Cheat sheet
USPS Postal Exam 955 Cheat Sheet
Electronics
- 18% of exam
- Logic Gate Truth Tables Analog & Semiconductor Devices Schematics & Test Instruments Analog vs Digital Signals Test Tool Picker
Electrical
- 14% of exam
- Ohm's Law & Power Formulas Circuit & Current Types Series vs Parallel Circuits AC vs DC Motors & Controls
Mechanical
- 14% of exam
- Gears, Belts & Mechanical Advantage Hydraulics & Pneumatics Rigging & Power Transmission Welding & Shop Tools Gear Up vs Gear Down
HVAC & Refrigeration
- 12% of exam
- Refrigeration Cycle HVAC Controls & Piping HVAC Fault Troubleshooting Superheat vs Subcooling
Computers & Networking
- 12% of exam
- Computers & Networking IP Networking Basics PLC & Control Systems PC Hardware Basics
Spatial Reasoning
- 12% of exam
- Spatial Reasoning Skills Object Rotation Paper Folding Assembly Visualization
Math Reasoning
- 10% of exam
- Math & Unit Conversions Area & Volume Formulas Unit Conversions Electrical Math
Safety
- 8% of exam
- Lockout/Tagout & Hazcom Lockout vs Tagout LOTO Six-Step Sequence Arc Flash & PPE
Quick Facts
- Exam USPS 955
- Format 2 Parts
- Part 1 120 Q Take-Home
- Part 2 60 Q + Spatial
- Time ~2 hr 15 min
- Pass Score 70 Minimum
- Fee Free
- Proctor PSI Testing Center
- Validity ~2 Years
Logic Gate Memory Cues EL
- AND needs all; OR needs one
- AND: all inputs 1 OR: any input 1 NOT: flips the input XOR: inputs must differ
Analog vs Digital Signals EL
Analog
- Continuous signal range
- Infinite value gradations
- More sensitive to noise
Digital
- Discrete on/off states
- Binary 0s and 1s
- More resistant to noise
- Continuous vs discrete values
Test Tool Picker EL
- Measure voltage, current, resistance → Multimeter ( General purpose )
- View a waveform shape → Oscilloscope ( Signal timing )
- Check motor winding insulation → Megohmmeter ( Insulation resistance )
- Measure current, no contact → Clamp meter ( Live circuit safe )
Logic Gate Truth Tables EL
- AND 1 only if all inputs 1
- OR 1 if any input 1
- NOT Inverts single input
- NAND 0 only if all inputs 1
- NOR 1 only if all inputs 0
- XOR 1 if inputs differ
- XNOR 1 if inputs match
Analog & Semiconductor Devices EL
- Diode Allows current one direction
- Transistor Amplifies or switches signals
- Resistor Limits or controls current
- Capacitor Stores energy as charge
- Op-amp High-gain differential voltage amplifier
- Semiconductor Conducts under controlled conditions
- Rectifier Converts AC to DC
- LED Emits light when powered
Schematics & Test Instruments EL
- Multimeter Measures voltage, current, resistance
- Oscilloscope Displays signal waveform shape
- Megohmmeter Tests insulation resistance value
- Clamp meter Measures current without contact
- Schematic symbol Represents a component type
- Continuity test Confirms a closed path
Ohm's Law Triangle EL
- Cover unknown: V top, I×R bottom
- V = I × R I = V ÷ R R = V ÷ I
Series vs Parallel Circuits EL
Series
- Single current path
- Voltage divides across loads
- Current stays the same
Parallel
- Multiple current paths
- Voltage stays the same
- Current divides across branches
- One path vs many paths
Circuit Fault Troubleshooting EL
- No voltage at load → Check breaker or fuse ( Power source )
- Voltage present, no current → Check for open circuit ( Broken path )
- Breaker trips repeatedly → Check for short circuit ( Low resistance )
- Motor will not start → Check overload relay reset ( Thermal trip )
- Connection is intermittent → Check terminals for corrosion ( Loose contact )
- Suspect a bad component → Meter it, compare spec ( Continuity check )
Ohm's Law & Power Formulas EL
- V = I × R Voltage equals current times resistance
- I = V ÷ R Current equals voltage over resistance
- R = V ÷ I Resistance equals voltage over current
- P = V × I Power equals voltage times current
- P = I² × R Power equals current squared times resistance
