Study guide

2.2 Navigating the Code Book: Structure, Index & Tabbing Strategy

Alaska Journeyman Electrician Study Guide Exam

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: Alaska Certificates of Fitness, Law & Exam Logistics

1.1 The Alaska Certificate of Fitness System 1.2 Journeyman Eligibility: 8,000 Hours and How Alaska Counts Them 1.3 Trainee, Residential Wireman, Lineman, Provisional & Reciprocal Certificates 1.4 The Journeyman Examination: Format, Scheduling, Open-Book Rules & Retakes 1.5 Adopted Codes, Fees, Renewal, Inspection & Enforcement

2 Chapter 2: Using the 2020 NEC

2.1 Article 90: Purpose, Scope, Arrangement & Enforcement 2.2 Navigating the Code Book: Structure, Index & Tabbing Strategy 2.3 Article 100 Definitions You Must Know Cold 2.4 Electrical Theory for the Exam: Ohm's Law, Power & Three-Phase

3 Chapter 3: General Requirements — Article 110

3.1 Approval, Listing, Interrupting Rating & Terminations 3.2 Temperature Limitations of Terminations — 110.14(C) 3.3 Working Space, Access, Egress & Illumination — 110.26(A) through (D) 3.4 Dedicated Equipment Space, Guarding & Over-1000-Volt Installations

4 Chapter 4: Conductors and Ampacity — Article 310

4.1 Conductor Types, Insulation Markings & Table 310.16 4.2 Ambient Temperature Correction and Alaska's Cold 4.3 Adjustment for More Than Three Current-Carrying Conductors 4.4 Putting It Together: Full Conductor-Sizing Problems 4.5 Parallel Conductors, Dwelling Service Sizing & Conditions of Use

5 Chapter 5: Wiring Methods and Materials — NEC Chapter 3

5.1 Article 300 General Requirements and Underground Cover 5.2 Thermal Movement: Expansion Fittings and Table 352.44 5.3 Boxes and Enclosures: Box Fill and Pull Box Sizing 5.4 Cable Assemblies: NM, MC, AC, SE, UF and TC 5.5 Raceways: RMC, IMC, EMT, FMC, LFMC, PVC and ENT 5.6 Conduit Fill: Chapter 9 Tables and Annex C 5.7 Cable Trays, Wireways, Busways, Gutters and Surface Raceways

6 Chapter 6: Branch Circuits and Feeders

6.1 Branch-Circuit Ratings, Conductor Sizing & Multiwire Circuits 6.2 Required Outlets and Receptacle Spacing in Dwellings 6.3 GFCI Protection — Article 210.8 6.4 AFCI Protection and Receptacle Requirements 6.5 Feeders and Outside Branch Circuits — Articles 215 and 225 6.6 Grounded Conductor Identification, Switches & Panelboards

7 Chapter 7: Overcurrent Protection — Articles 240 and 242

7.1 Article 240 Fundamentals: Ratings, Locations & Conductor Protection 7.2 Feeder Tap Rules — 240.21(B) 7.3 Transformer Secondary Conductors — 240.21(C) 7.4 Fuses, Circuit Breakers, Series Ratings & Article 242 Surge Protection

8 Chapter 8: Services and Load Calculations

8.1 Service Conductors, Clearances and Service Equipment 8.2 Service Disconnects, the 2020 Rule Change, SPDs and Service GFPE 8.3 Article 220 Part II: General Lighting, Receptacles and Demand Factors 8.4 The Standard Dwelling Calculation — Article 220 Part III 8.5 Optional Dwelling and Multifamily Calculations 8.6 Commercial and Industrial Load Calculations 8.7 Neutral Load Calculations and Harmonics — 220.61

9 Chapter 9: Grounding and Bonding — Article 250

9.1 System Grounding, 250.24 and the Main Bonding Jumper 9.2 The Grounding Electrode System — 250.50 through 250.53 9.3 Grounding Electrode Conductor Sizing and Installation 9.4 Bonding: Services, Metal Piping, Structural Metal and Other Systems 9.5 Equipment Grounding Conductors: Types, Sizing and Continuity 9.6 Separately Derived Systems and Separate Buildings 9.7 Ground-Fault Protection of Equipment and Grounding of Specific Equipment

