Study guide

10.2 Wastewater Laboratory Testing: BOD5, COD, Total Suspended Solids & Settleability

Alabama Water/Wastewater Operator Certification Study Guide Exam

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: Alabama Regulations, Certification, Exams & Utility Administration

1.1 ADEM Division 335-10-1: Facility Classifications, Grades & Staffing Rules 1.2 Becoming Certified in Alabama: Exam Application, Operator Intern Status, Experience, Renewal & CEHs 1.3 Environmental Compliance, SDWA, Clean Water Act & NPDES Permits 1.4 Alabama's PSI-Delivered WPI Exams: Format, Grade Crosswalk & Need-to-Know Blueprints 1.5 ADEM Drinking-Water Operating Rules (Division 335-7): Control Tests, Residuals, Pressure, Cross-Connections & Records 1.6 Utility Administration: SOPs, Records, Security, Cybersecurity, Emergency Planning & Supervision

2 Chapter 2: Source Water, Wells, Coagulation, Filtration & Membranes

2.1 Source Water Hydrology, Groundwater vs. Surface Water & Protection 2.2 Coagulation Chemistry, Coagulants & Rapid Mixing Mechanics 2.3 Flocculation Basin Design, Clarification & Sedimentation 2.4 Granular Media Filtration, Head Loss & Backwash Protocols 2.5 Membrane Filtration: MF, UF, NF & RO Operation, Integrity Testing and Cleaning 2.6 Wells & Groundwater Systems: Construction, Pumps, Testing and Sanitary Protection (ADEM 335-7-5)

3 Chapter 3: Water Disinfection, Chemical Addition, Stabilization & Residuals

3.1 Chlorination Chemistry, Breakpoint Chlorination & Residuals 3.2 Disinfection Byproducts (DBPs), Stage 1/2 Rules & CT Compliance 3.3 Corrosion Control, Lead and Copper Rule & Fluoridation 3.4 Iron/Manganese Removal, Water Softening & Taste/Odor Control 3.5 Water Treatment Residuals: Sludge, Backwash Recycle & Plant Discharges

4 Chapter 4: Wastewater Preliminary & Primary Treatment

4.1 Wastewater Characteristics, Screening, Shredding & Grit Removal 4.2 Primary Sedimentation Basins, Scum Removal & Clarifier Performance

5 Chapter 5: Secondary Biological Treatment: Activated Sludge

5.1 Activated Sludge Microbiology, Basin Configurations & Aeration Systems 5.2 Process Control: F/M Ratio, MCRT/SRT & Sludge Settling Characteristics 5.3 Operational Troubleshooting (Bulking, Foaming, Pin Floc) & Process Modifications

6 Chapter 6: Fixed-Film Treatment, Lagoons, Nutrient Removal, Tertiary Filtration & Disinfection

6.1 Trickling Filters & Rotating Biological Contactors (RBCs) 6.2 Waste Stabilization Ponds, Aerated Lagoons & Alabama Grade I Lagoon Operations 6.3 Biological Nutrient Removal: Nitrification, Denitrification & Phosphorus Removal 6.4 Tertiary Filtration & Membrane Bioreactors (MBRs) 6.5 Wastewater Disinfection & Dechlorination: Chlorine, UV and Ozone

7 Chapter 7: Sludge Treatment, Biosolids & Odor Control

7.1 Sludge Thickening, Aerobic Digestion & Anaerobic Digestion 7.2 Mechanical Dewatering, Polymer Conditioning & EPA 503 Biosolids Regulations 7.3 Odor Control & Wastewater Chemical Addition

8 Chapter 8: Water Distribution Systems, Installation, Metering & Water Loss

8.1 Distribution Piping Materials, Valves & Finished Water Storage Facilities 8.2 Water Main Flushing, Disinfection Protocols (AWWA C651) & Water Quality Maintenance 8.3 Distribution Hydraulics, Pressure Control & Cross-Connection Prevention 8.4 Main & Service Installation, Tapping, Repair and Utility Locating (Alabama 811) 8.5 Meters, Water Loss Control, Asset Management & Customer Service

9 Chapter 9: Wastewater Collection Systems, Lift Stations & Sewer Maintenance

9.1 Gravity Collection Networks, Manhole Construction & Self-Cleansing Velocity Standards 9.2 Wastewater Lift Stations, Submersible Pumps, Force Mains & Inflow/Infiltration (I&I) 9.3 Sewer Cleaning, CCTV Inspection & SSO Response

