Study guide

Radioactive Waste Disposal & US DOT Transport Regulations

ABMP Medical Health Physics Exam

Track your progress as you read

Finished sections get a check mark.

1 Radiation Detection Instrumentation

Ionization Chambers & Geiger-Mueller Counters Scintillation Detectors, Photomultipliers & Gamma Spectroscopy Liquid Scintillation & Gamma Counting Systems: Well Counters & Thyroid Probes Personnel Dosimeters & Electronic Radiation Monitors Neutron Detection & Emergency Field Instrumentation

2 Laboratory Design & Contamination Control

Radiopharmaceutical Laboratory Design & USP <825> Standards Ventilation Systems, Fume Hoods & Contamination Engineering

3 Radiation Protection Standards & Dose Limits

Federal Regulatory Framework & Advisory Authorities Federal Guidance Documents: NRC Regulatory Guides, NUREGs, EPA & FDA Guidance Occupational & Public Dose Limits and ALARA Principles Radiobiological Basis of Limits & Risk Communication

4 Medical Licensing, Written Directives & Security

NRC Form 313 Authorizations, RSO Responsibilities & Written Directives Medical Event Reporting & 10 CFR 37 Category 1/2 Source Security

5 Diagnostic Radiology Structural Shielding

Diagnostic Shielding Methodology: NCRP Report 147 Modality Shielding: Radiography, Fluoroscopy & CT Facilities

6 Megavoltage Therapy Vault & Facility Shielding

Megavoltage Vault Primary & Secondary Barriers: NCRP Report 151 Therapy Maze Design, Photoneutrons & Shielded Doors PET/CT & Nuclear Medicine Facility Shielding (AAPM TG-108)

7 Radiation Oncology Quality Management & Safety

External Beam QA & Dosimetry Calibration Protocols Brachytherapy Safety, Inventory Control & Leak Testing

8 Radiation Oncology Emergency Procedures & TPS QA

Treatment Planning System (TPS) QA & Patient Verification Radiation Oncology Emergency Procedures: HDR Stuck Sources & Linac Failures Medical Events, Incident Investigation & Joint Commission Requirements in Radiation Oncology

9 Diagnostic Imaging Safety & Fluoroscopy Management

Diagnostic X-ray & Fluoroscopy Safety Interventional Fluoroscopy Dose Management & NCRP Report 168

10 CT Optimization, MQSA & Diagnostic Accreditation

Computed Tomography Dosimetry & Protocol Optimization Mammography Quality Standards Act (MQSA) & Mammography Physics Diagnostic Imaging Quality Management, Accreditation & Regulatory Oversight

11 Nuclear Medicine Radiopharmacy & Unsealed Therapy

Radiopharmaceutical QC & Radionuclide Calibrators Unsealed Source Therapy: I-131 Protocols & Patient Release Criteria

12 Targeted Radionuclide Therapy, Decontamination & RAM Transport

Targeted Radionuclide Therapies: Lu-177, Ra-223, Y-90 & Radioimmunotherapy Contamination Surveys, Spill Response & Personnel Decontamination Radioactive Waste Disposal & US DOT Transport Regulations

13 Radiobiology & Radiation Risk Assessment

Cellular Radiobiology, DNA Damage & Dose-Response Models Prenatal Radiation Risks & Population Exposures

14 Non-Ionizing Radiation Safety: Lasers & MRI

Healthcare Laser Safety: ANSI Z136.1 & Z136.3 MRI Safety, Facility Design & Bioeffects

Radioactive Waste Disposal & US DOT Transport Regulations

Key Takeaways Explain This Topic AI

Under 10 CFR 35.92, waste with a half-life of 120 days or less may be held for decay and disposed of when a surface survey on the most sensitive scale with no shielding shows it is indistinguishable from background and radiation labels are removed; the rule sets no fixed holding time.

Disposal into public sanitary sewers under 10 CFR 20.2003 mandates that material be readily water-soluble, subject to annual facility limits of 5 Ci for H-3, 1 Ci for C-14, and 1 Ci for all other radionuclides combined; patient excreta is completely exempt under 10 CFR 20.2003(b).

DOT radioactive packaging is categorized by accident survivability: Excepted packages for limited quantities, Type A packages tested for normal transport conditions (water spray, 1.2 m drop, compression, penetration) up to A1/A2 limits, and Type B packages tested for severe hypothetical accidents (9 m drop, puncture, 800°C fire, immersion).

