Cheat sheet

USPS Postal Exam 955 Cheat Sheet

Practice this exam

Electronics

  • 18% of exam
  • Logic Gate Truth Tables Analog & Semiconductor Devices Schematics & Test Instruments Analog vs Digital Signals Test Tool Picker

Electrical

  • 14% of exam
  • Ohm's Law & Power Formulas Circuit & Current Types Series vs Parallel Circuits AC vs DC Motors & Controls

Mechanical

  • 14% of exam
  • Gears, Belts & Mechanical Advantage Hydraulics & Pneumatics Rigging & Power Transmission Welding & Shop Tools Gear Up vs Gear Down

HVAC & Refrigeration

  • 12% of exam
  • Refrigeration Cycle HVAC Controls & Piping HVAC Fault Troubleshooting Superheat vs Subcooling

Computers & Networking

  • 12% of exam
  • Computers & Networking IP Networking Basics PLC & Control Systems PC Hardware Basics

Spatial Reasoning

  • 12% of exam
  • Spatial Reasoning Skills Object Rotation Paper Folding Assembly Visualization

Math Reasoning

  • 10% of exam
  • Math & Unit Conversions Area & Volume Formulas Unit Conversions Electrical Math

Safety

  • 8% of exam
  • Lockout/Tagout & Hazcom Lockout vs Tagout LOTO Six-Step Sequence Arc Flash & PPE

Quick Facts

  • Exam USPS 955
  • Format 2 Parts
  • Part 1 120 Q Take-Home
  • Part 2 60 Q + Spatial
  • Time ~2 hr 15 min
  • Pass Score 70 Minimum
  • Fee Free
  • Proctor PSI Testing Center
  • Validity ~2 Years

Logic Gate Memory Cues EL

  • AND needs all; OR needs one
  • AND: all inputs 1 OR: any input 1 NOT: flips the input XOR: inputs must differ

Analog vs Digital Signals EL

Analog

  • Continuous signal range
  • Infinite value gradations
  • More sensitive to noise

Digital

  • Discrete on/off states
  • Binary 0s and 1s
  • More resistant to noise
  • Continuous vs discrete values

Test Tool Picker EL

  • Measure voltage, current, resistance → Multimeter ( General purpose )
  • View a waveform shape → Oscilloscope ( Signal timing )
  • Check motor winding insulation → Megohmmeter ( Insulation resistance )
  • Measure current, no contact → Clamp meter ( Live circuit safe )

Logic Gate Truth Tables EL

  • AND 1 only if all inputs 1
  • OR 1 if any input 1
  • NOT Inverts single input
  • NAND 0 only if all inputs 1
  • NOR 1 only if all inputs 0
  • XOR 1 if inputs differ
  • XNOR 1 if inputs match

Analog & Semiconductor Devices EL

  • Diode Allows current one direction
  • Transistor Amplifies or switches signals
  • Resistor Limits or controls current
  • Capacitor Stores energy as charge
  • Op-amp High-gain differential voltage amplifier
  • Semiconductor Conducts under controlled conditions
  • Rectifier Converts AC to DC
  • LED Emits light when powered

Schematics & Test Instruments EL

  • Multimeter Measures voltage, current, resistance
  • Oscilloscope Displays signal waveform shape
  • Megohmmeter Tests insulation resistance value
  • Clamp meter Measures current without contact
  • Schematic symbol Represents a component type
  • Continuity test Confirms a closed path

Ohm's Law Triangle EL

  • Cover unknown: V top, I×R bottom
  • V = I × R I = V ÷ R R = V ÷ I

Series vs Parallel Circuits EL

Series

  • Single current path
  • Voltage divides across loads
  • Current stays the same

Parallel

  • Multiple current paths
  • Voltage stays the same
  • Current divides across branches
  • One path vs many paths

Circuit Fault Troubleshooting EL

  • No voltage at load → Check breaker or fuse ( Power source )
  • Voltage present, no current → Check for open circuit ( Broken path )
  • Breaker trips repeatedly → Check for short circuit ( Low resistance )
  • Motor will not start → Check overload relay reset ( Thermal trip )
  • Connection is intermittent → Check terminals for corrosion ( Loose contact )
  • Suspect a bad component → Meter it, compare spec ( Continuity check )

