Cheat sheet
SACPCMP CHS Officer Cheat Sheet
Registration, Ethics & Scope
- Not published of exam
- SACPCMP Exam Route 2026/27 CHSO Fees CHSO Stages of Services Examination Score Outcomes
Health & Safety Legislative Framework
- Not published of exam
- OHS Act Section Map Construction Regulation Map Permit and Notification Triggers COIDA After January 2026
H&S Plans, Files & Documents
- Not published of exam
- Health & Safety File Contents Written Appointments On Site Who To Appoint Specification vs Plan
Hazard Identification & Risk Management
- Not published of exam
- Regulation 9 Risk Assessment Control Hierarchy & Training Baseline vs Site Assessment Review Triggers
Construction Site Operations
- Not published of exam
- Site Dimension Rules Plant, Power & Platforms Height Work Picker Prevention vs Arrest
Inspections, Audits & Performance
- Not published of exam
- Compliance Intervals 30-day audit cycle Stop-work powers Trend analysis duty
Incident Investigation & Emergency
- Not published of exam
- Incident Reporting Forms What To Report, When Section 24 vs COIDA 39 Scene preservation
Occupational Hygiene, Health & Welfare
- Not published of exam
- Health, Noise & Welfare Limits Noise Limit vs Action Level First aid ratios Confined space numbers
Quick Facts
- Council SACPCMP (Act 48 of 2000)
- Category Construction Health & Safety Officer
- Assessment Online proctored Council examination
- Pass mark 60%
- Items and time Not published
- Examination fee R711.07 for 2026/27
- Qualification NQF 5, 120 credits
- Experience Four years relevant practice
- Re-write band 35-59%, within six months
- Below 35% Archived, must re-apply
Examination Score Bands RE
- 60 passes, 35 to 59 re-writes
- 60% and above passes 35-59% may re-write Below 35% archived Re-write within six months
CHSO vs CHSM RE
CHSO
- NQF 5, 120 credits
- Four years experience
- Exam fee R711.07
CHSM
- NQF 6, 240 credits
- Five years experience
- Exam fee R1 495.59
- Officer is site level
Examination Score Outcomes RE
- Scored 60% or above → Proceed to next phase ( Registration continues )
- Scored 55% to 59% → Moderation may apply ( Non-MCQ papers only )
- Scored 35% to 59% → Pay fee, then re-write ( Conclude within six months )
- Scored below 35% → Application is archived ( Re-apply from the start )
- Absent, no five-day notice → Fees are forfeited ( Certified illness may refund )
- No booking in 12 months → Application may be cancelled ( Start a new application )
SACPCMP Exam Route RE
- Eligibility Assessed before exam invite
- Booking window Three months from eligibility
- Booking cut-off Five working days prior
- Unbooked 12 months Application may be cancelled
- Invigilation Virtual proctor, online
- Identity check Original ID or passport
- Room rule Alone, no dual monitors
- Mock exam Required before live sitting
- Moderation Non-MCQ fails within 5%
- Points and timing Set in advance per paper
Exam vs Interview RE
Examination
- CHSO and CHSM
- Online proctored paper
- Pass mark 60%
Interview
- PrCHSA and mentor
- Interview fee payable
- Three attempts allowed
- Fee schedule tells you
2026/27 CHSO Fees RE
- Application R413.81
- Examination R711.07 per attempt
- Registration R362.35
- Annual fee R3 987.59
- Interview fee None for CHSO
- Re-write Re-examination fee payable
- Annual invoice Issued each December
- Late annual fee 10% penalty after 120 days
- Non-payment Registration may be cancelled
CHSO Stages of Services RE
- Stages 1 to 3 Not applicable to CHSO
- Stage 4 Tender documentation and procurement
- Stage 5 Construction documentation and management
- Stage 6 Project close out
- Task 4.1 Attend tender clarification meetings
- Task 5.1 Assist preparing the plan
- Task 5.10 Compile emergency response plans
- Task 5.17 Trend analysis of deficiencies
- Task 6.3 Consolidated file for client
- Gazette CBE Notice 1181 of 2019
Three Permit Triggers LE
- 180 days, 1 800 person days, R13 million
- Exceeds 180 days Over 1 800 person days R13 million contract Or CIDB level 6
Permit vs Notification LE
Permit, Reg 3
- Client applies
- 30 days ahead
- Agent appointment mandatory
Notify, Reg 4
- Contractor notifies
- Seven days ahead
- Agent is optional
- Permit brings a site number
Permit, Notify Or Neither LE
- Work exceeds 180 days → Client applies for permit ( 30 days ahead )
- Over 1 800 person days → Client applies for permit ( Regulation 3(1)(b) )
- Value over R13 million → Client applies for permit ( Or CIDB level 6 )
- Excavation, no permit trigger → Contractor notifies director ( Seven days ahead )
