Study guide
16.2 Chemical Analyses & Laboratory Quality Control: COD, Nutrients, Metals, WET Testing & SOPs
ABC/WPI Wastewater Treatment Operator Class I Certification Exam Exam
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: Introduction, Plant Overview & Preliminary Screening
1.1 Exam Structure, Plant Layout & Unit Process Flow 1.2 Bar Screens, Trash Racks & Mechanically Cleaned Screens 1.3 Comminutors, Macerators & Velocity-Controlled Grit Channels
2 Chapter 2: Grit Removal, Flow Equalization & Primary Clarification
2.1 Aerated Grit Chambers, Vortex Separators & Grit Handling 2.2 Primary Sedimentation Principles & Design Parameters 2.3 Primary Clarifier Operation, Sludge Pumping & Troubleshooting
3 Chapter 3: Secondary Biological Treatment — Activated Sludge Fundamentals
3.1 Activated Sludge Biochemistry & Aeration Tank Mechanics 3.2 Process Control Parameters: F/M Ratio, MCRT & Sludge Wasting 3.3 Settleability Testing, Sludge Volume Index & Clarifier Blanket Dynamics 3.4 Activated Sludge Troubleshooting & Microscopic Bioindicators
4 Chapter 4: Alternative Biological Processes & Fixed-Film Systems
4.1 Extended Aeration Package Plants, Oxidation Ditches & SBR Cycles 4.2 Fixed-Film Systems: Trickling Filters & Rotating Biological Contactors (RBCs) 4.3 Waste Stabilization Ponds, Facultative Lagoons & Aerated Ponds
5 Chapter 5: Disinfection Systems & Effluent Management
5.1 Chlorination Chemistry, Feed Equipment & Chlorine Contact Basins 5.2 Dechlorination Systems, Sulfur Dioxide & Bisulfite Chemistry 5.3 Ultraviolet (UV) Disinfection Mechanics, Dosage & Effluent Standards
6 Chapter 6: Solids Handling, Digestion & Biosolids Management
6.1 Sludge Thickening: Gravity, DAF & Gravity Belt Thickeners 6.2 Aerobic & Anaerobic Digestion Principles & Operational Control 6.3 Dewatering Technologies: Belt Filter Presses, Centrifuges & Drying Beds 6.4 Biosolids Regulations, EPA 40 CFR Part 503 & Land Application
7 Chapter 7: Sampling Protocols, Laboratory Testing & Operator Math
7.1 Wastewater Sampling Methods, Representative Samples & Chain of Custody 7.2 Biochemical Oxygen Demand (BOD5/CBOD5) & Total Suspended Solids (TSS) Analysis 7.3 Routine Process Testing: Dissolved Oxygen, pH, Settleable Solids & Ammonia 7.4 Essential Operator Math: Flow Conversions, Detention Time, Loading Rates & Pounds Formula
8 Chapter 8: Safety, Collection Systems, Utility Operations & Regulations
8.1 Confined Space Entry, Atmospheric Testing & Hazardous Gas Safety 8.2 Chemical Safety: Chlorine Gas Cylinders, Hypochlorite & Hazard Communication 8.3 Collection Systems, Lift Stations, Inflow/Infiltration & Clean Water Act / NPDES Compliance
9 Chapter 9: Pumps, Motors, Drives & Plant Electrical Systems
9.1 Centrifugal Pumps: Types, Curves, Cavitation & Seal Maintenance 9.2 Positive Displacement Pumps: Progressive Cavity, Plunger, Diaphragm & Peristaltic 9.3 Motors, Motor Control Centers, Variable Frequency Drives & Electrical Safety
10 Chapter 10: Aeration, Mixing & Chemical Feed Equipment
10.1 Aeration Equipment: Blowers, Diffusers, Surface Aerators & Air Distribution 10.2 Mixers, Flash Mixing & Chemical Feed Systems
11 Chapter 11: Instrumentation, Online Analyzers, SCADA & Auxiliary Power
11.1 Field Instrumentation: Flow Measurement, Level Sensing & Pressure 11.2 Online Process Analyzers: Dissolved Oxygen, pH, ORP, Turbidity & Chlorine Residual 11.3 SCADA, Telemetry, Alarm Management, Security & Auxiliary Power
12 Chapter 12: Valves, Piping, Compressors & Ancillary Plant Equipment
12.1 Valves, Piping, Air Compressors, Conveyors, Hoists & Cranes
13 Chapter 13: Tertiary Filtration & Effluent Polishing
13.1 Tertiary Filtration Equipment: Granular Media, Disc & Cloth Filters 13.2 Filtration Process Control: Loading Rates, Headloss, Breakthrough & Backwash Triggers
14 Chapter 14: Activated Sludge Configurations & Biological Nutrient Removal
14.1 Activated Sludge Configurations: Conventional Plug Flow, Complete Mix, Step Feed & Contact Stabilization 14.2 Nutrient Removal: Nitrification, Denitrification & Anaerobic/Anoxic/Aerobic Zones
15 Chapter 15: Chemical Dosing Processes, Effluent Disposal & Solids Disposal
