Study guide
13.3 Pumping Math: Total Dynamic Head, Horsepower, Efficiency & Power Cost
Alabama Water/Wastewater Operator Certification Study Guide Exam
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: Alabama Regulations, Certification, Exams & Utility Administration
1.1 ADEM Division 335-10-1: Facility Classifications, Grades & Staffing Rules 1.2 Becoming Certified in Alabama: Exam Application, Operator Intern Status, Experience, Renewal & CEHs 1.3 Environmental Compliance, SDWA, Clean Water Act & NPDES Permits 1.4 Alabama's PSI-Delivered WPI Exams: Format, Grade Crosswalk & Need-to-Know Blueprints 1.5 ADEM Drinking-Water Operating Rules (Division 335-7): Control Tests, Residuals, Pressure, Cross-Connections & Records 1.6 Utility Administration: SOPs, Records, Security, Cybersecurity, Emergency Planning & Supervision
2 Chapter 2: Source Water, Wells, Coagulation, Filtration & Membranes
2.1 Source Water Hydrology, Groundwater vs. Surface Water & Protection 2.2 Coagulation Chemistry, Coagulants & Rapid Mixing Mechanics 2.3 Flocculation Basin Design, Clarification & Sedimentation 2.4 Granular Media Filtration, Head Loss & Backwash Protocols 2.5 Membrane Filtration: MF, UF, NF & RO Operation, Integrity Testing and Cleaning 2.6 Wells & Groundwater Systems: Construction, Pumps, Testing and Sanitary Protection (ADEM 335-7-5)
3 Chapter 3: Water Disinfection, Chemical Addition, Stabilization & Residuals
3.1 Chlorination Chemistry, Breakpoint Chlorination & Residuals 3.2 Disinfection Byproducts (DBPs), Stage 1/2 Rules & CT Compliance 3.3 Corrosion Control, Lead and Copper Rule & Fluoridation 3.4 Iron/Manganese Removal, Water Softening & Taste/Odor Control 3.5 Water Treatment Residuals: Sludge, Backwash Recycle & Plant Discharges
4 Chapter 4: Wastewater Preliminary & Primary Treatment
4.1 Wastewater Characteristics, Screening, Shredding & Grit Removal 4.2 Primary Sedimentation Basins, Scum Removal & Clarifier Performance
5 Chapter 5: Secondary Biological Treatment: Activated Sludge
5.1 Activated Sludge Microbiology, Basin Configurations & Aeration Systems 5.2 Process Control: F/M Ratio, MCRT/SRT & Sludge Settling Characteristics 5.3 Operational Troubleshooting (Bulking, Foaming, Pin Floc) & Process Modifications
6 Chapter 6: Fixed-Film Treatment, Lagoons, Nutrient Removal, Tertiary Filtration & Disinfection
6.1 Trickling Filters & Rotating Biological Contactors (RBCs) 6.2 Waste Stabilization Ponds, Aerated Lagoons & Alabama Grade I Lagoon Operations 6.3 Biological Nutrient Removal: Nitrification, Denitrification & Phosphorus Removal 6.4 Tertiary Filtration & Membrane Bioreactors (MBRs) 6.5 Wastewater Disinfection & Dechlorination: Chlorine, UV and Ozone
7 Chapter 7: Sludge Treatment, Biosolids & Odor Control
7.1 Sludge Thickening, Aerobic Digestion & Anaerobic Digestion 7.2 Mechanical Dewatering, Polymer Conditioning & EPA 503 Biosolids Regulations 7.3 Odor Control & Wastewater Chemical Addition
8 Chapter 8: Water Distribution Systems, Installation, Metering & Water Loss
8.1 Distribution Piping Materials, Valves & Finished Water Storage Facilities 8.2 Water Main Flushing, Disinfection Protocols (AWWA C651) & Water Quality Maintenance 8.3 Distribution Hydraulics, Pressure Control & Cross-Connection Prevention 8.4 Main & Service Installation, Tapping, Repair and Utility Locating (Alabama 811) 8.5 Meters, Water Loss Control, Asset Management & Customer Service
9 Chapter 9: Wastewater Collection Systems, Lift Stations & Sewer Maintenance
9.1 Gravity Collection Networks, Manhole Construction & Self-Cleansing Velocity Standards 9.2 Wastewater Lift Stations, Submersible Pumps, Force Mains & Inflow/Infiltration (I&I) 9.3 Sewer Cleaning, CCTV Inspection & SSO Response
10 Chapter 10: Laboratory Procedures, Sampling & Environmental Compliance
10.1 Drinking Water Laboratory Analysis: Turbidity, pH, Alkalinity & Coliform Testing 10.2 Wastewater Laboratory Testing: BOD5, COD, Total Suspended Solids & Settleability 10.3 Representative Sampling Protocols, Preservation, Chain of Custody & QA/QC
