Study guide

7.3 Odor Control & Wastewater Chemical Addition

Alabama Water/Wastewater Operator Certification Study Guide Exam

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: Alabama Regulations, Certification, Exams & Utility Administration

1.1 ADEM Division 335-10-1: Facility Classifications, Grades & Staffing Rules 1.2 Becoming Certified in Alabama: Exam Application, Operator Intern Status, Experience, Renewal & CEHs 1.3 Environmental Compliance, SDWA, Clean Water Act & NPDES Permits 1.4 Alabama's PSI-Delivered WPI Exams: Format, Grade Crosswalk & Need-to-Know Blueprints 1.5 ADEM Drinking-Water Operating Rules (Division 335-7): Control Tests, Residuals, Pressure, Cross-Connections & Records 1.6 Utility Administration: SOPs, Records, Security, Cybersecurity, Emergency Planning & Supervision

2 Chapter 2: Source Water, Wells, Coagulation, Filtration & Membranes

2.1 Source Water Hydrology, Groundwater vs. Surface Water & Protection 2.2 Coagulation Chemistry, Coagulants & Rapid Mixing Mechanics 2.3 Flocculation Basin Design, Clarification & Sedimentation 2.4 Granular Media Filtration, Head Loss & Backwash Protocols 2.5 Membrane Filtration: MF, UF, NF & RO Operation, Integrity Testing and Cleaning 2.6 Wells & Groundwater Systems: Construction, Pumps, Testing and Sanitary Protection (ADEM 335-7-5)

3 Chapter 3: Water Disinfection, Chemical Addition, Stabilization & Residuals

3.1 Chlorination Chemistry, Breakpoint Chlorination & Residuals 3.2 Disinfection Byproducts (DBPs), Stage 1/2 Rules & CT Compliance 3.3 Corrosion Control, Lead and Copper Rule & Fluoridation 3.4 Iron/Manganese Removal, Water Softening & Taste/Odor Control 3.5 Water Treatment Residuals: Sludge, Backwash Recycle & Plant Discharges

4 Chapter 4: Wastewater Preliminary & Primary Treatment

4.1 Wastewater Characteristics, Screening, Shredding & Grit Removal 4.2 Primary Sedimentation Basins, Scum Removal & Clarifier Performance

5 Chapter 5: Secondary Biological Treatment: Activated Sludge

5.1 Activated Sludge Microbiology, Basin Configurations & Aeration Systems 5.2 Process Control: F/M Ratio, MCRT/SRT & Sludge Settling Characteristics 5.3 Operational Troubleshooting (Bulking, Foaming, Pin Floc) & Process Modifications

6 Chapter 6: Fixed-Film Treatment, Lagoons, Nutrient Removal, Tertiary Filtration & Disinfection

6.1 Trickling Filters & Rotating Biological Contactors (RBCs) 6.2 Waste Stabilization Ponds, Aerated Lagoons & Alabama Grade I Lagoon Operations 6.3 Biological Nutrient Removal: Nitrification, Denitrification & Phosphorus Removal 6.4 Tertiary Filtration & Membrane Bioreactors (MBRs) 6.5 Wastewater Disinfection & Dechlorination: Chlorine, UV and Ozone

7 Chapter 7: Sludge Treatment, Biosolids & Odor Control

7.1 Sludge Thickening, Aerobic Digestion & Anaerobic Digestion 7.2 Mechanical Dewatering, Polymer Conditioning & EPA 503 Biosolids Regulations 7.3 Odor Control & Wastewater Chemical Addition

8 Chapter 8: Water Distribution Systems, Installation, Metering & Water Loss

8.1 Distribution Piping Materials, Valves & Finished Water Storage Facilities 8.2 Water Main Flushing, Disinfection Protocols (AWWA C651) & Water Quality Maintenance 8.3 Distribution Hydraulics, Pressure Control & Cross-Connection Prevention 8.4 Main & Service Installation, Tapping, Repair and Utility Locating (Alabama 811) 8.5 Meters, Water Loss Control, Asset Management & Customer Service

9 Chapter 9: Wastewater Collection Systems, Lift Stations & Sewer Maintenance

9.1 Gravity Collection Networks, Manhole Construction & Self-Cleansing Velocity Standards 9.2 Wastewater Lift Stations, Submersible Pumps, Force Mains & Inflow/Infiltration (I&I) 9.3 Sewer Cleaning, CCTV Inspection & SSO Response

