Study guide

1.1 The Alaska Certificate of Fitness System

Alaska Journeyman Electrician Study Guide Exam

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: Alaska Certificates of Fitness, Law & Exam Logistics

1.1 The Alaska Certificate of Fitness System 1.2 Journeyman Eligibility: 8,000 Hours and How Alaska Counts Them 1.3 Trainee, Residential Wireman, Lineman, Provisional & Reciprocal Certificates 1.4 The Journeyman Examination: Format, Scheduling, Open-Book Rules & Retakes 1.5 Adopted Codes, Fees, Renewal, Inspection & Enforcement

2 Chapter 2: Using the 2020 NEC

2.1 Article 90: Purpose, Scope, Arrangement & Enforcement 2.2 Navigating the Code Book: Structure, Index & Tabbing Strategy 2.3 Article 100 Definitions You Must Know Cold 2.4 Electrical Theory for the Exam: Ohm's Law, Power & Three-Phase

3 Chapter 3: General Requirements — Article 110

3.1 Approval, Listing, Interrupting Rating & Terminations 3.2 Temperature Limitations of Terminations — 110.14(C) 3.3 Working Space, Access, Egress & Illumination — 110.26(A) through (D) 3.4 Dedicated Equipment Space, Guarding & Over-1000-Volt Installations

4 Chapter 4: Conductors and Ampacity — Article 310

4.1 Conductor Types, Insulation Markings & Table 310.16 4.2 Ambient Temperature Correction and Alaska's Cold 4.3 Adjustment for More Than Three Current-Carrying Conductors 4.4 Putting It Together: Full Conductor-Sizing Problems 4.5 Parallel Conductors, Dwelling Service Sizing & Conditions of Use

5 Chapter 5: Wiring Methods and Materials — NEC Chapter 3

5.1 Article 300 General Requirements and Underground Cover 5.2 Thermal Movement: Expansion Fittings and Table 352.44 5.3 Boxes and Enclosures: Box Fill and Pull Box Sizing 5.4 Cable Assemblies: NM, MC, AC, SE, UF and TC 5.5 Raceways: RMC, IMC, EMT, FMC, LFMC, PVC and ENT 5.6 Conduit Fill: Chapter 9 Tables and Annex C 5.7 Cable Trays, Wireways, Busways, Gutters and Surface Raceways

6 Chapter 6: Branch Circuits and Feeders

6.1 Branch-Circuit Ratings, Conductor Sizing & Multiwire Circuits 6.2 Required Outlets and Receptacle Spacing in Dwellings 6.3 GFCI Protection — Article 210.8 6.4 AFCI Protection and Receptacle Requirements 6.5 Feeders and Outside Branch Circuits — Articles 215 and 225 6.6 Grounded Conductor Identification, Switches & Panelboards

7 Chapter 7: Overcurrent Protection — Articles 240 and 242

7.1 Article 240 Fundamentals: Ratings, Locations & Conductor Protection 7.2 Feeder Tap Rules — 240.21(B) 7.3 Transformer Secondary Conductors — 240.21(C) 7.4 Fuses, Circuit Breakers, Series Ratings & Article 242 Surge Protection

8 Chapter 8: Services and Load Calculations

8.1 Service Conductors, Clearances and Service Equipment 8.2 Service Disconnects, the 2020 Rule Change, SPDs and Service GFPE 8.3 Article 220 Part II: General Lighting, Receptacles and Demand Factors 8.4 The Standard Dwelling Calculation — Article 220 Part III 8.5 Optional Dwelling and Multifamily Calculations 8.6 Commercial and Industrial Load Calculations 8.7 Neutral Load Calculations and Harmonics — 220.61

9 Chapter 9: Grounding and Bonding — Article 250

9.1 System Grounding, 250.24 and the Main Bonding Jumper 9.2 The Grounding Electrode System — 250.50 through 250.53 9.3 Grounding Electrode Conductor Sizing and Installation 9.4 Bonding: Services, Metal Piping, Structural Metal and Other Systems 9.5 Equipment Grounding Conductors: Types, Sizing and Continuity 9.6 Separately Derived Systems and Separate Buildings 9.7 Ground-Fault Protection of Equipment and Grounding of Specific Equipment