Ohm's Law & Power Formulas EL

  • V = I × R Voltage equals current times resistance
  • I = V ÷ R Current equals voltage over resistance
  • R = V ÷ I Resistance equals voltage over current
  • P = V × I Power equals voltage times current
  • P = I² × R Power equals current squared times resistance
  • P = V² ÷ R Power equals voltage squared over resistance

AC vs DC EL

AC

  • Current direction alternates
  • Easily transformed voltage levels
  • Used for long-distance transmission

DC

  • Current direction constant
  • Powers batteries and electronics
  • No transformer voltage stepping
  • Alternating vs constant direction

Circuit & Current Types EL

  • Series circuit Single current path only
  • Parallel circuit Multiple current paths exist
  • Short circuit Unintended low-resistance current path
  • Open circuit Broken, incomplete current path
  • AC Current direction alternates repeatedly
  • DC Current direction stays constant
  • Three-phase power Three offset AC waveforms
  • Ground fault Current leaks to ground

Relay vs Contactor EL

Relay

  • Switches low-current control signals
  • Small load switching

Contactor

  • Switches high-current power loads
  • Motor and heater switching
  • Control signal vs power load

Motors & Controls EL

  • Motor starter Controls motor start, stop
  • Overload relay Protects motor from overcurrent
  • Contactor Switches high-power circuits closed
  • Solenoid Electromagnetic linear motion actuator
  • VFD Variable frequency drive control
  • Single-phase motor One AC waveform input

Open vs Short Circuit EL

Open Circuit

  • Broken current path
  • Zero current flows
  • Infinite resistance reading

Short Circuit

  • Unintended low-resistance path
  • Excess current flows
  • Near-zero resistance reading
  • No path vs wrong path

Mechanical Advantage Rule ME

  • Longer lever arm means less force
  • MA = output ÷ input Longer arm: more advantage Trade force for distance

Hydraulics vs Pneumatics ME

Hydraulics

  • Incompressible liquid medium
  • High force output
  • Smoother, more precise control

Pneumatics

  • Compressible air medium
  • Faster, lighter force
  • Less precise control
  • Liquid force vs air speed

Mechanical Fault Troubleshooting ME

  • Belt slipping or squealing → Check tension and alignment ( Power transmission )
  • Excess vibration present → Check bearing wear, balance ( Rotating parts )
  • Gear noise or backlash → Check gear mesh, lubrication ( Wear pattern )
  • Hydraulic power loss → Check fluid level, leaks ( Pressure loss )
  • Pneumatic cylinder runs slow → Check air pressure, filters ( Restricted flow )
  • Chain jumps the sprocket → Check chain wear, tension ( Elongation )

Gears, Belts & Mechanical Advantage ME

  • Gear ratio Driven teeth ÷ driver teeth
  • Belt drive Pulley-to-pulley power transfer
  • Lever Multiplies force around pivot
  • Pulley Redirects or multiplies force
  • Bearing Reduces friction, supports load
  • Mechanical advantage Output force ÷ input force
  • Torque Rotational turning force applied
  • Chain drive Sprocket-to-sprocket power transfer

Gear Up vs Gear Down ME

Gear Up

  • Increases output speed
  • Reduces output torque

Gear Down

  • Decreases output speed
  • Increases output torque
  • Speed trade vs torque trade

Hydraulics & Pneumatics ME

  • Hydraulics Uses pressurized liquid power
  • Pneumatics Uses pressurized air power
  • Pascal's Law Pressure transmits equally through fluid
  • Actuator Converts pressure into motion
  • PSI (pressure unit) Pounds per square inch
  • Relief valve Limits maximum system pressure
  • Check valve Allows one-way fluid flow

Rigging & Power Transmission ME

  • Sling angle Changes rated lifting capacity
  • Working load limit Maximum safe lifting weight
  • Shaft coupling Connects two rotating shafts
  • Sheave Grooved wheel guides cable
  • Keyway Locks gear to shaft
  • Bushing Wear-resistant sleeve on shaft

Welding & Shop Tools ME

  • MIG welding Wire-fed gas-shielded weld process
  • TIG welding Tungsten arc, precise weld
  • Arc welding Stick electrode weld process
  • Micrometer Measures precise small dimensions
  • Torque wrench Applies a measured torque
  • Feeler gauge Measures small gap width

