Study guide

6.4 Tertiary Filtration & Membrane Bioreactors (MBRs)

Alabama Water/Wastewater Operator Certification Study Guide Exam

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: Alabama Regulations, Certification, Exams & Utility Administration

1.1 ADEM Division 335-10-1: Facility Classifications, Grades & Staffing Rules 1.2 Becoming Certified in Alabama: Exam Application, Operator Intern Status, Experience, Renewal & CEHs 1.3 Environmental Compliance, SDWA, Clean Water Act & NPDES Permits 1.4 Alabama's PSI-Delivered WPI Exams: Format, Grade Crosswalk & Need-to-Know Blueprints 1.5 ADEM Drinking-Water Operating Rules (Division 335-7): Control Tests, Residuals, Pressure, Cross-Connections & Records 1.6 Utility Administration: SOPs, Records, Security, Cybersecurity, Emergency Planning & Supervision

2 Chapter 2: Source Water, Wells, Coagulation, Filtration & Membranes

2.1 Source Water Hydrology, Groundwater vs. Surface Water & Protection 2.2 Coagulation Chemistry, Coagulants & Rapid Mixing Mechanics 2.3 Flocculation Basin Design, Clarification & Sedimentation 2.4 Granular Media Filtration, Head Loss & Backwash Protocols 2.5 Membrane Filtration: MF, UF, NF & RO Operation, Integrity Testing and Cleaning 2.6 Wells & Groundwater Systems: Construction, Pumps, Testing and Sanitary Protection (ADEM 335-7-5)

3 Chapter 3: Water Disinfection, Chemical Addition, Stabilization & Residuals

3.1 Chlorination Chemistry, Breakpoint Chlorination & Residuals 3.2 Disinfection Byproducts (DBPs), Stage 1/2 Rules & CT Compliance 3.3 Corrosion Control, Lead and Copper Rule & Fluoridation 3.4 Iron/Manganese Removal, Water Softening & Taste/Odor Control 3.5 Water Treatment Residuals: Sludge, Backwash Recycle & Plant Discharges

4 Chapter 4: Wastewater Preliminary & Primary Treatment

4.1 Wastewater Characteristics, Screening, Shredding & Grit Removal 4.2 Primary Sedimentation Basins, Scum Removal & Clarifier Performance

5 Chapter 5: Secondary Biological Treatment: Activated Sludge

5.1 Activated Sludge Microbiology, Basin Configurations & Aeration Systems 5.2 Process Control: F/M Ratio, MCRT/SRT & Sludge Settling Characteristics 5.3 Operational Troubleshooting (Bulking, Foaming, Pin Floc) & Process Modifications

6 Chapter 6: Fixed-Film Treatment, Lagoons, Nutrient Removal, Tertiary Filtration & Disinfection

6.1 Trickling Filters & Rotating Biological Contactors (RBCs) 6.2 Waste Stabilization Ponds, Aerated Lagoons & Alabama Grade I Lagoon Operations 6.3 Biological Nutrient Removal: Nitrification, Denitrification & Phosphorus Removal 6.4 Tertiary Filtration & Membrane Bioreactors (MBRs) 6.5 Wastewater Disinfection & Dechlorination: Chlorine, UV and Ozone

7 Chapter 7: Sludge Treatment, Biosolids & Odor Control

7.1 Sludge Thickening, Aerobic Digestion & Anaerobic Digestion 7.2 Mechanical Dewatering, Polymer Conditioning & EPA 503 Biosolids Regulations 7.3 Odor Control & Wastewater Chemical Addition

8 Chapter 8: Water Distribution Systems, Installation, Metering & Water Loss

8.1 Distribution Piping Materials, Valves & Finished Water Storage Facilities 8.2 Water Main Flushing, Disinfection Protocols (AWWA C651) & Water Quality Maintenance 8.3 Distribution Hydraulics, Pressure Control & Cross-Connection Prevention 8.4 Main & Service Installation, Tapping, Repair and Utility Locating (Alabama 811) 8.5 Meters, Water Loss Control, Asset Management & Customer Service

