Study guide

17.3 Administrative Procedures: SOPs, O&M Reports, Discharge Monitoring Reports & Recordkeeping

ABC/WPI Wastewater Treatment Operator Class I Certification Exam Exam

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: Introduction, Plant Overview & Preliminary Screening

1.1 Exam Structure, Plant Layout & Unit Process Flow 1.2 Bar Screens, Trash Racks & Mechanically Cleaned Screens 1.3 Comminutors, Macerators & Velocity-Controlled Grit Channels

2 Chapter 2: Grit Removal, Flow Equalization & Primary Clarification

2.1 Aerated Grit Chambers, Vortex Separators & Grit Handling 2.2 Primary Sedimentation Principles & Design Parameters 2.3 Primary Clarifier Operation, Sludge Pumping & Troubleshooting

3 Chapter 3: Secondary Biological Treatment — Activated Sludge Fundamentals

3.1 Activated Sludge Biochemistry & Aeration Tank Mechanics 3.2 Process Control Parameters: F/M Ratio, MCRT & Sludge Wasting 3.3 Settleability Testing, Sludge Volume Index & Clarifier Blanket Dynamics 3.4 Activated Sludge Troubleshooting & Microscopic Bioindicators

4 Chapter 4: Alternative Biological Processes & Fixed-Film Systems

4.1 Extended Aeration Package Plants, Oxidation Ditches & SBR Cycles 4.2 Fixed-Film Systems: Trickling Filters & Rotating Biological Contactors (RBCs) 4.3 Waste Stabilization Ponds, Facultative Lagoons & Aerated Ponds

5 Chapter 5: Disinfection Systems & Effluent Management

5.1 Chlorination Chemistry, Feed Equipment & Chlorine Contact Basins 5.2 Dechlorination Systems, Sulfur Dioxide & Bisulfite Chemistry 5.3 Ultraviolet (UV) Disinfection Mechanics, Dosage & Effluent Standards

6 Chapter 6: Solids Handling, Digestion & Biosolids Management

6.1 Sludge Thickening: Gravity, DAF & Gravity Belt Thickeners 6.2 Aerobic & Anaerobic Digestion Principles & Operational Control 6.3 Dewatering Technologies: Belt Filter Presses, Centrifuges & Drying Beds 6.4 Biosolids Regulations, EPA 40 CFR Part 503 & Land Application

7 Chapter 7: Sampling Protocols, Laboratory Testing & Operator Math

7.1 Wastewater Sampling Methods, Representative Samples & Chain of Custody 7.2 Biochemical Oxygen Demand (BOD5/CBOD5) & Total Suspended Solids (TSS) Analysis 7.3 Routine Process Testing: Dissolved Oxygen, pH, Settleable Solids & Ammonia 7.4 Essential Operator Math: Flow Conversions, Detention Time, Loading Rates & Pounds Formula

8 Chapter 8: Safety, Collection Systems, Utility Operations & Regulations

8.1 Confined Space Entry, Atmospheric Testing & Hazardous Gas Safety 8.2 Chemical Safety: Chlorine Gas Cylinders, Hypochlorite & Hazard Communication 8.3 Collection Systems, Lift Stations, Inflow/Infiltration & Clean Water Act / NPDES Compliance

9 Chapter 9: Pumps, Motors, Drives & Plant Electrical Systems

9.1 Centrifugal Pumps: Types, Curves, Cavitation & Seal Maintenance 9.2 Positive Displacement Pumps: Progressive Cavity, Plunger, Diaphragm & Peristaltic 9.3 Motors, Motor Control Centers, Variable Frequency Drives & Electrical Safety

10 Chapter 10: Aeration, Mixing & Chemical Feed Equipment

10.1 Aeration Equipment: Blowers, Diffusers, Surface Aerators & Air Distribution 10.2 Mixers, Flash Mixing & Chemical Feed Systems

11 Chapter 11: Instrumentation, Online Analyzers, SCADA & Auxiliary Power

11.1 Field Instrumentation: Flow Measurement, Level Sensing & Pressure 11.2 Online Process Analyzers: Dissolved Oxygen, pH, ORP, Turbidity & Chlorine Residual 11.3 SCADA, Telemetry, Alarm Management, Security & Auxiliary Power

12 Chapter 12: Valves, Piping, Compressors & Ancillary Plant Equipment

12.1 Valves, Piping, Air Compressors, Conveyors, Hoists & Cranes

13 Chapter 13: Tertiary Filtration & Effluent Polishing

13.1 Tertiary Filtration Equipment: Granular Media, Disc & Cloth Filters 13.2 Filtration Process Control: Loading Rates, Headloss, Breakthrough & Backwash Triggers