- P = V² ÷ R Power equals voltage squared over resistance
AC vs DC EL
AC
- Current direction alternates
- Easily transformed voltage levels
- Used for long-distance transmission
DC
- Current direction constant
- Powers batteries and electronics
- No transformer voltage stepping
- Alternating vs constant direction
Circuit & Current Types EL
- Series circuit Single current path only
- Parallel circuit Multiple current paths exist
- Short circuit Unintended low-resistance current path
- Open circuit Broken, incomplete current path
- AC Current direction alternates repeatedly
- DC Current direction stays constant
- Three-phase power Three offset AC waveforms
- Ground fault Current leaks to ground
Relay vs Contactor EL
Relay
- Switches low-current control signals
- Small load switching
Contactor
- Switches high-current power loads
- Motor and heater switching
- Control signal vs power load
Motors & Controls EL
- Motor starter Controls motor start, stop
- Overload relay Protects motor from overcurrent
- Contactor Switches high-power circuits closed
- Solenoid Electromagnetic linear motion actuator
- VFD Variable frequency drive control
- Single-phase motor One AC waveform input
Open vs Short Circuit EL
Open Circuit
- Broken current path
- Zero current flows
- Infinite resistance reading
Short Circuit
- Unintended low-resistance path
- Excess current flows
- Near-zero resistance reading
- No path vs wrong path
Mechanical Advantage Rule ME
- Longer lever arm means less force
- MA = output ÷ input Longer arm: more advantage Trade force for distance
Hydraulics vs Pneumatics ME
Hydraulics
- Incompressible liquid medium
- High force output
- Smoother, more precise control
Pneumatics
- Compressible air medium
- Faster, lighter force
- Less precise control
- Liquid force vs air speed
Mechanical Fault Troubleshooting ME
- Belt slipping or squealing → Check tension and alignment ( Power transmission )
- Excess vibration present → Check bearing wear, balance ( Rotating parts )
- Gear noise or backlash → Check gear mesh, lubrication ( Wear pattern )
- Hydraulic power loss → Check fluid level, leaks ( Pressure loss )
- Pneumatic cylinder runs slow → Check air pressure, filters ( Restricted flow )
- Chain jumps the sprocket → Check chain wear, tension ( Elongation )
Gears, Belts & Mechanical Advantage ME
- Gear ratio Driven teeth ÷ driver teeth
- Belt drive Pulley-to-pulley power transfer
- Lever Multiplies force around pivot
- Pulley Redirects or multiplies force
- Bearing Reduces friction, supports load
- Mechanical advantage Output force ÷ input force
- Torque Rotational turning force applied
- Chain drive Sprocket-to-sprocket power transfer
Gear Up vs Gear Down ME
Gear Up
- Increases output speed
- Reduces output torque
Gear Down
- Decreases output speed
- Increases output torque
- Speed trade vs torque trade
Hydraulics & Pneumatics ME
- Hydraulics Uses pressurized liquid power
- Pneumatics Uses pressurized air power
- Pascal's Law Pressure transmits equally through fluid
- Actuator Converts pressure into motion
- PSI (pressure unit) Pounds per square inch
- Relief valve Limits maximum system pressure
- Check valve Allows one-way fluid flow
Rigging & Power Transmission ME
- Sling angle Changes rated lifting capacity
- Working load limit Maximum safe lifting weight
- Shaft coupling Connects two rotating shafts
- Sheave Grooved wheel guides cable
- Keyway Locks gear to shaft
- Bushing Wear-resistant sleeve on shaft
Welding & Shop Tools ME
- MIG welding Wire-fed gas-shielded weld process
- TIG welding Tungsten arc, precise weld
- Arc welding Stick electrode weld process
- Micrometer Measures precise small dimensions
- Torque wrench Applies a measured torque
- Feeler gauge Measures small gap width
Refrigeration Cycle Order HV
- Compress, Condense, Expand, Evaporate, repeat
- Compressor raises pressure Condenser rejects heat Expansion valve drops pressure Evaporator absorbs heat
