Study guide
1.3 Comminutors, Macerators & Velocity-Controlled Grit Channels
ABC/WPI Wastewater Treatment Operator Class I Certification Exam Exam
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: Introduction, Plant Overview & Preliminary Screening
1.1 Exam Structure, Plant Layout & Unit Process Flow 1.2 Bar Screens, Trash Racks & Mechanically Cleaned Screens 1.3 Comminutors, Macerators & Velocity-Controlled Grit Channels
2 Chapter 2: Grit Removal, Flow Equalization & Primary Clarification
2.1 Aerated Grit Chambers, Vortex Separators & Grit Handling 2.2 Primary Sedimentation Principles & Design Parameters 2.3 Primary Clarifier Operation, Sludge Pumping & Troubleshooting
3 Chapter 3: Secondary Biological Treatment — Activated Sludge Fundamentals
3.1 Activated Sludge Biochemistry & Aeration Tank Mechanics 3.2 Process Control Parameters: F/M Ratio, MCRT & Sludge Wasting 3.3 Settleability Testing, Sludge Volume Index & Clarifier Blanket Dynamics 3.4 Activated Sludge Troubleshooting & Microscopic Bioindicators
4 Chapter 4: Alternative Biological Processes & Fixed-Film Systems
4.1 Extended Aeration Package Plants, Oxidation Ditches & SBR Cycles 4.2 Fixed-Film Systems: Trickling Filters & Rotating Biological Contactors (RBCs) 4.3 Waste Stabilization Ponds, Facultative Lagoons & Aerated Ponds
5 Chapter 5: Disinfection Systems & Effluent Management
5.1 Chlorination Chemistry, Feed Equipment & Chlorine Contact Basins 5.2 Dechlorination Systems, Sulfur Dioxide & Bisulfite Chemistry 5.3 Ultraviolet (UV) Disinfection Mechanics, Dosage & Effluent Standards
6 Chapter 6: Solids Handling, Digestion & Biosolids Management
6.1 Sludge Thickening: Gravity, DAF & Gravity Belt Thickeners 6.2 Aerobic & Anaerobic Digestion Principles & Operational Control 6.3 Dewatering Technologies: Belt Filter Presses, Centrifuges & Drying Beds 6.4 Biosolids Regulations, EPA 40 CFR Part 503 & Land Application
7 Chapter 7: Sampling Protocols, Laboratory Testing & Operator Math
7.1 Wastewater Sampling Methods, Representative Samples & Chain of Custody 7.2 Biochemical Oxygen Demand (BOD5/CBOD5) & Total Suspended Solids (TSS) Analysis 7.3 Routine Process Testing: Dissolved Oxygen, pH, Settleable Solids & Ammonia 7.4 Essential Operator Math: Flow Conversions, Detention Time, Loading Rates & Pounds Formula
8 Chapter 8: Safety, Collection Systems, Utility Operations & Regulations
8.1 Confined Space Entry, Atmospheric Testing & Hazardous Gas Safety 8.2 Chemical Safety: Chlorine Gas Cylinders, Hypochlorite & Hazard Communication 8.3 Collection Systems, Lift Stations, Inflow/Infiltration & Clean Water Act / NPDES Compliance
9 Chapter 9: Pumps, Motors, Drives & Plant Electrical Systems
9.1 Centrifugal Pumps: Types, Curves, Cavitation & Seal Maintenance 9.2 Positive Displacement Pumps: Progressive Cavity, Plunger, Diaphragm & Peristaltic 9.3 Motors, Motor Control Centers, Variable Frequency Drives & Electrical Safety
10 Chapter 10: Aeration, Mixing & Chemical Feed Equipment
10.1 Aeration Equipment: Blowers, Diffusers, Surface Aerators & Air Distribution 10.2 Mixers, Flash Mixing & Chemical Feed Systems
11 Chapter 11: Instrumentation, Online Analyzers, SCADA & Auxiliary Power
11.1 Field Instrumentation: Flow Measurement, Level Sensing & Pressure 11.2 Online Process Analyzers: Dissolved Oxygen, pH, ORP, Turbidity & Chlorine Residual 11.3 SCADA, Telemetry, Alarm Management, Security & Auxiliary Power
12 Chapter 12: Valves, Piping, Compressors & Ancillary Plant Equipment
12.1 Valves, Piping, Air Compressors, Conveyors, Hoists & Cranes
13 Chapter 13: Tertiary Filtration & Effluent Polishing
13.1 Tertiary Filtration Equipment: Granular Media, Disc & Cloth Filters 13.2 Filtration Process Control: Loading Rates, Headloss, Breakthrough & Backwash Triggers
14 Chapter 14: Activated Sludge Configurations & Biological Nutrient Removal
14.1 Activated Sludge Configurations: Conventional Plug Flow, Complete Mix, Step Feed & Contact Stabilization 14.2 Nutrient Removal: Nitrification, Denitrification & Anaerobic/Anoxic/Aerobic Zones
