Study guide

13.1 Tertiary Filtration Equipment: Granular Media, Disc & Cloth Filters

ABC/WPI Wastewater Treatment Operator Class I Certification Exam Exam

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: Introduction, Plant Overview & Preliminary Screening

1.1 Exam Structure, Plant Layout & Unit Process Flow 1.2 Bar Screens, Trash Racks & Mechanically Cleaned Screens 1.3 Comminutors, Macerators & Velocity-Controlled Grit Channels

2 Chapter 2: Grit Removal, Flow Equalization & Primary Clarification

2.1 Aerated Grit Chambers, Vortex Separators & Grit Handling 2.2 Primary Sedimentation Principles & Design Parameters 2.3 Primary Clarifier Operation, Sludge Pumping & Troubleshooting

3 Chapter 3: Secondary Biological Treatment — Activated Sludge Fundamentals

3.1 Activated Sludge Biochemistry & Aeration Tank Mechanics 3.2 Process Control Parameters: F/M Ratio, MCRT & Sludge Wasting 3.3 Settleability Testing, Sludge Volume Index & Clarifier Blanket Dynamics 3.4 Activated Sludge Troubleshooting & Microscopic Bioindicators

4 Chapter 4: Alternative Biological Processes & Fixed-Film Systems

4.1 Extended Aeration Package Plants, Oxidation Ditches & SBR Cycles 4.2 Fixed-Film Systems: Trickling Filters & Rotating Biological Contactors (RBCs) 4.3 Waste Stabilization Ponds, Facultative Lagoons & Aerated Ponds

5 Chapter 5: Disinfection Systems & Effluent Management

5.1 Chlorination Chemistry, Feed Equipment & Chlorine Contact Basins 5.2 Dechlorination Systems, Sulfur Dioxide & Bisulfite Chemistry 5.3 Ultraviolet (UV) Disinfection Mechanics, Dosage & Effluent Standards

6 Chapter 6: Solids Handling, Digestion & Biosolids Management

6.1 Sludge Thickening: Gravity, DAF & Gravity Belt Thickeners 6.2 Aerobic & Anaerobic Digestion Principles & Operational Control 6.3 Dewatering Technologies: Belt Filter Presses, Centrifuges & Drying Beds 6.4 Biosolids Regulations, EPA 40 CFR Part 503 & Land Application

7 Chapter 7: Sampling Protocols, Laboratory Testing & Operator Math

7.1 Wastewater Sampling Methods, Representative Samples & Chain of Custody 7.2 Biochemical Oxygen Demand (BOD5/CBOD5) & Total Suspended Solids (TSS) Analysis 7.3 Routine Process Testing: Dissolved Oxygen, pH, Settleable Solids & Ammonia 7.4 Essential Operator Math: Flow Conversions, Detention Time, Loading Rates & Pounds Formula

8 Chapter 8: Safety, Collection Systems, Utility Operations & Regulations

8.1 Confined Space Entry, Atmospheric Testing & Hazardous Gas Safety 8.2 Chemical Safety: Chlorine Gas Cylinders, Hypochlorite & Hazard Communication 8.3 Collection Systems, Lift Stations, Inflow/Infiltration & Clean Water Act / NPDES Compliance

9 Chapter 9: Pumps, Motors, Drives & Plant Electrical Systems

9.1 Centrifugal Pumps: Types, Curves, Cavitation & Seal Maintenance 9.2 Positive Displacement Pumps: Progressive Cavity, Plunger, Diaphragm & Peristaltic 9.3 Motors, Motor Control Centers, Variable Frequency Drives & Electrical Safety

10 Chapter 10: Aeration, Mixing & Chemical Feed Equipment

10.1 Aeration Equipment: Blowers, Diffusers, Surface Aerators & Air Distribution 10.2 Mixers, Flash Mixing & Chemical Feed Systems