DOT warning labels (White-I, Yellow-II, Yellow-III) are determined by surface dose rate and Transport Index (TI, dose rate at 1 meter in mrem/hr); any package classified as Yellow-III (TI > 1.0 or surface > 50 mrem/hr) requires vehicle placarding on all four exterior sides.

Under 10 CFR 20.1906, labeled packages are monitored within 3 hours of receipt (working hours); removable contamination above the DOT limit of 240 dpm/cm² (4 Bq/cm²) for beta-gamma emitters, or radiation above package limits, requires immediate notification of the carrier and NRC.

Last updated: October 2026

Radioactive Waste Disposal & US DOT Transport Regulations

The generation, storage, disposal, and highway transportation of unsealed radioactive materials are governed by an interlocking matrix of federal regulations promulgated by the Nuclear Regulatory Commission (NRC, Title 10 CFR Parts 20, 35, and 71) and the Department of Transportation (DOT, Title 49 CFR Parts 171–178). A medical health physicist must maintain comprehensive operational oversight of waste disposition pathways—principally decay-in-storage, sanitary sewer discharge, and commercial burial—while enforcing rigorous compliance with hazardous material packaging, surface labeling, transport indexing, and package receipt monitoring.

Radioactive Waste Disposal Pathways (10 CFR Part 20 Subpart K & 10 CFR 35.92)

Licensees must dispose of radioactive waste only by authorized pathways established under 10 CFR Part 20 Subpart K ( § § 20.2001 – 20.2008 \S\S\,20.2001\text{--}20.2008 §§ 20.2001 – 20.2008 ) or specific medical authorizations in 10 CFR 35.92 . RADIOACTIVE WASTE STREAM

  • |
  • +---------------------+---------------------+
  • | |
  • Physical Half-Life Physical Half-Life
  • T_1/2 <= 120 Days T_1/2 > 120 Days
  • | |
  • v v
  • [ DECAY-IN-STORAGE (DIS) ] [ LONG-LIVED DISPOSAL ]
  • (10 CFR 35.92 Authorization) |
  • | +-----------------+-----------------+
  • Hold for decay | |
  • | Water Soluble? Solid Form
  • v | |
  • SURVEY AT CONTAINER SURFACE v v
  • Remove all shielding [ SEWER RELEASE ] [ LLRW BURIAL ]
  • Low-background area (10 CFR 20.2003) (10 CFR Part 61)
  • Sensitive GM / NaI probe - Soluble in water - Class A, B, C
  • | - Monthly avg limits - Licensed broker
  • Indistinguishable from Bkg? - Annual caps: - Manifest 540/541
  • | * 5 Ci H-3
  • +--------+--------+ * 1 Ci C-14
  • | | * 1 Ci combined others
  • YES NO (Patient excreta EXEMPT)
  • | |
  • v v
  • DEFACE LABELS RETURN TO DIS
  • |
  • v
  • MUNICIPAL /
  • BIOHAZARD TRASH
  • 1. Decay-in-Storage (DIS) under 10 CFR 35.92

Decay-in-Storage is the primary waste management strategy utilized in hospital radiopharmacies and nuclear medicine clinics. It allows short-lived radionuclides to decay naturally to non-detectable levels on-site, entirely circumventing the exorbitant costs and liabilities of commercial low-level radioactive waste (LLRW) disposal.

Regulatory Prerequisites for DIS Clearance

Under 10 CFR 35.92, a licensee may hold byproduct material for decay-in-storage and subsequently dispose of it in ordinary municipal or biohazard trash without regard to its radioactivity if and only if all of the following conditions are met:

Half-Life Limitation : The radionuclide held has a physical half-life of T 1 / 2 ≤ 120 days T_{1/2} \le 120\text{ days} T 1/2 ​ ≤ 120 days . Radionuclides exceeding this threshold (e.g., 57 Co ^{57}\text{Co} 57 Co with T 1 / 2 = 271.8 days T_{1/2} = 271.8\text{ days} T 1/2 ​ = 271.8 days ; 68 Ge ^{68}\text{Ge} 68 Ge with T 1 / 2 = 270.9 days T_{1/2} = 270.9\text{ days} T 1/2 ​ = 270.9 days ; 137 Cs ^{137}\text{Cs} 137 Cs with T 1 / 2 = 30.17 years T_{1/2} = 30.17\text{ years} T 1/2 ​ = 30.17 years ) are legally prohibited from DIS and must be transferred to a licensed recipient.