10 Chapter 10: Equipment for General Use — NEC Chapter 4

10.1 Flexible Cords, Cables and Fixture Wires 10.2 Switches, Receptacles and Industrial Control Panels 10.3 Luminaires, Lampholders and Recessed Installations 10.4 Appliances and Fixed Electric Space Heating 10.5 Deicing, Snow Melting, Pipeline and Vessel Heating 10.6 Motors Part I: Full-Load Current, Conductors and Overload Protection 10.7 Motors Part II: Short-Circuit Protection, Controllers, Disconnects and HVAC

11 Chapter 11: Transformers, Generators and Special Occupancies

11.1 Transformers — Article 450 11.2 Generators, Storage Batteries and Energy Storage Systems 11.3 Hazardous (Classified) Locations — Articles 500 through 506 11.4 Garages, Hangars, Fuel Dispensing, Bulk Storage and Spray Application 11.5 Health Care Facilities — Article 517 11.6 Agricultural Buildings, Manufactured Homes, RV Parks and Marinas 11.7 Assembly, Theaters, Carnivals, Temporary Installations and Pools

12 Chapter 12: Special Equipment, Special Conditions and Exam Strategy

12.1 Signs, Cranes, Elevators, Electric Vehicle Charging and Welders 12.2 Solar Photovoltaic, Interconnection and Stand-Alone Systems 12.3 Wind Electric Systems and Fire Pumps 12.4 Emergency, Legally Required Standby, Optional Standby and COPS 12.5 Class 1, 2 and 3 Circuits, Fire Alarm, Optical Fiber and Communications 12.6 Cold-Climate Practice in Alaska: Code Basis and Engineering Judgment 12.7 Exam-Day Strategy: Navigation, Calculation Workflow and Time Management

1.1 The Alaska Certificate of Fitness System

Key Takeaways Explain This Topic AI

AS 18.62.010 and AS 18.62.070 require a certificate of fitness for anyone employed to do electrical wiring subject to AS 18.60.580 — Alaska calls the credential a certificate of fitness, not a license.

Certificates of fitness are issued by the Mechanical Inspection Section of the Labor Standards and Safety Division, Alaska Department of Labor and Workforce Development, at 1251 Muldoon Road Suite 113, Anchorage.

8 AAC 90.105 requires the certificate to be in the holder's physical possession while performing trade work; a card left at home is a violation even if the certificate is valid.

8 AAC 90.105(b) and 8 AAC 70.035 exclude true electrical maintenance — like-for-like replacement that needs no alteration and does not change circuit load — from the certificate requirement.

Alaska does not issue a master electrician license; supervisory and permit-signing authority comes from a separate Electrical Administrator license issued by the Department of Commerce under AS 08.40.

Last updated: August 2026

Why This Section Matters

Every other topic in this guide is National Electrical Code content. This first chapter is the layer that surrounds it: who may legally do the work, how the state verifies competence, and how the examination itself is delivered. Candidates routinely arrive at the Anchorage office with the wrong paperwork, the wrong expectation about who administers the test, or hours that Alaska will not count. Getting this layer right is worth more than another hour of conduit-fill drill.

Certificate of Fitness, Not a License

Alaska does not issue an "electrician license" to individuals. It issues a certificate of fitness (COF) . The requirement comes from AS 18.62.010 :

In connection with work performed subject to the standards established in AS 18.60.580 and AS 18.60.705, a person may not be employed without a certificate of fitness to perform the work.

AS 18.62.070 then names the trades: electrical wiring subject to AS 18.60.580, and plumbing subject to the adopted plumbing code. AS 18.60.580 is the statute that lets the department adopt the National Electrical Code by regulation, so "work subject to AS 18.60.580" means, in practice, work covered by the adopted NEC .