11 Chapter 11: Instrumentation, Online Analyzers, SCADA & Auxiliary Power

11.1 Field Instrumentation: Flow Measurement, Level Sensing & Pressure 11.2 Online Process Analyzers: Dissolved Oxygen, pH, ORP, Turbidity & Chlorine Residual 11.3 SCADA, Telemetry, Alarm Management, Security & Auxiliary Power

12 Chapter 12: Valves, Piping, Compressors & Ancillary Plant Equipment

12.1 Valves, Piping, Air Compressors, Conveyors, Hoists & Cranes

13 Chapter 13: Tertiary Filtration & Effluent Polishing

13.1 Tertiary Filtration Equipment: Granular Media, Disc & Cloth Filters 13.2 Filtration Process Control: Loading Rates, Headloss, Breakthrough & Backwash Triggers

14 Chapter 14: Activated Sludge Configurations & Biological Nutrient Removal

14.1 Activated Sludge Configurations: Conventional Plug Flow, Complete Mix, Step Feed & Contact Stabilization 14.2 Nutrient Removal: Nitrification, Denitrification & Anaerobic/Anoxic/Aerobic Zones

15 Chapter 15: Chemical Dosing Processes, Effluent Disposal & Solids Disposal

15.1 Chemical Dosing Processes: Coagulation, Flocculation, pH Adjustment & Dosage Calculations 15.2 Effluent Disposal: Surface Water Discharge & Rapid Infiltration Basins; Solids Disposal to Landfill

16 Chapter 16: Bacteriological Analyses, Chemical Analyses & Laboratory Quality Control

16.1 Bacteriological Analyses: Indicator Organisms, Membrane Filtration & Geometric Mean Reporting 16.2 Chemical Analyses & Laboratory Quality Control: COD, Nutrients, Metals, WET Testing & SOPs

17 Chapter 17: Safety Programs, Emergency Response, Security & Administrative Procedures

17.1 Lockout/Tagout, Machine Guarding, Fall Protection & PPE Programs 17.2 Emergency Response, Spill Control, Security & Vulnerability Assessments 17.3 Administrative Procedures: SOPs, O&M Reports, Discharge Monitoring Reports & Recordkeeping

13.1 Tertiary Filtration Equipment: Granular Media, Disc & Cloth Filters

Key Takeaways Explain This Topic AI

A granular media filter is built in layers — filter media, support gravel, and an underdrain — with backwash troughs above the bed, and each layer has a distinct function that fails in a distinct way.

Dual-media filters place lighter, coarser anthracite above heavier, finer sand so that flow encounters coarse-to-fine grading, which stores solids through the depth of the bed instead of plugging the surface.

Effective size and uniformity coefficient describe a filter media, with effective size being the sieve opening passing 10 percent of the media by weight and uniformity coefficient being the ratio of the 60 percent size to the 10 percent size.

Cloth disc filters mount media on partially submerged rotating discs and clean themselves with suction shoes, using far less backwash water and floor space than granular media filters.

Air scour and surface wash break up the compacted surface layer that water alone cannot dislodge, and without them a granular bed develops mudballs and cracks.

Last updated: September 2026

13.1 Tertiary Filtration Equipment: Granular Media, Disc & Cloth Filters

Exam Focus: "Tertiary treatment equipment — Filtration; Media filtration (e.g., sand, anthracite, disc filter)" is listed in the Equipment content area, and the matching process appears again in Treatment Process Evaluation and Adjustment. Tertiary filtration is the step that takes a secondary effluent from roughly 15 to 30 mg/L TSS down to single digits.

1. Why Plants Filter

Secondary clarification cannot remove the fine, low-density particles that escape a biological floc. Tertiary filtration exists to:

Meet effluent limits tighter than conventional secondary standards — for example permits requiring effluent TSS well below 30 mg/L.

Remove the particles that shield pathogens from UV disinfection and consume chlorine, so downstream disinfection actually works.

Remove particulate phosphorus after chemical precipitation.

Produce water suitable for reuse — plant service water, irrigation, or industrial supply.