15 Chapter 15: Chemical Dosing Processes, Effluent Disposal & Solids Disposal
15.1 Chemical Dosing Processes: Coagulation, Flocculation, pH Adjustment & Dosage Calculations 15.2 Effluent Disposal: Surface Water Discharge & Rapid Infiltration Basins; Solids Disposal to Landfill
16 Chapter 16: Bacteriological Analyses, Chemical Analyses & Laboratory Quality Control
16.1 Bacteriological Analyses: Indicator Organisms, Membrane Filtration & Geometric Mean Reporting 16.2 Chemical Analyses & Laboratory Quality Control: COD, Nutrients, Metals, WET Testing & SOPs
17 Chapter 17: Safety Programs, Emergency Response, Security & Administrative Procedures
17.1 Lockout/Tagout, Machine Guarding, Fall Protection & PPE Programs 17.2 Emergency Response, Spill Control, Security & Vulnerability Assessments 17.3 Administrative Procedures: SOPs, O&M Reports, Discharge Monitoring Reports & Recordkeeping
1.3 Comminutors, Macerators & Velocity-Controlled Grit Channels
Key Takeaways Explain This Topic AI
Comminutors and sewage macerators shred coarse wastewater solids directly within the flowing stream into particles measuring 1/4 inch to 3/8 inch (6 to 10 mm) without physically removing any material from the liquid flow.
While shredding eliminates screenings handling and landfill hauling, shredded synthetic fibers and wipes frequently re-weave into dense rag balls in digesters, blind primary sludge pumps, and foul aeration diffusers, causing modern plants to replace comminutors with fine screens.
Inorganic grit particles have a specific gravity of approximately 2.65 (silica sand), whereas organic wastewater solids have a specific gravity of 1.05 to 1.20, allowing gravity settling separation under controlled horizontal velocity.
Horizontal velocity-controlled grit channels must maintain a flow velocity strictly between 0.75 and 1.25 ft/s (ideally 1.0 ft/s) with a detention time of 45 to 90 seconds (typically 60 seconds) to settle inorganics larger than 0.2 mm while keeping organic solids suspended.
Constant velocity across wide diurnal flow variations is maintained in rectangular grit channels using proportional weirs, Sutro weirs, or downstream Parshall flumes that adjust channel flow depth proportionally to flow rate.
Last updated: September 2026
1.3 Comminutors, Macerators & Velocity-Controlled Grit Channels
Exam Focus: Preliminary treatment encompasses both coarse solids size reduction and inorganic grit extraction. The Class I exam thoroughly tests comminutor mechanics and downstream drawbacks, specific gravity principles of grit versus organic solids (2.65 vs. 1.05–1.20), velocity boundaries in horizontal grit channels (0.75 to 1.25 ft/s), proportional weir velocity control, and velocity calculations using the continuity equation ( Q = A × V Q = A \times V Q = A × V ).
1. Comminutors, Barminutors & Sewage Macerators
Comminutors, barminutors, and in-line grinders are mechanical size-reduction machines installed directly in the headworks wastewater channel or pump suction piping. Unlike bar screens, which physically extract debris from the liquid flow, comminuting devices intercept coarse solids and shred, cut, or grind them into smaller particles (typically 1/4 inch to 3/8 inch / 6 to 10 mm) while remaining fully submerged in the wastewater stream . COMMINUTOR vs. BAR SCREENING COMPARISON
- [RAW WASTEWATER] ---> [Bar Screen] ----------> [Downstream Plant]
- | (Physical Extraction)
- v
- [Dumpster -> Landfill]
- [RAW WASTEWATER] ---> [Comminutor] ---------> [Shredded Solids Pass to Downstream Plant!]
- (Size Reduction Only) (Rags re-weave into balls in digesters)
- Equipment Configurations and Mechanical Components
Drum Comminutors: Consist of a revolving slotted cylindrical drum screen submerged in the channel. Wastewater flows inward through the drum slots and exits out the bottom. As the drum rotates against a stationary vertical cutting comb and shear bars, hardened tungsten carbide cutter teeth shear trapped rags and solids against the comb.