11 Chapter 11: Plant Equipment, Pumps, Motors & Instrumentation
11.1 Centrifugal and Positive Displacement Pumps: Operation, Cavitation & Packing/Seals 11.2 Electric Motors, Variable Frequency Drives, Flow Meters & SCADA Systems
12 Chapter 12: Safety: Chemicals, Confined Spaces & Field Hazards
12.1 Chemical Safety: Chlorine Gas Emergency Handling (Kits A & B) & Hydrogen Sulfide (H2S) Hazards 12.2 Permit-Required Confined Space Entry, Lockout/Tagout (LOTO) & Personal Protective Equipment 12.3 Field Safety: Work-Zone Traffic Control, Electrical Hazards, Fall Protection & Hazard Communication
13 Chapter 13: Water & Wastewater Mathematics: Hydraulics, Chemical Feed & Pumping
13.1 Flow Conversions, Geometry, Tank Volume & Detention Time Calculations 13.2 The Pounds Formula, Chemical Feed Rates & Solution Concentration Calculations 13.3 Pumping Math: Total Dynamic Head, Horsepower, Efficiency & Power Cost
14 Chapter 14: Water & Wastewater Mathematics: Treatment Process Calculations
14.1 Clarifier Surface Overflow Rate, Weir Loading & Granular Filter Loading Rates 14.2 Biological Calculations: F/M Ratio, MCRT Solids Balance & Sludge Volume Index (SVI)
13.3 Pumping Math: Total Dynamic Head, Horsepower, Efficiency & Power Cost
Key Takeaways Explain This Topic AI
Total dynamic head is the total static head plus friction and minor losses; from gauges it equals discharge pressure minus suction pressure, times 2.31 feet per psi.
Water horsepower equals flow in gpm times total dynamic head in feet, divided by 3,960.
Brake horsepower equals water horsepower divided by pump efficiency, and motor input horsepower equals brake horsepower divided by motor efficiency.
One horsepower equals 0.746 kilowatt, and daily power cost equals kilowatts times hours of operation times the cost per kilowatt-hour.
A wet-well drawdown test measures pumping rate as the volume drawn down divided by the time, plus inflow if inflow continues during the test.
Last updated: October 2026
13.3 Pumping Math: Total Dynamic Head, Horsepower, Efficiency & Power Cost
Pumping is usually the largest electrical cost at a water or wastewater utility. WPI exams include pump and motor calculations in the equipment content areas, and the WPI formula sheet lists the horsepower relationships. This section builds on the head and pressure conversions in Section 13.1 and the pump curves and affinity laws in Section 11.1.
Total Dynamic Head (TDH)
Total dynamic head is the total energy, in feet of water, that the pump must add: TDH = Total static head + Friction and minor losses ( + velocity head, usually small ) \text{TDH} = \text{Total static head} + \text{Friction and minor losses} \; (+ \text{velocity head, usually small}) TDH = Total static head + Friction and minor losses ( + velocity head, usually small )
Static suction lift : the pump sits above the water surface it draws from (the lift adds to the static head).
Static suction head : the water surface is above the pump centerline (it reduces the head the pump must add).
Static discharge head : height from the pump centerline to the discharge water surface.
Total static head is the difference in elevation between the discharge water surface and the source water surface.
Example 1. A pump lifts water from a wet well whose surface is 8 feet below the pump centerline and discharges into a tank whose surface is 92 feet above the pump. Friction and minor losses are 14 feet. Total static head is 8 + 92 = 100 8 + 92 = 100 8 + 92 = 100 feet, and TDH is 100 + 14 = 114 100 + 14 = 114 100 + 14 = 114 feet.
TDH from gauges. With a suction gauge and a discharge gauge at the same elevation: TDH (ft) = ( Discharge psi − Suction psi ) × 2.31 \text{TDH (ft)} = (\text{Discharge psi} - \text{Suction psi}) \times 2.31 TDH (ft) = ( Discharge psi − Suction psi ) × 2.31
If the discharge gauge reads 65 psi and the suction gauge reads 5 psi, TDH is ( 65 − 5 ) × 2.31 = 138.6 (65 - 5) \times 2.31 = 138.6 ( 65 − 5 ) × 2.31 = 138.6 feet. If the suction gauge shows a vacuum, convert it to a negative pressure (or add the equivalent lift) before subtracting.