10 Chapter 10: Laboratory Procedures, Sampling & Environmental Compliance

10.1 Drinking Water Laboratory Analysis: Turbidity, pH, Alkalinity & Coliform Testing 10.2 Wastewater Laboratory Testing: BOD5, COD, Total Suspended Solids & Settleability 10.3 Representative Sampling Protocols, Preservation, Chain of Custody & QA/QC

11 Chapter 11: Plant Equipment, Pumps, Motors & Instrumentation

11.1 Centrifugal and Positive Displacement Pumps: Operation, Cavitation & Packing/Seals 11.2 Electric Motors, Variable Frequency Drives, Flow Meters & SCADA Systems

12 Chapter 12: Safety: Chemicals, Confined Spaces & Field Hazards

12.1 Chemical Safety: Chlorine Gas Emergency Handling (Kits A & B) & Hydrogen Sulfide (H2S) Hazards 12.2 Permit-Required Confined Space Entry, Lockout/Tagout (LOTO) & Personal Protective Equipment 12.3 Field Safety: Work-Zone Traffic Control, Electrical Hazards, Fall Protection & Hazard Communication

13 Chapter 13: Water & Wastewater Mathematics: Hydraulics, Chemical Feed & Pumping

13.1 Flow Conversions, Geometry, Tank Volume & Detention Time Calculations 13.2 The Pounds Formula, Chemical Feed Rates & Solution Concentration Calculations 13.3 Pumping Math: Total Dynamic Head, Horsepower, Efficiency & Power Cost

14 Chapter 14: Water & Wastewater Mathematics: Treatment Process Calculations

14.1 Clarifier Surface Overflow Rate, Weir Loading & Granular Filter Loading Rates 14.2 Biological Calculations: F/M Ratio, MCRT Solids Balance & Sludge Volume Index (SVI)

10.2 Wastewater Laboratory Testing: BOD5, COD, Total Suspended Solids & Settleability

Key Takeaways Explain This Topic AI

Standard 5-day BOD testing at 20°C in the dark requires aerated nutrient dilution water, seed correction when applicable, and strict validity criteria: minimum DO depletion of 2.0 mg/L and residual DO of at least 1.0 mg/L.

Adding the nitrification inhibitor TCMP converts total BOD to Carbonaceous BOD (CBOD5) by preventing autotrophic nitrifiers from oxidizing ammonia and organic nitrogen.

Chemical Oxygen Demand (COD) utilizes potassium dichromate digestion in strong sulfuric acid at 150°C for 2 hours with silver sulfate catalyst and mercuric sulfate chloride-masking, yielding a rapid 2-hour measure that correlates at a 1.5:1 to 2.5:1 ratio with municipal BOD.

Total Suspended Solids (TSS) gravimetric analysis dries filtered residue on Whatman 934-AH glass fiber filters at 103–105°C, while Volatile Suspended Solids (VSS) burns off organics in a muffle furnace at 550°C to quantify biological biomass.

Settleable solids testing in a 1-liter Imhoff cone requires a 45-minute settle, gentle wall stir, and 15-minute final settle to verify primary clarifier efficiency in mL/L.

Last updated: October 2026

Wastewater Laboratory Testing: BOD5, COD, Total Suspended Solids & Settleability

Core Principle: Wastewater treatment facilities operate biological and physical separation barriers to remove oxygen-depleting organics, nutrients, and suspended solids. Rigorous laboratory testing provides plant operators with real-time operational feedback to adjust aeration, sludge wasting, and chemical feeds, while producing legally defensible compliance data for National Pollutant Discharge Elimination System (NPDES) permits administered by ADEM.

1. Biochemical Oxygen Demand (BOD5) & Carbonaceous BOD (CBOD5)

Biochemical Oxygen Demand ( BOD \text{BOD} BOD ) measures the mass of dissolved oxygen consumed by aerobic microorganisms as they decompose biodegradable organic matter in water over a standardized incubation period. When organic-rich wastewater is discharged into receiving streams, bacterial decomposition consumes dissolved oxygen, suffocating fish and degrading aquatic ecosystems. The standard laboratory test quantifies oxygen consumption over 5 days at 20.0 ± 1.0 ∘ C 20.0 \pm 1.0^\circ\text{C} 20.0 ± 1. 0 ∘ C in the dark ( BOD 5 \text{BOD}_5 BOD 5 ​ ) .

