3.2 Water Piping Materials, Joints, Valves, Supports & Disinfection
Alabama Journeyman Plumber Exam
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: Alabama Law, General Regulations, Trade Math, Tools & Safety
1.1 Alabama Exam Format, Licensing Law & Board Rules 1.2 IPC Chapter 3 General Regulations: Protection, Sleeves, Trenching & Structural Safety 1.3 Trade Math I: Pressure, Head, Fall, Volume & Expansion 1.4 Trade Math II: Fractions, Offsets, Areas & Heat Calculations 1.5 Plumbing Tools: Layout, Cutting, Joining, Threading & Test Equipment 1.6 Jobsite Safety: Trenches, Ladders, Confined Spaces, Hot Work & PPE
2 Chapter 2: Plumbing Fixtures, Fittings & Clearances
2.1 Minimum Plumbing Facilities, Fixture Clearances & Accessibility 2.2 Fixture Materials, Prohibited Fixtures, Overflows, Waste Outlets & Fixture Setting 2.3 Flushing Devices, Water Conservation & Temperature-Limiting Controls
3 Chapter 3: Water Supply, Distribution, Backflow & Water Heaters
3.1 Water Service & Distribution Sizing: WSFU, Demand, Pressure & Friction 3.2 Water Piping Materials, Joints, Valves, Supports & Disinfection 3.3 Cross-Connection Control & Backflow Prevention (IPC 608 & 312.10) 3.4 Water Heaters: Installation, Relief Valves, Pans & Thermal Expansion
4 Chapter 4: Sanitary Drainage Systems & DWV Sizing
4.1 Drainage Fixture Units & Sizing Branches, Stacks and Building Drains 4.2 Drainage Slopes, Building Drain & Sewer Rules, Offsets and Backwater Valves 4.3 DWV Materials, Fittings, Joints, Supports & Underground Installation 4.4 Indirect Waste, Special Waste, Sumps and Sewage Ejectors
5 Chapter 5: Traps, Cleanouts, Interceptors & Separators
5.1 Fixture Traps, Trap Seals, Prohibited Traps & Trap Seal Protection 5.2 Cleanouts: Required Locations, Size, Arrangement, Clearance & Access 5.3 Grease Interceptors, Oil Separators & Other Interceptors (IPC 1003)
6 Chapter 6: Vents and Venting Methods
6.1 Vent Purpose, Vent Stacks, Connections, Terminals & Vent Sizing 6.2 Fixture Vents, Individual Vents, Common Vents & Wet Venting 6.3 Circuit Vents, Combination Waste & Vent, Island, Waste Stack & Single-Stack Venting 6.4 Air Admittance Valves: Standards, Where Permitted, Location & Prohibitions
7 Chapter 7: Plan Reading, Sizing Practice, Testing & Fuel Gas
7.1 Reading Plumbing Drawings, Isometrics, Symbols & Schedules 7.2 Plan-Based Sizing Practice: Branches, Stacks, Building Drain, Vents & Water 7.3 Inspections and Tests: DWV, Water, Sewers, Storm, Shower Pans & Backflow 7.4 Fuel Gas Basics, Combustion Air, Venting & Alabama Gas Fitting Scope
8 Chapter 8: Roof Drain & Storm Drainage Systems
8.1 Roof Drains, Rainfall Rates & Storm Drain Sizing (IPC 1101–1106) 8.2 Secondary (Emergency) Roof Drainage, Scuppers, Controlled Flow, Subsoil Drains & Storm Sumps
3.2 Water Piping Materials, Joints, Valves, Supports & Disinfection
Key Takeaways Explain This Topic AI
IPC Tables 605.3 (water service) and 605.4 (water distribution) list copper tube Types K, WK, L, WL, M and WM, CPVC, PEX, PE-RT, PP, ductile iron, galvanized steel and stainless steel. PVC is listed only for water service.
