Study guide

5.2 Process Control: F/M Ratio, MCRT/SRT & Sludge Settling Characteristics

Alabama Water/Wastewater Operator Certification Study Guide Exam

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: Alabama Regulations, Certification, Exams & Utility Administration

1.1 ADEM Division 335-10-1: Facility Classifications, Grades & Staffing Rules 1.2 Becoming Certified in Alabama: Exam Application, Operator Intern Status, Experience, Renewal & CEHs 1.3 Environmental Compliance, SDWA, Clean Water Act & NPDES Permits 1.4 Alabama's PSI-Delivered WPI Exams: Format, Grade Crosswalk & Need-to-Know Blueprints 1.5 ADEM Drinking-Water Operating Rules (Division 335-7): Control Tests, Residuals, Pressure, Cross-Connections & Records 1.6 Utility Administration: SOPs, Records, Security, Cybersecurity, Emergency Planning & Supervision

2 Chapter 2: Source Water, Wells, Coagulation, Filtration & Membranes

2.1 Source Water Hydrology, Groundwater vs. Surface Water & Protection 2.2 Coagulation Chemistry, Coagulants & Rapid Mixing Mechanics 2.3 Flocculation Basin Design, Clarification & Sedimentation 2.4 Granular Media Filtration, Head Loss & Backwash Protocols 2.5 Membrane Filtration: MF, UF, NF & RO Operation, Integrity Testing and Cleaning 2.6 Wells & Groundwater Systems: Construction, Pumps, Testing and Sanitary Protection (ADEM 335-7-5)

3 Chapter 3: Water Disinfection, Chemical Addition, Stabilization & Residuals

3.1 Chlorination Chemistry, Breakpoint Chlorination & Residuals 3.2 Disinfection Byproducts (DBPs), Stage 1/2 Rules & CT Compliance 3.3 Corrosion Control, Lead and Copper Rule & Fluoridation 3.4 Iron/Manganese Removal, Water Softening & Taste/Odor Control 3.5 Water Treatment Residuals: Sludge, Backwash Recycle & Plant Discharges

4 Chapter 4: Wastewater Preliminary & Primary Treatment

4.1 Wastewater Characteristics, Screening, Shredding & Grit Removal 4.2 Primary Sedimentation Basins, Scum Removal & Clarifier Performance

5 Chapter 5: Secondary Biological Treatment: Activated Sludge

5.1 Activated Sludge Microbiology, Basin Configurations & Aeration Systems 5.2 Process Control: F/M Ratio, MCRT/SRT & Sludge Settling Characteristics 5.3 Operational Troubleshooting (Bulking, Foaming, Pin Floc) & Process Modifications

6 Chapter 6: Fixed-Film Treatment, Lagoons, Nutrient Removal, Tertiary Filtration & Disinfection

6.1 Trickling Filters & Rotating Biological Contactors (RBCs) 6.2 Waste Stabilization Ponds, Aerated Lagoons & Alabama Grade I Lagoon Operations 6.3 Biological Nutrient Removal: Nitrification, Denitrification & Phosphorus Removal 6.4 Tertiary Filtration & Membrane Bioreactors (MBRs) 6.5 Wastewater Disinfection & Dechlorination: Chlorine, UV and Ozone

7 Chapter 7: Sludge Treatment, Biosolids & Odor Control

7.1 Sludge Thickening, Aerobic Digestion & Anaerobic Digestion 7.2 Mechanical Dewatering, Polymer Conditioning & EPA 503 Biosolids Regulations 7.3 Odor Control & Wastewater Chemical Addition

8 Chapter 8: Water Distribution Systems, Installation, Metering & Water Loss

8.1 Distribution Piping Materials, Valves & Finished Water Storage Facilities 8.2 Water Main Flushing, Disinfection Protocols (AWWA C651) & Water Quality Maintenance 8.3 Distribution Hydraulics, Pressure Control & Cross-Connection Prevention 8.4 Main & Service Installation, Tapping, Repair and Utility Locating (Alabama 811) 8.5 Meters, Water Loss Control, Asset Management & Customer Service

9 Chapter 9: Wastewater Collection Systems, Lift Stations & Sewer Maintenance

9.1 Gravity Collection Networks, Manhole Construction & Self-Cleansing Velocity Standards 9.2 Wastewater Lift Stations, Submersible Pumps, Force Mains & Inflow/Infiltration (I&I) 9.3 Sewer Cleaning, CCTV Inspection & SSO Response