The Nitrification Problem & CBOD5

In standard aerobic biological oxidation, two distinct oxygen demands occur:

Carbonaceous Oxygen Demand (CBOD): Heterotrophic bacteria oxidize organic carbon compounds to carbon dioxide and water: Organic Carbon ( C a H b O c ) + O 2 → Heterotrophs C O 2 + H 2 O + New Cells \text{Organic Carbon } (C_a H_b O_c) + O_2 \xrightarrow{\text{Heterotrophs}} CO_2 + H_2O + \text{New Cells} Organic Carbon ( C a ​ H b ​ O c ​ ) + O 2 ​ Heterotrophs ​ C O 2 ​ + H 2 ​ O + New Cells

Nitrogenous Oxygen Demand (NBOD): Autotrophic nitrifying bacteria ( Nitrosomonas and Nitrobacter ) oxidize reduced nitrogen compounds (ammonia and organic nitrogen) to nitrite and nitrate: N H 4 + + 1.5 O 2 → Nitrosomonas N O 2 − + H 2 O + 2 H + NH_4^+ + 1.5 O_2 \xrightarrow{\text{Nitrosomonas}} NO_2^- + H_2O + 2H^+ N H 4 + ​ + 1.5 O 2 ​ Nitrosomonas ​ N O 2 − ​ + H 2 ​ O + 2 H + N O 2 − + 0.5 O 2 → Nitrobacter N O 3 − NO_2^- + 0.5 O_2 \xrightarrow{\text{Nitrobacter}} NO_3^- N O 2 − ​ + 0.5 O 2 ​ Nitrobacter ​ N O 3 − ​

In raw municipal wastewater, nitrifiers are present in low concentrations, and NBOD typically does not exert significant oxygen demand until day 6 to 10 of incubation. However, in modern secondary effluents, especially facilities practicing biological nitrification or extended aeration, large, acclimated populations of nitrifying bacteria are discharged into the sample bottle. These nitrifiers immediately consume large amounts of oxygen ( 4.57 mg O 2 4.57\text{ mg } O_2 4.57 mg O 2 ​ per 1.0 mg N H 3 -N 1.0\text{ mg } NH_3\text{-N} 1.0 mg N H 3 ​ -N oxidized), creating a falsely elevated apparent organic load.

To isolate organic carbon removal performance, standard methods add a nitrification inhibitor— 2-chloro-6-(trichloromethyl) pyridine (TCMP) —to the sample bottle prior to incubation. TCMP selectively suppresses nitrifier metabolism without inhibiting heterotrophic carbon oxidizers. The result is reported as Carbonaceous Biochemical Oxygen Demand (CBOD5) , which many NPDES permits, including many ADEM municipal permits, use as the oxygen-demand limit.

Dilution Water Preparation (Standard Methods 5210B)

Because raw wastewater ( 100 − 300 mg/L BOD 100-300\text{ mg/L BOD} 100 − 300 mg/L BOD ) and even secondary effluent ( 10 − 30 mg/L BOD 10-30\text{ mg/L BOD} 10 − 30 mg/L BOD ) exceed the maximum dissolved oxygen solubility in water ( ∼ 9.0 mg/L \sim 9.0\text{ mg/L} ∼ 9.0 mg/L at 20°C), samples must be diluted with nutrient-fortified, oxygen-saturated water.

Water Source: High-purity deionized or distilled water free of toxic heavy metals, chlorine, and organic compounds. The water must be aerated with clean, oil-free compressed air until dissolved oxygen reaches near-saturation ( 8.0 − 9.0 mg/L 8.0-9.0\text{ mg/L} 8.0 − 9.0 mg/L ).

Nutrient Buffers: Add 1.0 mL 1.0\text{ mL} 1.0 mL per liter of each of four essential stock solutions:

Phosphate Buffer Solution: ( K H 2 P O 4 KH_2PO_4 K H 2 ​ P O 4 ​ , K 2 H P O 4 K_2HPO_4 K 2 ​ H P O 4 ​ , N a 2 H P O 4 ⋅ 7 H 2 O Na_2HPO_4 \cdot 7H_2O N a 2 ​ H P O 4 ​ ⋅ 7 H 2 ​ O , N H 4 C l NH_4Cl N H 4 ​ Cl ) buffers the water at pH 7.2 and supplies essential phosphorus and nitrogen.

Magnesium Sulfate Solution: ( M g S O 4 ⋅ 7 H 2 O MgSO_4 \cdot 7H_2O M g S O 4 ​ ⋅ 7 H 2 ​ O ) supplies magnesium ions for bacterial enzymatic transfer.

