Study guide
13.2 The Pounds Formula, Chemical Feed Rates & Solution Concentration Calculations
Alabama Water/Wastewater Operator Certification Study Guide Exam
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: Alabama Regulations, Certification, Exams & Utility Administration
1.1 ADEM Division 335-10-1: Facility Classifications, Grades & Staffing Rules 1.2 Becoming Certified in Alabama: Exam Application, Operator Intern Status, Experience, Renewal & CEHs 1.3 Environmental Compliance, SDWA, Clean Water Act & NPDES Permits 1.4 Alabama's PSI-Delivered WPI Exams: Format, Grade Crosswalk & Need-to-Know Blueprints 1.5 ADEM Drinking-Water Operating Rules (Division 335-7): Control Tests, Residuals, Pressure, Cross-Connections & Records 1.6 Utility Administration: SOPs, Records, Security, Cybersecurity, Emergency Planning & Supervision
2 Chapter 2: Source Water, Wells, Coagulation, Filtration & Membranes
2.1 Source Water Hydrology, Groundwater vs. Surface Water & Protection 2.2 Coagulation Chemistry, Coagulants & Rapid Mixing Mechanics 2.3 Flocculation Basin Design, Clarification & Sedimentation 2.4 Granular Media Filtration, Head Loss & Backwash Protocols 2.5 Membrane Filtration: MF, UF, NF & RO Operation, Integrity Testing and Cleaning 2.6 Wells & Groundwater Systems: Construction, Pumps, Testing and Sanitary Protection (ADEM 335-7-5)
3 Chapter 3: Water Disinfection, Chemical Addition, Stabilization & Residuals
3.1 Chlorination Chemistry, Breakpoint Chlorination & Residuals 3.2 Disinfection Byproducts (DBPs), Stage 1/2 Rules & CT Compliance 3.3 Corrosion Control, Lead and Copper Rule & Fluoridation 3.4 Iron/Manganese Removal, Water Softening & Taste/Odor Control 3.5 Water Treatment Residuals: Sludge, Backwash Recycle & Plant Discharges
4 Chapter 4: Wastewater Preliminary & Primary Treatment
4.1 Wastewater Characteristics, Screening, Shredding & Grit Removal 4.2 Primary Sedimentation Basins, Scum Removal & Clarifier Performance
5 Chapter 5: Secondary Biological Treatment: Activated Sludge
5.1 Activated Sludge Microbiology, Basin Configurations & Aeration Systems 5.2 Process Control: F/M Ratio, MCRT/SRT & Sludge Settling Characteristics 5.3 Operational Troubleshooting (Bulking, Foaming, Pin Floc) & Process Modifications
6 Chapter 6: Fixed-Film Treatment, Lagoons, Nutrient Removal, Tertiary Filtration & Disinfection
6.1 Trickling Filters & Rotating Biological Contactors (RBCs) 6.2 Waste Stabilization Ponds, Aerated Lagoons & Alabama Grade I Lagoon Operations 6.3 Biological Nutrient Removal: Nitrification, Denitrification & Phosphorus Removal 6.4 Tertiary Filtration & Membrane Bioreactors (MBRs) 6.5 Wastewater Disinfection & Dechlorination: Chlorine, UV and Ozone
7 Chapter 7: Sludge Treatment, Biosolids & Odor Control
7.1 Sludge Thickening, Aerobic Digestion & Anaerobic Digestion 7.2 Mechanical Dewatering, Polymer Conditioning & EPA 503 Biosolids Regulations 7.3 Odor Control & Wastewater Chemical Addition
8 Chapter 8: Water Distribution Systems, Installation, Metering & Water Loss
8.1 Distribution Piping Materials, Valves & Finished Water Storage Facilities 8.2 Water Main Flushing, Disinfection Protocols (AWWA C651) & Water Quality Maintenance 8.3 Distribution Hydraulics, Pressure Control & Cross-Connection Prevention 8.4 Main & Service Installation, Tapping, Repair and Utility Locating (Alabama 811) 8.5 Meters, Water Loss Control, Asset Management & Customer Service
9 Chapter 9: Wastewater Collection Systems, Lift Stations & Sewer Maintenance
9.1 Gravity Collection Networks, Manhole Construction & Self-Cleansing Velocity Standards 9.2 Wastewater Lift Stations, Submersible Pumps, Force Mains & Inflow/Infiltration (I&I) 9.3 Sewer Cleaning, CCTV Inspection & SSO Response
10 Chapter 10: Laboratory Procedures, Sampling & Environmental Compliance