10 Chapter 10: Laboratory Procedures, Sampling & Environmental Compliance

10.1 Drinking Water Laboratory Analysis: Turbidity, pH, Alkalinity & Coliform Testing 10.2 Wastewater Laboratory Testing: BOD5, COD, Total Suspended Solids & Settleability 10.3 Representative Sampling Protocols, Preservation, Chain of Custody & QA/QC

11 Chapter 11: Plant Equipment, Pumps, Motors & Instrumentation

11.1 Centrifugal and Positive Displacement Pumps: Operation, Cavitation & Packing/Seals 11.2 Electric Motors, Variable Frequency Drives, Flow Meters & SCADA Systems

12 Chapter 12: Safety: Chemicals, Confined Spaces & Field Hazards

12.1 Chemical Safety: Chlorine Gas Emergency Handling (Kits A & B) & Hydrogen Sulfide (H2S) Hazards 12.2 Permit-Required Confined Space Entry, Lockout/Tagout (LOTO) & Personal Protective Equipment 12.3 Field Safety: Work-Zone Traffic Control, Electrical Hazards, Fall Protection & Hazard Communication

13 Chapter 13: Water & Wastewater Mathematics: Hydraulics, Chemical Feed & Pumping

13.1 Flow Conversions, Geometry, Tank Volume & Detention Time Calculations 13.2 The Pounds Formula, Chemical Feed Rates & Solution Concentration Calculations 13.3 Pumping Math: Total Dynamic Head, Horsepower, Efficiency & Power Cost

14 Chapter 14: Water & Wastewater Mathematics: Treatment Process Calculations

14.1 Clarifier Surface Overflow Rate, Weir Loading & Granular Filter Loading Rates 14.2 Biological Calculations: F/M Ratio, MCRT Solids Balance & Sludge Volume Index (SVI)

5.2 Process Control: F/M Ratio, MCRT/SRT & Sludge Settling Characteristics

Key Takeaways Explain This Topic AI

The Food-to-Microorganism (F/M) ratio quantifies the organic loading applied per unit of biomass; typical conventional activated sludge ranges from 0.2 to 0.5 1/day, while extended aeration targets 0.05 to 0.15 1/day.

Mean Cell Residence Time (MCRT) or Solids Retention Time (SRT) defines the average days biomass remains in the system; conventional plants maintain 5 to 15 days, whereas nitrifying and extended aeration facilities require 15 to 30 days.

Waste Activated Sludge (WAS) is the operator's primary control knob to regulate total biomass inventory, establish target MCRT, and adjust the F/M ratio.

Return Activated Sludge (RAS) recycles active microbial floc from the secondary clarifier to the aeration basin at rates of 25% to 100% of influent flow to prevent clarifier septicity and maintain mixed liquor inventory.

The Sludge Volume Index (SVI) calculates settled sludge volume per gram of MLSS: values of about 80 to 150 mL/g indicate good settling, values below about 80 mL/g suggest old sludge with pin floc, and values above 150 mL/g point to bulking.

Last updated: October 2026

5.2 Process Control: F/M Ratio, MCRT/SRT & Sludge Settling Characteristics

Operational Overview: Biological process control in activated sludge operations requires manipulating physical inputs (sludge wasting, return rates, and aeration) to maintain a healthy, balanced microbial population. The primary tools used by certified operators are the Food-to-Microorganism (F/M) ratio, Mean Cell Residence Time (MCRT), Return Activated Sludge (RAS) blanket management, and Sludge Volume Index (SVI) diagnostics.

Food-to-Microorganism (F/M) Ratio

The Food-to-Microorganism ( F / M F/M F / M ) ratio is a mathematical expression that relates the mass of organic food entering the aeration basin daily to the total mass of living microorganisms available to treat it.

