A gravity caisson quay wall has a total effective vertical dead weight plus soil backfill load of ΣN = 1800 kN per meter run. The total horizontal active earth pressure plus residual water thrust is ΣP = 600 kN/m. The friction coefficient between the concrete caisson base and the crushed-rock foundation bed is μ = 0.45. Calculate the factor of safety against basal sliding (Kc = μ · ΣN / ΣP) and evaluate if it satisfies the minimum allowable safety factor [Kc] = 1.30 per JTS 167-2018.