10.1 Drinking Water Laboratory Analysis: Turbidity, pH, Alkalinity & Coliform Testing 10.2 Wastewater Laboratory Testing: BOD5, COD, Total Suspended Solids & Settleability 10.3 Representative Sampling Protocols, Preservation, Chain of Custody & QA/QC
11 Chapter 11: Plant Equipment, Pumps, Motors & Instrumentation
11.1 Centrifugal and Positive Displacement Pumps: Operation, Cavitation & Packing/Seals 11.2 Electric Motors, Variable Frequency Drives, Flow Meters & SCADA Systems
12 Chapter 12: Safety: Chemicals, Confined Spaces & Field Hazards
12.1 Chemical Safety: Chlorine Gas Emergency Handling (Kits A & B) & Hydrogen Sulfide (H2S) Hazards 12.2 Permit-Required Confined Space Entry, Lockout/Tagout (LOTO) & Personal Protective Equipment 12.3 Field Safety: Work-Zone Traffic Control, Electrical Hazards, Fall Protection & Hazard Communication
13 Chapter 13: Water & Wastewater Mathematics: Hydraulics, Chemical Feed & Pumping
13.1 Flow Conversions, Geometry, Tank Volume & Detention Time Calculations 13.2 The Pounds Formula, Chemical Feed Rates & Solution Concentration Calculations 13.3 Pumping Math: Total Dynamic Head, Horsepower, Efficiency & Power Cost
14 Chapter 14: Water & Wastewater Mathematics: Treatment Process Calculations
14.1 Clarifier Surface Overflow Rate, Weir Loading & Granular Filter Loading Rates 14.2 Biological Calculations: F/M Ratio, MCRT Solids Balance & Sludge Volume Index (SVI)
13.2 The Pounds Formula, Chemical Feed Rates & Solution Concentration Calculations
Key Takeaways Explain This Topic AI
The fundamental Pounds Formula determines daily mass dosing: Chemical Feed (lbs/day) = Flow (MGD) × Dosage (mg/L) × 8.34 lbs/gal \text{Chemical Feed (lbs/day)} = \text{Flow (MGD)} \times \text{Dosage (mg/L)} \times 8.34\text{ lbs/gal} Chemical Feed (lbs/day) = Flow (MGD) × Dosage (mg/L) × 8.34 lbs/gal .
Commercial chemicals with < 100 % <100\% < 100% purity require upward mass adjustment: Commercial Chemical (lbs/day) = Pure Chemical (lbs/day) / Decimal Purity \text{Commercial Chemical (lbs/day)} = \text{Pure Chemical (lbs/day)} / \text{Decimal Purity} Commercial Chemical (lbs/day) = Pure Chemical (lbs/day) / Decimal Purity .
Liquid chemical feed accounting requires Specific Gravity: Weight per Gallon = SG × 8.34 lbs/gal \text{Weight per Gallon} = \text{SG} \times 8.34\text{ lbs/gal} Weight per Gallon = SG × 8.34 lbs/gal , and active pounds per gallon equals total solution weight multiplied by active decimal concentration.
Chemical metering pump calibration converts daily volume to pumping rate: Feed Rate (mL/min) = [ Feed Rate (gpd) × 3 , 785 mL/gal ] / 1 , 440 min/day \text{Feed Rate (mL/min)} = [\text{Feed Rate (gpd)} \times 3,785\text{ mL/gal}] / 1,440\text{ min/day} Feed Rate (mL/min) = [ Feed Rate (gpd) × 3 , 785 mL/gal ] /1 , 440 min/day , or approximately gpd × 2.6285 \text{gpd} \times 2.6285 gpd × 2.6285 .
Disinfection mass balance dictates Dosage = Demand + Residual \text{Dosage} = \text{Demand} + \text{Residual} Dosage = Demand + Residual , while chemical day-tank dilution follows the conservation of mass formula C 1 V 1 = C 2 V 2 C_1 V_1 = C_2 V_2 C 1 V 1 = C 2 V 2 .
Last updated: October 2026
13.2 The Pounds Formula, Chemical Feed Rates & Solution Concentration Calculations
Accurate chemical dosing is vital for both regulatory compliance and plant economic efficiency. Underdosing coagulants, disinfectants, or pH adjusters risks pathogen breakthrough, permit violations, or corrosive finished water. Overdosing wastes operating funds, accelerates equipment scaling, and can generate hazardous concentrations of disinfection byproducts (DBPs) such as trihalomethanes (THMs) and haloacetic acids (HAAs). Water and wastewater operators must be completely proficient in calculating chemical feed rates for gaseous, dry, and liquid chemicals across variable plant flows.
