Cheat sheet
California CSLB C-13 Fencing Contractor Cheat Sheet
Planning and Estimating
- 16% of exam
- C-13 Scope & HIC Rules Takeoff Math & Wire Specs Takeoff & Layout Picker Zoning, Easements & Permits
Preparation and Post Installation
- 18% of exam
- USA 811 & APWA Utility Colors Post Footings, Concrete & Layout Rock, Slope & Wood Posts 3-4-5 Corner Layout
Fence, Gate, and Rail Installation and Repair
- 50% of exam
- Chain-Link Installation Decisions Wood, Vinyl, Ornamental & Ag Pool Barriers, ADA & Guards UL 325 & ASTM F2200 Gates
Safety
- 16% of exam
- Cal/OSHA Trench, Heat & Fall Silica, Welding, Power & Waste Cal/OSHA Safety Picker Auger & High-Voltage Safety
Quick Facts
- Classification CSLB C-13 Fencing
- Delivery Closed-book, four-option MCQ via PSI
- Exam Time 3.5 hours each required exam
- Official Item Count Not published in inspected guide
- PSI Fee $51.43 per exam attempt
- Application Fee $450 separately
- Usual Experience Four years in preceding ten
- Retake Wait 21 days; within 18-month eligibility
- Current Guide References 2025 CBC; current Cal/OSHA
Takeoff & Layout Picker PL
- Straight open run; maximum bay given → Round bays up; add one post ( Separate terminals and shared corners )
- Ordering bagged concrete → Compute volume; divide yield; round up ( Use actual product yield )
- Survey or boundary is disputed → Resolve boundary before layout ( Existing fence is not survey proof )
- Site soil differs from footing detail → Obtain appropriate design clarification ( Do not improvise a rock socket )
- Home-improvement fence contract over $500 → Use current compliant written HIC ( Separate deposit and licensing thresholds )
C-13 Scope & HIC Rules PL
- C-13 Scope Listed fences, gates, posts and flagpoles
- Explicit C-13 Exclusion Masonry walls
- Other Trades Valid classification or applicable incidental-work rule
- Site Boundary Verify survey; do not assume curb
- Permit Exemption Does not waive zoning or safety
- Written HIC Home improvements over $500
- Ordinary HIC Deposit Lesser of $1,000 or 10%
- $8,000 HIC Example $800 ordinary maximum deposit
- Cancellation Notice Transaction-specific three/five/seven-business-day rules
Takeoff Math & Wire Specs PL
- Open-Run Bays ceil(length ÷ maximum spacing)
- Open-Run Posts Bays +1; count shared corners once
- 73ft / 8ft Maximum 10 bays; 11 posts
- Gross Cylinder Volume π × radius² × depth
- Cubic-Foot Conversion 27ft³ =1yd³
- Ten Example Holes 12in diameter; 36in deep; 15% allowance
- Example Concrete Total 27.096ft³ =1.00356yd³
- Example Bag Purchases 61×0.45ft³; or 46×0.60ft³
- Uniform 15% Grade 200ft horizontal →202.24ft sloping
- Specified Band Example 60in span; ≤12in intervals; six bands
- 9ga / 11ga Core 0.148in / 0.120in
- F668 Class 2b Fused-and-adhered polymer coating
Utility Marking Reminders PR
- White excavation; red power; yellow fuel; blue water
- Orange communications Green sewer/drainage Purple reclaimed/irrigation Pink temporary survey
Line and Terminal Post Functions PR
Line Post
- Supports intermediate fabric
- Spacing selected for structural loads
- Uses specified fabric ties
Terminal Post
- Takes end, corner or gate loads
- Requires appropriate anchorage and bracing
- Uses specified terminal attachments
- Footing design is not role-only arithmetic
USA 811 & APWA Utility Colors PR
- Normal 811 Notice Two working to fourteen calendar days
- Notice-Day Calculation Exclude notification day, weekends and holidays
- Normal Ticket Validity 28 calendar days; renew before expiration
- Before Excavation Resolve responses, markings and utility conflicts
- Tolerance-Zone Width 24in beyond each utility outside edge
- Six-Inch Utility Example 24+6+24 =54in total width
- White / Pink Proposed excavation / temporary survey
- Red / Yellow Electric / gas, oil, steam
- Orange / Green Communications / sewer and drainage
- Blue / Purple Potable / reclaimed, irrigation, slurry
Footing Design Checks PR
- Post; loads; soil; frost; detail; readiness
- Use specified foundation dimensions Resolve changed ground conditions Gate posts may require more Verify concrete before loading