Mathematical Formulation

Food is measured as the daily mass of 5-day Biochemical Oxygen Demand ( BOD 5 \text{BOD}_5 BOD 5 ​ ) or Chemical Oxygen Demand ( COD \text{COD} COD ) applied to the aeration tank. Microorganisms are quantified as the mass of Mixed Liquor Volatile Suspended Solids (MLVSS) held within the aeration basin (volatile solids serve as a surrogate for active living biomass, typically representing 70% to 80% of total MLSS):

F / M = lbs of BOD applied per day lbs of MLVSS in aeration basin F/M = \frac{\text{lbs of BOD applied per day}}{\text{lbs of MLVSS in aeration basin}} F / M = lbs of MLVSS in aeration basin lbs of BOD applied per day ​

Using the fundamental "Pounds Formula" ( lbs = Flow in MGD × Concentration in mg/L × 8.34 lbs/gal \text{lbs} = \text{Flow in MGD} \times \text{Concentration in mg/L} \times 8.34\text{ lbs/gal} lbs = Flow in MGD × Concentration in mg/L × 8.34 lbs/gal ):

F / M = Q inf ( MGD ) × BOD inf ( mg/L ) × 8.34 V aeration ( MG ) × MLVSS ( mg/L ) × 8.34 F/M = \frac{Q_{\text{inf}} (\text{MGD}) \times \text{BOD}_{\text{inf}} (\text{mg/L}) \times 8.34}{V_{\text{aeration}} (\text{MG}) \times \text{MLVSS} (\text{mg/L}) \times 8.34} F / M = V aeration ​ ( MG ) × MLVSS ( mg/L ) × 8.34 Q inf ​ ( MGD ) × BOD inf ​ ( mg/L ) × 8.34 ​

The unit of F / M F/M F / M is pounds of BOD per pound of MLVSS per day, commonly abbreviated as day − 1 \text{day}^{-1} day − 1 or lb BOD / lb MLVSS ⋅ day \text{lb BOD}/\text{lb MLVSS}\cdot\text{day} lb BOD / lb MLVSS ⋅ day .

Biological Growth Kinetics & F/M Relationships

The operating F / M F/M F / M ratio directly dictates the physiological growth phase of the mixed culture:

High F/M Ratio (> 0.5 day − 1 \text{day}^{-1} day − 1 — Log Growth Phase):

Microorganisms enjoy an excess of food relative to population size. Bacteria reproduce at their maximum physiological rate.

Cells produce minimal extracellular polymer; flocs remain dispersed and fragmented.

Result: Incomplete bioflocculation, high effluent turbidity, elevated effluent soluble BOD, and billowing white frothy foam.

Optimum / Conventional F/M Ratio (0.2 to 0.5 day − 1 \text{day}^{-1} day − 1 — Declining Growth Phase):

Food becomes the growth-limiting nutrient. Cell reproduction slows as organisms compete for available substrate.

Bacteria secrete abundant extracellular polymeric substances (EPS), promoting strong bioflocculation.

Result: Dense, golden-brown flocs, rapid settling in secondary clarifiers, and sparkling clear supernatant.

Low F/M Ratio (0.05 to 0.15 day − 1 \text{day}^{-1} day − 1 — Endogenous Respiration Phase):

Microorganisms face severe food starvation. Cellular death exceeds cell division, and living bacteria metabolize their own internal cellular reserves and neighboring dead cell mass.

Sludge volume generation is minimal. Sludge is well-mineralized and stable.

Typical of Extended Aeration and Oxidation Ditch processes. If F/M drops too low (< 0.04), bio-floc disintegrates into tiny pinpoint flocs.

Treatment Process Variation Typical F/M Range ( lb BOD / lb MLVSS ⋅ day \text{lb BOD}/\text{lb MLVSS}\cdot\text{day} lb BOD / lb MLVSS ⋅ day ) Typical Aeration HRT Typical MLSS Concentration (mg/L) Common Operational Characteristics

High-Rate Aeration 0.5 - 1.5 1.5 - 3 hours 1,500 - 3,000 High sludge production; moderate BOD removal; turbid effluent

  • Conventional Plug-Flow 0.2 - 0.5 4 - 8 hours 1,500 - 3,000 Balanced growth; excellent settling; clear effluent
  • Complete-Mix (CMAS) 0.2 - 0.6 3 - 6 hours 2,500 - 4,500 Uniform shock absorption; higher solids density
  • Step-Feed 0.2 - 0.4 3 - 6 hours 2,000 - 5,000 Flexible solids distribution; protects secondary clarifiers

Extended Aeration / Ditch 0.05 - 0.15 18 - 36 hours 3,000 - 6,000 Low sludge yield; complete nitrification; high power demand

Mean Cell Residence Time (MCRT) & Solids Retention Time (SRT)

Mean Cell Residence Time ( MCRT \text{MCRT} MCRT ), also referred to as Solids Retention Time ( SRT \text{SRT} SRT ) or "Sludge Age," represents the average time in days that an individual biological cell remains within the active activated sludge system before being wasted or discharged.