1. The Fundamental Pounds Equation (Chemical Dosage Formula)
The Pounds Equation is the most widely applied mathematical formula in water and wastewater operations. It determines the mass of pure chemical required per day to achieve a target concentration in a given volume of treated water: Chemical Feed Rate (lbs/day) = Flow Rate (MGD) × Dosage (mg/L) × 8.34 lbs/gallon \text{Chemical Feed Rate (lbs/day)} = \text{Flow Rate (MGD)} \times \text{Dosage (mg/L)} \times 8.34\text{ lbs/gallon} Chemical Feed Rate (lbs/day) = Flow Rate (MGD) × Dosage (mg/L) × 8.34 lbs/gallon
Dimensional Analysis of the 8.34 Factor
Many operators wonder why multiplying Million Gallons per Day by milligrams per liter directly produces pounds per day . The dimensional derivation proves this relationship:
One liter of pure water has a mass of 1,000 grams, or 1 , 000 , 000 milligrams 1,000,000\text{ milligrams} 1 , 000 , 000 milligrams . Therefore, 1 milligram per liter (mg/L) 1\text{ milligram per liter (mg/L)} 1 milligram per liter (mg/L) represents 1 part per million (ppm) by mass: 1 mg/L = 1 lb of chemical 1 , 000 , 000 lbs of water 1\text{ mg/L} = \frac{1\text{ lb of chemical}}{1,000,000\text{ lbs of water}} 1 mg/L = 1 , 000 , 000 lbs of water 1 lb of chemical
One gallon of water weighs 8.34 lbs 8.34\text{ lbs} 8.34 lbs . One million gallons of water weighs: 1 , 000 , 000 gallons × 8.34 lbs/gal = 8 , 340 , 000 lbs of water 1,000,000\text{ gallons} \times 8.34\text{ lbs/gal} = 8,340,000\text{ lbs of water} 1 , 000 , 000 gallons × 8.34 lbs/gal = 8 , 340 , 000 lbs of water
Combining the terms for a flow of 1.0 MGD treated at 1.0 mg/L: lbs/day = ( 1.0 MGD × 8 , 340 , 000 lbs water 1 MG ) × ( 1 lb chemical 1 , 000 , 000 lbs water ) = 8.34 lbs chemical/day \text{lbs/day} = \left(1.0\text{ MGD} \times \frac{8,340,000\text{ lbs water}}{1\text{ MG}}\right) \times \left(\frac{1\text{ lb chemical}}{1,000,000\text{ lbs water}}\right) = 8.34\text{ lbs chemical/day} lbs/day = ( 1.0 MGD × 1 MG 8 , 340 , 000 lbs water ) × ( 1 , 000 , 000 lbs water 1 lb chemical ) = 8.34 lbs chemical/day
The constant 8.34 8.34 8.34 incorporates the density of water and the metric-to-English dimensional cancellation.
Algebraic Rearrangements (Davidson's Pie / Box Method)
Operators frequently utilize the Davidson Pie Method as a visual calculation aid. A circle is divided horizontally; the top half contains Chemical Mass (lbs/day) , and the bottom half is divided into three wedges: Flow (MGD) , Dosage (mg/L) , and the constant 8.34 .