10 Chapter 10: Laboratory Procedures, Sampling & Environmental Compliance

10.1 Drinking Water Laboratory Analysis: Turbidity, pH, Alkalinity & Coliform Testing 10.2 Wastewater Laboratory Testing: BOD5, COD, Total Suspended Solids & Settleability 10.3 Representative Sampling Protocols, Preservation, Chain of Custody & QA/QC

11 Chapter 11: Plant Equipment, Pumps, Motors & Instrumentation

11.1 Centrifugal and Positive Displacement Pumps: Operation, Cavitation & Packing/Seals 11.2 Electric Motors, Variable Frequency Drives, Flow Meters & SCADA Systems

12 Chapter 12: Safety: Chemicals, Confined Spaces & Field Hazards

12.1 Chemical Safety: Chlorine Gas Emergency Handling (Kits A & B) & Hydrogen Sulfide (H2S) Hazards 12.2 Permit-Required Confined Space Entry, Lockout/Tagout (LOTO) & Personal Protective Equipment 12.3 Field Safety: Work-Zone Traffic Control, Electrical Hazards, Fall Protection & Hazard Communication

13 Chapter 13: Water & Wastewater Mathematics: Hydraulics, Chemical Feed & Pumping

13.1 Flow Conversions, Geometry, Tank Volume & Detention Time Calculations 13.2 The Pounds Formula, Chemical Feed Rates & Solution Concentration Calculations 13.3 Pumping Math: Total Dynamic Head, Horsepower, Efficiency & Power Cost

14 Chapter 14: Water & Wastewater Mathematics: Treatment Process Calculations

14.1 Clarifier Surface Overflow Rate, Weir Loading & Granular Filter Loading Rates 14.2 Biological Calculations: F/M Ratio, MCRT Solids Balance & Sludge Volume Index (SVI)

7.3 Odor Control & Wastewater Chemical Addition

Key Takeaways Explain This Topic AI

Most wastewater odor comes from hydrogen sulfide and other reduced sulfur compounds formed when wastewater turns septic in force mains, wet wells, primary clarifiers and sludge handling.

Calcium nitrate prevents sulfide formation, iron salts precipitate sulfide as iron sulfide, magnesium hydroxide raises pH so sulfide stays dissolved, and peroxide or hypochlorite oxidize sulfide.

Caustic and hypochlorite wet scrubbers remove hydrogen sulfide and mercaptans, while acid scrubbers remove ammonia and amines.

Biofilters need moist media (about 40 to 60 percent moisture) and enough empty-bed contact time, and their media turns acidic as hydrogen sulfide is oxidized to sulfuric acid.

Nitrifying plants often feed lime, caustic, magnesium hydroxide or sodium bicarbonate to keep about 50 to 100 mg/L of alkalinity in the effluent.

Last updated: October 2026

7.3 Odor Control & Wastewater Chemical Addition

Odor complaints are one of the fastest ways for a wastewater utility to lose public trust, and the same septic conditions that cause odor also corrode concrete and endanger workers (Sections 9.1 and 12.1). The WPI Wastewater Treatment outlines list odor control devices (biofilters, scrubbers) as equipment and chemical dosing for coagulation/flocculation, nutrient removal or enhancement, odor control and pH adjustment as a treatment process.

Where Odors Come From

Compound Odor Common sources

Hydrogen sulfide ( H 2 S \text{H}_2\text{S} H 2 ​ S ) Rotten eggs Septic force mains, wet wells, headworks turbulence, primary clarifiers

  • Mercaptans and other organic sulfur compounds Rotten cabbage, skunk Septic sludge, dewatering, sludge storage
  • Ammonia and amines Sharp, fishy Sludge processing, lime stabilization, composting
  • Volatile fatty acids, indole and skatole Rancid, fecal Septic sludge, anaerobic zones

Odors rise sharply wherever septic wastewater is turbulent : force main discharges, drop structures, channels with free falls, grit chambers and splashing weirs release dissolved gases into the air.

Preventing Sulfide in the Collection System

Sulfide forms when sulfate-reducing bacteria in slime layers work without oxygen, especially in long force mains with long detention times and warm temperatures, which describes much of Alabama for most of the year.

Calcium nitrate supplies nitrate as an electron acceptor, so bacteria use nitrate instead of sulfate and sulfide is not produced.

Iron salts (ferrous or ferric chloride) react with dissolved sulfide to form insoluble iron sulfide . The theoretical iron dose is about 1.74 mg of iron per mg of sulfide, and practical doses are higher.