Mass Balance Calculations

MCRT is calculated by dividing the total inventory of solids maintained within the treatment system by the total mass of solids leaving the system per day (via intentional wasting and accidental loss in final effluent).

Complete System MCRT (Aeration Basins + Secondary Clarifiers): MCRT (days) = lbs solids in Aeration Basin + lbs solids in Secondary Clarifiers lbs solids wasted per day (WAS) + lbs solids lost in Effluent per day \text{MCRT (days)} = \frac{\text{lbs solids in Aeration Basin} + \text{lbs solids in Secondary Clarifiers}}{\text{lbs solids wasted per day (WAS)} + \text{lbs solids lost in Effluent per day}} MCRT (days) = lbs solids wasted per day (WAS) + lbs solids lost in Effluent per day lbs solids in Aeration Basin + lbs solids in Secondary Clarifiers ​

MCRT = [ V aer × MLSS × 8.34 ] + [ V clar × Clar SS × 8.34 ] [ Q WAS × WAS SS × 8.34 ] + [ Q eff × Eff TSS × 8.34 ] \text{MCRT} = \frac{[V_{\text{aer}} \times \text{MLSS} \times 8.34] + [V_{\text{clar}} \times \text{Clar}_{\text{SS}} \times 8.34]}{[Q_{\text{WAS}} \times \text{WAS}_{\text{SS}} \times 8.34] + [Q_{\text{eff}} \times \text{Eff}_{\text{TSS}} \times 8.34]} MCRT = [ Q WAS ​ × WAS SS ​ × 8.34 ] + [ Q eff ​ × Eff TSS ​ × 8.34 ] [ V aer ​ × MLSS × 8.34 ] + [ V clar ​ × Clar SS ​ × 8.34 ] ​

Aeration Basin-Only SRT: Many facilities approximate sludge age using the aeration basin inventory alone (assuming clarifier solids represent a constant small fraction): SRT (days) = V aer ( MG ) × MLSS ( mg/L ) × 8.34 [ Q WAS ( MGD ) × WAS SS ( mg/L ) × 8.34 ] + [ Q eff ( MGD ) × Eff TSS ( mg/L ) × 8.34 ] \text{SRT (days)} = \frac{V_{\text{aer}} (\text{MG}) \times \text{MLSS} (\text{mg/L}) \times 8.34}{[Q_{\text{WAS}} (\text{MGD}) \times \text{WAS}_{\text{SS}} (\text{mg/L}) \times 8.34] + [Q_{\text{eff}} (\text{MGD}) \times \text{Eff}_{\text{TSS}} (\text{mg/L}) \times 8.34]} SRT (days) = [ Q WAS ​ ( MGD ) × WAS SS ​ ( mg/L ) × 8.34 ] + [ Q eff ​ ( MGD ) × Eff TSS ​ ( mg/L ) × 8.34 ] V aer ​ ( MG ) × MLSS ( mg/L ) × 8.34 ​

Operational Targets and Temperature Effects

Conventional Activated Sludge: Target MCRT ranges from 5 to 15 days .

Extended Aeration / Oxidation Ditches: Target MCRT ranges from 20 to 30 days .

Nitrification Requirements: Because nitrifying autotrophs ( Nitrosomonas and Nitrobacter ) reproduce far more slowly than heterotrophs, the system MCRT must exceed the minimum "washout" time of the nitrifiers.

At warm summer water temperatures ( 20 ∘ C 20^\circ\text{C} 2 0 ∘ C ), a minimum MCRT of 6 to 8 days is required for complete nitrification.

At cold winter water temperatures ( 10 ∘ C 10^\circ\text{C} 1 0 ∘ C ), nitrifier doubling time slows dramatically, requiring operators to increase target MCRT to 15 to 25+ days by reducing daily wasting. Failure to increase MCRT in winter causes abrupt loss of nitrification and permit violations.