Calcium Chloride Solution: ( C a C l 2 CaCl_2 C a C l 2 ​ ) provides essential calcium for cell wall structure.

Ferric Chloride Solution: ( F e C l 3 ⋅ 6 H 2 O FeCl_3 \cdot 6H_2O F e C l 3 ​ ⋅ 6 H 2 ​ O ) provides trace iron required for microbial respiratory cytochromes.

Dilution Water Quality Blank: An unseeded dilution water blank must be incubated alongside every batch. The DO depletion of the blank must not exceed 0.20 mg/L 0.20\text{ mg/L} 0.20 mg/L after 5 days. Depletion greater than 0.20 mg/L 0.20\text{ mg/L} 0.20 mg/L indicates organic contamination in the reagents, deionized water system, or glassware, invalidating all associated test runs.

Microbial Seed & Seed Correction

Samples that lack viable, acclimated microorganisms—such as disinfected (chlorinated/UV) secondary effluents, extreme pH industrial discharges, or boiled wastes—must be inoculated with an active biological seed (typically settled domestic primary effluent or commercial bacterial seed cultures):

Seed Control: Prepare a series of dilution water bottles containing varying seed volumes (e.g., 2, 4, and 6 mL) without sample to determine the DO depletion attributable strictly to the seed.

Seed Depletion Ratio ( S S S ): The seed correction factor is the DO depletion per mL of seed added: S = D O seed, initial − D O seed, final mL of seed in control bottle S = \frac{DO_{\text{seed, initial}} - DO_{\text{seed, final}}}{\text{mL of seed in control bottle}} S = mL of seed in control bottle D O seed, initial ​ − D O seed, final ​ ​

Test Validity Gates & GGA Standards

Under Standard Methods 5210B, a BOD determination is legally valid only if it satisfies three strict criteria:

Minimum DO Depletion Gate: The sample bottle must consume at least 2.0 mg/L 2.0\text{ mg/L} 2.0 mg/L of DO over the 5-day incubation period ( D O i − D O f ≥ 2.0 mg/L DO_i - DO_f \ge 2.0\text{ mg/L} D O i ​ − D O f ​ ≥ 2.0 mg/L ). Depletions < 2.0 mg/L < 2.0\text{ mg/L} < 2.0 mg/L exhibit high analytical noise and cannot be used.

Minimum Residual DO Gate: The sample bottle must contain at least 1.0 mg/L 1.0\text{ mg/L} 1.0 mg/L of DO remaining after 5 days ( D O f ≥ 1.0 mg/L DO_f \ge 1.0\text{ mg/L} D O f ​ ≥ 1.0 mg/L ). If residual DO drops below 1.0 mg/L 1.0\text{ mg/L} 1.0 mg/L , bacterial respiration becomes oxygen-limited or anoxic, under-measuring true organic demand.

Glucose-Glutamic Acid (GGA) Standard: An analytical check standard consisting of 150 mg/L 150\text{ mg/L} 150 mg/L reagent-grade glucose and 150 mg/L 150\text{ mg/L} 150 mg/L reagent-grade glutamic acid ( 300 mg/L 300\text{ mg/L} 300 mg/L total solids). A 2.0 % 2.0\% 2.0% dilution ( 6.0 mL 6.0\text{ mL} 6.0 mL of GGA in a 300 mL 300\text{ mL} 300 mL bottle) must yield an average 5-day BOD of 198 ± 30.5 mg/L 198 \pm 30.5\text{ mg/L} 198 ± 30.5 mg/L (acceptable window: 167.5 to 228.5 mg/L 167.5\text{ to } 228.5\text{ mg/L} 167.5 to 228.5 mg/L ) . Values outside this window indicate toxic inhibitory substances or weak, inactive microbial seed.

  • Mathematical Calculations
  • Unseeded BOD5 Formula

BOD 5 (mg/L) = D O i − D O f P \text{BOD}_5\text{ (mg/L)} = \frac{DO_i - DO_f}{P} BOD 5 ​ (mg/L) = P D O i ​ − D O f ​ ​

Where D O i DO_i D O i ​ is initial dissolved oxygen (mg/L), D O f DO_f D O f ​ is final dissolved oxygen on day 5 (mg/L), and P P P is the decimal sample dilution fraction ( P = sample volume (mL) / 300 mL P = \text{sample volume (mL)} / 300\text{ mL} P = sample volume (mL) /300 mL ). For example, for a 15 mL 15\text{ mL} 15 mL sample in a standard 300 mL 300\text{ mL} 300 mL BOD bottle, P = 15 / 300 = 0.05 P = 15 / 300 = 0.05 P = 15/300 = 0.05 .