The distinction matters on the exam and in the field. A certificate of fitness attaches to a person and proves individual competence. It does not authorize you to contract, bid, or pull permits — those are business credentials issued by a different department.

Who Issues It

Certificates of fitness are administered by the Mechanical Inspection Section of the Labor Standards and Safety Division , within the Alaska Department of Labor and Workforce Development (DOLWD) . The main office is at 1251 Muldoon Road, Suite 113, Anchorage, AK 99504; field inspectors also staff Juneau and Fairbanks offices by appointment. All correspondence runs through mi@alaska.gov .

Mechanical Inspection issues certificates of fitness for:

  • Family Classes issued
  • Electrical Electrician Journeyman, Power Lineman Journeyman, Residential Wireman, Trainee, Provisional
  • Plumbing Plumber Journeyman, Gas (restricted PG), Utility (restricted PU), Trainee, Provisional

Other Asbestos Abatement, Explosive Handler, Hazardous Paint, Boiler Operator (Class 1–4), Inspectors (Amusement, Tramway, Boiler)

Mechanical Inspection explicitly does not issue business licenses, contractor licenses, or administrator licenses. Those come from the Department of Commerce, Community, and Economic Development (DCCED) , Division of Corporations, Business and Professional Licensing.

There Is No Alaska Master Electrician

This is one of the most commonly missed facts about Alaska licensing, and it is stated plainly in the department's own FAQ: Alaska does not issue a master license for the electrical or plumbing trades. The journeyman COF is the top trade credential — it authorizes the holder to perform code work.

Supervision and sign-off authority instead come from an Electrical Administrator license issued by DCCED under AS 08.40 . Two facts follow, and both are exam-worthy:

An Administrator license by itself does not authorize the holder to perform code work.

A person may hold both an Administrator license and a journeyman COF. That combination is what functions like a master electrician in other states.

Holder in Possession — 8 AAC 90.105

8 AAC 90.105(a) requires that an individual performing work subject to AS 18.60.580 hold the appropriate certificate of fitness or a trainee certificate, and that "the certificate must be in the individual's possession when performing work in the trade."

An inspector who finds a qualified journeyman working without the physical card on site can cite the violation even though the certificate itself is current. Treat the card the way you treat a driver's license.

The Maintenance Exclusion — 8 AAC 70.035

Not every task that touches a wire requires a certificate. 8 AAC 90.105(b) states that for purposes of AS 18.62.010, AS 18.62.070(1), and the possession rule, work subject to AS 18.60.580 does not include electrical maintenance within the limitations set out in 8 AAC 70.035 .

8 AAC 70.035 draws the line precisely:

Maintenance (no COF required): replacing or repairing electrical utilization equipment or devices with equipment having the same electrical and mechanical characteristics , provided the replacement (A) needs no alteration or adaptation to be installed, and (B) does not change the electrical load of the affected circuit.

Installation (COF required): replacing conduit, other wiring methods, or conductors — regardless of the length or amount . There is no de minimis allowance for rewiring.

A maintenance technician swapping an identical 1/2 hp exhaust fan motor is doing maintenance. The same technician replacing six feet of damaged MC cable is doing installation work that requires a certificate. Note also that 8 AAC 90.160(f) bars experience as a maintenance electrician from counting toward journeyman hours at all — a rule that has ended more than one Alaska application.

Scope of the Electrician Journeyman Certificate

8 AAC 90.900(10) defines the electrician journeyman trade:

a person who performs work necessary to the installation and construction of electrical work within buildings and within property lines of any given property, beginning at the secondary side of the transformer , subject to the National Electrical Code, but does not include a person performing linework consisting of poles and towers, including wires or cables and other apparatus supported by them.

Two boundaries are built into that definition. The journeyman's territory starts at the secondary side of the transformer and stays inside property lines; primary distribution, poles, towers, and outdoor substations belong to the power lineman journeyman under 8 AAC 90.900(17), whose exam is built on the National Electrical Safety Code rather than the NEC.