- Top Half: Mass Rate Chemical Feed (lbs/day)
- Bottom Wedges (Factors) Flow (MGD) × \times × Dosage (mg/L) × \times × 8.34 lbs/gal
By covering the desired variable, the required mathematical operation is revealed:
Solving for Feed Rate: Feed Rate (lbs/day) = Flow (MGD) × Dosage (mg/L) × 8.34 \text{Feed Rate (lbs/day)} = \text{Flow (MGD)} \times \text{Dosage (mg/L)} \times 8.34 Feed Rate (lbs/day) = Flow (MGD) × Dosage (mg/L) × 8.34
Solving for Dosage: Dosage (mg/L) = Feed Rate (lbs/day) Flow (MGD) × 8.34 \text{Dosage (mg/L)} = \frac{\text{Feed Rate (lbs/day)}}{\text{Flow (MGD)} \times 8.34} Dosage (mg/L) = Flow (MGD) × 8.34 Feed Rate (lbs/day)
Solving for Flow Capacity: Flow (MGD) = Feed Rate (lbs/day) Dosage (mg/L) × 8.34 \text{Flow (MGD)} = \frac{\text{Feed Rate (lbs/day)}}{\text{Dosage (mg/L)} \times 8.34} Flow (MGD) = Dosage (mg/L) × 8.34 Feed Rate (lbs/day)
Batch Dosing Variation: When calculating the chemical mass needed to treat a static, standing volume (e.g., disinfected storage tank, clarifier, or pipeline) rather than a flowing stream, substitute Tank Volume in Million Gallons (MG) for Flow (MGD): Chemical Required (lbs) = Volume (MG) × Dosage (mg/L) × 8.34 lbs/gal \text{Chemical Required (lbs)} = \text{Volume (MG)} \times \text{Dosage (mg/L)} \times 8.34\text{ lbs/gal} Chemical Required (lbs) = Volume (MG) × Dosage (mg/L) × 8.34 lbs/gal
2. Chemical Purity and Active Ingredient Corrections
The fundamental pounds formula calculates the weight of 100% pure active chemical required. However, many commercial water treatment chemicals are delivered in impure solid forms, aqueous blends, or hydration complexes:
Calcium Hypochlorite (HTH): Solid granules or tablets containing approximately 65 % available chlorine 65\%\text{ available chlorine} 65% available chlorine ( 0.65 0.65 0.65 decimal purity).
Dry Alum (Aluminum Sulfate): Typically contains 17 % available A l 2 O 3 17\%\text{ available } Al_2O_3 17% available A l 2 O 3 , with bulk dry product commercial purity rated at approximately 85 % to 90 % 85\%\text{ to } 90\% 85% to 90% .
Quicklime ( C a O CaO C a O ): Approximately 90 % available C a O 90\%\text{ available } CaO 90% available C a O ; Hydrated Lime ( C a ( O H ) 2 Ca(OH)_2 C a ( O H ) 2 ): Approximately 95 % 95\% 95% .
Because the commercial product is not pure active chemical, the operator must feed a larger total weight of the commercial product to deliver the required active pounds: Commercial Chemical Feed Rate (lbs/day) = Pure Chemical Calculated (lbs/day) Decimal Purity \text{Commercial Chemical Feed Rate (lbs/day)} = \frac{\text{Pure Chemical Calculated (lbs/day)}}{\text{Decimal Purity}} Commercial Chemical Feed Rate (lbs/day) = Decimal Purity Pure Chemical Calculated (lbs/day)
Common Sense Verification: Dividing by a decimal fraction (a number less than 1.0) always produces a result larger than the starting number. If your calculated commercial feed rate is smaller than your pure active requirement, you mistakenly multiplied instead of dividing.
Worked Example: Commercial Dry Chemical Feed
Problem Statement: A water treatment plant treats 4.2 MGD. The coagulation jar test establishes an optimum alum dosage of 22 mg/L. The bulk dry alum delivered has an active chemical purity of 85% (0.85). Calculate the daily feed rate of commercial alum required in pounds per day.
Step 1: Calculate the pure alum requirement using the pounds formula. Pure Alum (lbs/day) = 4.2 MGD × 22 mg/L × 8.34 lbs/gal = 770.616 lbs/day \text{Pure Alum (lbs/day)} = 4.2\text{ MGD} \times 22\text{ mg/L} \times 8.34\text{ lbs/gal} = 770.616\text{ lbs/day} Pure Alum (lbs/day) = 4.2 MGD × 22 mg/L × 8.34 lbs/gal = 770.616 lbs/day
Step 2: Correct for the 85% chemical purity. Commercial Alum (lbs/day) = 770.616 lbs/day 0.85 = 906.607 lbs/day ≈ 907 lbs/day \text{Commercial Alum (lbs/day)} = \frac{770.616\text{ lbs/day}}{0.85} = 906.607\text{ lbs/day} \approx 907\text{ lbs/day} Commercial Alum (lbs/day) = 0.85 770.616 lbs/day = 906.607 lbs/day ≈ 907 lbs/day
3. Liquid Chemical Feed Calculations & Specific Gravity
Many municipal treatment facilities utilize liquid chemicals rather than dry powders or gaseous chlorine to eliminate dust hazards and gas leak risks. Common liquid chemicals include:
Sodium Hypochlorite ( N a O C l NaOCl N a OCl ): Delivered as a liquid solution at concentrations between 10 % 10\% 10% and 15 % 15\% 15% available chlorine.