Refrigeration Cycle Order HV

  • Compress, Condense, Expand, Evaporate, repeat
  • Compressor raises pressure Condenser rejects heat Expansion valve drops pressure Evaporator absorbs heat

HVAC Fault Troubleshooting HV

  • No cooling output → Check compressor, refrigerant charge ( Low charge )
  • High head pressure → Check condenser airflow, fins ( Poor heat rejection )
  • Low suction pressure → Check evaporator airflow, filter ( Restricted flow )
  • System cycles too frequently → Check thermostat, pressure switch ( Control fault )

Refrigeration Cycle HV

  • Compressor Raises refrigerant pressure, temperature
  • Condenser Rejects heat, condenses refrigerant
  • Expansion valve Drops pressure before evaporator
  • Evaporator Absorbs heat, boils refrigerant
  • Superheat Vapor temperature above boiling point
  • Subcooling Liquid temperature below condensing point

HVAC Controls & Piping HV

  • Thermostat Controls the temperature setpoint
  • Pressure switch Cuts power at threshold
  • Schrader valve Access port for refrigerant
  • Piping insulation Prevents heat, condensation loss
  • Threaded joint Screwed pipe fitting connection
  • Soldered joint Heat-bonded copper pipe joint

Computers & Networking CO

  • IP address Identifies a device online
  • RJ45 Copper Ethernet cable connector
  • Fiber optic Sends data using light
  • RAM Temporary working memory storage
  • CPU Processes computer instructions
  • USB Serial peripheral connection standard
  • PLC Programmable logic control computer
  • Router Directs network traffic paths

Spatial Reasoning Skills SP

  • Rotation Object turned around an axis
  • Paper folding Predicts a punched-hole pattern
  • Mirror image Reversed, flipped left-right orientation
  • Assembly visualization Parts combine into a whole
  • Block counting Counts hidden cube faces
  • Isometric view 3D drawing at equal angles

Math & Unit Conversions MA

  • Area Length × width
  • Volume Length × width × height
  • Circumference π × diameter
  • °F to °C Subtract 32, then divide 1.8
  • Feet to inches Multiply by 12
  • Watts to horsepower Divide by 746

LOTO Six-Step Sequence SA

  • Notify, Shutdown, Isolate, Lock, Release, Verify
  • Notify affected employees Shut down equipment fully Isolate the energy source Lock and tag device Release any stored energy Verify zero energy state

Lockout vs Tagout SA

Lockout

  • Physical lock device used
  • Prevents energy release

Tagout

  • Warning tag only used
  • Relies on communication alone
  • Lock prevents; tag warns

Lockout/Tagout & Hazcom SA

  • LOTO Isolate energy, then verify
  • Arc flash boundary Safe minimum approach distance
  • PPE Personal protective equipment gear
  • SDS Safety Data Sheet document
  • Hazcom Hazard Communication Standard rules
  • Confined space Limited entry, permit-required area

Common Traps

Lockout ≠ Tagout

  • Lockout physically prevents operation ≠ Tagout only warns, no lock

Series ≠ Parallel Voltage

  • Series divides voltage across loads ≠ Parallel keeps voltage equal always

Hydraulics ≠ Pneumatics

  • Hydraulics uses incompressible liquid power ≠ Pneumatics uses compressible air power

Relay ≠ Contactor

  • Relay switches low-current control signals ≠ Contactor switches high-current power loads

Open ≠ Short Circuit

  • Open circuit stops all current ≠ Short circuit causes excess current

AND ≠ OR Gate

  • AND needs every input high ≠ OR needs just one input

Superheat ≠ Subcooling

  • Superheat measures the vapor side ≠ Subcooling measures the liquid side

Last Minute

  • 1. V = I × R
  • 2. Series: one path, divided voltage
  • 3. Parallel: many paths, equal voltage
  • 4. AND needs all inputs high
  • 5. LOTO: isolate, lock, then verify
  • 6. Hydraulics = liquid; pneumatics = air
  • 7. Passing score = 70 minimum
  • 8. Part 1 home; Part 2 proctored
  • 9. Compressor raises pressure and temperature
  • 10. PPE must match the hazard
  • 11. Exam fee = $0 always
  • 12. Eligibility register lasts about 2 years

USPS Postal Exam 955 (Technical Maintenance)

  • Practice Questions 162 questions Study Guide 37 topics Cheat Sheet 106 facts Flashcards 50 cards Shorts 3 short s Podcast