Study guide

6.5 Wastewater Disinfection & Dechlorination: Chlorine, UV and Ozone

Alabama Water/Wastewater Operator Certification Study Guide Exam

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: Alabama Regulations, Certification, Exams & Utility Administration

1.1 ADEM Division 335-10-1: Facility Classifications, Grades & Staffing Rules 1.2 Becoming Certified in Alabama: Exam Application, Operator Intern Status, Experience, Renewal & CEHs 1.3 Environmental Compliance, SDWA, Clean Water Act & NPDES Permits 1.4 Alabama's PSI-Delivered WPI Exams: Format, Grade Crosswalk & Need-to-Know Blueprints 1.5 ADEM Drinking-Water Operating Rules (Division 335-7): Control Tests, Residuals, Pressure, Cross-Connections & Records 1.6 Utility Administration: SOPs, Records, Security, Cybersecurity, Emergency Planning & Supervision

2 Chapter 2: Source Water, Wells, Coagulation, Filtration & Membranes

2.1 Source Water Hydrology, Groundwater vs. Surface Water & Protection 2.2 Coagulation Chemistry, Coagulants & Rapid Mixing Mechanics 2.3 Flocculation Basin Design, Clarification & Sedimentation 2.4 Granular Media Filtration, Head Loss & Backwash Protocols 2.5 Membrane Filtration: MF, UF, NF & RO Operation, Integrity Testing and Cleaning 2.6 Wells & Groundwater Systems: Construction, Pumps, Testing and Sanitary Protection (ADEM 335-7-5)

3 Chapter 3: Water Disinfection, Chemical Addition, Stabilization & Residuals

3.1 Chlorination Chemistry, Breakpoint Chlorination & Residuals 3.2 Disinfection Byproducts (DBPs), Stage 1/2 Rules & CT Compliance 3.3 Corrosion Control, Lead and Copper Rule & Fluoridation 3.4 Iron/Manganese Removal, Water Softening & Taste/Odor Control 3.5 Water Treatment Residuals: Sludge, Backwash Recycle & Plant Discharges

4 Chapter 4: Wastewater Preliminary & Primary Treatment

4.1 Wastewater Characteristics, Screening, Shredding & Grit Removal 4.2 Primary Sedimentation Basins, Scum Removal & Clarifier Performance

5 Chapter 5: Secondary Biological Treatment: Activated Sludge

5.1 Activated Sludge Microbiology, Basin Configurations & Aeration Systems 5.2 Process Control: F/M Ratio, MCRT/SRT & Sludge Settling Characteristics 5.3 Operational Troubleshooting (Bulking, Foaming, Pin Floc) & Process Modifications

6 Chapter 6: Fixed-Film Treatment, Lagoons, Nutrient Removal, Tertiary Filtration & Disinfection

6.1 Trickling Filters & Rotating Biological Contactors (RBCs) 6.2 Waste Stabilization Ponds, Aerated Lagoons & Alabama Grade I Lagoon Operations 6.3 Biological Nutrient Removal: Nitrification, Denitrification & Phosphorus Removal 6.4 Tertiary Filtration & Membrane Bioreactors (MBRs) 6.5 Wastewater Disinfection & Dechlorination: Chlorine, UV and Ozone

7 Chapter 7: Sludge Treatment, Biosolids & Odor Control

7.1 Sludge Thickening, Aerobic Digestion & Anaerobic Digestion 7.2 Mechanical Dewatering, Polymer Conditioning & EPA 503 Biosolids Regulations 7.3 Odor Control & Wastewater Chemical Addition

8 Chapter 8: Water Distribution Systems, Installation, Metering & Water Loss

8.1 Distribution Piping Materials, Valves & Finished Water Storage Facilities 8.2 Water Main Flushing, Disinfection Protocols (AWWA C651) & Water Quality Maintenance 8.3 Distribution Hydraulics, Pressure Control & Cross-Connection Prevention 8.4 Main & Service Installation, Tapping, Repair and Utility Locating (Alabama 811) 8.5 Meters, Water Loss Control, Asset Management & Customer Service

9 Chapter 9: Wastewater Collection Systems, Lift Stations & Sewer Maintenance

9.1 Gravity Collection Networks, Manhole Construction & Self-Cleansing Velocity Standards 9.2 Wastewater Lift Stations, Submersible Pumps, Force Mains & Inflow/Infiltration (I&I) 9.3 Sewer Cleaning, CCTV Inspection & SSO Response

10 Chapter 10: Laboratory Procedures, Sampling & Environmental Compliance

10.1 Drinking Water Laboratory Analysis: Turbidity, pH, Alkalinity & Coliform Testing 10.2 Wastewater Laboratory Testing: BOD5, COD, Total Suspended Solids & Settleability 10.3 Representative Sampling Protocols, Preservation, Chain of Custody & QA/QC

