Going Onto the Line and Walking Safely

  • Not published of exam
  • Track Clearances Position of Safety Track Geography Walking Routes Crossing Rails

Safe Systems of Work and Safety Roles

  • Not published of exam
  • COSS Responsibilities Hierarchy of Protection Site Warden Warning Safety Briefings Worksafe Procedure

Electrified Lines OLE and Conductor Rail

  • Not published of exam
  • Overhead AC Clearances Conductor DC Clearances Emergency Switch Off Insulated Tools Electrical Hazards

Emergency Procedures and Trackside Warnings

  • Not published of exam
  • Detonator Placement Track Circuit Clips Hand Danger Signals Emergency Phone Calls Trackside Signage

Sentinel Scheme Lifesaving Rules and Fitness

  • Not published of exam
  • Medical Standards Drugs and Alcohol Fatigue Management Log Book Practice Probationary Rules

Quick Facts

  • Qualification Name Personal Track Safety PTS
  • Competence Records Sentinel sponsorship and competence
  • Competence Validity Normally two years
  • Expired PTS Does not authorise work
  • Practice Evidence Sponsor checks recorded competence use
  • New Holder Support Blue helmet until sponsor confirmation
  • Current Core Handbook HB1 Issue 9 currently in force
  • Position of Safety 1.25m through 100mph; 2m above

SAFE Track Clearances WA

  • Stay Alert For Everyone on the line
  • S Safety position before train A Apply correct speed clearance F Face and watch approaching traffic E Exit only when safe

The Four Foot vs Six Foot WA

The Four Foot

  • Between rails of one track
  • Direct train impact zone
  • Enter only when authorized

The Six Foot

  • Between two adjacent tracks
  • Aerodynamic turbulence hazard
  • Never use as refuge
  • Neither space provides safe refuge

Action When Train Approaches WA

  • Train sighted or horn heard → Move to position of safety ( At least ten seconds early )
  • Line speed up to 100mph → Stand 1.25 metres clear ( Measured from nearest rail )
  • Line speed exceeds 100mph → Stand 2.0 metres clear ( Avoid aerodynamic vortex )
  • Standing in position of safety → Face approaching train ( Watch for loose loads )
  • Train passes your location → Remain stationary until clear ( Check other lines before moving )

Permanent Way Track Geography WA

  • The Four Foot Space between two running rails Direct danger zone
  • The Six Foot Space between two adjacent tracks No safe clearance
  • The Ten Foot Wide space between multiple lines Wide way
  • The Cess Outside edge of running rail Not automatically a safe route
  • Standard Gauge 1435 millimetres between rails 4 feet 8.5 inches
  • Rail Head Top surface contacting train wheels Never step on
  • Rail Foot Bottom flat base of rail Baseplate support
  • Ballast Crib Stones packed between consecutive sleepers Track stability

Clearance Under vs Over 100mph WA

Up to 100mph Lines

  • Minimum 1.25 metres distance
  • Measured from nearest rail
  • Standard clearance distance

Over 100mph Lines

  • Minimum 2.0 metres distance
  • Higher aerodynamic vortex suction
  • Enhanced high speed clearance
  • Line speed dictates safe distance

Trackside Safe Clearances WA

  • Position of Safety Through 100mph At least 1.25 metres From nearest approaching-train line
  • Position of Safety Over 100mph At least 2.0 metres From nearest rail
  • On or Near Line Within 3m without permanent separation Or on line itself
  • Platform Engineering or Technical Work Within 1.25 metres of edge On or near line definition
  • Train Approach Warning Time Ten seconds before train passes In safe position
  • Axle Counter Sections Track circuit clips cannot operate counters Never rely on clip alone
  • Line Crossing Rule Cross track at right angles Never walk diagonally
  • Points Mechanism Keep hands clear of switches Crush injury risk

COSS Safety Briefing Pillars SA

  • Every Worker Safe Under Plan
  • E Establish designated position W Walking route identified S System of work defined U Understand and sign pack P Personal PPE confirmed

COSS vs Site Warden Responsibilities SA

Controller of Site Safety

  • Wears blue armlet
  • Delivers mandatory safety briefing
  • Sets up safe system

Site Warden

  • White armlet with blue lettering
  • Monitors static safe work boundaries
  • No other working duties
  • COSS leads while warden monitors

Check the Briefed Safe System SA

  • Relevant lines protected against trains → Keep within safeguarded work limits ( Confirm COSS briefing )
  • Fenced system is briefed → Stay behind approved barrier ( Observe specified clearances )
  • Separated static worksite is briefed → Stay inside safe boundary ( Obey site warden where appointed )
  • Approved warning system is briefed → Know warning and safety position ( Ten seconds safe before arrival )
  • Planned protection cannot be implemented → Stop and ask COSS to replan ( Never improvise lookout protection )