14 Chapter 14: Activated Sludge Configurations & Biological Nutrient Removal

14.1 Activated Sludge Configurations: Conventional Plug Flow, Complete Mix, Step Feed & Contact Stabilization 14.2 Nutrient Removal: Nitrification, Denitrification & Anaerobic/Anoxic/Aerobic Zones

15 Chapter 15: Chemical Dosing Processes, Effluent Disposal & Solids Disposal

15.1 Chemical Dosing Processes: Coagulation, Flocculation, pH Adjustment & Dosage Calculations 15.2 Effluent Disposal: Surface Water Discharge & Rapid Infiltration Basins; Solids Disposal to Landfill

16 Chapter 16: Bacteriological Analyses, Chemical Analyses & Laboratory Quality Control

16.1 Bacteriological Analyses: Indicator Organisms, Membrane Filtration & Geometric Mean Reporting 16.2 Chemical Analyses & Laboratory Quality Control: COD, Nutrients, Metals, WET Testing & SOPs

17 Chapter 17: Safety Programs, Emergency Response, Security & Administrative Procedures

17.1 Lockout/Tagout, Machine Guarding, Fall Protection & PPE Programs 17.2 Emergency Response, Spill Control, Security & Vulnerability Assessments 17.3 Administrative Procedures: SOPs, O&M Reports, Discharge Monitoring Reports & Recordkeeping

17.3 Administrative Procedures: SOPs, O&M Reports, Discharge Monitoring Reports & Recordkeeping

Key Takeaways Explain This Topic AI

A standard operating procedure exists so that a task is performed the same way by every operator on every shift, and SOPs must be reviewed and updated whenever equipment, chemicals, methods, or regulations change.

Daily logs, shift turnover notes, and monthly operating reports form the operating history that reveals trends no single reading can show, and equipment run hours drive preventive maintenance scheduling.

The Discharge Monitoring Report is a self-monitoring report certified by a responsible official, and signing it certifies the accuracy of the data under penalty of law.

NPDES records including monitoring data, calibration records, and original strip chart or instrument records must be retained for at least three years, a period the regulatory authority may extend, while biosolids records under 40 CFR Part 503 are retained for five years.

Falsifying monitoring data or reports is a criminal offense under the Clean Water Act, and the correct response to a bad or missing result is to document and explain it rather than to alter or omit it.

Last updated: September 2026

17.3 Administrative Procedures: SOPs, O&M Reports, Discharge Monitoring Reports & Recordkeeping

Exam Focus: Six of the line items in the Security, Safety, and Administrative Procedures content area are administrative rather than safety-related: complete O&M reports, complete required regulatory reports, ensure compliance with applicable regulations, respond to customer service requests and complaints, adhere to SOPs, and establish and/or update SOPs. Candidates who study only safety are leaving marks on the table.

1. Standard Operating Procedures

A standard operating procedure (SOP) is a written, step-by-step description of how a specific task is performed at this plant. Its purpose is consistency : the same task performed the same way by every operator on every shift, on nights and weekends, by the new hire and by the twenty-year veteran.

A usable SOP contains:

  • Purpose and scope
  • Safety requirements and required PPE up front, before the steps
  • Equipment, materials, and reagents needed
  • Numbered step-by-step procedure
  • Acceptance criteria — what a correct result looks like
  • Troubleshooting for the common failure modes
  • Records to be completed
  • Revision number, effective date, author, and approver

Maintaining SOPs is itself a named exam topic. SOPs must be reviewed on a defined cycle and updated whenever equipment changes, a chemical changes, an analytical method is revised, a regulation changes, or an incident reveals a gap . Superseded versions must be removed from circulation so nobody works from an obsolete copy, and training records should show who has been trained on the current revision.

2. Operation and Maintenance Reports

Record Contents Why It Matters

Daily operating log Flows, process readings, lab results, equipment status, chemical usage, adjustments made and why, unusual observations The single most valuable document in the plant; it is the operating history

Shift turnover / round sheet What changed, what is in progress, what the next shift must watch Continuity across shifts; the point where most information is lost

Monthly operating report Summarized flows, loadings, removals, chemical usage, downtime Trend visibility and, in many states, a required submission

Annual report Yearly performance, capacity trends, major maintenance and capital needs Budgeting and long-range planning

Maintenance work orders Work requested, performed, parts used, labor hours Cost tracking and equipment history

Equipment history Every repair on every asset Reveals which units are consuming the budget and should be replaced

Run hours and starts Accumulated operating time Drives preventive maintenance intervals and reveals unbalanced duty rotation

Write logs so they are useful to someone else. "Adjusted RAS" is nearly worthless. "Increased RAS from 2.1 to 2.6 MGD at 1420 in response to clarifier blanket rising to 3.5 ft; blanket at 2.1 ft by 1800" tells the next operator what happened, why, and whether it worked.