10 Chapter 10: Equipment for General Use — NEC Chapter 4

10.1 Flexible Cords, Cables and Fixture Wires 10.2 Switches, Receptacles and Industrial Control Panels 10.3 Luminaires, Lampholders and Recessed Installations 10.4 Appliances and Fixed Electric Space Heating 10.5 Deicing, Snow Melting, Pipeline and Vessel Heating 10.6 Motors Part I: Full-Load Current, Conductors and Overload Protection 10.7 Motors Part II: Short-Circuit Protection, Controllers, Disconnects and HVAC

11 Chapter 11: Transformers, Generators and Special Occupancies

11.1 Transformers — Article 450 11.2 Generators, Storage Batteries and Energy Storage Systems 11.3 Hazardous (Classified) Locations — Articles 500 through 506 11.4 Garages, Hangars, Fuel Dispensing, Bulk Storage and Spray Application 11.5 Health Care Facilities — Article 517 11.6 Agricultural Buildings, Manufactured Homes, RV Parks and Marinas 11.7 Assembly, Theaters, Carnivals, Temporary Installations and Pools

12 Chapter 12: Special Equipment, Special Conditions and Exam Strategy

12.1 Signs, Cranes, Elevators, Electric Vehicle Charging and Welders 12.2 Solar Photovoltaic, Interconnection and Stand-Alone Systems 12.3 Wind Electric Systems and Fire Pumps 12.4 Emergency, Legally Required Standby, Optional Standby and COPS 12.5 Class 1, 2 and 3 Circuits, Fire Alarm, Optical Fiber and Communications 12.6 Cold-Climate Practice in Alaska: Code Basis and Engineering Judgment 12.7 Exam-Day Strategy: Navigation, Calculation Workflow and Time Management

2.2 Navigating the Code Book: Structure, Index & Tabbing Strategy

Key Takeaways Explain This Topic AI

The 2020 NEC numbering system is Article.Section(Subsection): 250.122(B) is Article 250, Section 122, Subsection B — chapter numbers are the leading digit of the article number.

Chapter 9 contains the conduit and conductor dimension tables (Tables 1, 4, 5, 5A, 8, 9) and Informative Annex C contains the pre-computed conduit fill tables for conductors that are all the same size.

Informative Annex D contains worked load-calculation examples, and Informative Annex H contains the model administration and enforcement text — neither is enforceable.

The fastest lookup route on an open-book exam is usually the Article table of contents on the article's first page, not the master index at the back.

Before test day, confirm with Mechanical Inspection which tabs, highlighting, and handwritten notes are allowed in your code book, since the exam may be delivered at a division office, a job center, a proctor, or a union hall.

Last updated: August 2026

The Exam Is a Lookup Test

The Alaska journeyman exam is open book with a four-hour ceiling. Nobody passes it by reciting Table 310.16 from memory; people pass it by finding the governing rule in twenty seconds and applying it correctly. Everything in this section is about shortening the distance between a question and the page that answers it.

  • Reading a Code Citation
  • The 2020 NEC uses a consistent decimal system: 250 . 122 (B)
  • | | |
  • | | +-- Subsection B
  • | +------- Section 122 within the article
  • +------------ Article 250 (Grounding and Bonding)

The first digit of the article number is the chapter . Article 250 is in Chapter 2; Article 310 is in Chapter 3; Article 430 is in Chapter 4; Article 517 is in Chapter 5. Once that clicks, you can locate any citation's neighborhood without the index.

Deeper levels stack in a fixed order: section, then letter subsection, then number, then lowercase letter, then Roman numeral — for example 210.8(A)(7) or 110.14(C)(1)(a) . Exceptions are numbered separately ("Exception No. 3") and are part of the enforceable rule.