Key Track Safety Roles SA

  • COSS Controller of Site Safety Blue armlet
  • Site Warden Monitors static worksite boundary White armlet; blue lettering
  • PICOP Controls an engineering possession Specified possession responsibilities
  • Engineering Supervisor Controls an engineering worksite Within possession arrangements
  • Person in Charge Controls the work activity Coordinates with COSS
  • Lookout Warns under specifically authorised arrangements White armlet; red lettering
  • Individual Working Alone Authorized to work by oneself IWA competence
  • PTS Competence Alone Does not authorise working alone Additional competence and authority required

Safe Systems of Work Hierarchy SA

  • Safeguarded System Relevant lines protected against train approach Follow authorised limits
  • Fenced System Approved barrier and specified clearances Do not improvise fencing
  • Separated Worksite Specified separation from open lines Site warden where required
  • Track Warning Systems ATWS SATWS TAWS or TOWS Use only approved arrangements
  • Lookout or LOWS Restricted arrangements require specific authority Never an improvised fallback
  • Safe System Pack Authorized plan generated by SSOWP Signed before work
  • COSS Briefing Understand before signing or digital acknowledgement Before access and work
  • Worksafe Procedure Stop and report unsafe work Resolve concern before restarting

AC Overhead vs DC Conductor Rail EL

AC Overhead Line

  • Nominal 25000 volts AC
  • Basic working clearance 2.75 metres
  • Permit specifies isolation and earthing

DC Conductor Rail

  • Nominal 750 volts DC
  • Basic live clearance 1.5 metres
  • Never step between adjacent rails
  • Different systems require different electrical precautions

Electrified Line Emergency Response EL

  • Railway OLE falls or breaks → Keep clear and warn others ( Treat equipment and contacts live )
  • Electrical danger threatens life → Request emergency switch-off through ECO ( Give exact location and hazard )
  • Person contacts live conductor rail → Request switch-off; do not touch ( Rescue only under HB17 conditions )
  • ECO unreachable; person contacts live CRE → Competent person considers short-circuiting bar ( All HB17 application restrictions apply )
  • Guard board or yellow shroud present → Do not apply short-circuiting bar ( Unsafe location for bar )
  • Section gap separates bar and casualty → Do not use that bar location ( Other electrical sections may remain live )
  • Short-circuiting bar has been applied → Notify ECO; obtain removal permission ( Ordinary metal tools are not substitutes )
  • Electricity-company power line has fallen → Stay at least five metres away ( Until electricity company confirms safety )

AC 25kV Overhead Line Equipment EL

  • AC OLE Voltage 25000 volts alternating current Lethal contact risk
  • OLE Working Clearance At least 2.75m every direction Closer work needs approved precautions
  • Live Equipment Rule Treat live until prescribed assurance Switch-off alone is insufficient
  • Pantograph Roof arm collecting electric current High voltage equipment
  • Overhead Line Permit Defines isolated earthed equipment and limits Does not stop trains
  • Traction Bonds Never interfere with any bond Report defects and colour
  • Broken Railway OLE Treat live; keep clear; report Warn others and notify ECO
  • Emergency Switch Off Immediate ECO phone notification Life threatening hazard

DC 750V Conductor Rail Equipment EL

  • DCCR Voltage 750 volts direct current Third rail system
  • Live Conductor Rail Clearance 1.5m basic distance from live equipment Approved exceptions need all precautions
  • Crossing Adjacent Rails Step over both rails together Never place foot between
  • Conductor Guard Board Timber or composite protective cover Never stand on
  • Collector Shoe Gear Treat as live when disconnected too Never touch shoe gear
  • Short Circuiting Bar Specialist HB17 emergency equipment Competence and strict conditions required
  • Flooded Track Warning Never touch water near rails Conducted shock hazard
  • Electrical Protection Ordinary boots do not confer isolation Follow approved electrical precautions

STOP Emergency Track Protection EM

  • Stop, Tell, Observe, Protect within competence
  • S Signal danger when necessary T Tell signaller the exact location O Observe other line dangers P Protection only within training

Emergency Call vs Railway Call EM

Emergency Phone Call

  • State this is emergency
  • Immediate threat to safety
  • Direct signaller or ECO

Railway Related Call

  • Standard structured conversation protocol
  • Routine operational railway messaging
  • Mandatory message read back
  • Danger immediately dictates call urgency

Track Obstruction Emergency Actions EM

  • Track is obstructed or unsafe → Warn signaller by quickest means ( Give location and affected lines )
  • Train approaches affected line → Show clear hand danger signal ( Protect your own safety )
  • Trained to use emergency equipment → Follow applicable HB2 protection procedure ( Clips ineffective on axle counters )
  • Detonator protection becomes necessary → Only trained personnel follow HB2 ( Three; twenty metres; normally 2km )

Emergency Track Protection Equipment EM

  • Detonator Spacing Twenty metres apart under HB2 Trained emergency protection personnel
  • Full Detonator Protection Three detonators on each affected line Applicable HB2 instructions
  • Full Protection Distance Normally two kilometres towards approaching trains Exceptions require HB2 training
  • Track Circuit Clip Operates track circuit when correctly applied Not guaranteed to stop trains
  • Clip Restrictions No fourth rail or conductor attachment Third rail: furthest running rail first
  • Hand Danger Signal Day Red flag; otherwise both arms raised Make visible to driver
  • Hand Danger Signal Night Red light; or wave any light Violently if not red
  • Flashing Train Headlights Train hazard warning indicator Report unsafe train immediately