Liquid Alum: Typically supplied as a 48 % to 50 % 48\%\text{ to } 50\% 48% to 50% aqueous solution.
Ferric Chloride ( F e C l 3 FeCl_3 F e C l 3 ): Supplied as a 35 % to 42 % 35\%\text{ to } 42\% 35% to 42% solution.
Sodium Hydroxide (Caustic Soda, N a O H NaOH N a O H ): Commonly delivered as a 25 % or 50 % 25\%\text{ or } 50\% 25% or 50% solution.
Specific Gravity ( S G SG SG )
Liquid chemical solutions are denser than plain water. The Specific Gravity ( S G SG SG ) is the ratio of the liquid chemical's density to the density of water ( 8.34 lbs/gal 8.34\text{ lbs/gal} 8.34 lbs/gal ): Weight of 1 Gallon of Chemical Solution (lbs/gal) = Specific Gravity × 8.34 lbs/gal \text{Weight of 1 Gallon of Chemical Solution (lbs/gal)} = \text{Specific Gravity} \times 8.34\text{ lbs/gal} Weight of 1 Gallon of Chemical Solution (lbs/gal) = Specific Gravity × 8.34 lbs/gal
Active Ingredient Mass per Gallon
To find the actual weight of the active therapeutic chemical contained in each gallon of bulk liquid: Active Chemical Weight (lbs/gal) = Specific Gravity × 8.34 lbs/gal × Decimal Concentration \text{Active Chemical Weight (lbs/gal)} = \text{Specific Gravity} \times 8.34\text{ lbs/gal} \times \text{Decimal Concentration} Active Chemical Weight (lbs/gal) = Specific Gravity × 8.34 lbs/gal × Decimal Concentration
Liquid Feed Rate Formulas
Once the pure active pounds per day are calculated from the pounds formula, the required liquid volume feed rate is: Liquid Feed Rate (gal/day) = Pure Chemical Required (lbs/day) Active Chemical Weight per Gallon (lbs/gal) \text{Liquid Feed Rate (gal/day)} = \frac{\text{Pure Chemical Required (lbs/day)}}{\text{Active Chemical Weight per Gallon (lbs/gal)}} Liquid Feed Rate (gal/day) = Active Chemical Weight per Gallon (lbs/gal) Pure Chemical Required (lbs/day)
Chemical metering pumps (diaphragm or peristaltic pumps) are calibrated in milliliters per minute ( mL/min ) or gallons per hour ( gph ): Liquid Feed Rate (gph) = Feed Rate (gal/day) 24 hr/day \text{Liquid Feed Rate (gph)} = \frac{\text{Feed Rate (gal/day)}}{24\text{ hr/day}} Liquid Feed Rate (gph) = 24 hr/day Feed Rate (gal/day) Liquid Feed Rate (mL/min) = Feed Rate (gal/day) × 3 , 785 mL/gallon 1 , 440 minutes/day = Feed Rate (gal/day) × 2.6285 \text{Liquid Feed Rate (mL/min)} = \frac{\text{Feed Rate (gal/day)} \times 3,785\text{ mL/gallon}}{1,440\text{ minutes/day}} = \text{Feed Rate (gal/day)} \times 2.6285 Liquid Feed Rate (mL/min) = 1 , 440 minutes/day Feed Rate (gal/day) × 3 , 785 mL/gallon = Feed Rate (gal/day) × 2.6285
Worked Example: Sodium Hypochlorite Metering Pump Sizing
Problem Statement: An operator must disinfect a finished water flow of 3.0 MGD with a target free chlorine dosage of 2.4 mg/L. The utility feeds commercial liquid sodium hypochlorite containing 12.5% available chlorine with a specific gravity of 1.20. Determine:
The required active chlorine in lbs/day.
The weight of active chlorine per gallon of solution.
The liquid feed rate in gallons per day (gpd).
The metering pump calibration rate in milliliters per minute (mL/min).