Holding Time : The current rule sets no minimum holding period ; the former 10-half-life requirement was removed in the 2002 revision of Part 35. Many programs still use about 10 half-lives as a planning figure, because the activity then falls by 2 10 = 1,024 2^{10} = 1{,}024 2 10 = 1 , 024 :

A ( t ) = A 0 ( 1 2 ) 10 = A 0 1,024 ≈ 9.77 × 10 − 4 × A 0 A(t) = A_0 \left(\frac{1}{2}\right)^{10} = \frac{A_0}{1{,}024} \approx 9.77 \times 10^{-4} \times A_0 A ( t ) = A 0 ​ ( 2 1 ​ ) 10 = 1 , 024 A 0 ​ ​ ≈ 9.77 × 1 0 − 4 × A 0 ​

but release is governed by the survey, not by the elapsed time.

Radiation Survey Verification : Prior to release, the waste must be surveyed at the container surface with a sensitive radiation detection survey meter (typically an end-window GM probe or a low-energy NaI scintillator) set on its most sensitive scale . The survey must confirm that the radiation exposure rate cannot be distinguished from ambient background .

Survey Protocol : The survey is done in a low-background area with no interposed shielding (for example, bags are taken out of lead-lined containers before they are surveyed).

Removal of Radiation Labels : All radiation labels are removed or obliterated before disposal, except labels on materials that are inside containers and will be managed as biomedical waste after release (35.92(a)(2)).

Recordkeeping : Under 35.2092, each disposal record is kept for 3 years and includes the date of disposal, the survey instrument used, the background radiation level, the radiation level measured at the surface of each waste container, and the name of the individual who performed the survey.

2. Sanitary Sewer Disposal (10 CFR 20.2003)

Licensees may discharge liquid radioactive waste into a public sanitary sewerage system only if the criteria of 10 CFR 20.2003 are fulfilled:

Solubility Requirement : The material must be readily soluble in water , or biological material that is readily dispersible in water. Discharging insoluble radioactive colloids, labeled resin micro-beads ( 90 Y ^{90}\text{Y} 90 Y microspheres), or lipid suspensions into sinks is a violation of the rule.

Concentration Thresholds : The monthly average concentration of radioactivity released into the sewer must not exceed the concentration values specified in 10 CFR Part 20, Appendix B, Table 3 ( Releases to Sewers ).

Annual Facility Quantity Caps : The total quantity of unsealed radioactive material released into the sanitary sewer by the entire facility in any single calendar year must not exceed:

5.0 Curies 5.0\text{ Curies} 5.0 Curies ( 185 GBq 185\text{ GBq} 185 GBq ) of Hydrogen-3 ( 3 H ^{3}\text{H} 3 H )

  • 1.0 Curie 1.0\text{ Curie} 1.0 Curie ( 37 GBq 37\text{ GBq} 37 GBq ) of Carbon-14 ( 14 C ^{14}\text{C} 14 C )
  • 1.0 Curie 1.0\text{ Curie} 1.0 Curie ( 37 GBq 37\text{ GBq} 37 GBq ) of all other radionuclides combined
  • The Patient Excreta Exemption (10 CFR 20.2003(b))

Under 10 CFR 20.2003(b) , excreta (urine and feces) from individuals who have been administered radioactive materials for medical diagnosis or therapy is completely exempt from all concentration and annual total activity limitations. Patients treated with high therapeutic doses of 131 I ^{131}\text{I} 131 I sodium iodide ( > 150 mCi > 150\text{ mCi} > 150 mCi ) or 177 Lu ^{177}\text{Lu} 177 Lu -Dotatate ( 200 mCi 200\text{ mCi} 200 mCi ) may use standard hospital plumbing facilities without requiring radioactive delay-and-decay retention tanks, unless specifically mandated by local municipal wastewater authorities.

3. Commercial Low-Level Radioactive Waste (LLRW) & Incineration

Waste containing radionuclides with half-lives exceeding 120 days 120\text{ days} 120 days (e.g., long-lived sealed calibration sources: 137 Cs ^{137}\text{Cs} 137 Cs , 60 Co ^{60}\text{Co} 60 Co , 226 Ra ^{226}\text{Ra} 226 Ra , 68 Ge / 68 Ga ^{68}\text{Ge}/^{68}\text{Ga} 68 Ge / 68 Ga generators) cannot be held for decay-in-storage.