- Fall risk work only → Contractor notifies director ( Seven days ahead )
- Demolition or explosives → Contractor notifies director ( Seven days ahead )
- Owner-occupied single dwelling → Notify only, seven days ( Regs 3 and 5 excluded )
- None of these apply → No permit or notice ( Other duties still apply )
OHS Act Section Map LE
- Section 8 Employer duty to employees
- Section 9 Duty to non-employees
- Section 13 Duty to inform employees
- Section 14 General duties of employees
- Section 15 No interference or misuse
- Section 16(2) CEO assigns, keeps liability
- Section 17 Designate H&S representatives
- Section 19 Establish H&S committee
- Section 20 Committee functions and records
- Section 23 No deductions for safety
- Section 24 Report certain incidents
- Section 26 Victimisation forbidden
- Section 37 Mandatary written agreement
- Section 38 Offences and penalties
- Section 44 Incorporates safety standards
Representative vs Committee LE
H&S representative
- Over 20 employees
- One per 50
- Designated in writing
H&S committee
- Two or more representatives
- Meets every three months
- Reviews incident records
- Reps trigger the committee
Construction Regulation Map LE
- Reg 3 Construction work permit
- Reg 4 Notification of construction work
- Reg 5 Duties of client
- Reg 6 Duties of designer
- Reg 7 Principal contractor and contractor
- Reg 8 Management and supervision
- Reg 9 Risk assessment
- Reg 10 Fall protection
- Reg 11 Structures
- Reg 12 Temporary works
- Reg 13 Excavation
- Reg 14 Demolition work
- Reg 16 Scaffolding
- Reg 17 Suspended platforms
- Reg 24 Electrical installations and machinery
- Reg 26 Water environments
- Reg 29 Fire precautions
- Reg 30 Employees' facilities
Permit and Notification Triggers LE
- Permit: duration Exceeds 180 days
- Permit: person days More than 1 800
- Permit: value R13 million or CIDB 6
- Permit: lead time Apply 30 days before
- Permit issued Within 30 days
- Site specific number Displayed at main entrance
- Number transfer Not transferrable
- Notify: excavation Seven days before start
- Notify: fall risk Seven days before start
- Notify: demolition Seven days before start
- Notify: explosives Seven days before start
- Own single-storey dwelling Regs 3 and 5 excluded
COIDA After January 2026 LE
- Commencement 23 January 2026 proclamation
- Prescription Three years, was 12 months
- Section 39(1) Report within seven days
- Late report penalty 10% of annual earnings
- Section 35 Bars civil claim on employer
- Good standing Required before work starts
- Enforcement shift Administrative penalties, not prosecution
- Section 97 regulations Published 6 March 2026
Document Chain SY
- Baseline, Specification, Plan, File, Handover
- Client baseline assessment Client H&S specification Contractor H&S plan Site H&S file Consolidated handover file
Specification vs Plan SY
Specification
- Client writes it
- From the baseline
- Goes into tender
H&S plan
- Principal contractor writes
- Based on the specification
- Client finally approves
- Client sets, contractor delivers
Who To Appoint SY
- Managing the whole site → Construction manager ( Regulation 8(1) )
- Assisting safety control → Health and safety officer ( Regulation 8(5) )
- Running risk assessments → Competent risk assessor ( Regulation 9(1) )
- Erecting formwork → Temporary works designer ( Regulation 12(1) )
- Digging excavations → Excavation supervisor ( Regulation 13(1) )
- Erecting access scaffold → Scaffold supervisor ( Regulation 16(1) )
- Client needs a permit → Competent agent, mandatory ( Regulation 5(5) )
- Only notification needed → Agent is optional ( Regulation 5(6) )
Health & Safety File Contents SY
- Client specification Site specific, from baseline
- H&S plan Client finally approves
- Risk assessments Regulation 9, kept on site
- Appointment letters All written designations
- Medical certificates Annexure 3 fitness
- Induction records Kept on site
- Good standing letter COIDA registration proof
- Incident register Annexure 1 records
- Permit copy Kept in the file
- Inspection registers Excavation, scaffold, electrical
- Contractor list Updated, with agreements
- Handover file Consolidated at completion
Written Appointments On Site SY
- Construction manager Regulation 8(1), full-time
- Assistant managers Regulation 8(2), by size
- Health and safety officer Regulation 8(5), after consultation
- Construction supervisor Regulation 8(7), in writing
- Risk assessor Regulation 9(1), competent
- Fall protection planner Regulation 10(1), designated