Preventive versus corrective maintenance is a distinction worth stating plainly: preventive maintenance is scheduled work performed to prevent failure, corrective maintenance is repair after failure, and a plant whose maintenance is overwhelmingly corrective is a plant operating in a permanent state of surprise. Run hours and equipment history are what allow a shift from one to the other.

3. The Discharge Monitoring Report

The Discharge Monitoring Report (DMR) is the periodic report on which a permittee reports its own monitoring results against its permit limits.

It is self-monitoring : the permittee collects, analyzes, and reports its own data.

It is certified by a responsible official , who signs a statement affirming that the information was gathered under their direction and is, to the best of their knowledge, true, accurate, and complete , and acknowledging that there are significant penalties for submitting false information .

Most permittees now submit electronically through the NPDES electronic reporting system rather than on paper.

The DMR reports what the permit requires at the frequency the permit requires — missing a required sample is itself a violation, separate from any limit exceedance.

Averaging Conventions

Permits use specific averaging periods, and using the wrong one produces a wrong report:

  • Statistic Meaning
  • Daily maximum The highest single-day value in the period
  • 7-day (weekly) average Arithmetic average of results in a calendar week
  • 30-day (monthly) average Arithmetic average of results in a calendar month
  • Geometric mean Used for bacteriological parameters (Section 16.1)

Percent removal (Influent minus effluent) divided by influent, times 100 — typically a monthly average requirement of at least 85 percent for BOD5 and TSS under federal secondary treatment standards

  • Mass loading (lb/day) Flow in MGD times concentration in mg/L times 8.34
  • 4. Recordkeeping and Retention

NPDES records must be retained for at least three years from the date of the sample, measurement, report, or application. This includes all monitoring information : the date, exact place, and time of sampling; who performed the sampling; the analytical dates and methods; who performed the analyses; and the results — plus calibration and maintenance records and original strip chart or instrument recordings . The regulatory authority may extend the retention period.

Biosolids records under 40 CFR Part 503 are retained for five years , covering pathogen and vector attraction reduction compliance, metals concentrations, and land application site and loading data (Section 6.4).

Safety records carry their own retention requirements — training, confined space entry permits, exposure monitoring, and hearing conservation audiometric records.

Records must be legible, complete, and retrievable . A record that cannot be produced during an inspection is functionally a record that does not exist.

Never falsify, and never quietly omit. Knowingly falsifying or tampering with monitoring data or reports under the Clean Water Act is a criminal offense, not merely an administrative one, and it carries penalties for the individual as well as the utility. If a sample was missed, record that it was missed and why. If a result is invalid because an instrument was out of calibration, report it as invalid with the explanation attached. If a limit was exceeded, report the exceedance and the corrective action. Every one of those is a manageable problem; altering a record is a career-ending one.

5. Responding to Customer Service Requests and Complaints

Named directly in the Need-to-Know Criteria, and genuinely part of an operator's job.

Complaint Typical Cause Response

Odor Septic collection system, uncovered screenings or grit container, digester or thickener venting, biosolids handling, plant upset Log the complaint with date, time, location, and wind direction ; investigate the likely source; take corrective action; report back to the complainant

Sewer backup Blockage in the lateral or the main, grease, roots, structural failure, wet weather surcharge Respond promptly, determine whether the blockage is on the utility side or the private lateral, clear the utility portion, document, and follow up

Manhole overflow Blockage, inflow and infiltration, pump station failure Treat as an SSO — contain, clean up, sample, notify, and report per Section 17.2

Noise Blowers, generators, pumps, night hauling Investigate, mitigate where feasible, and communicate

Water quality concern in the receiving stream May or may not originate at the plant Investigate honestly, sample, and share results

The professional standard is the same in every case: log it, investigate it, act on it, close the loop with the person who called, and trend the complaints. A cluster of odor complaints from one neighborhood over several weeks is process information, not just a nuisance.

6. Assisting in Equipment Selection

The criteria list "Assist in the selection of equipment for use in wastewater processing," because operators hold information engineers do not: which pump models have actually survived in this service, which valve packs with rags, where access for maintenance is impossible, which instrument needs cleaning twice a week. Useful operator input covers maintainability and access, parts availability and standardization with existing units, energy consumption, reliability history at this plant, safety of routine servicing, and the training required — not just purchase price.