Classification under 10 CFR Part 61 : Commercial LLRW is categorized into Class A (least hazardous, decays to benign levels within 100 years), Class B, Class C (requires structural stability and intrusion barriers for 500 years), and Greater-Than-Class-C (GTCC, federal repository required). Most institutional medical LLRW is Class A.

Transfer and Manifesting : Waste must be packaged in certified DOT containers (e.g., 55-gallon steel drums) and transferred to an authorized radioactive waste broker or disposal site (e.g., Barnwell, SC; Clive, UT; or WCS, TX). Transfers require execution of NRC Form 540 ( Uniform Low-Level Radioactive Waste Manifest - Shipping Paper ) and NRC Form 541 ( Container and Waste Description ).

Incineration (10 CFR 20.2004) : On-site thermal incineration of radioactive waste (including animal carcasses contaminated with 14 C ^{14}\text{C} 14 C or 3 H ^{3}\text{H} 3 H ) is strictly prohibited unless explicitly approved in advance by the NRC or Agreement State via license amendment.

US DOT Hazardous Materials Transport Regulations (Title 49 CFR Parts 171–178 & 10 CFR 71)

Transportation of radioactive materials (Class 7 Hazardous Materials) over public thoroughfares is governed by the Department of Transportation under Title 49 CFR Parts 171 through 178, in regulatory harmonization with NRC 10 CFR Part 71 and International Atomic Energy Agency (IAEA) SSR-6 standards.

DOT Packaging Hierarchy: Excepted, Type A, and Type B

DOT packaging standards follow a graded-risk philosophy: packaging integrity must be commensurate with the potential radiological hazard of the package contents.

Packaging Type Regulatory Threshold Mechanical Integrity Standard Mandatory Qualification Testing (49 CFR 173.465) Typical Medical Contents

Excepted Package Limited quantity (49 CFR 173.425 Table 4): solids 10 − 3 A 1 10^{-3} A_1 1 0 − 3 A 1 ​ (special form) or 10 − 3 A 2 10^{-3} A_2 1 0 − 3 A 2 ​ ; liquids 10 − 4 A 2 10^{-4} A_2 1 0 − 4 A 2 ​ ; gases 10 − 3 A 1 10^{-3} A_1 1 0 − 3 A 1 ​ or A 2 A_2 A 2 ​ (tritium 2 × 10 − 2 A 2 2 \times 10^{-2} A_2 2 × 1 0 − 2 A 2 ​ ); also empty packaging and certain instruments Strong, tight packaging that retains contents in routine transport; surface radiation not above 0.5 mrem/h 0.5\text{ mrem/h} 0.5 mrem/h General packaging requirements Empty radiopharmaceutical pigs; small check sources; RIA kits

Type A Package Activity > Excepted > \text{Excepted} > Excepted up to ≤ A 1 \le A_1 ≤ A 1 ​ (special form) or ≤ A 2 \le A_2 ≤ A 2 ​ (normal form) Must withstand Normal Conditions of Transport (NCOT) without release or loss of shielding Water spray, Free drop ( 1.2 m 1.2\text{ m} 1.2 m ), Compression ( 5 × 5\times 5 × weight), Penetration bar ( 6 kg 6\text{ kg} 6 kg ) Standard nuclear medicine unit doses ( 99 m Tc ^{99\text{m}}\text{Tc} 99 m Tc , 18 F ^{18}\text{F} 18 F , 131 I ^{131}\text{I} 131 I , 177 Lu ^{177}\text{Lu} 177 Lu , 90 Y ^{90}\text{Y} 90 Y )

Type B Package Activity > A 1 > A_1 > A 1 ​ or > A 2 > A_2 > A 2 ​ (high-activity sources) Must withstand Hypothetical Accident Conditions (HAC) with minimal release 9 m 9\text{ m} 9 m drop onto unyielding target; Puncture; 800 ∘ C 800^\circ\text{C} 80 0 ∘ C fire ( 30 min 30\text{ min} 30 min ); Immersion Industrial radiography cameras; 192 Ir ^{192}\text{Ir} 192 Ir HDR brachytherapy reloaders; 60 Co ^{60}\text{Co} 60 Co teletherapy

The A 1 A_1 A 1 ​ and A 2 A_2 A 2 ​ System

A 1 A_1 A 1 ​ Value : The maximum activity of special form radioactive material permitted in a Type A package. Special form denotes an indispersible solid radioactive material or a sealed capsule that meets stringent thermal and impact tests (49 CFR 173.469).