Return Activated Sludge (RAS) Flow Control & Blanket Management

The Return Activated Sludge (RAS) system withdraws settled biological solids from the bottom hoppers of secondary clarifiers and pumps them back to the head of the aeration basin.

Functions of RAS

Maintain Aeration MLSS Inventory: Replenishes active biomass continuously lost from the aeration tank as mixed liquor overflows into the clarifiers.

Prevent Clarifier Septicity: Secondary clarifiers are non-aerated basins. If settled biological sludge remains stagnant on the clarifier floor, the dissolved oxygen in the interstitial water is rapidly consumed. Once conditions turn anoxic or septic, facultative bacteria reduce nitrate to nitrogen gas (causing rising sludge), and anaerobic bacteria produce hydrogen sulfide and organic acids that degrade effluent quality.

RAS Flow Rates and Control Strategies

Typical Operational Range: RAS flow rate ( Q RAS Q_{\text{RAS}} Q RAS ​ ) typically operates between 25% and 100% of forward raw wastewater influent flow ( Q inf Q_{\text{inf}} Q inf ​ ).

Constant Flow Rate vs. Constant Percentage:

Constant Flow Rate: Operator sets a fixed RAS pump flow regardless of diurnal influent swings. During low night flows, RAS percentage is high, pulling the sludge blanket deep; during peak afternoon flows, RAS percentage is low, allowing the blanket to rise temporarily.

Flow-Proportional (Paced) Control: Automated control matches RAS flow as a fixed percentage (e.g., 40%) of influent flow, maintaining a steady hydraulic balance across the clarifiers.

Sludge Blanket Measurement & Management

Operators monitor the depth of the settled sludge layer (sludge blanket) in secondary clarifiers using a clear, graduated acrylic core sampler equipped with a check valve at the bottom—commonly known as a "Sludge Judge."

Target Blanket Depth: In a typical 12- to 15-foot deep clarifier, the blanket depth should be maintained between 1.0 and 3.0 feet above the floor (or less than 25% of total sidewall water depth).

Blanket Rising Diagnostics:

If the blanket is rising while RAS concentration is thick: The RAS pumping rate is too low to keep pace with the mass of solids entering the clarifier; increase RAS pumping rate.

If the blanket is high and RAS concentration is watery/thin: The sludge is bulking (filamentous overgrowth with high SVI) or the clarifier is hydraulically overloaded; increasing RAS will not help and may worsen clarifier scouring.

Dangers of Over-Pumping RAS: Excessive RAS pumping draws down the blanket to zero, creating "rat-holing" or "coning" where clean water is pulled directly into the sludge hopper while settled solids remain behind. High RAS recycle rates also increase the hydraulic overflow velocity in the clarifier, shearing flocs and carrying solids over the effluent weirs.

Waste Activated Sludge (WAS) Control Protocols

Waste Activated Sludge (WAS) represents the excess biomass produced daily from the biological consumption of influent BOD. WAS pumping is the single most critical process control lever available to the plant operator.

Role of WAS: Wasting sets the system solids inventory, which directly determines MCRT and F/M.

Operating Rules:

To increase MCRT (grow an older sludge or initiate nitrification): Decrease the daily WAS pumping rate.

To decrease MCRT (freshen sludge, increase F/M, or combat Nocardia foam / pin floc): Increase the daily WAS pumping rate.

Calculating Daily Required WAS Mass: Target Daily WAS (lbs/day) = Total System Solids Inventory (lbs) Target MCRT (days) − Effluent TSS Loss (lbs/day) \text{Target Daily WAS (lbs/day)} = \frac{\text{Total System Solids Inventory (lbs)}}{\text{Target MCRT (days)}} - \text{Effluent TSS Loss (lbs/day)} Target Daily WAS (lbs/day) = Target MCRT (days) Total System Solids Inventory (lbs) ​ − Effluent TSS Loss (lbs/day) Required WAS Pump Volume (MGD) = Target Daily WAS (lbs/day) WAS Concentration (mg/L) × 8.34 \text{Required WAS Pump Volume (MGD)} = \frac{\text{Target Daily WAS (lbs/day)}}{\text{WAS Concentration (mg/L)} \times 8.34} Required WAS Pump Volume (MGD) = WAS Concentration (mg/L) × 8.34 Target Daily WAS (lbs/day) ​

Sludge Settling Diagnostics & Sludge Volume Index (SVI)

A daily 30-minute settleability test performed in a 1,000 mL cylindrical glass or plastic settleometer provides critical diagnostic data on sludge flocculation and compaction.