2. Granular Media Filter Construction

From the bottom up:

Layer Function Failure Mode

Underdrain Collects filtered water and distributes backwash water evenly across the entire bed Broken or plugged laterals or nozzles cause uneven backwash, which leaves dirty zones and can boil media out in others

Support gravel Graded layers holding fine media above the underdrain Gravel upset — violent or uneven backwash disturbs the graded layers and lets media migrate into the underdrain

Filter media Does the actual filtration Media loss over the troughs, mudballs, surface cracking, compaction

Freeboard / backwash troughs Carry spent backwash water away above the expanded bed Troughs set too low let media wash out during backwash

Media Properties

Effective size (ES) is the sieve opening that passes 10 percent of the media by weight. Smaller effective size means finer filtration and faster headloss development.

Uniformity coefficient (UC) is the ratio of the 60 percent passing size to the 10 percent passing size. A UC near 1.0 means very uniform grains; a high UC means a wide range of sizes that pack tightly and plug at the surface.

Specific gravity determines where a medium settles after backwash: anthracite is lighter (roughly 1.4 to 1.7) than silica sand (roughly 2.6) , and garnet or ilmenite is heavier still (roughly 4.0 to 4.5).

Single, Dual, and Multi-Media

A single-media sand filter does most of its work at the very top of the bed. Solids plug that thin surface layer, headloss climbs quickly, and run times are short.

A dual-media filter solves this by exploiting specific gravity. After backwash, the lighter, coarser anthracite settles on top of the heavier, finer sand . Flow therefore travels from coarse to fine, so large particles are captured deep in the anthracite while progressively finer particles are captured below. The result is in-depth filtration : far more solids storage capacity, longer runs, and lower headloss for the same water quality. A multi-media (mixed-media) filter adds a garnet layer at the bottom for still finer polishing.

Exam point. The reason anthracite goes on top is not that it filters better — it is that anthracite's lower specific gravity makes it re-stratify above the sand every time the bed is backwashed and re-settles. Grading is achieved by density, automatically.

3. Filter Configurations

Configuration How It Works Characteristics

Conventional gravity filter Water flows down through a fixed bed; the filter is taken offline periodically for backwash Simple, robust, well understood; needs backwash pumps or a clearwell and a place to send spent backwash

Traveling bridge filter A moving bridge backwashes one narrow cell at a time while the rest of the filter stays in service Continuous service, shallow bed, low backwash volume per event

Continuous backwash upflow sand filter Water flows upward through a downward-moving sand bed while an airlift continuously washes sand at the center and returns it clean to the top Never taken offline; no backwash pumps or valves; steady small reject stream

Cloth disc filter Cloth media on partially submerged discs rotating slowly on a center shaft; solids collect on the outside of the cloth and are removed by suction shoes as the discs turn Very small footprint, very low backwash volume, low headloss, no media to lose; increasingly the default retrofit choice

Pressure filter Granular media in a closed pressure vessel Used where downstream pressure is needed; harder to observe the bed

4. Backwash and Cleaning Systems

Water alone cannot dislodge the compacted, biologically sticky surface layer that forms on a wastewater filter. Auxiliary scour is essential:

Air scour injects air beneath or into the bed, and the rising bubbles abrade the grains against one another to break the deposits loose. Air scour is normally applied first, or simultaneously at reduced water rate, then water alone completes the wash.

Surface wash uses fixed or rotating high-pressure nozzles just above the settled bed to attack the surface crust.

Backwash water is supplied from a dedicated backwash pump, a clearwell, or an elevated tank.

Without effective auxiliary scour, a granular bed develops:

Mudballs — accreted lumps of media, biological solids, and grease that grow, sink into the bed, and remove filtering volume.

Surface cracking and shrinkage — the bed pulls away from the walls, and water short-circuits down the crack, bypassing the media entirely.

Media cementing — a hardened layer that no backwash will restore, requiring media replacement.

Backwash troughs must sit high enough above the settled bed to accommodate expansion during backwash. Media appearing in the spent backwash, or a measurably falling bed depth over time, means the backwash rate is too high or the troughs are too low.