- Temporary works designer Regulation 12(1), approves erection
- Excavation supervisor Regulation 13(1), competent
- Demolition supervisor Regulation 14(1), competent
- Scaffold supervisor Regulation 16(1), competent
- Stacking supervisor Regulation 28, competent
- Client agent Regulation 5(5), when permit
Regulation 9 Five Elements RI
- Identify, Analyse, Plan, Monitor, Review
- Identify hazards and risks Analyse and evaluate Plan safe procedures Monitoring plan Review plan
Baseline vs Site Assessment RI
Baseline
- Client duty
- Before procurement
- Drives the specification
Regulation 9
- Contractor duty
- Before and during work
- Part of the plan
- Whose duty, which stage
Regulation 9 Risk Assessment RI
- Element 1 Identify hazards and risks
- Element 2 Analyse and evaluate, documented
- Element 3 Plan with safe procedures
- Element 4 Monitoring plan
- Element 5 Review plan
- Timing Before and during work
- Ergonomics Regulation 9(2), must address
- Consultation H&S committee or union
- Copies Available on site
- Review trigger Risk profile change, incident
Control Hierarchy & Training RI
- First step Eliminate or mitigate hazard
- Last resort Personal protective equipment
- Statutory basis OHS Act section 8(2)(b)
- Cost of PPE No employee deduction
- Deduction exception Intentional loss or damage
- Training timing Before work commences
- Retraining Per monitoring and review plan
- Contractor briefing Principal contractor informs contractors
- Baseline owner Client, before procurement
Excavation Inspection Triggers SI
- Daily, Blast, Ground fall, Damage, Rain
- Daily before each shift After every blast After a ground fall After support damage After rain
Prevention vs Arrest SI
Fall prevention
- Stops the fall
- Guard rails, barriers
- The default requirement
Fall arrest
- Limits the consequences
- Harness and anchor
- Only if impracticable
- Arrest is the fallback
Height Work Picker SI
- Any fall risk position → Fall protection plan ( Regulation 10(1) )
- Opening in floor or slab → Guard, fence or barricade ( Regulation 10(4)(a) )
- Prevention is practicable → Use fall prevention ( The default choice )
- Prevention not practicable → Use fall arrest ( Plus a rescue plan )
- Roof pitch or surface unsafe → Roof ladders or crawl-boards ( General Safety Regulations )
- Working from a ladder → Secure it, sheath tools ( Maximum 9 m )
- Platform above two metres → Guard rails and toe-boards ( 900 to 1 000 mm )
- Person could fall in water → Lifejacket plus rescue means ( Regulation 26 )
Site Dimension Rules SI
- Excavation access Within six metres
- Public barrier At least one metre
- Night marking Warning illuminants required
- Guard rails 900 to 1 000 mm
- Toe-boards At least 150 mm
- Timber toe-boards At least 25 mm
- Leaning ladder limit Maximum 9 m
- Fixed ladder cage Over 5 m at 75°
- Ladder projection 900 mm above platform
- Platform to structure Not more than 75 mm
- Seated work gap Up to 300 mm
- Trestle scaffold limit 3 m, two tiers
- Wooden scaffold limit Maximum 10 m high
- Tunnel entry ban Below 800 mm height
Plant, Power & Platforms SI
- Temporary installations Weekly competent inspection
- Electrical machinery Daily operator checklist
- Buried services Locate before excavating
- Tower crane wind Audible over-speed warning
- Crane operator Annexure 3 medical certificate
- Concrete casting Written authorisation first
- Formwork strike Written authorisation to remove
- Suspended platform design Engineer system design certificate
- Outrigger safety factor At least four
- Suspension rope factor At least ten
- Scaffold safety factor At least two
- Fall arrest use Only when prevention impracticable
- Roof work weather No work in inclement
- Lifejacket rule Where drowning risk exists
Compliance Intervals AU
- Client audit At least every 30 days
- Audit report To principal contractor, seven days
- Principal contractor audit At least every 30 days
- Excavation inspection Daily before each shift
- Scaffold inspection Weekly and after bad weather
- Temporary works Daily until removed
- Structure inspection Six-monthly for two years, yearly
- Suspended platform test Every 12 months, 110%
- Rope examination Every three months in use
- H&S committee At least every three months
- Noise risk assessment Every 24 months
- Noise monitoring Every 24 months
Section 24 vs COIDA 39 IN
Section 24
- To the provincial director
- WCL1 or WCL2
- Safety enforcement
COIDA 39
- To the Commissioner
- Within seven days
- Compensation claim
- Both can apply together
What To Report, When IN