The 30-Minute Settleability Test

Collect a fresh, representative sample of mixed liquor from the aeration basin discharge prior to entering the secondary clarifiers.

Pour gently into a 1-liter settleometer, avoiding violent agitation that might shear floc.

Record the settled sludge volume (in mL/L) at 5, 10, 15, 20, and 30 minutes. Observe the settling characteristics:

Initial settling velocity (settling interface should drop rapidly during the first 5-10 minutes).

Supernatant clarity (clear, cloudy, pin floc, straggler floc).

Final compacted sludge volume at 30 minutes ( S S V 30 SSV_{30} SS V 30 ​ ).

Calculating Sludge Volume Index (SVI)

The Sludge Volume Index ( SVI \text{SVI} SVI ) standardizes settleability by normalizing the 30-minute settled volume against the mixed liquor suspended solids concentration:

SVI (mL/g) = Settled Sludge Volume after 30 minutes (mL/L) × 1 , 000 MLSS Concentration (mg/L) \text{SVI (mL/g)} = \frac{\text{Settled Sludge Volume after 30 minutes (mL/L)} \times 1,000}{\text{MLSS Concentration (mg/L)}} SVI (mL/g) = MLSS Concentration (mg/L) Settled Sludge Volume after 30 minutes (mL/L) × 1 , 000 ​

Example Calculation: A mixed liquor sample has an MLSS concentration of 2 , 500 mg/L 2,500\text{ mg/L} 2 , 500 mg/L . In a 1,000 mL settleometer, the sludge settles to 275 mL 275\text{ mL} 275 mL after 30 minutes. SVI = 275 mL/L × 1 , 000 2 , 500 mg/L = 275 , 000 2 , 500 = 110 mL/g \text{SVI} = \frac{275\text{ mL/L} \times 1,000}{2,500\text{ mg/L}} = \frac{275,000}{2,500} = 110\text{ mL/g} SVI = 2 , 500 mg/L 275 mL/L × 1 , 000 ​ = 2 , 500 275 , 000 ​ = 110 mL/g

Comprehensive SVI Diagnostic Matrix

SVI Range (mL/g) Sludge Condition & Characteristics Microscopic / Physical Diagnostics Primary Causes Recommended Operational Response

< 80 Rapid Settling / Old Sludge : dense, compact sludge blanket; settles rapidly leaving fine pin-point floc suspended in supernatant. High MCRT; low F/M; abundance of rotifers and nematodes; over-mineralized, dense floc particles. Under-wasting; excessively old sludge age; over-aeration shearing floc particles. Increase WAS rate to reduce MCRT and lower MLSS inventory; optimize aeration to reduce shear.

80 - 150 Optimum Settling : ideal sludge blanket interface; rapid initial settling; uniform compaction; sparkling clear supernatant. Balanced ecology; predominance of stalked and free-swimming ciliates; robust zoogloeal floc matrix. Well-balanced F/M ratio (0.2-0.5) and target MCRT; optimal DO (1.5-3.0 mg/L). Maintain steady operations ; continue regular routine monitoring of blanket depth and WAS rates.

150 - 250 Slow Settling / Bulking Sludge : fluffy, loose sludge matrix; slow descent; incomplete 30-min compaction; high clarifier blanket. Moderate to heavy filamentous bacteria bridging between floc particles ( Type 1701 , S. natans ). Low dissolved oxygen (< 1.0 mg/L); low F/M; nutrient deficiency ( N N N or P P P ). Identify and correct filament trigger; increase DO; supplement nutrients; check RAS blanket.

> 250 - 400+ Severe Sludge Bulking : volume exceeds 800-900 mL/L at 30 min; zero compaction; massive solids washout over clarifier weirs. Extreme filamentous meshwork or viscous zoogloeal slime holding bound water. Chronic low DO; septic influent with high sulfides ( H 2 S H_2S H 2 ​ S ); severe organic shock. Emergency RAS chlorination (2-5 lbs C l 2 Cl_2 C l 2 ​ /1,000 lbs MLSS); raise DO; neutralize acidic pH.