Barminutors: Feature a stationary vertical bar rack fitted with a high-speed mechanical cutting head that travels up and down the face of the rack, shredding solids trapped on the bars.
In-Line Twin-Shaft Grinders / Macerators: Feature two parallel hexagonal shafts rotating in opposite directions at differential speeds (e.g., 40 RPM and 60 RPM). Interlocking multi-tooth cam cutters exert extreme shearing torque, grinding wood, sneakers, plastic bottles, and wipes into fine slurry without requiring a wide open channel.
Advantages and Downstream Operational Drawbacks
Operational Attribute Comminutors & Grinders Mechanically Cleaned Bar Screens
Labor & Handling Low; completely submerged; no screenings to shovel, dewater, or handle. Moderate; requires monitoring washer-compactors and managing dumpsters.
Vector & Odor Control Excellent at headworks; eliminates open foul dumpsters and fly breeding. Requires enclosed compactors, ventilation, and odor scrubbers.
Capital & Installation Footprint Compact; fits easily in narrow pump station wet wells and channels. Requires substantial vertical headspace and building footprint.
Impact on Primary Clarifiers Negative: Finely chopped plastics, bottle caps, and grease float to form heavy, dense scum blankets that overload skimmers. Positive: Removes floatables before entering primary sedimentation.
Impact on Anaerobic Digesters Severe: Shredded synthetic wipe fibers and hairs re-agglomerate ("re-weave" or "rope") into dense, baseball-sized rag balls that wrap around mixing impellers, plug sludge heat exchangers, and require digester cleanouts. Protective: Eliminates fibrous materials, protecting digesters.
Impact on Sludge Pumps Negative: Chopped fibrous strands settle into primary sludge, balling up under pump suction/discharge check valves. Protective: Prevents pump blockages and check valve jamming.
Exam Key Point: Because comminuted solids remain in the liquid train and create severe downstream maintenance problems in anaerobic digesters and aeration basins, modern wastewater design standards strongly favor fine screening over comminution.
Comminutor Maintenance, Safety & Mechanical Protection
Rock Trap / Trash Well Cleaning: A recessed rock trap is positioned immediately upstream of the comminutor drum to capture gravel, river stones, metal bolts, and heavy inert debris before they enter the cutter teeth. Operators must inspect and clean the rock trap daily. If large rocks pass into the drum, they chip, shatter, or dull the brittle carbide cutter teeth.
Cutter Teeth and Shear Bar Clearances: Cutter teeth and shear bars experience continuous abrasive wear from grit. Operators must periodically measure tooth-to-comb clearances using feeler gauges (maintaining factory tolerances, typically 0.005 to 0.015 inches). Dull teeth must be sharpened or replaced; excessive clearance allows flexible rags to slip through uncut.
Mechanical Overload Protection: Comminutor drives are equipped with mechanical shear pins, slip friction clutches, or electrical auto-reversing relays. If a heavy metal tool or timber wedges in the cutters:
In modern units, the controller reverses shaft rotation for several seconds to clear the obstruction, attempting three forward/reverse cycles before tripping out.
In shear-pin-equipped units, the pin shears cleanly to decouple the motor and protect expensive planetary gearboxes.
Lockout/Tagout (LOTO): Under OSHA 1910.147, operators must de-energize, lock out, and tag the main electrical disconnect before entering the comminutor channel or touching the cutter drum. Never reach into a jammed comminutor without verified LOTO.
Shear Pin Replacement Rule: When replacing a sheared pin, always install an exact OEM shear pin with the engineered shear neck rating. NEVER substitute a standard hardened steel bolt (e.g., Grade 5 or Grade 8). A hardened bolt will not shear under overload, resulting in fractured drive shafts, cracked housings, or burned-out motor windings.