The Nine Chapters at a Glance

  • Chapter Title What lives there
  • 1 General 90, 100, 110 — definitions, working space, terminations
  • 2 Wiring and Protection 200, 210, 215, 220, 225, 230, 240, 242, 250
  • 3 Wiring Methods and Materials 300, 310, 312, 314, cables 320–340, raceways 342–362, 366–392
  • 4 Equipment for General Use 400, 404, 406, 408, 410, 422–427, 430, 440, 445, 450, 480, 490
  • 5 Special Occupancies 500–517, 518–555, 590
  • 6 Special Equipment 600, 610, 620, 625, 630, 645, 680, 690, 694, 695
  • 7 Special Conditions 700, 701, 702, 705, 706, 708, 710, 712, 725, 760, 770
  • 8 Communications Systems 800, 805, 810, 820, 830, 840
  • 9 Tables Conduit fill, conductor dimensions, conductor properties, AC resistance
  • Where the Numbers You Need Actually Live

A large fraction of calculation questions resolve to one of a handful of tables. Know their homes:

  • You need Go to
  • Allowable ampacity, 0–2000 V, 3 or fewer CCC in raceway/cable/earth Table 310.16
  • Ambient temperature correction factors Table 310.15(B)(1)
  • Adjustment factors for more than 3 current-carrying conductors Table 310.15(C)(1)
  • Standard OCPD ampere ratings 240.6(A)
  • Grounding electrode conductor sizing Table 250.66
  • Equipment grounding conductor sizing Table 250.122
  • Bonding jumper / grounded conductor on supply side Table 250.102(C)(1)
  • Box fill volume per conductor Table 314.16(B)
  • Minimum burial cover Table 300.5
  • Dwelling range demand Table 220.55
  • Motor full-load current Tables 430.247–430.250
  • Motor branch-circuit short-circuit/ground-fault protection Table 430.52
  • Transformer overcurrent protection Table 450.3(B)
  • Raceway percent fill Chapter 9, Table 1
  • Raceway interior area Chapter 9, Table 4
  • Conductor and cable dimensions Chapter 9, Table 5
  • Conductor properties (circular mils, resistance) Chapter 9, Table 8
  • AC resistance and reactance Chapter 9, Table 9
  • Pre-computed fill for same-size conductors Informative Annex C
  • Worked load-calculation examples Informative Annex D

Remember 90.3: Chapter 9 tables apply as referenced , and Annexes C and D are informational . Annex C is enormously useful and universally used, but it is a convenience derived from Chapter 9 — if a question gives you mixed conductor sizes, Annex C does not apply and you must compute from Tables 1, 4, and 5.

Use Article Tables of Contents, Not the Index

Every NEC article opens with its own table of contents listing every section by number and title. That list is nearly always faster than the master index, because you usually know the article from the topic even when you do not know the section.

A practical routine:

Identify the topic domain from the question — grounding, motors, boxes, load calc.

Jump to the article for that domain using your chapter tabs.

Scan the article table of contents for the section title.

Read the section, then check for Exceptions and Informational Notes below it.

The master index at the back is best for odd terms — "pipe organs," "hydromassage," "cellular metal floor raceway" — where you genuinely do not know the article.

A Tabbing System That Works

Overtabbing is the most common self-inflicted wound. A book with 200 tabs is a book you cannot use. Aim for roughly 40 to 60, in three tiers:

Tier 1 — chapter tabs (9). Top edge, largest, colour-coded. These carry most of your navigation.

Tier 2 — high-traffic articles (about 20). Side edge. 100, 110, 210, 220, 225, 230, 240, 250, 300, 310, 314, 320/330/334, 344/348/352/358, 400, 404/406, 408, 410, 430, 440, 450, 500, 517, 680, 700/701/702.

Tier 3 — the tables you will open repeatedly (about 15). Bottom edge, a distinct colour: 220.55, 250.66, 250.102(C)(1), 250.122, 300.5, 310.15(B)(1), 310.15(C)(1), 310.16, 314.16(B), 430.52, 430.248, 430.250, 450.3(B), Chapter 9 Tables 1/4/5, Annex C.

Use one colour per tier so your hand learns which edge to reach for. Write the tab text yourself — a preprinted tab set you did not choose will not match how you think.

Before Test Day

Check the physical rules with Mechanical Inspection in Anchorage. Your exam may be administered at a division office, a Department of Labor job center, an approved proctor, or an Alaska-based union hall, and the person proctoring will inspect your book. Ask specifically about removable tabs , highlighting , handwritten margin notes , and loose inserted sheets . Loose paper is the item most commonly refused. Do not discover the rule at 8:00 a.m. on the first Wednesday of the month.