Post Footings, Concrete & Layout PR
- 9–12–15 Layout 9²+12²=15²; right-angle corner
- Rectangle Check Sides and diagonals; not diagonals alone
- CLFMI Template Diameter ≤4in OD:4×; >4in OD:3×
- 2.375in Post Example 4×2.375 =9.5in; larger requirements may govern
- CLFMI Template Depth 4ft fence:24in; +3in/additional foot
- Six-Foot Fence Example Template minimum 30in; site may govern
- Gate Footings Larger design requirements may apply
- Loading Fresh Concrete Specified strength/readiness; not elapsed-time guess
- Rock / Expansive Soil Obtain suitable foundation/anchorage detail
- Wood Ground Contact Appropriate treatment; field-cut protection
- Drainage Detail Gravel cannot guarantee drainage in clay
- Ordinary Plumb-Post Design Check two planes; respect panel geometry
HSC Enclosure Measurements FE
- Sixty high; two below; reject four; sixty latch
- Height ≥60in Bottom clearance ≤2in Reject sphere ≥4in Gate latch ≥60in above ground
Simple Gate Diagonal Load Paths FE
Compression Brace
- Rigid member
- Lower hinge to upper latch
- Transfers load through compression
Tension Cable
- Flexible tensile member
- Upper hinge to lower latch
- Supports free corner through tension
- Check foundations and connections before adjustment
Fence & Gate Installation Picker FE
- Terminal brace shown on design → Install compression rail and tension rod ( Rod lower-terminal to upper-adjacent )
- Simple gate uses rigid diagonal brace → Lower hinge to upper latch ( Compression load path )
- Simple gate uses flexible diagonal cable → Upper hinge to lower latch ( Tension load path )
- Cantilever detail specifies 40% back frame → 20ft opening needs 8ft back frame ( Project example; not every product )
- Adding privacy screen to existing fence → Review wind load and structural capacity ( Do not merely add ties )
Chain-Link Installation Decisions FE
- CLFMI Line-Post Interval At most 10ft; design may reduce
- Fabric Mounting Side Inside or outside as specified
- Knuckled Selvedge Wire ends loop back
- Twisted Selvedge Wire ends form projecting points
- Template Terminal Bracing ≥6ft; also 5ft without toprail
- Conventional Terminal Truss Lower terminal → upper adjacent brace
- Template Post Attachments At most 12in on centre
- Template Rail / Hog Rings At most 18in on centre
- Fabric Tension Taut without distorted mesh or sag
- Matching Fabric Splice Reweave compatible spiral picket
- Windscreen Added Review loads, posts, footings and attachments
Knuckled and Twisted Selvedges FE
Knuckled
- Ends folded into loops
- Reduces projecting sharp points
- Specify for actual contact conditions
Twisted
- Ends twisted into projecting points
- May serve specified security purpose
- Check location and local restrictions
- No universal six/seven-foot selection boundary
Pool & Automated Gate Code Picker FE
- Selecting two pool safety features → Check permitted pair and local requirements ( Alarm+latch is not two )
- Installing HSC115923 enclosure gate → Outward; self-closing; latch ≥60in above ground ( Do not substitute house-door height )
- Selecting automated gate protection → Map zones; use listed compatible means ( External devices must be monitored )
- CSL24UL Class I–III slide gate → Apply screening, gaps, guards and stops ( Screen includes back frame )
- Checking accessible pedestrian gate → Measure clear passage and maneuvering space ( Nominal width alone is insufficient )
Wood, Vinyl, Ornamental & Ag FE
- Wood Fasteners Compatible with treatment and exposure
- Wood Rail Schedule Designed size, count and post spacing
- Gate Compression Brace Lower hinge → upper latch
- Gate Tension Cable Upper hinge → lower latch
- Vinyl Expansion Use product-specific engagement and clearance
- Gate Reinforcement Use rated insert and anchorage assembly
- Coating Repairs Compatible preparation, repair coating and topcoat
- Rackable / Stepped Panels Designed movement / horizontal panel steps
- Supplier 1047-6-12.5 Example 10 wires;47in;6in stays;12.5ga
