Smoke confirms flue clear Test order Flow before spillage Spillage test Products not entering room Worst case Doors and windows closed Extract fans Run during test Spillage check Smoke match ~5 minutes Terminal siting BS 5440-1 clearances
Complete vs Incomplete CO
Complete CO₂ + water Blue flame Ratio ≤ 0.004
Incomplete Produces CO Yellow/sooty flame Ratio > 0.004 Safe vs dangerous burn
Combustion Analysis CO Complete combustion CO₂ + water vapour Incomplete combustion Produces carbon monoxide CO/CO₂ pass ≤ 0.004 ratio Investigate band 0.004 to 0.008 Sampling point Products at full rate High CO, low CO₂ Incomplete combustion sign Good flame Crisp blue picture Standard BS 7967 / BS 5440
CO Hazard & Alarms CO Carbon monoxide Colourless, odourless, toxic CO effect Binds haemoglobin, starves oxygen Common cause Blocked flue, poor air CO alarm BS EN 50291 audible ASD / ODS Shuts off on vitiation Symptoms Headache, dizziness, nausea
GIUSP Levels UN ID worst, AR next, NCS least ID: immediate danger AR: could become NCS: old standard
ID vs AR UN
Immediately Dangerous Immediate danger Turn off + label Disconnect (permission)
At Risk Could become dangerous Turn off + advise Rectify soon Now vs could-be
ID vs AR vs NCS UN Immediate danger to life → ID ( Turn off, label ) Fault could become dangerous → AR ( Turn off, advise ) Safe but old standard → NCS ( Advise, leave on ) ID permission refused → Warning notice ( Inform authority ) Live escape can't stop → ECV off ( Call 0800 111 999 ) CO spillage confirmed → ID ( Disconnect appliance ) After rectification → Retest ( Before returning use )
GIUSP Classifications UN GIUSP Unsafe situations procedure Standard IGEM/G/11 ID Immediately Dangerous AR At Risk NCS Not to Current Standards Action Turn off with permission Label Attach warning notice RIDDOR Report dangerous fittings
Emergency Actions UN Gas escape Turn off at ECV Emergency number 0800 111 999 Ventilate Open doors and windows No ignition No flames or switches ID + refusal Warning notice, inform authority Before relight Rectify then tightness test Re-establish Purge before ignition Confirm supply Working pressure at rate
Common Traps
Let-by vs tightness Let-by tests ECV ≠ Tightness tests system
ID vs AR ID immediate danger ≠ AR could become dangerous
Open-flued vs room-sealed Open-flued needs vent ≠ Room-sealed does not
Ratio pass vs fail ≤ 0.004 passes ≠ > 0.004 investigate
Natural gas vs LPG Natural gas rises ≠ LPG sinks low
Standing vs working pressure Standing is off ≠ Working is firing
Last Minute 1 . Test pressure 20-21 mbar, 2 min 2 . Let-by: 7-10 mbar, no rise 3 . Drop: 4 mbar ≤28mm / 2.5 >28mm 4 . New pipework = no drop 5 . Pipework drop max 1 mbar 6 . Bonding within 600mm of meter 7 . Gross CV ≈ 39.5 MJ/m³ 8 . Open-flue vent 5 cm²/kW >7kW 9 . CO/CO₂ ratio ≤ 0.004 passes 10 . GIUSP: ID, AR, NCS 11 . Gas escape → close ECV 12 . Emergency line 0800 111 999 13 . Flue flow test before spillage 14 . Room-sealed = no spillage test
ACS CCN1 Core Domestic Natural Gas Safety Assessment Practice Questions 118 questions Study Guide 34 topics Cheat Sheet 89 facts Flashcards 50 cards Course Playlist 49 videos Blogs 1 blog Podcast
Third-party resources · We may earn a commission from purchases.
Gas Safety Core Revision Guide - Domestic UK: CCN1, CENWAT, MET1 training for ACS (ACS Gas Knowledge for Trainees and Reassessments) By Law, Liam $28.78 · Buy on Amazon
Same family resources Explore More UK Gas Safe / ACS Gas Assessments Continue into nearby exams from the same family. Each card keeps practice questions, study guides, flashcards, videos, and articles in one place.
ACS Commercial Heating (Non-Domestic) Gas Safety Assessment Practice Questions 100 questions Blogs 1 blog
ACS Domestic Central Heating Boilers & Water Heaters Exam Practice Questions 100 questions Blogs 1 blog
ACS Domestic Gas Cookers Exam Practice Questions 100 questions Blogs 1 blog
ACS Domestic Gas Fires & Space Heaters Exam Practice Questions 100 questions Blogs 1 blog
ACS MET1 Domestic Gas Meters (Gas Safe, UK) Practice Questions 100 questions Blogs 1 blog
ACS CCLP1 Core LPG Safety — Permanent Dwellings (Gas Safe, UK) Practice Questions 100 questions
More From This Family Videos and articles for deeper review. Article ACS CCN1 2026: Free Guide to the Core Gas Assessment 11 min read
Independent exam preparation notice OpenExamPrep is an independent education provider, not affiliated with or endorsed by the exam sponsors named on this site. Exam and certification names identify what our resources help you study for; they do not imply sponsorship, approval, or review of our materials. Unless a resource expressly identifies authorized public material, our practice questions are independently developed simulations, not actual, recalled, or sponsor-provided exam items. We aim to reflect publicly available exam outlines and topic information in our study resources. Coverage, format, and difficulty may differ from the actual exam, and we cannot guarantee that every detail is accurate or current. Confirm exam requirements, fees, and policies with the official exam sponsor. Updated 2026-07-24 . Official exam sources checked Not published . This is a study aid only and is not for use during the exam. Gas Safe Register GSIUR 1998 (legislation.gov.uk) IGEM/UP/1B tightness testing IGEM/G/11 GIUSP