Water service pipe must be rated at least 160 psi at 73.4°F (IPC 605.3), and hot water distribution pipe at least 100 psi at 180°F (IPC 605.4).
Water supply solder and flux must be lead-free, meaning 0.2% lead or less (IPC 605.13.6), and drinking-water pipe, fittings and faucets must comply with NSF 372 (IPC 605.2.1).
Table 308.5 hanger spacing is 6 feet horizontal for copper tube 1-1/4 inches and smaller, 10 feet for 1-1/2 inches and larger, 32 inches for PEX 1 inch and smaller, and 3 feet for CPVC 1 inch and smaller.
New potable systems are disinfected with at least 50 ppm chlorine held 24 hours, or 200 ppm held 3 hours, then flushed (IPC 610.1).
Last updated: October 2026
Why this section matters
Materials and joints are a large part of General Knowledge and System Installation . In the open-book exam, you must know which table to open and recognize the joining rules that inspectors enforce.
Approved materials (605.3 and 605.4)
Material Water service (Table 605.3) Water distribution (Table 605.4) Notes
Copper tube Types K, WK, L, WL, M, WM (ASTM B88) Yes Yes All three wall types are listed, including Type M. Local practice may prefer K or L underground.
- CPVC (ASTM D2846, F441, F442) Yes Yes Rated 100 psi at 180°F in copper tube sizes
- PEX (ASTM F876) Yes Yes Also PEX-AL-PEX and PEX-AL-HDPE composites
- PE-RT, PP, PE-AL-PE PE-RT, PP and PE-AL-PE in both; plain PE pipe and tubing service only
- Ductile iron (AWWA C151) Yes, cement-mortar lined Yes Usually 3 inches and larger
- Galvanized steel (ASTM A53) Yes Yes Joined by threads; use dielectric fittings to copper
- Stainless steel 304/316 Yes Yes
- PVC (ASTM D1785, D2241) Yes No PVC may not be used for distribution, including hot water
- ABS pressure pipe Yes No
Copper tube is identified by printed color markings: Type K green, Type L blue, Type M red . DWV copper (yellow) is a drainage tube and is not listed in either water table.
Ratings, lead and certification
605.3: Water service pipe installed underground outside the building must be rated at least 160 psi at 73.4°F . Where the available pressure is higher, use a rating at least that high. Service material not certified for distribution must end at or before the full-open valve at the building entrance.
605.4: Hot water distribution pipe must be rated at least 100 psi at 180°F . All water pipe must conform to NSF 61 .
605.2: Water supply pipe and fittings may contain no more than 8% lead . Under 605.2.1 , anything supplying water for drinking or cooking must comply with NSF 372 , the low-lead standard that limits wetted surfaces to a 0.25% weighted-average lead content.
605.13.6: Solder and flux for water supply must be lead-free (0.2% lead or less) and conform to NSF 61.
605.1: Do not install water pipe in soil contaminated with solvents or fuels. If contamination is suspected, a soil and groundwater analysis is required.
Joining methods (605.9–605.24)
Material Joint Key requirements
Copper tube Solder ASTM B828 method; ream to full inside diameter; clean; ASTM B813 flux; ASTM B32 solder (605.13.6)
Copper tube Brazed AWS A5.8 filler; flux where required (605.13.1)
Copper tube Press-connect Fitting per Table 605.5; ream, clean, insert fully; tool certified by the manufacturer (605.13.5)
- Copper tube Push-fit ASSE 1061, installed per the manufacturer (605.13.7)
- Copper tube Flared Made with a flaring tool (605.13.2)
CPVC Solvent cement Follow the pipe maker's instructions. Where primer is required, apply primer and orange ASTM F493 cement. Where allowed, a yellow one-step F493 cement needs no primer (605.14.2)
CPVC Threaded Schedule 80 minimum, with plastic dies; pressure rating reduced 50% (605.14.3)
PEX Mechanical Per the manufacturer, with fittings to the standards marked on the tubing: F1807 or F2159 crimp, F1960 cold expansion, and others (605.16)
- PVC (service) Solvent cement Purple ASTM F656 primer and ASTM D2564 cement (605.21.3)
- Steel Threaded ASME B1.20.1 threads; compound on male threads only (605.17.1)
Prohibited joints (605.9): cement or concrete joints, fittings not approved for the installation, solvent-cement joints between different types of plastic, and saddle-type fittings .
