9.3 Lead & Copper Rule Revisions (LCRR)
ABC/WPI Water Distribution Operator Class I Certification Exam Exam
Track your progress as you read
Finished sections get a check mark.
1 Introduction & Exam Overview
1.1 Current Exam Facts 1.2 Certification, Eligibility & the WPI/ABC System 1.3 Study Plan & How to Use This Guide
2 Distribution Components — Pipes, Joints & Fittings
2.1 Mains & Service Lines 2.2 Pipe Materials (PVC, DI, CI, AC, HDPE, Copper, Steel) 2.3 Joints, Fittings & Thrust Restraint
3 Distribution Components — Valves, Hydrants, Storage & Wells
3.1 Valves (Gate, Butterfly, Check, PRV, Air Release, Blow-off) 3.2 Fire Hydrants 3.3 Storage Facilities (Ground, Elevated, Hydropneumatic) 3.4 Pumps & Pump Stations 3.5 Wells, Water Levels & Sanitary Condition
4 Meters, Backflow Devices, SCADA, Hydraulics & Demand
4.1 Meters & Metering (AMR/AMI) 4.2 Backflow Prevention Devices (Air Gap, RPZ, DCVA, PVB) 4.3 SCADA & Instrumentation 4.4 Distribution Hydraulics: Pressure, C-factor, Head Loss 4.5 System Demand, Water Production & Design Basics
5 Installation — Excavation, Bedding & Sewer Separation
5.1 Excavation Safety & Trenching (OSHA Subpart P) 5.2 Bedding, Backfill & Thrust Blocks 5.3 Separation from Sewer Mains
6 Installation — Pressure Testing & Disinfection
6.1 AWWA C600 Hydrostatic Pressure Testing 6.2 AWWA C651 Disinfection of New Mains 6.3 Service Line Installation, Tapping & Main Repairs
7 Operations & Maintenance
7.1 Valve Exercising & Hydrant Maintenance 7.2 Flushing & Unidirectional Flushing 7.3 Storage Facility Cleaning & Disinfection 7.4 Meter Reading & Underground Locating
8 Water Quality Monitoring & Lab Analysis
8.1 Disinfection Principles: Free vs Combined Chlorine, Breakpoint 8.2 Chemical Dosage & Feed Equipment 8.3 Sample Collection & Lab Analysis (Chlorine Residual, pH, Turbidity) 8.4 Lab Interpretation & Distribution Water Quality Problems
9 Regulations, Sampling & Public Notification
9.1 SDWA & Federal Drinking Water Regulations 9.2 Revised Total Coliform Rule (RTCR) 9.3 Lead & Copper Rule Revisions (LCRR) 9.4 Public Notification, CCR & Sampling Techniques
10 Safety, Security & Administrative Procedures
10.1 PPE, Safe Work Practices & Lockout/Tagout 10.2 Traffic Control (MUTCD) & Confined Space Entry 10.3 Underground Locating (811) & APWA Color Codes 10.4 Cross-Connection Control Program & Hazard Levels 10.5 System Maps, Schematics, Plans & Asset Management
11 Security, Records, Math Review & Final Readiness
11.1 Emergency Response, Facility Security & Water Loss Control 11.2 Recordkeeping, SOPs & Customer Inquiries 11.3 Operator Math: Flow, Pressure, Head & Pipe Volume 11.4 Operator Math: Chemical Feed & Chlorine Dose 11.5 Full-Length Practice & Test-Day Strategy
9.3 Lead & Copper Rule Revisions (LCRR)
Key Takeaways Explain This Topic AI
The Lead and Copper Rule (LCR) is a treatment-technique rule: compliance is judged at the 90th percentile of tap samples, with a lead action level of 0.015 mg/L and a copper action level of 1.3 mg/L.
Tier 1 sampling sites are lead service lines (LSLs) or copper plumbing with lead solder installed after 1982, the window closed by the 1986 SDWA lead-solder ban that took effect in 1988.
Samples are first-draw 1-liter taps after at least 6 hours of stagnation, taken at high-risk customer taps — not at the main.
An action-level exceedance triggers corrosion-control treatment, source-water monitoring, public education, and (if needed) lead service line replacement; LCRR added an LSL inventory due October 2024 and faster LSL replacement.
EPA's Lead and Copper Rule Improvements (LCRI) is in development and may lower the lead action level to 10 ppb and strengthen LSL removal — present current LCRR requirements as the operative rule.