A 2 A_2 A 2 ​ Value : The maximum activity of normal form radioactive material permitted in a Type A package. Normal form denotes all other physical states, including unsealed liquids, powders, and gases typical of medical radiopharmaceuticals. Because unsealed normal form material is vulnerable to dispersion and aerosolization in a crash, A 2 A_2 A 2 ​ values are substantially lower than A 1 A_1 A 1 ​ values (e.g., for 131 I ^{131}\text{I} 131 I , A 1 = 3 TBq A_1 = 3\text{ TBq} A 1 ​ = 3 TBq (about 81 Ci 81\text{ Ci} 81 Ci ) and A 2 = 0.7 TBq A_2 = 0.7\text{ TBq} A 2 ​ = 0.7 TBq (about 18.9 Ci 18.9\text{ Ci} 18.9 Ci )).

Mandatory Type A Engineering Qualification Tests (49 CFR 173.465)

A prototype Type A package design must be subjected to four sequential physical performance tests simulating Normal Conditions of Transport (NCOT) without loss or dispersal of contents and with no increase in maximum surface radiation level exceeding 20 % 20\% 20% :

Water Spray Test : Simulates a heavy rainstorm of 2.0 inches 2.0\text{ inches} 2.0 inches ( 50 mm 50\text{ mm} 50 mm ) per hour for at least 1.0 hour 1.0\text{ hour} 1.0 hour .

Free Drop Test : The package is dropped through free air onto a flat, horizontal, unyielding steel/concrete target from a height of 1.2 meters 1.2\text{ meters} 1.2 meters ( 4.0 feet 4.0\text{ feet} 4.0 feet ) . (For packages weighing > 11 , 000 lbs > 11,000\text{ lbs} > 11 , 000 lbs , drop height scales down to 0.3 – 0.9 m 0.3\text{--}0.9\text{ m} 0.3 – 0.9 m ). Water-spray conditioning must immediately precede the drop.

Compression (Stacking) Test : A compressive load equal to the greater of 5 × 5\times 5 × the total package mass or 13 kPa 13\text{ kPa} 13 kPa ( 1.9 psi 1.9\text{ psi} 1.9 psi ) multiplied by the vertically projected area of the package is applied continuously across the top surface for at least 24 hours 24\text{ hours} 24 hours .

Penetration Test : A solid cylindrical steel bar with a hemispherical end, weighing 6.0 kg 6.0\text{ kg} 6.0 kg ( 13.2 lbs 13.2\text{ lbs} 13.2 lbs ) and measuring 3.2 cm 3.2\text{ cm} 3.2 cm in diameter, is dropped vertically from a height of 1.0 meter 1.0\text{ meter} 1.0 meter ( 3.3 feet 3.3\text{ feet} 3.3 feet ) onto the most vulnerable exterior point of the package.

DOT Radiation Warning Labels, Transport Index & Placarding

Radioactive packages transported on public roads must display standardized diamond-shaped hazard warning labels on two opposite exterior sides (49 CFR 172.403). The required label category is governed by two independent metrics: the maximum surface radiation dose rate and the Transport Index (TI) .

The Transport Index (TI) Defined

The Transport Index is a dimensionless number assigned to a package to provide physical control over radiation exposure and critical spacing during transport. Under 49 CFR 173.403:

TI = Maximum dose equivalent rate in m r e m / h r at 1.0 meter from the external package surface \text{TI} = \text{Maximum dose equivalent rate in } \mathbf{mrem/hr} \text{ at } \mathbf{1.0\text{ meter}} \text{ from the external package surface} TI = Maximum dose equivalent rate in mrem/hr at 1.0 meter from the external package surface

TI = H ˙ 1 m ( μ Sv/hr ) 10 \text{TI} = \frac{\dot{H}_{1\text{m}} \,(\mu\text{Sv/hr})}{10} TI = 10 H ˙ 1 m ​ ( μ Sv/hr ) ​

The calculated TI must always be rounded up to the next higher tenth ( 0.1 0.1 0.1 ) . For non-fissile packages, if the measured dose rate at 1.0 meter 1.0\text{ meter} 1.0 meter does not exceed 0.05 mrem/hr 0.05\text{ mrem/hr} 0.05 mrem/hr ( 0.5 μ Sv/hr 0.5\,\mu\text{Sv/hr} 0.5 μ Sv/hr ), the Transport Index is assigned as TI = 0 \text{TI} = 0 TI = 0 .