Seeded BOD5 Formula

BOD 5 (mg/L) = ( D O i − D O f ) − ( S × V s ) P \text{BOD}_5\text{ (mg/L)} = \frac{(DO_i - DO_f) - (S \times V_s)}{P} BOD 5 ​ (mg/L) = P ( D O i ​ − D O f ​ ) − ( S × V s ​ ) ​

Where S S S is seed DO depletion per mL of seed added, and V s V_s V s ​ is the volume of seed (mL) added directly into the sample bottle.

Dissolved Oxygen Measurement Methods

Azide Modification of the Winkler Titration (Standard Methods 4500-O C):

Standard wet chemistry titration based on the oxidation of manganous ( M n 2 + Mn^{2+} M n 2 + ) to manganic ( M n 3 + Mn^{3+} M n 3 + or M n 4 + Mn^{4+} M n 4 + ) hydroxide precipitate by dissolved oxygen under alkaline conditions.

Reagents: Manganous sulfate ( M n S O 4 MnSO_4 M n S O 4 ​ ), alkaline-iodide-azide ( N a O H + K I + N a N 3 NaOH + KI + NaN_3 N a O H + K I + N a N 3 ​ ), and concentrated sulfuric acid ( H 2 S O 4 H_2SO_4 H 2 ​ S O 4 ​ ).

Role of Sodium Azide ( N a N 3 NaN_3 N a N 3 ​ ): Destroys nitrite ( N O 2 − NO_2^- N O 2 − ​ ) interference, which is prevalent in wastewater effluents. Without azide, nitrite reacts catalytically with iodide to continuously generate excess iodine, producing false high DO readings: 2 N a N 3 + 2 H N O 2 → 3 N 2 ↑ + N 2 O ↑ + 2 N a O H 2NaN_3 + 2HNO_2 \rightarrow 3N_2 \uparrow + N_2O \uparrow + 2NaOH 2 N a N 3 ​ + 2 H N O 2 ​ → 3 N 2 ​ ↑ + N 2 ​ O ↑ + 2 N a O H

Acidification dissolves the floc and oxidizes iodide ( I − I^- I − ) to free elemental iodine ( I 2 I_2 I 2 ​ ) in direct proportion to original dissolved oxygen. The solution is titrated with 0.0250 N 0.0250\text{ N} 0.0250 N sodium thiosulfate ( N a 2 S 2 O 3 Na_2S_2O_3 N a 2 ​ S 2 ​ O 3 ​ ) using starch indicator (blue to colorless endpoint). For a 200 mL 200\text{ mL} 200 mL sample, 1.0 mL 1.0\text{ mL} 1.0 mL of 0.0250 N N a 2 S 2 O 3 = 1.0 mg/L DO 0.0250\text{ N } Na_2S_2O_3 = 1.0\text{ mg/L DO} 0.0250 N N a 2 ​ S 2 ​ O 3 ​ = 1.0 mg/L DO .

Luminescent Dissolved Oxygen (LDO) / Optical Membrane Probe:

Utilizes a luminescent sensor cap containing an organometallic platinum or ruthenium dye excited by a blue LED.

Oxygen molecules quench the luminescence lifetime. The phase shift of the emitted red light is inversely proportional to dissolved oxygen partial pressure.

Operational Advantages: LDO sensors consume zero oxygen during measurement (no stirring or flow velocity required), require no electrolyte solutions or membrane replacements, and are completely unaffected by chemical poisoning from hydrogen sulfide ( H 2 S H_2S H 2 ​ S ), ammonia, or heavy metals.

2. Chemical Oxygen Demand (COD)

Chemical Oxygen Demand measures the total quantity of oxygen required to chemically oxidize organic and oxidizable inorganic matter in water using a powerful chemical oxidant under severe thermal and acidic conditions (Standard Methods 5220D Closed Reflux).