9 Chapter 9: Wastewater Collection Systems, Lift Stations & Sewer Maintenance

9.1 Gravity Collection Networks, Manhole Construction & Self-Cleansing Velocity Standards 9.2 Wastewater Lift Stations, Submersible Pumps, Force Mains & Inflow/Infiltration (I&I) 9.3 Sewer Cleaning, CCTV Inspection & SSO Response

10 Chapter 10: Laboratory Procedures, Sampling & Environmental Compliance

10.1 Drinking Water Laboratory Analysis: Turbidity, pH, Alkalinity & Coliform Testing 10.2 Wastewater Laboratory Testing: BOD5, COD, Total Suspended Solids & Settleability 10.3 Representative Sampling Protocols, Preservation, Chain of Custody & QA/QC

11 Chapter 11: Plant Equipment, Pumps, Motors & Instrumentation

11.1 Centrifugal and Positive Displacement Pumps: Operation, Cavitation & Packing/Seals 11.2 Electric Motors, Variable Frequency Drives, Flow Meters & SCADA Systems

12 Chapter 12: Safety: Chemicals, Confined Spaces & Field Hazards

12.1 Chemical Safety: Chlorine Gas Emergency Handling (Kits A & B) & Hydrogen Sulfide (H2S) Hazards 12.2 Permit-Required Confined Space Entry, Lockout/Tagout (LOTO) & Personal Protective Equipment 12.3 Field Safety: Work-Zone Traffic Control, Electrical Hazards, Fall Protection & Hazard Communication

13 Chapter 13: Water & Wastewater Mathematics: Hydraulics, Chemical Feed & Pumping

13.1 Flow Conversions, Geometry, Tank Volume & Detention Time Calculations 13.2 The Pounds Formula, Chemical Feed Rates & Solution Concentration Calculations 13.3 Pumping Math: Total Dynamic Head, Horsepower, Efficiency & Power Cost

14 Chapter 14: Water & Wastewater Mathematics: Treatment Process Calculations

14.1 Clarifier Surface Overflow Rate, Weir Loading & Granular Filter Loading Rates 14.2 Biological Calculations: F/M Ratio, MCRT Solids Balance & Sludge Volume Index (SVI)

6.4 Tertiary Filtration & Membrane Bioreactors (MBRs)

Key Takeaways Explain This Topic AI

Tertiary filters polish secondary effluent to meet low TSS, turbidity or phosphorus limits and to prepare effluent for UV disinfection, but they cannot fix a failing secondary clarifier.

Cloth-media disc filters capture solids on pile fabric and are cleaned by vacuum backwash shoes while the filter stays in service.

Continuous-backwash upflow sand filters move the sand bed downward and wash it in an airlift and washer box, so they need no separate backwash cycle.

Membrane bioreactors replace the secondary clarifier with submerged MF or UF membranes, run at high MLSS (commonly about 8,000 to 12,000 mg/L) and require fine screening to protect the fibers.

MBR membranes are kept clean with air scour, relaxation, maintenance cleans and recovery cleans, using sodium hypochlorite for organics and citric acid for inorganic scale.

Last updated: October 2026

6.4 Tertiary Filtration & Membrane Bioreactors (MBRs)

Many Alabama permits now carry limits that ordinary secondary treatment cannot meet reliably, such as low total phosphorus, low TSS, or effluent quality suited to ultraviolet (UV) disinfection or reuse. The WPI Wastewater Treatment outlines for every class list tertiary treatment equipment and processes: filtration and media filtration (sand, anthracite, disc filters) , and the Class 4 outline (Alabama Grade IV) adds membrane filtration and membrane bioreactors .

Why Tertiary Filtration?

TSS and turbidity polishing. Filters remove the fine biological floc that escapes secondary clarifiers.

Phosphorus removal. Much effluent phosphorus is particulate. Chemical precipitation with alum or ferric salts followed by filtration can reach very low total phosphorus.

Better disinfection. Particles shield bacteria from UV light and chlorine, so lower TSS improves disinfection.

Reuse. Many reuse programs require filtration before disinfection.

A tertiary filter is a polishing step. If a bulking secondary clarifier sends a heavy load of solids forward, filters blind quickly, backwash constantly and still fail. Fix the secondary process first.

