Cheat sheet

Wastewater Collection Operator Cheat Sheet

Practice this exam

System Components

  • 30% of exam
  • Gravity Sewers Manholes Force Mains System Maps Pipe Defects

Maintenance + Rehab

  • 25% of exam
  • Cleaning Tools CCTV I/I FOG Rehab Picker

Pump Stations

  • 20% of exam
  • Wet Wells Pump Alarms Force Main SCADA Station Picker

Safety + Compliance

  • 15% of exam
  • Confined Space LOTO SSO CMOM Emergency Sequence

Math + Hydraulics

  • 10% of exam
  • Flow Units Velocity Volume Head Math Picker

Quick Facts

  • Exam Collection Operator
  • Body WPI/state authority
  • Questions 100 scored
  • Pretest Up to 10
  • Time 3 hours
  • Pass 70%
  • Math About 10%
  • Credential Jurisdiction issued

Gravity vs Force Main SY

Gravity

  • Slope driven
  • Partly full
  • Manhole access

Force main

  • Pump driven
  • Pressurized pipe
  • Valve access
  • Slope or pump decides

Gravity Sewers SY

  • Gravity main Downhill conveyance
  • Lateral Building connection
  • Interceptor Large collector
  • Invert Pipe flowline
  • Slope Drives velocity
  • Sag Unwanted low spot
  • Surcharge Pipe under pressure

Manhole vs Cleanout SY

Manhole

  • Main access
  • Worker entry
  • Junction structure

Cleanout

  • Small access
  • Tool entry
  • Usually lateral
  • Access size matters

Structures + Access SY

  • Manhole Main access
  • Cleanout Lateral access
  • Drop manhole Controls elevation
  • Channel Directs flow
  • Bench Side platform
  • Frame Supports cover
  • Cover seal Blocks inflow

Pipe Defects SY

  • Offset joint Misaligned pipe
  • Crack Structural opening
  • Fracture Broken wall
  • Roots Joint intrusion
  • Grease FOG deposit
  • Debris Blockage material
  • Crown corrosion H2S damage

I/I Clues MA

  • Fast peaks inflow; slow peaks infiltration.
  • Fast Inflow Slow Infiltration

Infiltration vs Inflow MA

Infiltration

  • Groundwater entry
  • Defects/joints
  • Delayed wet response

Inflow

  • Surface water entry
  • Direct connections
  • Fast rain response
  • Groundwater seeps; stormwater connects

Field Problem Picker MA

  • Standing CCTV water → Grade repair ( Sag )
  • Roots at joints → Cut and repair ( Defect )
  • Restaurant stoppages → FOG control ( Grease )
  • Rainfall peak flow → I/I study ( Wet weather )
  • Smoke exits roof → Illegal inflow ( Direct )
  • Joint seepage → Grouting ( Infiltration )
  • Long cracked reach → CIPP ( Lining )
  • Collapsed segment → Excavate repair ( Structural )

Cleaning Tools MA

  • Jetting High-pressure water
  • Rodding Mechanical cutting
  • Bucket machine Heavy debris
  • Pigging Force-main cleaning
  • Vac truck Remove solids
  • Root saw Cut roots
  • Flushing Move deposits

CCTV vs Smoke Test MA

CCTV

  • Inside view
  • Pipe defects
  • Condition coding

Smoke test

  • Surface clues
  • Inflow sources
  • Illegal openings
  • Camera sees; smoke reveals

Inspection Tests MA

  • CCTV Visual defects
  • Smoke test Find inflow
  • Dye test Trace connection
  • Flow monitor Track peaks
  • Lamp test Alignment check
  • Manhole survey Surface defects
  • Acoustic scan Screen blockages

Rehab Methods MA

  • Point repair Fix short defect
  • CIPP Lined pipe
  • Sliplining Smaller inserted pipe
  • Pipe bursting Replace in place
  • Grouting Seal joints
  • Manhole lining Protect structure
  • Root control Slow regrowth