  • Digestion Chemistry & Reagent Roles [Sample + Digestion Reagents]
  • Oxidant: Potassium Dichromate (K2Cr2O7 in H2SO4)
  • Catalyst: Silver Sulfate (Ag2SO4)
  • Complexing Agent: Mercuric Sulfate (HgSO4)
  • │
  • ▼
  • [Closed Reflux Digestion]
  • Heated in sealed culture tubes at 150°C for 2.0 hours
  • Cr⁶⁺ (hexavalent, orange) is reduced to Cr³⁺ (trivalent, green)
  • │
  • ▼
  • [Quantification]
  • Spectrophotometric absorption at 600 nm (Cr³⁺) or 420 nm (Cr⁶⁺)
  • Direct concentration output in mg/L COD within 2.5 hours total time

Potassium Dichromate ( K 2 C r 2 O 7 K_2Cr_2O_7 K 2 ​ C r 2 ​ O 7 ​ ): Strong oxidant in boiling concentrated sulfuric acid ( H 2 S O 4 H_2SO_4 H 2 ​ S O 4 ​ ). Dichromate oxidizes nearly all organic carbon compounds to C O 2 CO_2 C O 2 ​ and H 2 O H_2O H 2 ​ O , while hexavalent chromium ( C r 6 + Cr^{6+} C r 6 + , bright orange) is reduced to trivalent chromium ( C r 3 + Cr^{3+} C r 3 + , deep green): C n H a O b + c C r 2 O 7 2 − + 8 c H + → n C O 2 + a + 8 c 2 H 2 O + 2 c C r 3 + C_n H_a O_b + c\,Cr_2O_7^{2-} + 8c\,H^+ \rightarrow n\,CO_2 + \frac{a + 8c}{2}\,H_2O + 2c\,Cr^{3+} C n ​ H a ​ O b ​ + c C r 2 ​ O 7 2 − ​ + 8 c H + → n C O 2 ​ + 2 a + 8 c ​ H 2 ​ O + 2 c C r 3 +

Silver Sulfate ( A g 2 S O 4 Ag_2SO_4 A g 2 ​ S O 4 ​ ): Functions as an indispensable catalyst. Straight-chain aliphatic hydrocarbons, volatile fatty acids, and alcohols resist dichromate attack; silver ions catalyze the rapid electron transfer required to oxidize these refractory chains.

Mercuric Sulfate ( H g S O 4 HgSO_4 H g S O 4 ​ ): Eliminates chloride interference. Municipal and industrial wastewaters contain chloride ions ( C l − Cl^- C l − ), which dichromate oxidizes to free chlorine gas ( C l 2 Cl_2 C l 2 ​ ), consuming oxidant and generating massive false high COD readings. Mercuric sulfate binds chloride at a strict 10:1 ratio ( H g S O 4 : C l − HgSO_4 : Cl^- H g S O 4 ​ : C l − ) to form stable, soluble mercuric chloride complexes ( H g C l 4 2 − HgCl_4^{2-} H g C l 4 2 − ​ ), suppressing chloride interference up to 2 , 000 mg/L 2,000\text{ mg/L} 2 , 000 mg/L .

Digestion Conditions: Samples are incubated in tightly capped borosilicate culture vials inside a preheated digestion block at 150 ± 2 ∘ C 150 \pm 2^\circ\text{C} 150 ± 2 ∘ C for precisely 2 hours .

COD vs. BOD Comparison & Operational Correlation

Analytical Metric Chemical Oxygen Demand (COD) Biochemical Oxygen Demand (BOD5)

Mechanism Strong chemical oxidation ( K 2 C r 2 O 7 K_2Cr_2O_7 K 2 ​ C r 2 ​ O 7 ​ in boiling H 2 S O 4 H_2SO_4 H 2 ​ S O 4 ​ ) Biological oxidation by live aerobic heterotrophic bacteria

Turnaround Time 2.5 hours total (rapid turnaround) 5 days (inherent incubation delay)

Compounds Oxidized Biodegradable organics + non-biodegradable organics (cellulose, lignin, tannins) + reduced inorganics Only biodegradable organic carbon compounds readily broken down by bacteria

Application Real-time plant process control, industrial surcharge billing NPDES discharge permit compliance, stream assimilative capacity modeling

Interference Vulnerability Chloride ( C l − Cl^- C l − ) oxidation (masked by H g S O 4 HgSO_4 H g S O 4 ​ ) Toxic heavy metals, biocides, chlorine, cold temperature, nitrifiers

The Municipal COD:BOD Ratio: In raw municipal domestic wastewater, the typical C O D : BOD 5 COD:\text{BOD}_5 CO D : BOD 5 ​ ratio ranges between 1.5 : 1 and 2.5 : 1 1.5:1\text{ and } 2.5:1 1.5 : 1 and 2.5 : 1 . In well-oxidized, treated secondary effluent, the ratio climbs to 3 : 1 to 5 : 1 3:1\text{ to } 5:1 3 : 1 to 5 : 1 because bacteria have consumed the biodegradable fraction, leaving biologically refractory organics behind.