Horsepower Chain Water horsepower (WHP) = Flow (gpm) × TDH (ft) 3,960 \text{Water horsepower (WHP)} = \frac{\text{Flow (gpm)} \times \text{TDH (ft)}}{3{,}960} Water horsepower (WHP) = 3 , 960 Flow (gpm) × TDH (ft) Brake horsepower (BHP) = WHP Pump efficiency \text{Brake horsepower (BHP)} = \frac{\text{WHP}}{\text{Pump efficiency}} Brake horsepower (BHP) = Pump efficiency WHP Motor horsepower (input) = BHP Motor efficiency \text{Motor horsepower (input)} = \frac{\text{BHP}}{\text{Motor efficiency}} Motor horsepower (input) = Motor efficiency BHP
Water horsepower is the useful work done on the water. The constant 3,960 comes from 33,000 ft-lb/min per horsepower divided by 8.34 lb/gal.
Brake horsepower is the power the motor must deliver to the pump shaft.
Motor input horsepower is the electrical power drawn.
Wire-to-water efficiency equals pump efficiency times motor efficiency.
Efficiencies are always used as decimals (78 percent becomes 0.78). Dividing by an efficiency always makes the number larger , which is a quick check that you used the right operation.
Power and Cost kW = Horsepower × 0.746 \text{kW} = \text{Horsepower} \times 0.746 kW = Horsepower × 0.746 Cost = kW × Hours of operation × Cost per kWh \text{Cost} = \text{kW} \times \text{Hours of operation} \times \text{Cost per kWh} Cost = kW × Hours of operation × Cost per kWh
Example 2. A high-service pump delivers 1,000 gpm against 120 feet of TDH. Pump efficiency is 78 percent and motor efficiency is 92 percent. The pump runs 16 hours a day and power costs 11 cents per kWh.
WHP = 1,000 × 120 ÷ 3,960 = 30.3 \text{WHP} = 1{,}000 \times 120 \div 3{,}960 = 30.3 WHP = 1 , 000 × 120 ÷ 3 , 960 = 30.3 hp
BHP = 30.3 ÷ 0.78 = 38.8 \text{BHP} = 30.3 \div 0.78 = 38.8 BHP = 30.3 ÷ 0.78 = 38.8 hp
Motor input = 38.8 ÷ 0.92 = 42.2 \text{Motor input} = 38.8 \div 0.92 = 42.2 Motor input = 38.8 ÷ 0.92 = 42.2 hp
kW = 42.2 × 0.746 = 31.5 \text{kW} = 42.2 \times 0.746 = 31.5 kW = 42.2 × 0.746 = 31.5 kW
Daily energy is 31.5 × 16 = 504 31.5 \times 16 = 504 31.5 × 16 = 504 kWh, which costs about 55 dollars and 44 cents per day at 11 cents per kWh.
Wire-to-water efficiency is 0.78 × 0.92 = 0.718 0.78 \times 0.92 = 0.718 0.78 × 0.92 = 0.718 , or about 72 percent. Raising pump efficiency by rebuilding worn wear rings (Section 11.1) or running closer to the best efficiency point lowers this cost directly.
Pumping Rate from a Wet-Well Drawdown Test
When no flow meter is available, operators time the drop in wet-well level.
Example 3 (inflow stopped). A circular wet well is 8 feet in diameter. With the influent valve closed, the pump lowers the level 2.0 feet in 3.0 minutes. Volume = 0.785 × 8 2 × 2.0 × 7.48 = 751.6 gal \text{Volume} = 0.785 \times 8^2 \times 2.0 \times 7.48 = 751.6\text{ gal} Volume = 0.785 × 8 2 × 2.0 × 7.48 = 751.6 gal Pump rate = 751.6 gal 3.0 min = 250.5 gpm \text{Pump rate} = \frac{751.6\text{ gal}}{3.0\text{ min}} = 250.5\text{ gpm} Pump rate = 3.0 min 751.6 gal = 250.5 gpm
Example 4 (inflow continuing). If inflow cannot be stopped, measure the inflow first by timing the rise with the pump off, then time the drawdown with the pump on. The pump rate equals the drawdown rate plus the inflow rate. If the level rises at a rate equal to 60 gpm with the pump off, and the drawdown with the pump on equals 190 gpm, the pump delivers 190 + 60 = 250 190 + 60 = 250 190 + 60 = 250 gpm.
Quick Reference
- Quantity Formula
- Head from pressure ft = psi x 2.31
- Water horsepower gpm x TDH / 3,960
- Brake horsepower WHP / pump efficiency
- Motor horsepower BHP / motor efficiency
- Kilowatts hp x 0.746
- Energy cost kW x hours x cost per kWh
- Pump rate by drawdown gallons drawn down / minutes (+ inflow)