- 2. Fundamentals of Grit Removal: Specific Gravity Separation
- Definition and Composition of Grit
Grit consists of heavy, abrasive inorganic particulate matter carried in municipal wastewater, including:
- Natural silica sand and gravel (from soil runoff and pipe joints)
- Cinders, asphalt particles, and concrete dust (from street wash)
- Eggshells, bone chips, coffee grounds, and fruit seeds (from residential garbage disposals)
- Metal shavings and industrial mineral particles
- Specific Gravity Principles (Differential Density Separation)
The separation of grit from wastewater relies on the principle of differential gravity sedimentation (Stokes' Law discrete Type I settling) based on differences in specific gravity ( S . G . S.G. S . G . ): Specific Gravity ( S . G . ) = Density of Substance Density of Pure Water at 4°C \text{Specific Gravity } (S.G.) = \frac{\text{Density of Substance}}{\text{Density of Pure Water at 4°C}} Specific Gravity ( S . G . ) = Density of Pure Water at 4°C Density of Substance
Material Classification Specific Gravity Range Settling Velocity Characteristics Target Operating Response in Grit Channels
Inorganic Grit 2.65 (Silica sand baseline) Rapid discrete settling (~0.75 to 1.0 inch/second for 0.2 mm / 65-mesh particles) Must settle rapidly to the channel invert and be extracted from flow.
Organic Wastewater Solids 1.05 to 1.20 (Fecal solids, food wastes) Buoyant, slow settling (easily suspended by slight hydraulic turbulence) Must remain in buoyant suspension and carry through to the primary clarifier.
Wastewater Carrier Liquid 1.00 (Pure water equivalent) Fluid medium Flows continuously through channel.
Because inorganic grit ( S . G . = 2.65 S.G. = 2.65 S . G . = 2.65 ) is more than twice as dense as organic wastewater solids ( S . G . = 1.05 to 1.20 S.G. = 1.05\text{ to }1.20 S . G . = 1.05 to 1.20 ), maintaining a controlled horizontal flow velocity of 0.75 to 1.25 ft/s (ideally 1.0 ft/s) provides precisely enough hydraulic energy to prevent light organics from settling while allowing dense grit to drop cleanly out of suspension.
3. Horizontal Velocity-Controlled Grit Channels
Horizontal grit channels are long, narrow rectangular or trapezoidal concrete flumes designed to provide a uniform velocity and detention time.
Core Design & Operating Criteria
Target Horizontal Velocity: 0.75 to 1.25 ft/s (0.23 to 0.38 m/s) , with an optimum design velocity of 1.0 ft/s (0.30 m/s) .
Detention Time: 45 to 90 seconds (standard design target is 60 seconds ).
Particle Size Removal: Designed to capture 95% of inorganic particles ≥ 0.2 mm \ge 0.2\text{ mm} ≥ 0.2 mm (diameter corresponding to 65-mesh sand).
Channel Configuration: Minimum of two parallel channels equipped with isolating influent/effluent slide gates to permit dewatering, manual grit removal, or equipment maintenance in one channel while the other handles full plant flow.
Severe Consequences of Velocity Deviations VELOCITY WINDOW IN HORIZONTAL GRIT CHANNELS
- < 0.75 ft/s 0.75 to 1.25 ft/s > 1.25 ft/s
- [TOO SLOW] [OPTIMAL: 1.0 ft/s] [TOO FAST]
- Organic solids settle; Grit settles cleanly; Grit is swept into plant;
- H2S odors; septic grit Organics stay in suspension Severe pump & digester wear
- 1. Velocity Too Low (<0.75 ft/s)
Diagnostic Indicator: Recovered grit is dark grey/black, smells like rotten eggs, and contains large amounts of organic food scraps and fecal material.
Process Impact: Organic solids settle out with the grit, rapidly fermenting anaerobically into hydrogen sulfide (H2S) gas and volatile organic acids. The resulting contaminated grit cannot be accepted at a municipal landfill without expensive, energy-intensive washing.
Operator Action: Increase velocity to 1.0 ft/s by taking one parallel channel out of service (diverting all flow to a single channel) or adjusting the downstream weir crest.
2. Velocity Too High (>1.25 ft/s)
Diagnostic Indicator: Little or no grit accumulates in the grit channel hopper; severe abrasive wear observed downstream on primary sludge pumps.
Process Impact: Hydraulic scouring sweeps grit right through the channel and into the primary clarifier. Grit settles into primary sludge hoppers, causing:
Rapid abrasive erosion of positive displacement sludge pump pistons, stator liners, and mechanical seals.
Heavy scouring of piping elbows and check valves.
Accumulation of dense grit beds in the bottom of anaerobic digesters, permanently occupying 20% to 30% of active digester volume and requiring costly digester shutdowns for manual mining.
Operator Action: Reduce velocity to 1.0 ft/s by bringing an additional parallel channel into service or adjusting the downstream flow control device.