Troubleshooting Significance: If an operator observes the influent C O D : BOD 5 COD:\text{BOD}_5 CO D : BOD 5 ​ ratio suddenly spike from 2 : 1 2:1 2 : 1 to > 3.5 : 1 > 3.5:1 > 3.5 : 1 , it signals an illegal industrial discharge containing toxic compounds that inhibit biological BOD uptake, or refractory industrial wastes (e.g., plastics, petrochemicals, textile dyes) requiring industrial pretreatment enforcement.

3. Total Suspended Solids (TSS) & Volatile Suspended Solids (VSS)

Solids testing provides the primary quantitative basis for assessing clarifier efficiency, calculating sludge inventory, establishing Mean Cell Residence Time (MCRT), and ensuring NPDES permit compliance.

Gravimetric TSS Procedure (Standard Methods 2540D)

Total Suspended Solids represents the non-filterable particulate residue retained on a standardized glass fiber filter and dried to constant weight at 103 ∘ C to 105 ∘ C 103^\circ\text{C to } 105^\circ\text{C} 10 3 ∘ C to 10 5 ∘ C .

Filter Preparation:

Place a binderless borosilicate glass fiber filter disk (Whatman 934-AH, nominal pore size 1.5 μ m 1.5\ \mu\text{m} 1.5 μ m ) on a vacuum filtration apparatus.

Apply vacuum and wash the filter with three successive 20 mL 20\text{ mL} 20 mL volumes of reagent-grade water to remove loose glass fibers.

Transfer the filter to an aluminum weighing dish and dry in an oven at 103 − 105 ∘ C 103-105^\circ\text{C} 103 − 10 5 ∘ C for at least 1 hour .

Cool in a desiccator containing active indicating silica gel to room temperature. Weigh on a calibrated analytical balance to the nearest 0.1 mg 0.1\text{ mg} 0.1 mg ( 0.0001 g 0.0001\text{ g} 0.0001 g ) to establish the tare weight ( W tare W_{\text{tare}} W tare ​ ).

Sample Filtration:

Thoroughly mix the sample container by vigorous inversion.

Measure a known volume of sample ( V V V , in mL)—typically 25 to 50 mL for raw wastewater, 50 to 100 mL for primary effluent, and 200 to 1,000 mL for final secondary effluent—aiming to yield between 2.5 and 200 mg 2.5\text{ and } 200\text{ mg} 2.5 and 200 mg of dry dried residue .

Filter the sample under vacuum. Rinse the graduated cylinder and filter funnel walls with three successive 10 mL 10\text{ mL} 10 mL portions of reagent water, allowing complete drainage between rinses to remove dissolved salts.

Drying & Weighing:

Dry the filter in a drying oven at 103 − 105 ∘ C 103-105^\circ\text{C} 103 − 10 5 ∘ C for at least 1 hour .

Transfer to a desiccator, cool to room temperature, and weigh ( W dry W_{\text{dry}} W dry ​ ). Repeat the cycle of drying, desiccating, and weighing until the weight change is less than 0.5 mg 0.5\text{ mg} 0.5 mg (constant weight).

TSS Mathematical Calculation

TSS (mg/L) = ( W dry, g − W tare, g ) × 1 , 000 , 000 Sample Volume (mL) \text{TSS (mg/L)} = \frac{(W_{\text{dry, g}} - W_{\text{tare, g}}) \times 1,000,000}{\text{Sample Volume (mL)}} TSS (mg/L) = Sample Volume (mL) ( W dry, g ​ − W tare, g ​ ) × 1 , 000 , 000 ​

Where ( W dry − W tare ) (W_{\text{dry}} - W_{\text{tare}}) ( W dry ​ − W tare ​ ) is the net dry residue mass in grams, and 1 , 000 , 000 1,000,000 1 , 000 , 000 converts grams to milligrams and milliliters to liters ( 1 , 000 mg/g × 1 , 000 mL/L 1,000\text{ mg/g} \times 1,000\text{ mL/L} 1 , 000 mg/g × 1 , 000 mL/L ). For example, if a 100 mL 100\text{ mL} 100 mL sample produces a tare weight of 1.5320 g 1.5320\text{ g} 1.5320 g and a dried weight of 1.5356 g 1.5356\text{ g} 1.5356 g :

