Cheat sheet
Wastewater Collection Operator Cheat Sheet
System Components
- 30% of exam
- Gravity Sewers Manholes Force Mains System Maps Pipe Defects
Maintenance + Rehab
- 25% of exam
- Cleaning Tools CCTV I/I FOG Rehab Picker
Pump Stations
- 20% of exam
- Wet Wells Pump Alarms Force Main SCADA Station Picker
Safety + Compliance
- 15% of exam
- Confined Space LOTO SSO CMOM Emergency Sequence
Math + Hydraulics
- 10% of exam
- Flow Units Velocity Volume Head Math Picker
Quick Facts
- Exam Collection Operator
- Body WPI/state authority
- Questions 100 scored
- Pretest Up to 10
- Time 3 hours
- Pass 70%
- Math About 10%
- Credential Jurisdiction issued
Gravity vs Force Main SY
Gravity
- Slope driven
- Partly full
- Manhole access
Force main
- Pump driven
- Pressurized pipe
- Valve access
- Slope or pump decides
Gravity Sewers SY
- Gravity main Downhill conveyance
- Lateral Building connection
- Interceptor Large collector
- Invert Pipe flowline
- Slope Drives velocity
- Sag Unwanted low spot
- Surcharge Pipe under pressure
Manhole vs Cleanout SY
Manhole
- Main access
- Worker entry
- Junction structure
Cleanout
- Small access
- Tool entry
- Usually lateral
- Access size matters
Structures + Access SY
- Manhole Main access
- Cleanout Lateral access
- Drop manhole Controls elevation
- Channel Directs flow
- Bench Side platform
- Frame Supports cover
- Cover seal Blocks inflow
Pipe Defects SY
- Offset joint Misaligned pipe
- Crack Structural opening
- Fracture Broken wall
- Roots Joint intrusion
- Grease FOG deposit
- Debris Blockage material
- Crown corrosion H2S damage
I/I Clues MA
- Fast peaks inflow; slow peaks infiltration.
- Fast Inflow Slow Infiltration
Infiltration vs Inflow MA
Infiltration
- Groundwater entry
- Defects/joints
- Delayed wet response
Inflow
- Surface water entry
- Direct connections
- Fast rain response
- Groundwater seeps; stormwater connects
Field Problem Picker MA
- Standing CCTV water → Grade repair ( Sag )
- Roots at joints → Cut and repair ( Defect )
- Restaurant stoppages → FOG control ( Grease )
- Rainfall peak flow → I/I study ( Wet weather )
- Smoke exits roof → Illegal inflow ( Direct )
- Joint seepage → Grouting ( Infiltration )
- Long cracked reach → CIPP ( Lining )
- Collapsed segment → Excavate repair ( Structural )
Cleaning Tools MA
- Jetting High-pressure water
- Rodding Mechanical cutting
- Bucket machine Heavy debris
- Pigging Force-main cleaning
- Vac truck Remove solids
- Root saw Cut roots
- Flushing Move deposits
CCTV vs Smoke Test MA
CCTV
- Inside view
- Pipe defects
- Condition coding
Smoke test
- Surface clues
- Inflow sources
- Illegal openings
- Camera sees; smoke reveals
Inspection Tests MA
- CCTV Visual defects
- Smoke test Find inflow
- Dye test Trace connection
- Flow monitor Track peaks
- Lamp test Alignment check
- Manhole survey Surface defects
- Acoustic scan Screen blockages
Rehab Methods MA
- Point repair Fix short defect
- CIPP Lined pipe
- Sliplining Smaller inserted pipe
- Pipe bursting Replace in place
- Grouting Seal joints
- Manhole lining Protect structure
- Root control Slow regrowth
Pump Troubleshooting PU
- Power, controls, pump, valves, force main.
- Power Controls Pump Valves Main
Lead vs Lag Pump PU
Lead
- Starts first
- Normal flow
- Alternates duty
Lag
- Starts second
- Peak flow
- Backup capacity
- Level demand adds pumps
Station Alarm Picker PU
- High wet well → Restore pumping ( Prevent SSO )
- Power failure → Generator ( Backup )
- Pump short cycles → Check controls ( Levels )
- Pump hums only → Check impeller ( Clog )
- Reverse flow → Check valve ( Backflow )
- No SCADA signal → Local inspection ( Verify )
- Airlocked pump → Vent/prime ( Air )
- Force-main break → Bypass/isolate ( Contain )
Lift Station PU
- Wet well Stores influent
- Submersible pump Common wastewater pump
- Dry well Equipment room
- Lead pump Starts first
- Lag pump Adds capacity
- Float switch Level control
- Transducer Continuous level
Force Main PU
- Force main Pressurized discharge
- Check valve Stops backflow
- Plug valve Isolates flow
- Air release Vents gas
- Surge Pressure transient
- Bypass pump Temporary pumping
- Valve vault Access valves
SSO Sequence SA
- Safe, stop, contain, recover, report.
- Safe Stop Contain Recover Report
SSO vs Backup SA
SSO
- System release
- Public/environment risk
- Reportable event
Backup
- Building impact
- Private property
- Cause investigation
- Location changes response
Safety Response Picker SA
- Manhole entry → Test atmosphere ( Before entry )
- Bad atmosphere → Ventilate ( No entry )
- Servicing pump → LOTO ( Zero energy )
- Open roadway → Traffic control ( MUTCD )
- Overflow starts → Protect public ( First )
- Flow nears drain → Contain flow ( Block path )
- Chemical spill → Isolate area ( Escalate )
- Entrant collapses → Non-entry rescue ( Do not enter )
Safety Thresholds SA
- O2 low Below 19.5%
- O2 high Above 23.5%
- LEL hazard Above 10%
- H2S Toxic sewer gas
- Methane Flammable gas
- CO Toxic combustion gas
- Ventilation Fresh-air control
Confined Space Order SA
- Test, ventilate, enter only when authorized.
- Test Ventilate Permit Monitor
Compliance Response SA
- SSO Untreated release
- NPDES Discharge permit
- CMOM Capacity management
- FOG Grease program
- Work order Maintenance record
- Chain-of-command Notification path
- Public notice Required warning
Math Formulas MA
- Area 0.785 x D2
- Flow Area x velocity
- Velocity Flow / area
- Volume Area x depth
- Detention Volume / flow
- Head Pressure x 2.31
- MGD Million gal/day
Common Traps
Treatment vs Collection
- Convey wastewater ≠ Treat wastewater
Smell vs Meter
- Meter proves safety ≠ Odor proves safety
Report vs Respond
- Control source first ≠ Paperwork first
Switch vs LOTO
- Verify zero energy ≠ Turn switch off
Sag vs Siphon
- Unwanted belly ≠ Designed crossing
Pass vs Certification
- Authority certifies ≠ Exam pass certifies
Last Minute
- 1. Gravity needs slope
- 2. Force mains need pumps
- 3. Manholes are access points
- 4. Infiltration = groundwater entry
- 5. Inflow = direct stormwater
- 6. Test atmosphere before entry
- 7. LOTO before pump service
- 8. High wet well prevents SSO
- 9. CCTV finds pipe defects
- 10. Q = area x velocity
Wastewater Collection System Operator
- Practice Questions 100 questions Study Guide 24 topics Cheat Sheet 77 facts Flashcards 50 cards Shorts 3 short s Videos 1 video Blogs 1 blog 1 Job Wiki Free CE Podcast