Step 1: Calculate active chlorine required per day. Active C l 2 (lbs/day) = 3.0 MGD × 2.4 mg/L × 8.34 lbs/gal = 60.048 lbs/day \text{Active } Cl_2\text{ (lbs/day)} = 3.0\text{ MGD} \times 2.4\text{ mg/L} \times 8.34\text{ lbs/gal} = 60.048\text{ lbs/day} Active C l 2 (lbs/day) = 3.0 MGD × 2.4 mg/L × 8.34 lbs/gal = 60.048 lbs/day
Step 2: Determine total weight of one gallon and active chlorine content. Weight of 1 gallon of solution = 1.20 × 8.34 lbs/gal = 10.008 lbs/gal \text{Weight of 1 gallon of solution} = 1.20 \times 8.34\text{ lbs/gal} = 10.008\text{ lbs/gal} Weight of 1 gallon of solution = 1.20 × 8.34 lbs/gal = 10.008 lbs/gal Active C l 2 per gallon = 10.008 lbs/gal × 0.125 = 1.251 lbs C l 2 / gal \text{Active } Cl_2\text{ per gallon} = 10.008\text{ lbs/gal} \times 0.125 = 1.251\text{ lbs } Cl_2/\text{gal} Active C l 2 per gallon = 10.008 lbs/gal × 0.125 = 1.251 lbs C l 2 / gal
Step 3: Calculate liquid feed rate in gallons per day. Liquid Feed Rate (gal/day) = 60.048 lbs C l 2 / day 1.251 lbs C l 2 / gal = 48.00 gal/day \text{Liquid Feed Rate (gal/day)} = \frac{60.048\text{ lbs } Cl_2/\text{day}}{1.251\text{ lbs } Cl_2/\text{gal}} = 48.00\text{ gal/day} Liquid Feed Rate (gal/day) = 1.251 lbs C l 2 / gal 60.048 lbs C l 2 / day = 48.00 gal/day
Step 4: Convert feed rate to mL/min for calibration. Feed Rate (mL/min) = 48.00 gal/day × 3 , 785 mL/gal 1 , 440 min/day = 181 , 680 1 , 440 = 126.17 mL/min ≈ 126.2 mL/min \text{Feed Rate (mL/min)} = \frac{48.00\text{ gal/day} \times 3,785\text{ mL/gal}}{1,440\text{ min/day}} = \frac{181,680}{1,440} = 126.17\text{ mL/min} \approx 126.2\text{ mL/min} Feed Rate (mL/min) = 1 , 440 min/day 48.00 gal/day × 3 , 785 mL/gal = 1 , 440 181 , 680 = 126.17 mL/min ≈ 126.2 mL/min
4. Dry Chemical Feeder Calibration & Catch Testing
Volumetric and gravimetric dry chemical feeders (screw, belt, or oscillating hopper feeders) must be physically calibrated by performing a catch-and-weigh test at various feeder dial settings. An operator catches the dry chemical discharged into a tare-weighed container for an exact time period and weighs the sample.
Catch-and-Weigh Equations Feed Rate (grams/minute) = Grams Caught Catch Time (minutes) \text{Feed Rate (grams/minute)} = \frac{\text{Grams Caught}}{\text{Catch Time (minutes)}} Feed Rate (grams/minute) = Catch Time (minutes) Grams Caught
To convert grams per minute to operational field units ( 1 pound = 453.6 grams ≈ 454 grams 1\text{ pound} = 453.6\text{ grams} \approx 454\text{ grams} 1 pound = 453.6 grams ≈ 454 grams ): Feed Rate (lbs/day) = Grams/min × 1 , 440 min/day 453.6 grams/lb \text{Feed Rate (lbs/day)} = \frac{\text{Grams/min} \times 1,440\text{ min/day}}{453.6\text{ grams/lb}} Feed Rate (lbs/day) = 453.6 grams/lb Grams/min × 1 , 440 min/day Feed Rate (lbs/hour) = Feed Rate (lbs/day) 24 hr/day = Grams/min × 60 min/hr 453.6 grams/lb \text{Feed Rate (lbs/hour)} = \frac{\text{Feed Rate (lbs/day)}}{24\text{ hr/day}} = \frac{\text{Grams/min} \times 60\text{ min/hr}}{453.6\text{ grams/lb}} Feed Rate (lbs/hour) = 24 hr/day Feed Rate (lbs/day) = 453.6 grams/lb Grams/min × 60 min/hr
Worked Example: Dry Feeder Calibration
Problem Statement: An operator tests a gravimetric dry lime feeder set at 45% stroke. A clean plastic catch bucket weighs 320 grams empty. After catching dry lime for exactly 4.0 minutes, the bucket and lime weigh 880 grams. What is the feeder output in pounds per day?