DOT Radiation Warning Label Categories

Label Category Trefoil & Bar Color Maximum External Surface Dose Rate Maximum Dose Rate at 1.0 Meter (Transport Index) Shipper Vehicle Placarding Required?

RADIOACTIVE WHITE-I Black trefoil; One red vertical bar ; White background ≤ 0.5 mrem/hr \mathbf{\le 0.5\text{ mrem/hr}} ≤ 0.5 mrem/hr ( 0.005 mSv/hr 0.005\text{ mSv/hr} 0.005 mSv/hr ) Indistinguishable from background ( TI = 0 \mathbf{\text{TI} = 0} TI = 0 ) NO

RADIOACTIVE YELLOW-II Black trefoil; Two red vertical bars ; Yellow upper half > 0.5 mrem/hr to ≤ 50.0 mrem/hr \mathbf{> 0.5\text{ mrem/hr} \text{ to } \le 50.0\text{ mrem/hr}} > 0.5 mrem/hr to ≤ 50.0 mrem/hr ( 0.5 mSv/hr 0.5\text{ mSv/hr} 0.5 mSv/hr ) TI > 0 to ≤ 1.0 \mathbf{\text{TI} > 0 \text{ to } \le 1.0} TI > 0 to ≤ 1.0 (Dose rate at 1 m ≤ 1.0 mrem/hr 1\text{m} \le 1.0\text{ mrem/hr} 1 m ≤ 1.0 mrem/hr ) NO

RADIOACTIVE YELLOW-III Black trefoil; Three red vertical bars ; Yellow upper half > 50.0 mrem/hr to ≤ 200.0 mrem/hr \mathbf{> 50.0\text{ mrem/hr} \text{ to } \le 200.0\text{ mrem/hr}} > 50.0 mrem/hr to ≤ 200.0 mrem/hr ( 2.0 mSv/hr 2.0\text{ mSv/hr} 2.0 mSv/hr ) TI > 1.0 to ≤ 10.0 \mathbf{\text{TI} > 1.0 \text{ to } \le 10.0} TI > 1.0 to ≤ 10.0 (Dose rate at 1 m > 1.0 to ≤ 10 mrem/hr 1\text{m} > 1.0 \text{ to } \le 10\text{ mrem/hr} 1 m > 1.0 to ≤ 10 mrem/hr ) YES (Diamond "RADIOACTIVE" placard on all 4 sides of vehicle)

YELLOW-III (Exclusive Use Vehicle) Three red vertical bars; Yellow upper half > 200.0 mrem/hr to ≤ 1 , 000.0 mrem/hr \mathbf{> 200.0\text{ mrem/hr} \text{ to } \le 1,000.0\text{ mrem/hr}} > 200.0 mrem/hr to ≤ 1 , 000.0 mrem/hr ( 10.0 mSv/hr 10.0\text{ mSv/hr} 10.0 mSv/hr ) TI > 10.0 \text{TI} > 10.0 TI > 10.0 permitted (vehicle cab limit ≤ 2.0 mrem/hr \le 2.0\text{ mrem/hr} ≤ 2.0 mrem/hr ) YES (Placarded on all 4 sides; exclusive-use controls)

Categorization Rule : If the surface dose rate and the 1-meter dose rate dictate different label categories, the shipper must always assign the higher (more restrictive) label category .

Package Label Information Entries

Each label must be permanently completed with:

Contents : Name of the radionuclide(s) (e.g., " 99 m Tc ^{99\text{m}}\text{Tc} 99 m Tc ", " 131 I ^{131}\text{I} 131 I ", " 177 Lu ^{177}\text{Lu} 177 Lu ").

Activity : Maximum activity in SI units (Becquerels, e.g., " 37 GBq 37\text{ GBq} 37 GBq "). Traditional units (Curies/mCi) may appear in parentheses alongside SI units.