11 Chapter 11: Plant Equipment, Pumps, Motors & Instrumentation

11.1 Centrifugal and Positive Displacement Pumps: Operation, Cavitation & Packing/Seals 11.2 Electric Motors, Variable Frequency Drives, Flow Meters & SCADA Systems

12 Chapter 12: Safety: Chemicals, Confined Spaces & Field Hazards

12.1 Chemical Safety: Chlorine Gas Emergency Handling (Kits A & B) & Hydrogen Sulfide (H2S) Hazards 12.2 Permit-Required Confined Space Entry, Lockout/Tagout (LOTO) & Personal Protective Equipment 12.3 Field Safety: Work-Zone Traffic Control, Electrical Hazards, Fall Protection & Hazard Communication

13 Chapter 13: Water & Wastewater Mathematics: Hydraulics, Chemical Feed & Pumping

13.1 Flow Conversions, Geometry, Tank Volume & Detention Time Calculations 13.2 The Pounds Formula, Chemical Feed Rates & Solution Concentration Calculations 13.3 Pumping Math: Total Dynamic Head, Horsepower, Efficiency & Power Cost

14 Chapter 14: Water & Wastewater Mathematics: Treatment Process Calculations

14.1 Clarifier Surface Overflow Rate, Weir Loading & Granular Filter Loading Rates 14.2 Biological Calculations: F/M Ratio, MCRT Solids Balance & Sludge Volume Index (SVI)

6.5 Wastewater Disinfection & Dechlorination: Chlorine, UV and Ozone

Key Takeaways Explain This Topic AI

Ten States Standards call for a chlorine contact time of at least 15 minutes at design peak hourly flow in a baffled contact tank.

Nitrite exerts a chlorine demand of about 5 mg/L of chlorine per mg/L of nitrite-nitrogen, so partial nitrification can cause sudden disinfection failure.

Theoretical dechlorination ratios are about 0.9 mg sulfur dioxide, 1.46 mg sodium bisulfite, 1.34 mg sodium metabisulfite and 1.78 mg sodium sulfite per mg of chlorine.

UV dose equals intensity times exposure time (mW/cm² times seconds equals mJ/cm²) and falls when UV transmittance drops, TSS rises, lamps age or quartz sleeves foul.

Ozone must be generated on site, leaves no lasting residual and requires off-gas destruction because OSHA's ozone PEL is 0.1 ppm.

Last updated: October 2026

6.5 Wastewater Disinfection & Dechlorination: Chlorine, UV and Ozone

Secondary treatment removes most organic matter but leaves large numbers of bacteria and viruses. Disinfection reduces pathogens before discharge so that the receiving stream can be used for swimming, fishing or water supply. Every WPI Wastewater Treatment outline lists chlorination (chlorine, hypochlorite, chloramine), dechlorination (sodium bisulfite, sodium thiosulfate, sulfur dioxide) and ultraviolet (UV) equipment and processes; the Class 4 outline adds ozonation .

Permit Targets

ADEM NPDES permits set bacterial limits, commonly E. coli in fresh waters (enterococci are used for coastal waters), as monthly geometric means and single-sample maximums based on the stream's use classification. Permits for chlorinating plants also set total residual chlorine (TRC) limits, often very low because chlorine is toxic to aquatic life; EPA's aquatic-life criteria for TRC are 0.011 mg/L (chronic) and 0.019 mg/L (acute). That is why most chlorinating plants also dechlorinate .

Chlorination of Wastewater

Feed and mixing. Chlorine gas or sodium hypochlorite is added at a point of rapid mixing, then the water flows through a baffled, plug-flow contact tank . Ten States Standards call for at least 15 minutes of contact at design peak hourly flow .

Residual chemistry is different from drinking water. Wastewater usually contains ammonia, so chlorine forms combined chlorine (chloramines) rather than free chlorine. Wastewater plants therefore control on total chlorine residual measured by DPD or amperometric titration. In a fully nitrified effluent with little ammonia, free chlorine can form, which disinfects faster but also reacts more with organics.

Nitrite demand. Partial nitrification, common during start-up or cold weather, leaves nitrite , which consumes chlorine rapidly: NO 2 − + HOCl → NO 3 − + HCl \text{NO}_2^- + \text{HOCl} \rightarrow \text{NO}_3^- + \text{HCl} NO 2 − ​ + HOCl → NO 3 − ​ + HCl

Each mg/L of nitrite-nitrogen consumes about 5 mg/L of chlorine ( 70.9 ÷ 14.0 ≈ 5.1 70.9 \div 14.0 \approx 5.1 70.9 ÷ 14.0 ≈ 5.1 ). A sudden jump in chlorine demand with an unchanged flow often points to nitrite.