Safety Critical Communications Protocol EM

  • Emergency Call Phrase This is an emergency call Immediate priority
  • Phonetic Alphabet Standard phonetic letters like Alpha Clarifies spelling
  • Spoken Numbers Normally one digit at a time Exceptions include time and handbook references
  • Lead Responsibility Role hierarchy determines conversation lead Initiator only if otherwise unclear
  • Read Back Protocol Repeat messages verbatim to sender Prevents misunderstandings
  • Telephone Location Confirm correct phone and control contact Know emergency contact details
  • Location Identification State line mileage and bridge Pinpoints worker
  • Signal Post Telephone Identify signal and exact location Confirm correct signaller

Trackside Warning Signs and Indicators EM

  • Limited Clearance Warning No safety position along this side Do not enter with trains running
  • No Refuges Sign Safety positions only on opposite side Follow briefed route
  • Prohibition Sign No access while trains running Specified emergency protection exception
  • Whistle Board W directs driver horn warning Never rely on hearing alone
  • Limited Clearance Telephone May be used only in emergency Check sign and location
  • Applicable Line Speeds Use Sectional Appendix and briefing Do not infer from colour alone

Probationary vs Full PTS Holder SE

Probationary Track Worker

  • Green square: learning support
  • Blue helmet as required
  • Sponsor manages experience requirements

Full Competent Worker

  • Sponsor confirms required competence
  • Helmet change is not automatic
  • Red triangle still requires accompaniment
  • Experience and restrictions require sponsor confirmation

Sentinel Scheme and Sponsorship SE

  • Primary Sponsor One sponsor manages competence and fitness Pays for competences it uses
  • Sub Sponsors Up to two with Primary approval One Primary plus two Sub-Sponsors
  • Green Square New PTS holder receiving learning support Not the accompaniment symbol
  • Blue Helmet Required during new-holder learning support Sponsor confirms sufficient experience
  • Red Triangle Must be accompanied on infrastructure Observe recorded restriction
  • Swipe In Verification Electronic check before entering track Confirms valid card
  • Practice Records Record actual competence used in Sentinel Swipe-in alone is not proof
  • Recertification Admission Window Provider may accept eight weeks late Expired PTS does not authorise work

Medical Fitness and Fatigue Limits SE

  • Medical Standard NR L2 OHS 00124 examination Physical fitness
  • Supply-chain PTS D&A test Negative within three months before training Workforce-specific course requirement
  • Network Rail worker PTS admission Separate three-month pre-course test removed Other D&A duties still apply
  • Alcohol Policy Strict Network Rail zero tolerance Mandatory testing
  • Applicable Working Hours Use shortest applicable working-hour limit Law infrastructure manager and sponsor
  • Previous Twelve Hours No work without approved risk exception Sponsor assessment and controls required
  • Fatigue and Travel Report all work and excessive travel Not just hours on site
  • CIRAS Reporting Confidential independent rail safety reporting Whistleblower service
  • Medication with safety-affecting side effects Seek Chemist on Call guidance Report and follow restrictions

Common Traps

Six Foot Refuge Assumption Trap

  • Normal six-foot is not refuge ≠ Use designated position of safety

Overhead Equipment De-energization Trap

  • Emergency switch-off alone ≠ Isolated and earthed under permit

Conductor Rail Stepping Hazard

  • Guard boards are not footholds ≠ Never step between adjacent rails

Working Alone as PTS Trap

  • PTS alone does not authorise working ≠ COSS or IWA needed when alone

Emergency Telephone Communication Mistake

  • State emergency and exact location ≠ Confirm instructions and repeat back

Last Minute

  • 1. Carry physical or virtual Sentinel card
  • 2. Verify swipe in before work
  • 3. Wear full orange trackside PPE
  • 4. Mentored workers must wear blue
  • 5. Confirm designated position of safety
  • 6. Maintain 2.75 metres from OLE
  • 7. Know authorised conductor-rail working precautions
  • 8. Understand COSS briefing before acknowledging
  • 9. Exercise Worksafe if conditions change

Personal Track Safety (PTS) — Sentinel (Network Rail/NSAR, UK)

  • Practice Questions 149 questions Study Guide 25 topics Cheat Sheet 87 facts Flashcards 50 cards Games 20 terms Blogs 1 blog Podcast
  • Word games 20 terms Guess the Term T E R M S Read the clue and guess the term in 6 tries. Word games 20 terms Term Match Swap tiles to line up three of the same term. Word games 20 terms Term Pairs ? ✓ ✓ ? ? Flip two cards at a time to find matching terms. Word games 20 terms Term Search Q T E R M X Find five hidden terms in a grid of letters.