Transport Index : The calculated TI (mandatory on Yellow-II and Yellow-III labels; left blank on White-I labels).

Vehicle Placarding Rules (49 CFR 172.504)

A motor vehicle transport carrier must display square-on-point "RADIOACTIVE" placards on all four exterior sides (front, rear, left, right) whenever carrying:

  • Any package bearing a Radioactive Yellow-III label;
  • Any exclusive-use shipment of Low Specific Activity (LSA) material or Surface Contaminated Objects (SCO);

A highway route controlled quantity (HRCQ) of radioactive material.

Package Receipt Monitoring & Contamination Limits (10 CFR 20.1906)

Under 10 CFR 20.1906 , medical institutions receiving labeled radioactive packages must perform timely physical and radiological receipt inspections.

The Mandatory 3-Hour Receipt Rule

Under 20.1906(b), the licensee must monitor the external surfaces of a labeled package (White I, Yellow II, or Yellow III) for radioactive contamination , unless it contains only gas or special-form material, and must monitor radiation levels of a labeled package containing more than a Type A quantity. Monitoring is done as soon as practical, but:

No later than 3 hours after receipt if received during normal working hours; or

No later than 3 hours from the beginning of the next working day if received after working hours.

Receipt Inspection Sequence

Visual Package Integrity Inspection : Check the package for external signs of physical damage, crushed corners, puncture wounds, moisture, wet spots, or compromised security seals. If damaged or leaking, halt processing immediately, isolate the parcel, and notify the RSO.

External Radiation Survey : Using a calibrated, energy-compensated survey meter (e.g., ion chamber or calibrated GM), measure the maximum radiation dose rate:

In contact with the external surface of the package;

At 1.0 meter 1.0\text{ meter} 1.0 meter from the external surface (verifying the stated Transport Index).

Wipe Test for Removable Contamination : Perform a wipe survey by rubbing an absorbent filter paper across an area of 300 cm 2 300\text{ cm}^2 300 cm 2 (or over the entire package surface if < 300 cm 2 < 300\text{ cm}^2 < 300 cm 2 ). Count the wipe in a calibrated well counter or liquid scintillation counter to calculate removable activity per unit area.

Regulatory Contamination Limits (49 CFR 173.443 Table 9)

Non-fixed contamination is determined by wiping 300 cm 2 300\text{ cm}^2 300 cm 2 with moderate pressure; the activity on the wipe is divided by the area and by the wipe efficiency (actual, or an assumed 0.10 0.10 0.10 ). It must not exceed:

Beta and gamma emitters and low-toxicity alpha emitters : 4 Bq/cm 2 4\text{ Bq/cm}^2 4 Bq/cm 2 ( 10 − 4 μ Ci/cm 2 10^{-4}\ \mu\text{Ci/cm}^2 1 0 − 4 μ Ci/cm 2 , 240 dpm/cm 2 240\text{ dpm/cm}^2 240 dpm/cm 2 )

All other alpha emitters : 0.4 Bq/cm 2 0.4\text{ Bq/cm}^2 0.4 Bq/cm 2 ( 10 − 5 μ Ci/cm 2 10^{-5}\ \mu\text{Ci/cm}^2 1 0 − 5 μ Ci/cm 2 , 24 dpm/cm 2 24\text{ dpm/cm}^2 24 dpm/cm 2 )

(Older editions used 22 and 2.2 dpm/cm² with no wipe-efficiency correction; the current table and the efficiency correction replaced them. Exclusive-use shipments may reach ten times these levels during transport.)

Mandatory Regulatory Reporting Triggers (10 CFR 20.1906(d))

The licensee must immediately notify by telephone the final delivering carrier and the NRC Operations Center (or Agreement State regulatory authority) if:

Removable external surface contamination exceeds the limits referenced in 10 CFR 71.87(i) (the DOT Table 9 values of 240 dpm/cm 2 240\text{ dpm/cm}^2 240 dpm/cm 2 for beta-gamma and low-toxicity alpha emitters, 24 dpm/cm 2 24\text{ dpm/cm}^2 24 dpm/cm 2 for other alpha emitters); OR

External radiation levels exceed the limits of 10 CFR 71.47, for a non-exclusive-use package 2 mSv/h 2\text{ mSv/h} 2 mSv/h ( 200 mrem/h 200\text{ mrem/h} 200 mrem/h ) at any point on the surface or a transport index above 10 .