Pump Troubleshooting PU

  • Power, controls, pump, valves, force main.
  • Power Controls Pump Valves Main

Lead vs Lag Pump PU

Lead

  • Starts first
  • Normal flow
  • Alternates duty

Lag

  • Starts second
  • Peak flow
  • Backup capacity
  • Level demand adds pumps

Station Alarm Picker PU

  • High wet well → Restore pumping ( Prevent SSO )
  • Power failure → Generator ( Backup )
  • Pump short cycles → Check controls ( Levels )
  • Pump hums only → Check impeller ( Clog )
  • Reverse flow → Check valve ( Backflow )
  • No SCADA signal → Local inspection ( Verify )
  • Airlocked pump → Vent/prime ( Air )
  • Force-main break → Bypass/isolate ( Contain )

Lift Station PU

  • Wet well Stores influent
  • Submersible pump Common wastewater pump
  • Dry well Equipment room
  • Lead pump Starts first
  • Lag pump Adds capacity
  • Float switch Level control
  • Transducer Continuous level

Force Main PU

  • Force main Pressurized discharge
  • Check valve Stops backflow
  • Plug valve Isolates flow
  • Air release Vents gas
  • Surge Pressure transient
  • Bypass pump Temporary pumping
  • Valve vault Access valves

SSO Sequence SA

  • Safe, stop, contain, recover, report.
  • Safe Stop Contain Recover Report

SSO vs Backup SA

SSO

  • System release
  • Public/environment risk
  • Reportable event

Backup

  • Building impact
  • Private property
  • Cause investigation
  • Location changes response

Safety Response Picker SA

  • Manhole entry → Test atmosphere ( Before entry )
  • Bad atmosphere → Ventilate ( No entry )
  • Servicing pump → LOTO ( Zero energy )
  • Open roadway → Traffic control ( MUTCD )
  • Overflow starts → Protect public ( First )
  • Flow nears drain → Contain flow ( Block path )
  • Chemical spill → Isolate area ( Escalate )
  • Entrant collapses → Non-entry rescue ( Do not enter )

Safety Thresholds SA

  • O2 low Below 19.5%
  • O2 high Above 23.5%
  • LEL hazard Above 10%
  • H2S Toxic sewer gas
  • Methane Flammable gas
  • CO Toxic combustion gas
  • Ventilation Fresh-air control

Confined Space Order SA

  • Test, ventilate, enter only when authorized.
  • Test Ventilate Permit Monitor

Compliance Response SA

  • SSO Untreated release
  • NPDES Discharge permit
  • CMOM Capacity management
  • FOG Grease program
  • Work order Maintenance record
  • Chain-of-command Notification path
  • Public notice Required warning

Math Formulas MA

  • Area 0.785 x D2
  • Flow Area x velocity
  • Velocity Flow / area
  • Volume Area x depth
  • Detention Volume / flow
  • Head Pressure x 2.31
  • MGD Million gal/day

Common Traps

Treatment vs Collection

  • Convey wastewater ≠ Treat wastewater

Smell vs Meter

  • Meter proves safety ≠ Odor proves safety

Report vs Respond

  • Control source first ≠ Paperwork first

Switch vs LOTO

  • Verify zero energy ≠ Turn switch off

Sag vs Siphon

  • Unwanted belly ≠ Designed crossing

Pass vs Certification

  • Authority certifies ≠ Exam pass certifies

Last Minute

  • 1. Gravity needs slope
  • 2. Force mains need pumps
  • 3. Manholes are access points
  • 4. Infiltration = groundwater entry
  • 5. Inflow = direct stormwater
  • 6. Test atmosphere before entry
  • 7. LOTO before pump service
  • 8. High wet well prevents SSO
  • 9. CCTV finds pipe defects
  • 10. Q = area x velocity

Wastewater Collection System Operator