Granular Media Filters

Dual-media or deep-bed sand filters work like water plant filters (Section 2.4) but receive more biological solids, so filter runs are shorter and backwash with air scour is important.

Typical loading for wastewater tertiary filters is about 2 to 6 gpm/ft² , with some deep-bed designs higher (Section 14.1).

Continuous-backwash upflow sand filters send feed upward through a sand bed while sand moves slowly downward. An airlift in the center lifts dirty sand to a washer box at the top, where it is scrubbed and returned to the bed and reject water leaves. There is no separate backwash cycle; operators watch sand movement rate, airlift air flow and reject flow .

Traveling-bridge filters wash one shallow cell at a time while the rest of the filter stays online.

Common problems include mudballs from inadequate backwash, biological growth in the media, breakthrough during solids upsets and short runs caused by algae or chemical floc carryover.

Cloth-Media Disc Filters

Disc filters use vertical discs covered with pile cloth media . Water flows from outside to inside the discs, and solids collect on the cloth. As the cloth loads, the water level rises; at a set level, vacuum backwash shoes rotate across the cloth and pull solids off while the filter keeps producing effluent. Heavy solids settle in the tank floor and are removed by a solids-waste pumping cycle. Disc filters have a small footprint and short backwash cycles, but the cloth must be inspected for tears and cleaned periodically if grease, algae or chemical scale builds up.

Chemical Phosphorus Removal Ahead of Filters

When the permit requires low phosphorus:

Feed alum or ferric chloride ahead of a rapid mix and flocculation zone (or into the secondary process).

Allow the metal-phosphate floc to grow, often with polymer.

Capture the floc in the tertiary filter.

Jar tests set the dose. Overdosing wastes chemical, adds sludge and consumes alkalinity; underdosing leaves soluble phosphorus. Metal salts also lower pH, which matters for nitrification (Section 6.3).

Membrane Bioreactors (MBRs)

An MBR combines activated sludge with submerged microfiltration or ultrafiltration membranes that replace the secondary clarifier. Permeate is drawn through the membranes by suction, so effluent quality no longer depends on sludge settling.

  • Feature Typical MBR practice
  • Mixed liquor suspended solids Commonly about 8,000 to 12,000 mg/L, much higher than conventional plants
  • Pretreatment Fine screens (about 1 to 2 mm) to remove hair, fibers and rags that wrap fibers
  • Effluent quality TSS typically below a few mg/L and very low turbidity
  • Footprint Small, because no secondary clarifiers are needed
  • Energy Higher, mainly for membrane air scour

Operating an MBR:

Air scour bubbles continuously or cyclically up through the membrane modules to shear solids off the surface.

Relaxation (pausing permeate flow for a short period) or short backpulses let the cake layer loosen.

Maintenance cleans with a mild chlorine or acid solution are done on a routine schedule, often weekly.

Recovery cleans soak the membranes in stronger sodium hypochlorite (for organic and biological fouling) and citric acid (for inorganic scale and metals) when permeability drops.

Operators track transmembrane pressure (TMP) and permeability (flux divided by TMP, temperature-corrected). A steady rise in TMP at constant flux means fouling.

Because there is no clarifier, the sludge age (SRT) is controlled only by wasting , and solids inventory is high. Foaming, high mixed-liquor viscosity and fats, oils and grease all make membrane fouling worse.

Worked Example: Disc Filter Loading

A disc filter with 600 ft² of submerged cloth area treats 3.0 MGD. Flow = 3,000,000 gal/day 1,440 min/day = 2,083 gpm \text{Flow} = \frac{3{,}000{,}000\text{ gal/day}}{1{,}440\text{ min/day}} = 2{,}083\text{ gpm} Flow = 1 , 440 min/day 3 , 000 , 000 gal/day ​ = 2 , 083 gpm Hydraulic loading = 2,083 gpm 600 ft 2 = 3.5 gpm/ft 2 \text{Hydraulic loading} = \frac{2{,}083\text{ gpm}}{600\text{ ft}^2} = 3.5\text{ gpm/ft}^2 Hydraulic loading = 600 ft 2 2 , 083 gpm ​ = 3.5 gpm/ft 2

Compare the result with the manufacturer's rated loading, and remember that peak wet-weather flows can be several times the average.