- Conventional Agricultural H-Brace Horizontal compression; diagonal wire tension
- Specified 40% Tail Example 20ft opening +8ft tail =28ft
- Flagpole Foundation Design for pole, flag, wind, soil
Guard and Handrail Functions FE
Guard
- Limits falls from exposed edges
- Height follows applicable guard requirements
- Openings and loading also matter
Handrail
- Provides graspable support
- Typical gripping height 34–38in
- Clearance and extensions also matter
- A combined assembly must satisfy both
Pool Barriers and Accessible Gates FE
- Covered Pool Permit At least two qualifying safety features
- Rejected Safety Pair Exit alarm +door latch
- Another Rejected Pair Safety cover +in-water alarm
- HSC Enclosure Height At least 60in
- HSC Ground Clearance At most 2in
- HSC Openings Reject sphere ≥4in
- HSC Exterior No child-climbable handholds or footholds
- HSC Enclosure Gate Outward; self-closing; latch ≥60in above ground
- Home Door Device Release ≥54in above floor; different rule
- Accessible Clear Opening 32in baseline; measure actual passage
- Gate Push-Side Surface Normally bottom 10in smooth; exceptions apply
- Handrail Gripping Height 34–38in baseline; distinct from guard
Cantilever and Ground-Track Gates FE
Cantilever
- Support outside roadway opening
- Designed back frame or support geometry
- No wheel track across opening
Ground-Track Rolling
- Wheels follow roadway track
- Track must remain aligned
- Debris can obstruct movement
- Use the actual system structural design
UL 325 & ASTM F2200 Gates FE
- Usage Classes I residential;II general;III industrial;IV guarded
- Entrapment Assessment Identify every zone and travel direction
- Independent Protection Means Different acceptable types; not two photoeyes
- External Safety Devices Compatible, monitored and correctly positioned
- Horizontal Slide Operator Typically two means in each direction
- Other Operator Types Direction-specific conditions and exceptions apply
- CSL24UL Class I–III Screen Reject 2¼in sphere through min(top,6ft)
- Screened Moving Portion Include back frame and covered fence
- CSL24UL Exposed Rollers Guard at eight feet or lower
- CSL24UL Near-Roadway Gap ≤2¼in; specified >16in exception
- Positive Stops Limit both open and closed travel
- CSL24UL Normal Access Control ≥6ft; prevent reaching moving gate
- Stop / Reset Control Within sight; reset must not start
- Pedestrian Access Separate from moving vehicular-gate path
- Warning Signs Visible from both sides
Excavation Checks Have Different Triggers SA
- Edge materials; egress; cave-ins; permit
- 2ft setback or effective retention 4ft trench:egress within25ft Cave-in exceptions require actual conditions 5ft/descent permit:check listed exceptions
Outdoor Shade and High-Heat Thresholds SA
Above 80°F
- Shade must be present
- Enough for recovery/rest users
- At/below80°F: timely shade on request
At Least 95°F
- Construction high-heat procedures apply
- Effective monitoring and communication
- Preshift meeting and drinking reminders
- Above80 differs from at-least95
Cal/OSHA Safety Picker SA
- Utility marks or responses conflict → Stop; resolve before excavation ( 811 ticket is not a clearance )
- Worker entry planned in excavation → Competent-person assessment; protective system as required ( Permit is a separate obligation )
- Construction temperature reaches 95°F → Implement high-heat procedures ( Water, monitoring, communication and reminders )
- Concrete drilling task selected → Implement exact silica Table1 row ( Or assessed-exposure compliance route )
- Handling rails near unidentified powerlines → Stop; establish voltage and safe plan ( Include full material movement envelope )
Cal/OSHA Trench, Heat & Fall SA
- Cave-In Protection Stable-rock/competent-person exceptions are conditional
- Under-Five-Foot Exception Competent person finds no cave-in indication
- Trench Egress Depth ≥4ft; travel ≤25ft
- Edge Materials ≥2ft setback or effective retaining devices
- Excavation Permit Generally ≥5ft with descent; exceptions apply
- Water Availability 1qt hourly per worker; replenish effectively