4. Velocity Control Devices: Proportional and Sutro Weirs
In an ordinary open rectangular flume, as flow rate ( Q Q Q ) increases, water depth ( h h h ) rises, increasing the cross-sectional area ( A A A ). Because diurnal flows fluctuate dramatically between nighttime minimums and daytime peak hours, an unregulated rectangular channel would experience unacceptably low velocities at night and excessive scouring velocities during peak hours.
To maintain a constant velocity of 1.0 ft/s across varying depths and flows, engineers install specialized flow control structures at the discharge end of the channel:
Proportional Weir
Operating Principle: A specially contoured metal plate weir whose sides curve inward parabolically toward the top. The open area narrows with increasing depth such that the discharge flow rate ( Q Q Q ) is directly proportional to the water depth ( h h h ) above the weir crest ( Q ∝ h Q \propto h Q ∝ h ).
When installed in a rectangular channel, as depth rises with increased flow, the cross-sectional area and flow rate increase in exact direct proportion, maintaining a completely constant horizontal velocity of 1.0 ft/s throughout the channel invert.
Sutro Weir
A specialized variant of the proportional weir with a straight horizontal base crest and curved vertical sides. Commonly utilized in shallow grit channels to provide precise proportional discharge starting immediately at the channel invert.
Parshall Flume with Parabolic Channel
Alternatively, engineers shape the channel cross-section into a parabola and place a Parshall flume immediately downstream. As water backs up through the flume throat, the depth in the parabolic channel varies such that velocity remains approximately 1.0 ft/s across all flow ranges.
5. Velocity and Hydraulic Calculations for Operators
Operators must be able to calculate channel cross-sectional area, flow rate in cubic feet per second (cfs), flow velocity, and detention time.
The Continuity Equation Q = A × V Q = A \times V Q = A × V Velocity ( V ) = Q A \text{Velocity } (V) = \frac{Q}{A} Velocity ( V ) = A Q
Where:
Q = Flow rate in cubic feet per second (cfs) Q = \text{Flow rate in cubic feet per second (cfs)} Q = Flow rate in cubic feet per second (cfs)
A = Cross-sectional area of water in square feet ( ft 2 ) = Width (ft) × Depth (ft) A = \text{Cross-sectional area of water in square feet } (\text{ft}^2) = \text{Width (ft)} \times \text{Depth (ft)} A = Cross-sectional area of water in square feet ( ft 2 ) = Width (ft) × Depth (ft)
V = Velocity in feet per second (ft/s) V = \text{Velocity in feet per second (ft/s)} V = Velocity in feet per second (ft/s)
Key Conversion Constants
1 MGD = 1.547 cfs 1\text{ MGD} = 1.547\text{ cfs} 1 MGD = 1.547 cfs (Derived from: 1 , 000 , 000 gal/day ÷ ( 7.48 gal/ft 3 × 86 , 400 sec/day ) = 1.5472 cfs 1,000,000\text{ gal/day} \div (7.48\text{ gal/ft}^3 \times 86,400\text{ sec/day}) = 1.5472\text{ cfs} 1 , 000 , 000 gal/day ÷ ( 7.48 gal/ft 3 × 86 , 400 sec/day ) = 1.5472 cfs )
- 1 cu ft = 7.48 gallons 1\text{ cu ft} = 7.48\text{ gallons} 1 cu ft = 7.48 gallons
- 1 minute = 60 seconds 1\text{ minute} = 60\text{ seconds} 1 minute = 60 seconds
- Worked Operational Calculations
- Calculation 1: Determining Channel Velocity
Problem: A rectangular horizontal grit channel is 3.0 feet wide. An operator measures the wastewater depth as 1.5 feet. The influent plant flow meter indicates a flow of 3.25 MGD. Calculate the horizontal velocity in feet per second, and evaluate whether the velocity is within design standards.