15.1 Chemical Dosing Processes: Coagulation, Flocculation, pH Adjustment & Dosage Calculations 15.2 Effluent Disposal: Surface Water Discharge & Rapid Infiltration Basins; Solids Disposal to Landfill
16 Chapter 16: Bacteriological Analyses, Chemical Analyses & Laboratory Quality Control
16.1 Bacteriological Analyses: Indicator Organisms, Membrane Filtration & Geometric Mean Reporting 16.2 Chemical Analyses & Laboratory Quality Control: COD, Nutrients, Metals, WET Testing & SOPs
17 Chapter 17: Safety Programs, Emergency Response, Security & Administrative Procedures
17.1 Lockout/Tagout, Machine Guarding, Fall Protection & PPE Programs 17.2 Emergency Response, Spill Control, Security & Vulnerability Assessments 17.3 Administrative Procedures: SOPs, O&M Reports, Discharge Monitoring Reports & Recordkeeping
16.2 Chemical Analyses & Laboratory Quality Control: COD, Nutrients, Metals, WET Testing & SOPs
Key Takeaways Explain This Topic AI
Chemical oxygen demand uses a strong chemical oxidant to measure nearly all oxidizable matter in about two hours, so COD is always higher than the five-day BOD on the same sample and a stable plant-specific ratio between them lets COD serve as a same-day process control surrogate.
Whole effluent toxicity testing exposes live test organisms to effluent and measures aggregate toxicity, capturing combined and unidentified effects that no chemical-specific test can detect.
Compliance results must come from methods approved under 40 CFR Part 136, and an unapproved method produces a number that cannot legally be reported no matter how accurate it is.
Laboratory quality control rests on written SOPs plus method blanks, duplicates, spikes, calibration standards, and control charts, and instrument records such as balance checks and incubator temperature logs are as important as the analytical results.
COD digestion reagents contain dichromate, mercury, silver, and concentrated sulfuric acid, so spent COD vials are a hazardous waste stream requiring proper accumulation and disposal rather than drain discharge.
Last updated: September 2026
16.2 Chemical Analyses & Laboratory Quality Control: COD, Nutrients, Metals, WET Testing & SOPs
Exam Focus: The Laboratory Analysis content area names chemical analyses (COD, nutrients, metals), biological analyses including WET , and both "Follow laboratory Standard Operating Procedures (SOPs)" and "Operate and maintain laboratory instrumentation." Section 7.2 covered BOD and TSS; this section covers everything else the criteria list.
1. Chemical Oxygen Demand (COD)
COD measures the oxygen equivalent of matter that can be chemically oxidized. A sample is digested in a sealed vial with potassium dichromate in concentrated sulfuric acid at 150 degrees C for two hours, with a silver catalyst and mercuric sulfate to suppress chloride interference. The amount of dichromate consumed is measured colorimetrically and expressed as mg/L of oxygen.
COD vs. BOD
- BOD5 COD
- Oxidizing agent Living microorganisms Strong chemical oxidant (dichromate)
- Time to result 5 days About 2 hours
What it measures Only what organisms can biodegrade in 5 days Nearly everything oxidizable, biodegradable or not
- Relative magnitude Always lower Always higher on the same sample
- Best use Permit compliance; the regulatory parameter Same-day process control and troubleshooting
Because COD captures non-biodegradable material as well, COD always exceeds BOD5 on the same sample . Each plant develops its own reasonably stable COD-to-BOD ratio for a given stream, and once that ratio is established a same-day COD result can be used to estimate the loading long before the five-day BOD is available. A sudden change in the COD-to-BOD ratio is itself a valuable signal — it usually means a non-biodegradable industrial discharge has entered the plant.
Waste handling. Spent COD vials contain dichromate, mercury, silver, and strong acid. They are a hazardous waste stream and must be accumulated and disposed of properly. Pouring them down the drain sends heavy metals straight into the plant's own influent and is a serious violation.