Step 1: Determine the net weight of lime caught. Net Lime Caught = 880 g − 320 g = 560 grams \text{Net Lime Caught} = 880\text{ g} - 320\text{ g} = 560\text{ grams} Net Lime Caught = 880 g − 320 g = 560 grams
Step 2: Determine delivery rate in grams per minute. Delivery Rate = 560 grams 4.0 minutes = 140.0 grams/min \text{Delivery Rate} = \frac{560\text{ grams}}{4.0\text{ minutes}} = 140.0\text{ grams/min} Delivery Rate = 4.0 minutes 560 grams = 140.0 grams/min
Step 3: Convert grams per minute to pounds per day. Feed Rate (lbs/day) = 140.0 g/min × 1 , 440 min/day 453.6 g/lb = 201 , 600 453.6 = 444.44 lbs/day ≈ 444 lbs/day \text{Feed Rate (lbs/day)} = \frac{140.0\text{ g/min} \times 1,440\text{ min/day}}{453.6\text{ g/lb}} = \frac{201,600}{453.6} = 444.44\text{ lbs/day} \approx 444\text{ lbs/day} Feed Rate (lbs/day) = 453.6 g/lb 140.0 g/min × 1 , 440 min/day = 453.6 201 , 600 = 444.44 lbs/day ≈ 444 lbs/day
5. Chlorine Demand, Residual, and Dosage Mass Balance
Chlorine added to water or wastewater does not remain entirely available as a free disinfectant. A portion is consumed immediately by inorganic reducing agents (ferrous iron F e 2 + Fe^{2+} F e 2 + , manganese M n 2 + Mn^{2+} M n 2 + , hydrogen sulfide H 2 S H_2S H 2 S , nitrite N O 2 − NO_2^- N O 2 − ) and organic compounds. The basic disinfection mass balance relationship is: Chlorine Dosage = Chlorine Demand + Chlorine Residual \text{Chlorine Dosage} = \text{Chlorine Demand} + \text{Chlorine Residual} Chlorine Dosage = Chlorine Demand + Chlorine Residual
Rearranging to determine demand or residual: Chlorine Demand = Chlorine Dosage − Chlorine Residual \text{Chlorine Demand} = \text{Chlorine Dosage} - \text{Chlorine Residual} Chlorine Demand = Chlorine Dosage − Chlorine Residual Chlorine Residual = Chlorine Dosage − Chlorine Demand \text{Chlorine Residual} = \text{Chlorine Dosage} - \text{Chlorine Demand} Chlorine Residual = Chlorine Dosage − Chlorine Demand
Where:
Dosage (mg/L): Total concentration of chlorine applied to the water by the feed system.
Demand (mg/L): The amount of chlorine consumed by chemical reactions and microbiological destruction during a defined contact period.
Residual (mg/L): The concentration of active chlorine remaining in the water at the end of the contact time. Chlorine residual is further divided into Free Residual (hypochlorous acid H O C l HOCl H OCl and hypochlorite ion O C l − OCl^- OC l − ) and Combined Residual (chloramines formed with ammonia).
Worked Example: Determining Chlorine Demand
Problem Statement: A surface water plant treats 5.0 MGD. The gas chlorinator feeds 160 pounds of chlorine gas per day. Effluent sampling after 45 minutes of contact chamber detention reveals a total chlorine residual of 0.9 mg/L. What is the chlorine demand of the water in mg/L?