Magnesium hydroxide raises pH toward about 8.5, keeping sulfide in the non-volatile HS − \text{HS}^- HS − form so less hydrogen sulfide gas escapes.

Oxidants such as hydrogen peroxide or sodium hypochlorite destroy sulfide already formed; they work fast but must be dosed close to the odor point.

Air or oxygen injection keeps force mains aerobic.

Periodic caustic slug dosing at very high pH can strip slime layers that produce sulfide.

Worked example. A force main carries 0.80 MGD with 5.0 mg/L of dissolved sulfide to remove. Using the theoretical ratio of 1.74 and a practical factor of 2: Fe dose = 5.0 × 1.74 × 2 = 17.4 mg/L as Fe \text{Fe dose} = 5.0 \times 1.74 \times 2 = 17.4\text{ mg/L as Fe} Fe dose = 5.0 × 1.74 × 2 = 17.4 mg/L as Fe Fe feed = 0.80 × 17.4 × 8.34 = 116 lb/day as Fe \text{Fe feed} = 0.80 \times 17.4 \times 8.34 = 116\text{ lb/day as Fe} Fe feed = 0.80 × 17.4 × 8.34 = 116 lb/day as Fe

The feed of commercial ferrous chloride solution is then found from its iron content per gallon.

Controlling Odors at the Plant

Keep it fresh. Pump primary sludge often enough to prevent septic blankets (Section 4.2), avoid long storage of raw sludge and keep wet wells and channels free of deposits.

Reduce turbulence at drops and weirs where possible.

Cover and ventilate the strongest sources and send the foul air to treatment.

Treating Foul Air

Wet chemical scrubbers. Foul air rises through a packed tower against a recirculated scrubbing solution.

Caustic (sodium hydroxide) with sodium hypochlorite absorbs and oxidizes hydrogen sulfide and mercaptans . Operators control pH (commonly about 9.5 to 11) and oxidation-reduction potential , watch for scaling and keep chemical feeds and blowdown in balance.

Acid (sulfuric acid) scrubbers remove ammonia and amines , which are basic gases.

Biofilters. Foul air passes slowly through a bed of moist organic media such as wood chips or compost, where bacteria oxidize odor compounds.

Keep the media moist (roughly 40 to 60 percent moisture) with irrigation; dry media cracks and channels.

Monitor media pH . Bacteria oxidize hydrogen sulfide to sulfuric acid, so the media becomes acidic over time; very low pH slows treatment and calls for washing or media replacement.

Provide adequate empty-bed contact time (EBCT) , commonly tens of seconds to a minute or more: EBCT = Media volume (ft 3 ) Airflow (ft 3 /min) \text{EBCT} = \frac{\text{Media volume (ft}^3)}{\text{Airflow (ft}^3\text{/min)}} EBCT = Airflow (ft 3 /min) Media volume (ft 3 ) ​

For a 40 ft by 30 ft bed with 4 ft of media (4,800 ft³) receiving 6,000 cfm, EBCT is 4,800 ÷ 6,000 = 0.8 4{,}800 \div 6{,}000 = 0.8 4 , 800 ÷ 6 , 000 = 0.8 minute, or 48 seconds.

Biotrickling filters use inert media with recirculated, nutrient-fed water. Activated carbon adsorbers (often impregnated for hydrogen sulfide) polish low-concentration air; operators track breakthrough and replace carbon on schedule.

Chemical Addition in the Treatment Process

Purpose Common chemicals Operating notes

pH and alkalinity for nitrification Lime, caustic soda, magnesium hydroxide, sodium bicarbonate Nitrification destroys about 7.14 mg/L of alkalinity per mg/L of ammonia-nitrogen; keep about 50 to 100 mg/L residual alkalinity

Carbon for denitrification Methanol or commercial carbon sources Feed to anoxic zones; overfeeding raises effluent BOD

  • Phosphorus removal Alum, ferric chloride, sodium aluminate Consumes alkalinity and adds sludge
  • Settling aid Cationic or anionic polymer Jar test the dose; overdosing can foul membranes and filters
  • Nutrient deficiency (industrial wastes) Urea, ammonia, phosphoric acid Restore roughly 100:5:1 BOD:N:P
  • Chemical Handling Rules

Store incompatible chemicals apart: hypochlorite must never contact acids or ammonia compounds , and bisulfite or other reducing agents must be kept away from hypochlorite.

Provide secondary containment sized for the largest tank, label lines and tanks, and keep Safety Data Sheets current (Section 12.3).

Verify each delivery against the order and certificate of analysis before unloading.