Control. Most plants pace chlorine feed to flow and trim it with a residual analyzer (compound-loop control). Operators verify analyzers against manual tests and check contact tanks for short-circuiting, solids accumulation and algae.

Contact time check. A 50,000-gallon contact tank at a peak hourly flow of 3.0 MGD has a theoretical detention time of: 50,000 gal 3,000,000 gal/day ÷ 1,440 min/day = 50,000 2,083 = 24 minutes \frac{50{,}000\text{ gal}}{3{,}000{,}000\text{ gal/day} \div 1{,}440\text{ min/day}} = \frac{50{,}000}{2{,}083} = 24\text{ minutes} 3 , 000 , 000 gal/day ÷ 1 , 440 min/day 50 , 000 gal ​ = 2 , 083 50 , 000 ​ = 24 minutes

That exceeds the 15-minute guideline, although baffling and short-circuiting reduce the effective time.

Dechlorination

Dechlorination chemicals react almost instantly with chlorine residual. The theoretical amounts needed per mg/L of chlorine are:

  • Chemical Formula mg per mg of chlorine (theoretical) Notes
  • Sulfur dioxide SO 2 \text{SO}_2 SO 2 ​ about 0.9 Gas fed like chlorine; corrosive and toxic
  • Sodium bisulfite NaHSO 3 \text{NaHSO}_3 NaHSO 3 ​ about 1.46 Common liquid choice

Sodium metabisulfite Na 2 S 2 O 5 \text{Na}_2\text{S}_2\text{O}_5 Na 2 ​ S 2 ​ O 5 ​ about 1.34 Dry or solution

Sodium sulfite Na 2 SO 3 \text{Na}_2\text{SO}_3 Na 2 ​ SO 3 ​ about 1.78 Tablets or solution

Sodium thiosulfate Na 2 S 2 O 3 \text{Na}_2\text{S}_2\text{O}_3 Na 2 ​ S 2 ​ O 3 ​ varies with pH Slower reacting; also used in sample bottles

Field doses are usually a little above theoretical. Overdosing wastes chemical, depresses dissolved oxygen and can lower pH, so feed is paced to the chlorine residual with a small excess.

Example. A 2.0 MGD effluent carries 1.2 mg/L total chlorine. Sodium bisulfite needed is 1.2 × 1.46 = 1.75 1.2 \times 1.46 = 1.75 1.2 × 1.46 = 1.75 mg/L, or 2.0 × 1.75 × 8.34 = 29.2 2.0 \times 1.75 \times 8.34 = 29.2 2.0 × 1.75 × 8.34 = 29.2 lb/day of 100 percent sodium bisulfite. For a 38 percent solution with a specific gravity of 1.36, the solution holds 1.36 × 8.34 × 0.38 = 4.31 1.36 \times 8.34 \times 0.38 = 4.31 1.36 × 8.34 × 0.38 = 4.31 lb per gallon, so the feed is about 29.2 ÷ 4.31 = 6.8 29.2 \div 4.31 = 6.8 29.2 ÷ 4.31 = 6.8 gallons per day.

Ultraviolet Disinfection

UV light at about 254 nm damages microbial DNA so organisms cannot reproduce. UV adds no chemical, forms no regulated byproducts and needs no dechlorination, but it leaves no residual .

Dose: Dose (mJ/cm 2 ) = Intensity (mW/cm 2 ) × Exposure time (s) \text{Dose (mJ/cm}^2) = \text{Intensity (mW/cm}^2) \times \text{Exposure time (s)} Dose (mJ/cm 2 ) = Intensity (mW/cm 2 ) × Exposure time (s) .

UV transmittance (UVT) is the percent of UV light that passes through 1 cm of water. Secondary effluent commonly ranges from about 55 to 75 percent; lower UVT means less dose.

TSS and particle size matter because bacteria inside particles are shielded.

Lamp types: low-pressure, low-pressure high-output (amalgam) and medium-pressure lamps. Output declines with age, so lamps are replaced on the manufacturer's schedule.

Sleeve fouling by iron, calcium, grease and biofilm lowers intensity. Automatic wipers and periodic chemical cleaning keep quartz sleeves clear.

Keep the water level over the lamps constant and avoid exposing lamps to air. Monitor intensity sensors, UVT, flow pacing and lamp-failure alarms.

Never look at an operating lamp; UV burns eyes and skin.

Ozone

Ozone is generated on site from air or oxygen by corona discharge and dissolved through diffusers or injectors. It is a powerful disinfectant and oxidant, decays quickly and leaves no lasting residual , and is toxic. Contactor off-gas passes through an ozone destruct unit , and ambient monitors protect staff; OSHA's permissible exposure limit for ozone is 0.1 ppm as an 8-hour average.