2. Nutrient Analyses
Parameter Common Methods Notes
Ammonia nitrogen (NH3-N) Salicylate colorimetric, ion selective electrode, automated phenate The parameter most often carrying a permit limit; drives nitrification control
Nitrite / nitrate nitrogen Cadmium reduction, chromotropic acid, ion chromatography Nitrate confirms nitrification; nitrate in the RAS predicts rising sludge
Total Kjeldahl Nitrogen (TKN) Digestion followed by ammonia determination Organic nitrogen plus ammonia; TKN plus nitrite plus nitrate gives total nitrogen
Total phosphorus Persulfate digestion followed by ascorbic acid colorimetric Digestion is essential — it converts all phosphorus forms to orthophosphate
Orthophosphate Ascorbic acid colorimetric, no digestion The immediately available fraction; used for biological phosphorus process control
Alkalinity Titration to a fixed endpoint pH Reported as mg/L CaCO3; the essential nitrification control test (Section 14.2)
The distinction between total phosphorus and orthophosphate is a frequent exam point: total phosphorus requires a digestion step to convert organic and condensed phosphates into orthophosphate before color development, while orthophosphate is measured directly on a filtered sample with no digestion.
3. Metals
Metals analysis normally goes to a contract laboratory, but the operator collects the sample and the sample determines the result :
Preserve with nitric acid to pH less than 2 unless the method directs otherwise. Without acid preservation, dissolved metals adsorb onto the container walls and the reported concentration is low.
Use the container type the method specifies — plastic for most metals, and note that mercury has its own requirements.
Total versus dissolved metals is a real distinction: dissolved metals require field filtration before preservation. Filtering after acidification gives a meaningless result.
Metals matter to a treatment plant in two directions: they inhibit the biological process (nitrifiers fail first), and they limit biosolids land application under 40 CFR Part 503 (Section 6.4). A metals excursion usually means an industrial user needs attention through the pretreatment program.
4. Whole Effluent Toxicity (WET) Testing
WET testing is listed under biological analyses in the Need-to-Know Criteria. It exposes live test organisms to a series of effluent dilutions and measures their survival, growth, or reproduction.
Acute tests measure survival over a short exposure, typically 48 hours.
Chronic tests measure sublethal effects — growth and reproduction — over a longer exposure.
Common freshwater test organisms are the water flea Ceriodaphnia dubia and the fathead minnow Pimephales promelas .
Why WET exists. Chemical-specific tests only find what you decide to look for. WET testing measures the aggregate toxicity of the effluent as the receiving stream actually experiences it, including combined effects of multiple substances and toxicity from compounds nobody analyzed. A plant that passes every chemical limit can still fail a WET test — and when it does, the response is a toxicity identification and reduction evaluation , working systematically to find and eliminate the source, very often an industrial contributor.
5. Quality Control — What Makes Data Defensible
- QC Element What It Checks
- Written SOPs That the procedure is performed the same way by every analyst on every shift
- Method blank Contamination in reagents, glassware, or technique
- Duplicate Precision — how repeatable the result is
- Matrix spike Accuracy and recovery in the actual sample matrix, not in clean water
- Calibration standards / curve That the instrument response is correct across the working range
- Control charts Trends and drift over time that a single QC result would not reveal
- Chain of custody Documented possession of the sample from collection to result
- Approved method (40 CFR Part 136) That the result is legally reportable
Approved methods are not optional. For NPDES compliance, results must be produced by a method approved under 40 CFR Part 136 for that parameter. An unapproved method — however accurate, however convenient — produces a number that cannot be reported for compliance. Many states additionally require the laboratory or the individual analyst to be certified for the parameters reported.
6. Laboratory Instrumentation and Records
The Need-to-Know Criteria includes "Operate and maintain laboratory instrumentation." That means:
Analytical balance — level it, keep it away from drafts and vibration, and verify with class weights on a documented schedule.
Incubators, ovens, water baths, and refrigerators — record temperatures daily against a NIST-traceable thermometer. The fecal coliform incubator's 44.5 plus or minus 0.2 degrees C is unforgiving, and an out-of-range incubator invalidates every result run in it.
Pipettes — verify volume gravimetrically on schedule.
Reagents — label with contents, concentration, preparation date, expiration, and preparer. Discard expired reagents ; an expired buffer or standard silently biases every result calibrated against it.
Glassware — dedicated cleaning procedures, and never use detergent residue-contaminated glassware for BOD work.
Laboratory Safety
Work with acids, digestion reagents, and volatile solvents in a functioning fume hood .
Always add acid to water, never water to acid.
Eyewash and safety shower must be unobstructed, accessible within seconds, and flushed on schedule.
Store incompatible reagents separately — acids apart from bases, oxidizers apart from organics.
Keep the safety data sheet for every chemical accessible, and wear the eye, hand, and body protection the SDS specifies.
Never pipette by mouth, and never eat, drink, or store food in the laboratory.