- Eight-Hour Water Example 8qt per worker available
- Shade Present Temperature >80°F
- Shade at ≤80°F Timely access on request
- Construction High Heat Temperature ≥95°F
- High-Heat Observation Effective monitoring; buddy system one option
- New High-Heat Assignment Close observation for first fourteen days
- Section 1670(a) Specified unprotected falls >7½ft
- Portable Ladder Pitch Setback ≈one-quarter working length
- Upper-Landing Access 3ft extension; permitted alternative if impracticable
Silica, Welding, Power & Waste SA
- Silica Eight-Hour Levels 25µg/m³ action;50µg/m³ PEL
- Table 1 Compliance Use exact task controls and respirators
- Rig-Mounted Core Drilling Integrated water at cutting surface
- Handheld Drill Dust Shroud/collector; HEPA vacuum for holes
- Auger Jams Stop and isolate before clearing
- Galvanized Hot Work Assess zinc-fume exposure; suitable controls
- 2946:600–50,000V Handled Material 6ft baseline approach clearance
- 2946:Corresponding Boom Table 10ft baseline; other equipment rules differ
- Concrete Washout Contain; prevent uncontrolled discharge
- Treated Wood Waste DTSC route; authorized accepting facility
Common Traps
Contract Thresholds
- Written home-improvement contract threshold ≠ Conditional contractor-license exemption threshold
Pool Access Hardware
- Enclosure gate:60in above ground ≠ Home door:54in above floor
Gate Bracing
- Rigid member carries compression ≠ Flexible cable carries tension
Heat Boundaries
- Shade present above80°F ≠ High-heat procedures at-least95°F
Gate Width
- Nominal gate-leaf dimension ≠ Measured unobstructed passage width
Safety Equipment
- Compatible monitored entrapment device ≠ Vehicle detection/access-control loop
Concrete Capacity
- Specified 28-day strength ≠ Verified early loading readiness
Excavation Requirements
- Permit authorization ≠ Actual cave-in protection
Last Minute
- 1. Approximate weights:16/18/50/16
- 2. Real item count is unpublished
- 3. 3.5h each required exam
- 4. PSI fee separate from application
- 5. Takeoff units and endpoint assumptions matter
- 6. Round purchase quantities upward
- 7. Resolve 811 responses and utility conflicts
- 8. Footings depend on loads and ground
- 9. Compression and tension braces differ
- 10. Pool enclosure and home-door rules differ
- 11. Map every gate entrapment zone
- 12. Check accessible clear opening
- 13. Water:8qt availability over8h
- 14. Shade >80°F; high heat ≥95°F
- 15. Use task-specific silica controls
- 16. Apply actual overhead-line equipment rule
California CSLB C-13 Fencing Examination
- Practice Questions 107 questions Cheat Sheet 118 facts Flashcards 50 cards Games 20 terms Shorts 3 short s Podcast
- Word games 20 terms Guess the Term T E R M S Read the clue and guess the term in 6 tries. Word games 20 terms Term Match Swap tiles to line up three of the same term. Word games 20 terms Term Pairs ? ✓ ✓ ? ? Flip two cards at a time to find matching terms. Word games 20 terms Term Search Q T E R M X Find five hidden terms in a grid of letters.
Same family resources
- Explore More California CSLB Contractor Trade Examinations
- Continue into nearby exams from the same family. Each card keeps practice questions, study guides, flashcards, videos, and articles in one place.
California CSLB C-36 Plumbing Contractor
- Practice Questions 163 questions Videos 1 video Blogs 1 blog
California CSLB A General Engineering Examination
- Practice Questions 100 questions Shorts 2 short s
California CSLB ASB Asbestos Certification Examination
- Practice Questions 100 questions
California CSLB B-2 Residential Remodeling Contractor Examination
- Practice Questions 100 questions Shorts 4 short s
California CSLB C-10 Electrical Examination
- Practice Questions 100 questions Shorts 3 short s
California CSLB C-11 Elevator Examination
- Practice Questions 100 questions
More From This Family
- Videos and articles for deeper review.
- Video Free Journeyman Plumber Practice Test by State: 2026 Guide Article Free Journeyman Plumber Practice Test by State: 2026 Guide 18 min read