Joints between different materials (605.23):
Copper to galvanized steel requires a copper-alloy fitting, a dielectric fitting or an ASSE 1079 dielectric union (605.23.1).
Plastic to other materials uses approved adapters or transition fittings (605.23.2).
Stainless steel to other materials uses mechanical compression couplings or ASSE 1079 dielectric fittings (605.23.3).
Hangers must not promote galvanic action (308.3).
Valves (606)
Full-open valves (606.1) are required:
- on the water service near the curb;
- at the building entrance;
- for each tenant in multi-tenant buildings;
- on the discharge side of every meter;
at the base of each riser, except in one- and two-family dwellings and multifamily buildings two stories or less;
- at the top of each down-feed pipe, except in one- and two-family dwellings;
- at the entrance to each dwelling unit;
- to each tank;
to every water heater .
Shutoff valves (606.2) are required:
on the supply to each fixture, except bathtubs and showers in one- and two-family dwellings and in hotel sleeping units that have a unit valve;
on the supply to each sillcock ;
on the supply to each appliance.
All valves must be accessible (606.3). Service and hose bibb valves must be identified, as must valves not next to the fixture they serve (606.4).
Valve materials must meet Table 605.7. Full-port ball and gate valves suit isolation. Globe valves throttle and have high pressure loss.
Supports (308)
- Material (Table 308.5) Horizontal Vertical
- Copper tube, 1-1/4 in and smaller 6 ft 10 ft
- Copper tube, 1-1/2 in and larger 10 ft 10 ft
- CPVC, 1 in and smaller 3 ft 10 ft*
- CPVC, 1-1/4 in and larger 4 ft 10 ft*
- PEX, 1 in and smaller 32 in 10 ft*
- PEX, 1-1/4 in and larger 4 ft 10 ft*
- PEX-AL-PEX and PE-AL-PE 32 in 4 ft
- Steel pipe 12 ft 15 ft
* For sizes 2 inches and smaller, add a mid-story guide between vertical supports.
Hangers must carry the pipe and its contents and must be compatible with the pipe material (308.3). Expansion tanks are supported per the manufacturer, not by the piping (308.10). Bundled manifold piping follows Table 308.5, and bundled hot lines must be insulated (308.9).
Water hammer, manifolds and disinfection
604.9: Install ASSE 1010 water-hammer arrestors where quick-closing valves are used, following the manufacturer's sizing and placement. Field-built air chambers lose their air over time.
604.10: Manifolds for parallel (home-run) systems are sized by Table 604.10.1. A 1-inch manifold carries 10 gpm at 4 ft/s or 20 gpm at 8 ft/s. Valves at the manifold must be labeled for the fixture they serve (604.10.2), and the manifold must be accessible. Where the line is 50 feet or less and the meter shows at least 35 psi, each home run may be one size smaller than Table 604.5.
610.1 disinfection:
Flush until clean water appears.
Fill with chlorine solution of at least 50 ppm for 24 hours , or 200 ppm for 3 hours .
Flush until the chlorine is gone.
Repeat if bacteriological tests still show contamination.
A method set by the health authority or water supplier, or AWWA C651/C652, may be used instead.
Exam traps
Type M copper is listed in both Table 605.3 and Table 605.4. The IPC does not ban it underground.
PVC is water service only.
CPVC cement is orange or yellow. Purple primer is the PVC rule.
PEX is supported every 32 inches in sizes up to 1 inch.