HVAC Fault Troubleshooting HV
- No cooling output → Check compressor, refrigerant charge ( Low charge )
- High head pressure → Check condenser airflow, fins ( Poor heat rejection )
- Low suction pressure → Check evaporator airflow, filter ( Restricted flow )
- System cycles too frequently → Check thermostat, pressure switch ( Control fault )
Refrigeration Cycle HV
- Compressor Raises refrigerant pressure, temperature
- Condenser Rejects heat, condenses refrigerant
- Expansion valve Drops pressure before evaporator
- Evaporator Absorbs heat, boils refrigerant
- Superheat Vapor temperature above boiling point
- Subcooling Liquid temperature below condensing point
HVAC Controls & Piping HV
- Thermostat Controls the temperature setpoint
- Pressure switch Cuts power at threshold
- Schrader valve Access port for refrigerant
- Piping insulation Prevents heat, condensation loss
- Threaded joint Screwed pipe fitting connection
- Soldered joint Heat-bonded copper pipe joint
Computers & Networking CO
- IP address Identifies a device online
- RJ45 Copper Ethernet cable connector
- Fiber optic Sends data using light
- RAM Temporary working memory storage
- CPU Processes computer instructions
- USB Serial peripheral connection standard
- PLC Programmable logic control computer
- Router Directs network traffic paths
Spatial Reasoning Skills SP
- Rotation Object turned around an axis
- Paper folding Predicts a punched-hole pattern
- Mirror image Reversed, flipped left-right orientation
- Assembly visualization Parts combine into a whole
- Block counting Counts hidden cube faces
- Isometric view 3D drawing at equal angles
Math & Unit Conversions MA
- Area Length × width
- Volume Length × width × height
- Circumference π × diameter
- °F to °C Subtract 32, then divide 1.8
- Feet to inches Multiply by 12
- Watts to horsepower Divide by 746
LOTO Six-Step Sequence SA
- Notify, Shutdown, Isolate, Lock, Release, Verify
- Notify affected employees Shut down equipment fully Isolate the energy source Lock and tag device Release any stored energy Verify zero energy state
Lockout vs Tagout SA
Lockout
- Physical lock device used
- Prevents energy release
Tagout
- Warning tag only used
- Relies on communication alone
- Lock prevents; tag warns
Lockout/Tagout & Hazcom SA
- LOTO Isolate energy, then verify
- Arc flash boundary Safe minimum approach distance
- PPE Personal protective equipment gear
- SDS Safety Data Sheet document
- Hazcom Hazard Communication Standard rules
- Confined space Limited entry, permit-required area
Common Traps
Lockout ≠ Tagout
- Lockout physically prevents operation ≠ Tagout only warns, no lock
Series ≠ Parallel Voltage
- Series divides voltage across loads ≠ Parallel keeps voltage equal always
Hydraulics ≠ Pneumatics
- Hydraulics uses incompressible liquid power ≠ Pneumatics uses compressible air power
Relay ≠ Contactor
- Relay switches low-current control signals ≠ Contactor switches high-current power loads
Open ≠ Short Circuit
- Open circuit stops all current ≠ Short circuit causes excess current
AND ≠ OR Gate
- AND needs every input high ≠ OR needs just one input
Superheat ≠ Subcooling
- Superheat measures the vapor side ≠ Subcooling measures the liquid side
Last Minute
- 1. V = I × R
- 2. Series: one path, divided voltage
- 3. Parallel: many paths, equal voltage
- 4. AND needs all inputs high
- 5. LOTO: isolate, lock, then verify
- 6. Hydraulics = liquid; pneumatics = air
- 7. Passing score = 70 minimum
- 8. Part 1 home; Part 2 proctored
- 9. Compressor raises pressure and temperature
- 10. PPE must match the hazard
- 11. Exam fee = $0 always
- 12. Eligibility register lasts about 2 years
USPS Postal Exam 955 (Technical Maintenance)
- Practice Questions 162 questions Study Guide 37 topics Cheat Sheet 106 facts Flashcards 50 cards Shorts 3 short s Podcast