Step 1: Calculate the applied chlorine dosage using the rearranged pounds formula. Dosage (mg/L) = Feed Rate (lbs/day) Flow (MGD) × 8.34 lbs/gal = 160 lbs/day 5.0 MGD × 8.34 lbs/gal = 160 41.7 = 3.837 mg/L ≈ 3.84 mg/L \text{Dosage (mg/L)} = \frac{\text{Feed Rate (lbs/day)}}{\text{Flow (MGD)} \times 8.34\text{ lbs/gal}} = \frac{160\text{ lbs/day}}{5.0\text{ MGD} \times 8.34\text{ lbs/gal}} = \frac{160}{41.7} = 3.837\text{ mg/L} \approx 3.84\text{ mg/L} Dosage (mg/L) = Flow (MGD) × 8.34 lbs/gal Feed Rate (lbs/day) = 5.0 MGD × 8.34 lbs/gal 160 lbs/day = 41.7 160 = 3.837 mg/L ≈ 3.84 mg/L
Step 2: Solve for chlorine demand. Demand (mg/L) = Dosage − Residual = 3.84 mg/L − 0.90 mg/L = 2.94 mg/L \text{Demand (mg/L)} = \text{Dosage} - \text{Residual} = 3.84\text{ mg/L} - 0.90\text{ mg/L} = 2.94\text{ mg/L} Demand (mg/L) = Dosage − Residual = 3.84 mg/L − 0.90 mg/L = 2.94 mg/L
6. Two-Normal Dilution & Solution Mixing Calculations
When preparing chemical solutions in day tanks or diluting stock reagents, operators apply the Two-Normal Dilution Equation . Because the absolute mass of active chemical solute remains unchanged when water is added, the product of initial concentration and volume equals the product of final concentration and volume: C 1 × V 1 = C 2 × V 2 C_1 \times V_1 = C_2 \times V_2 C 1 × V 1 = C 2 × V 2
Where:
C 1 = Concentration of stock / initial solution (%, mg/L, or normality) C_1 = \text{Concentration of stock / initial solution (\%, mg/L, or normality)} C 1 = Concentration of stock / initial solution (%, mg/L, or normality)
V 1 = Volume of stock solution required (gallons, liters, or mL) V_1 = \text{Volume of stock solution required (gallons, liters, or mL)} V 1 = Volume of stock solution required (gallons, liters, or mL)
C 2 = Concentration of target diluted solution (same units as C 1 ) C_2 = \text{Concentration of target diluted solution (same units as } C_1) C 2 = Concentration of target diluted solution (same units as C 1 )
V 2 = Total volume of target diluted solution (same units as V 1 ) V_2 = \text{Total volume of target diluted solution (same units as } V_1) V 2 = Total volume of target diluted solution (same units as V 1 )
Worked Example: Diluting Sodium Hypochlorite
Problem Statement: An operator must prepare 150 gallons of a 2.0% sodium hypochlorite feed solution in a chemical day tank from a 10.0% bulk hypochlorite stock. How many gallons of the 10.0% solution must be transferred to the day tank, and how many gallons of dilution water must be added?
Step 1: Identify known values.
C 1 = 10.0 % C_1 = 10.0\% C 1 = 10.0%
V 1 = ? V_1 = ? V 1 = ?
- C 2 = 2.0 % C_2 = 2.0\% C 2 = 2.0%
- V 2 = 150 gallons V_2 = 150\text{ gallons} V 2 = 150 gallons
Step 2: Solve for V 1 V_1 V 1 . V 1 = C 2 × V 2 C 1 = 2.0 % × 150 gallons 10.0 % = 300 10.0 = 30.0 gallons V_1 = \frac{C_2 \times V_2}{C_1} = \frac{2.0\% \times 150\text{ gallons}}{10.0\%} = \frac{300}{10.0} = 30.0\text{ gallons} V 1 = C 1 C 2 × V 2 = 10.0% 2.0% × 150 gallons = 10.0 300 = 30.0 gallons
Step 3: Calculate the volume of dilution water needed. Dilution Water Volume = V 2 − V 1 = 150 gallons − 30 gallons = 120.0 gallons \text{Dilution Water Volume} = V_2 - V_1 = 150\text{ gallons} - 30\text{ gallons} = 120.0\text{ gallons} Dilution Water Volume = V 2 − V 1 = 150 gallons − 30 gallons = 120.0 gallons
7. Common Mathematical Pitfalls in Chemical Feed
Multiplying by Purity Instead of Dividing: Multiplying by a decimal percentage reduces the chemical amount, which would severely underdose the treatment process. Always divide pure pounds by decimal purity: Commercial lbs = Pure lbs / Purity \text{Commercial lbs} = \text{Pure lbs} / \text{Purity} Commercial lbs = Pure lbs / Purity .
Omitting Specific Gravity in Liquid Calculations: Assuming liquid chemicals weigh 8.34 lbs/gal like pure water. A dense liquid chemical ( S G = 1.20 SG = 1.20 SG = 1.20 ) weighs 10.0 lbs/gal 10.0\text{ lbs/gal} 10.0 lbs/gal . Neglecting specific gravity introduces a 15% to 30% dosage error.
Entering Gallons per Day into the Pounds Formula: The pounds formula requires flow in Million Gallons per Day (MGD) . Entering 2 , 000 , 000 gpd 2,000,000\text{ gpd} 2 , 000 , 000 gpd instead of 2.0 MGD 2.0\text{ MGD} 2.0 MGD inflates the calculated chemical requirement by a factor of one million.
Confusing Chlorine Demand with Dosage: Dosage is what leaves the chemical feeder; demand is what is consumed by water impurities; residual is what is measured at the tap or outfall. Remember that demand can never exceed dosage unless the residual is zero.