- Worker dies on site → Phone provincial director now ( Then WCL1 within seven days )
- Limb lost or amputated → Phone, then written notice ( Section 24(1)(a) )
- Unable to work 14 days → WCL1 or WCL2 notice ( Within seven days )
- Treatment beyond first aid → Record in Annexure 1 ( No director notice )
- Non-employee injured → Notify provincial director forthwith ( GAR 8(3) )
- Employee injured at work → Report to the Commissioner ( COIDA, seven days )
- Occupational disease found → Practitioner tells chief inspector ( Within 14 days )
Incident Reporting Forms IN
- Section 24 trigger Death, unconsciousness, limb loss
- 14-day rule Unable to work 14 days
- Immediate report Forthwith by telephone or fax
- Written notice WCL1 or WCL2, seven days
- Death after notice Notify director forthwith
- Non-employee injury Notify provincial director forthwith
- Incident record Annexure 1, three years
- Also recorded Treatment beyond first aid
- Investigation start Within seven days
- Findings entry Into Annexure 1 immediately
- Committee review At its next meeting
- Scene preservation Inspector consent to disturb
- Allowed anyway Rescue, remove casualties, prevent recurrence
- Disease notice Practitioner, within 14 days
- Fatality on site Client ensures the report
Confined Space Numbers HY
- Oxygen 20%, LEL 25% or 10%
- Oxygen below 20% controls 25% LEL, no ignition 10% LEL, other work Attendant trained in resuscitation
Noise Limit vs Action Level HY
Noise-rating limit
- 85 dBA rating level
- 137 dBC peak
- Noise zone applies
Noise action level
- 82 dBA rating level
- Needs ototoxic co-exposure
- Or whole-body vibration
- Co-exposure lowers the trigger
Health, Noise & Welfare Limits HY
- First aid box More than five employees
- First aider trigger More than 10 employees
- First aider ratio One per 50 employees
- Shops and offices One per 100 employees
- Noise-rating limit 85 dBA, 137 dBC peak
- Noise action level 82 dBA with co-exposure
- Noise zone Demarcate, hearing protection compulsory
- Noise records Kept for 40 years
- NIHL Regulations repeal 6 September 2026
- Showers One per 15 persons
- Sanitary facilities One per 30, each sex
- Changing rooms Provided for each sex
- Eating areas Sheltered, clean, maintained
- Confined space oxygen Below 20% needs controls
- LEL, no ignition source Below 25% of LEL
- LEL, other work Below 10% of LEL
- Confined space attendant Trained in resuscitation, outside
Common Traps
Exam, not interview
- CHSO writes a Council exam ≠ PrCHSA sits an interview
Item count is unpublished
- SACPCMP publishes no item count ≠ Third-party counts are invented
First aider ratio splits
- Construction: one per 50 ≠ Shops and offices: one per 100
Permit is not notification
- Permit: client, 30 days ≠ Notify: contractor, seven days
Two reports, two laws
- Section 24 to the director ≠ COIDA 39 to the Commissioner
No SANS number in regs
- Regulation 16(2) points to standards ≠ Section 44 incorporates them
Prescription changed in 2026
- Now three years from accident ≠ Twelve months is outdated
Limit is not action level
- 85 dBA is the limit ≠ 82 dBA needs co-exposure
Weights are not published
- No SACPCMP exam blueprint exists ≠ Annexure B lists knowledge areas
Last Minute
- 1. Pass is 60%; below 35% archives
- 2. 35-59% re-writes within six months
- 3. Exam fee R711.07 for 2026/27
- 4. Item count and time: not published
- 5. CHSO needs NQF 5, four years
- 6. Reg 8(5) appoints the CHSO
- 7. Permit 30 days; notify seven days
- 8. Client audits every 30 days
- 9. Audit report to PC: seven days
- 10. Excavations inspected daily before shift
- 11. Scaffold inspected weekly, after weather
- 12. Annexure 1 records kept three years
- 13. Investigate incidents within seven days
- 14. One first aider per 50 workers
- 15. 85 dBA limit; 82 dBA action
- 16. Fall arrest only if prevention impracticable
- 17. Committee meets every three months
SACPCMP Construction Health & Safety Officer Examination (South Africa)
- Practice Questions 172 questions Study Guide 57 topics Cheat Sheet 197 facts Flashcards 50 cards
Same family resources
- Explore More South Africa SACPCMP Health & Safety
- Continue into nearby exams from the same family. Each card keeps practice questions, study guides, flashcards, videos, and articles in one place.
SACPCMP Construction Health & Safety Manager Examination (South Africa)
- Practice Questions 100 questions Study Guide 49 topics Shorts 3 short s
SACPCMP Construction Health & Safety Agent (Pr.CHSA) Examination (South Africa)
- Practice Questions 100 questions