Step 1: Convert flow rate from MGD to cfs: Q = 3.25 MGD × 1.547 cfs/MGD = 5.028 cfs Q = 3.25\text{ MGD} \times 1.547\text{ cfs/MGD} = 5.028\text{ cfs} Q = 3.25 MGD × 1.547 cfs/MGD = 5.028 cfs
Step 2: Calculate the water cross-sectional area: A = Width × Depth = 3.0 ft × 1.5 ft = 4.5 ft 2 A = \text{Width} \times \text{Depth} = 3.0\text{ ft} \times 1.5\text{ ft} = 4.5\text{ ft}^2 A = Width × Depth = 3.0 ft × 1.5 ft = 4.5 ft 2
Step 3: Calculate the velocity: V = Q A = 5.028 cfs 4.5 ft 2 = 1.117 ft/s ≈ 1.12 ft/s V = \frac{Q}{A} = \frac{5.028\text{ cfs}}{4.5\text{ ft}^2} = 1.117\text{ ft/s} \approx 1.12\text{ ft/s} V = A Q = 4.5 ft 2 5.028 cfs = 1.117 ft/s ≈ 1.12 ft/s
Operational Evaluation: The calculated velocity of 1.12 ft/s falls cleanly within the acceptable design range of 0.75 to 1.25 ft/s , very close to the optimal 1.0 ft/s target.
Calculation 2: Determining Channel Detention Time
Problem: The grit channel in Calculation 1 has an effective length of 60 feet. What is the hydraulic detention time in seconds? Detention Time ( t ) = Length (ft) Velocity (ft/s) = 60 ft 1.12 ft/s = 53.6 seconds \text{Detention Time } (t) = \frac{\text{Length (ft)}}{\text{Velocity (ft/s)}} = \frac{60\text{ ft}}{1.12\text{ ft/s}} = 53.6\text{ seconds} Detention Time ( t ) = Velocity (ft/s) Length (ft) = 1.12 ft/s 60 ft = 53.6 seconds
Operational Evaluation: The detention time of 53.6 seconds meets the standard design requirement of 45 to 90 seconds (nominally 60 seconds).
6. Diagnostic Troubleshooting for Comminutors & Grit Channels
Equipment / Process Observable Symptom Probable Root Cause Defensible Operator Action
Comminutor Motor Tripped Motor de-energized; thermal overload tripped; shear pin sheared; drum seized. 1. Foreign rigid object (bolt, rock, rebar, timber) wedged in cutter teeth.; 2. Rock trap filled to capacity, overflowing rocks into drum.; 3. Severe bearing failure or lack of lubrication. 1. Implement strict electrical LOTO.; 2. Manually inspect drum and extract obstruction using non-sparking pry bar.; 3. Clean upstream rock trap thoroughly.; 4. Inspect cutter teeth for fractures; replace shear pin only with OEM-rated pin ; reset thermal overload.
Grit Contains Excessive Organics (Foul Odor) Recovered grit is dark, greasy, and smells strongly of hydrogen sulfide (H2S); volatile solids >20%. 1. Channel velocity is too low (<0.75 ft/s), allowing light organics to settle.; 2. Downstream proportional weir crest submerged or blinded by rags.; 3. Channel width too wide for current low seasonal flow. 1. Measure water depth and flow; calculate velocity ( V = Q / A V = Q / A V = Q / A ).; 2. Clean proportional weir plate of all rags and debris.; 3. Take one parallel grit channel offline to direct all flow through a single channel, raising velocity back to 1.0 ft/s.
Grit Carrying Over into Primary Clarifiers Abrasive wear on primary sludge pumps; grit beds accumulating in primary sludge hoppers. 1. Channel velocity is too high (>1.25 ft/s), scouring grit out of channel.; 2. Grit channel hopper is full; settled grit is being re-suspended.; 3. Detention time is too short (<45 seconds) during storm peak flows. 1. Bring a second parallel grit channel online immediately to split flow and reduce velocity.; 2. Increase frequency of grit pumping or bucket elevator cleanouts.; 3. Clean downstream weir to restore proper hydraulic profile.
Comminutor Passing Long Rags & Strings Fibrous strands and intact rags passing through drum, wrapping around downstream pump impellers. 1. Cutter teeth dull, chipped, or broken.; 2. Excessive clearance between rotating teeth and stationary shear comb.; 3. Drum rotation speed slipping. 1. Perform LOTO; inspect cutter teeth with feeler gauge; sharpen or replace dull/chipped teeth.; 2. Adjust stationary comb clearance to manufacturer tolerance (0.005 to 0.015 in).; 3. Inspect drive belt tension or gear reducer for mechanical slip.
Water Backing Up Upstream of Grit Channel High water alarm in upstream channel; approach velocity slowing drastically below 1.0 ft/s. 1. Proportional weir or effluent slide gate blinded with heavy rags and plastic bags.; 2. Downstream Parshall flume experiencing backwater submergence. 1. Rake and clean the face of the proportional weir plate.; 2. Check downstream processes for hydraulic bottlenecks causing headloss backwater.