TSS = ( 1.5356 − 1.5320 ) × 1 , 000 , 000 100 = 0.0036 × 1 , 000 , 000 100 = 36.0 mg/L \text{TSS} = \frac{(1.5356 - 1.5320) \times 1,000,000}{100} = \frac{0.0036 \times 1,000,000}{100} = 36.0\text{ mg/L} TSS = 100 ( 1.5356 − 1.5320 ) × 1 , 000 , 000 ​ = 100 0.0036 × 1 , 000 , 000 ​ = 36.0 mg/L

Volatile Suspended Solids (VSS) (Standard Methods 2540E)

Volatile Suspended Solids measures the organic (biological) fraction of the suspended solids. After recording the dry TSS weight, the filter disk is transferred into a muffle furnace at 550 ± 50 ∘ C 550 \pm 50^\circ\text{C} 550 ± 5 0 ∘ C for 15 to 20 minutes :

Combustion: At 550°C, all organic biological carbon burns off as C O 2 CO_2 C O 2 ​ and water vapor, leaving behind inert mineral ash (Fixed Suspended Solids, FSS).

Weighing: Partially cool the filter in air, place in a desiccator to reach room temperature, and weigh on the analytical balance ( W ash W_{\text{ash}} W ash ​ ).

VSS and FSS Formulas

VSS (mg/L) = ( W dry, g − W ash, g ) × 1 , 000 , 000 Sample Volume (mL) \text{VSS (mg/L)} = \frac{(W_{\text{dry, g}} - W_{\text{ash, g}}) \times 1,000,000}{\text{Sample Volume (mL)}} VSS (mg/L) = Sample Volume (mL) ( W dry, g ​ − W ash, g ​ ) × 1 , 000 , 000 ​

FSS (mg/L) = ( W ash, g − W tare, g ) × 1 , 000 , 000 Sample Volume (mL) \text{FSS (mg/L)} = \frac{(W_{\text{ash, g}} - W_{\text{tare, g}}) \times 1,000,000}{\text{Sample Volume (mL)}} FSS (mg/L) = Sample Volume (mL) ( W ash, g ​ − W tare, g ​ ) × 1 , 000 , 000 ​

Process Control Application: In an activated sludge basin, Mixed Liquor Suspended Solids (MLSS) includes both living biomass and inert mineral grit. Mixed Liquor Volatile Suspended Solids ( MLVSS ) represents the active biological mass responsible for treating wastewater. The MLVSS / MLSS \text{MLVSS} / \text{MLSS} MLVSS / MLSS ratio in healthy municipal activated sludge systems ranges between 0.70 and 0.85 0.70\text{ and } 0.85 0.70 and 0.85 (70% to 85%) . A decline below 70% indicates severe accumulation of inorganic silt, clay, or chemical precipitants, signaling insufficient solids wasting.

4. Settleable Solids & Imhoff Cone Test

Settleable solids quantifies the volume of suspended solids that settle out of a liquid sample under still, gravity conditions over a 1-hour period. It is reported in mL/L \text{mL/L} mL/L (Standard Methods 2540F).

Procedure

Thoroughly mix the wastewater sample.

Fill a graduated 1.0-liter transparent Imhoff cone exactly to the 1.0-liter mark.

Allow the liquid to settle undisturbed for 45 minutes .

Gently run a glass stirring rod along the inside conical walls, or gently rotate the cone between hands through a 45-degree arc, to dislodge solids clinging to the sloped walls. Crucial rule: Do not disturb or stir the settled sludge blanket at the cone's apex.

Allow the sample to settle for an additional 15 minutes (total settling time: 60 minutes ).

Read the volume of settled solids directly from the graduated markings at the cone tip, reporting as mL/L \text{mL/L} mL/L .

Operational Applications

Raw Wastewater: Typical municipal domestic raw wastewater contains 5 to 15 mL/L 5\text{ to } 15\text{ mL/L} 5 to 15 mL/L settleable solids.

Primary Clarifier Efficiency: Primary clarifiers are designed to remove settleable solids before secondary biological treatment. Primary effluent should contain < 0.5 to 1.0 mL/L < 0.5\text{ to } 1.0\text{ mL/L} < 0.5 to 1.0 mL/L . Primary clarifier settleable solids removal efficiency must exceed 90% to 95% ; lower removal indicates short-circuiting, excessive hydraulic overflow rates, or damaged sludge collector flights.

Loading diagram... Wastewater Solids & Oxygen Demand Analytical Classifications