Last updated: August 2026
9.3 Lead & Copper Rule Revisions (LCRR)
Quick Answer: The Lead and Copper Rule (LCR) is a treatment-technique rule — there is no MCL for lead at the tap. Instead, systems sample at high-risk customer taps (Tier 1 sites) and judge compliance by the 90th-percentile value: lead action level = 0.015 mg/L (15 ppb) , copper action level = 1.3 mg/L . The Lead and Copper Rule Revisions (LCRR) , with compliance beginning January 2022 , added a lead service line (LSL) inventory (due October 2024) and faster LSL replacement. EPA's Lead and Copper Rule Improvements (LCRI) is in development and may lower the lead action level to 10 ppb ; LCRR is the current operative rule.
Why a Treatment Technique Instead of an MCL
Lead in drinking water rarely comes from the source or the treatment plant — it comes from materials in the plumbing and service line : lead service lines, lead solder, brass fittings, and galvanized pipe attached to a lead service line. Because the same water can be safe at the plant and unsafe at the tap, EPA regulates lead and copper with a treatment technique : corrosion-control treatment that keeps water non-aggressive, plus tap sampling at the highest-risk sites.
Action Levels and the 90th Percentile
The action levels are not MCLs — they are thresholds that trigger additional treatment and actions:
- Contaminant Action Level What It Means
- Lead 0.015 mg/L (15 ppb) Exceeded if the 90th-percentile tap sample is above this in >10% of sites
- Copper 1.3 mg/L Same 90th-percentile calculation
The 90th percentile is calculated by ranking results from lowest to highest and picking the value at the 90th-percentile position. If a system samples 10 sites, the 9th-highest value is the 90th-percentile result. If that value exceeds the action level, the system has an action-level exceedance — not an MCL violation.
Tier 1 Sampling Sites
Samples must come from the highest-risk taps. Tier 1 sites are, in priority order:
Lead service lines (LSLs) — single-family residences with a known or presumed lead service line.
Lead-soldered copper plumbing installed after 1982 — the high-risk lead-solder window that ended when the 1988 federal lead-solder ban took effect (mandated by the 1986 SDWA Amendments).
If insufficient Tier 1 sites exist, the system drops to Tier 2 (multi-family with LSLs or lead solder) or Tier 3 (single-family with copper pipe and lead-solder sites of any age).
This is why the post-1982 window matters: the LCR defines lead-soldered copper installed after 1982 as high-risk.
Sampling Protocol — First-Draw, 1 Liter, 6-Hour Stagnation
Each tap sample is a first-draw 1-liter sample collected after the water has stood in the plumbing for at least 6 hours (overnight is typical). The tap is not flushed before sampling. The sample represents what a customer would drink first thing in the morning after stagnation — the worst-case exposure for lead leaching.
Key protocol points:
Use a cold-water kitchen or bathroom tap used for consumption.
Do not remove or clean the aerator before sampling unless the system's protocol requires it.
Do not sample through a point-of-use filter.
Sample bottles contain nitric acid preservative.
Record the stagnation time on the chain-of-custody.
This is the opposite of coliform sampling, where you flush the tap first.
What an Action-Level Exceedance Triggers
If the 90th-percentile lead value exceeds 0.015 mg/L (or copper exceeds 1.3 mg/L), the system must:
Optimize corrosion-control treatment (or install it if none exists) — typically by adjusting pH and alkalinity or adding an orthophosphate inhibitor.
Conduct source-water monitoring for lead and copper at the entry point to the distribution system.
Begin or accelerate lead service line replacement at a rate of 7% per year under the original LCR; LCRR tightens this.
Deliver public education to consumers about lead sources, health effects, and tap-flushing.
Public education for lead is delivered annually until the system returns below the action level for two consecutive 6-month periods.
LCRR and LCRI Status (2026)
LCRR (compliance January 2022) — the current operative rule. It requires systems to inventory lead service lines (initial inventory due October 16, 2024 ), notify customers served by LSLs, and replace LSLs faster when action levels are exceeded.
LCRI (Lead and Copper Rule Improvements) — under development by EPA. Proposals include lowering the lead action level to 10 ppb , requiring LSL replacement on a firmer schedule, and strengthening public education. Treat the LCRR requirements as the operative rule on the exam unless a question explicitly asks about pending proposals.
Distribution Operator Role
Help select and maintain Tier 1 sampling sites and update the site inventory.
Deliver sample bottles to residents and explain the first-draw, 6-hour stagnation protocol.
Collect the bottles, complete the chain-of-custody , and ship to the lab within holding times.
Track results and flag a 90th-percentile exceedance to the state and the public education lead.
Maintain the LSL inventory records for your system.
Exam Tip
Three numbers and one protocol dominate LCR questions: 0.015 mg/L lead, 1.3 mg/L copper, 6-hour first-draw . Remember the action level is mg/L (15 ppb is the same as 0.015 mg/L). And remember: an exceedance is not an MCL violation — it triggers treatment, monitoring, and education.