Study guide
2.2 Coagulation Chemistry, Coagulants & Rapid Mixing Mechanics
Alabama Water/Wastewater Operator Certification Study Guide Exam
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: Alabama Regulations, Certification, Exams & Utility Administration
1.1 ADEM Division 335-10-1: Facility Classifications, Grades & Staffing Rules 1.2 Becoming Certified in Alabama: Exam Application, Operator Intern Status, Experience, Renewal & CEHs 1.3 Environmental Compliance, SDWA, Clean Water Act & NPDES Permits 1.4 Alabama's PSI-Delivered WPI Exams: Format, Grade Crosswalk & Need-to-Know Blueprints 1.5 ADEM Drinking-Water Operating Rules (Division 335-7): Control Tests, Residuals, Pressure, Cross-Connections & Records 1.6 Utility Administration: SOPs, Records, Security, Cybersecurity, Emergency Planning & Supervision
2 Chapter 2: Source Water, Wells, Coagulation, Filtration & Membranes
2.1 Source Water Hydrology, Groundwater vs. Surface Water & Protection 2.2 Coagulation Chemistry, Coagulants & Rapid Mixing Mechanics 2.3 Flocculation Basin Design, Clarification & Sedimentation 2.4 Granular Media Filtration, Head Loss & Backwash Protocols 2.5 Membrane Filtration: MF, UF, NF & RO Operation, Integrity Testing and Cleaning 2.6 Wells & Groundwater Systems: Construction, Pumps, Testing and Sanitary Protection (ADEM 335-7-5)
3 Chapter 3: Water Disinfection, Chemical Addition, Stabilization & Residuals
3.1 Chlorination Chemistry, Breakpoint Chlorination & Residuals 3.2 Disinfection Byproducts (DBPs), Stage 1/2 Rules & CT Compliance 3.3 Corrosion Control, Lead and Copper Rule & Fluoridation 3.4 Iron/Manganese Removal, Water Softening & Taste/Odor Control 3.5 Water Treatment Residuals: Sludge, Backwash Recycle & Plant Discharges
4 Chapter 4: Wastewater Preliminary & Primary Treatment
4.1 Wastewater Characteristics, Screening, Shredding & Grit Removal 4.2 Primary Sedimentation Basins, Scum Removal & Clarifier Performance
5 Chapter 5: Secondary Biological Treatment: Activated Sludge
5.1 Activated Sludge Microbiology, Basin Configurations & Aeration Systems 5.2 Process Control: F/M Ratio, MCRT/SRT & Sludge Settling Characteristics 5.3 Operational Troubleshooting (Bulking, Foaming, Pin Floc) & Process Modifications
6 Chapter 6: Fixed-Film Treatment, Lagoons, Nutrient Removal, Tertiary Filtration & Disinfection
6.1 Trickling Filters & Rotating Biological Contactors (RBCs) 6.2 Waste Stabilization Ponds, Aerated Lagoons & Alabama Grade I Lagoon Operations 6.3 Biological Nutrient Removal: Nitrification, Denitrification & Phosphorus Removal 6.4 Tertiary Filtration & Membrane Bioreactors (MBRs) 6.5 Wastewater Disinfection & Dechlorination: Chlorine, UV and Ozone
7 Chapter 7: Sludge Treatment, Biosolids & Odor Control
7.1 Sludge Thickening, Aerobic Digestion & Anaerobic Digestion 7.2 Mechanical Dewatering, Polymer Conditioning & EPA 503 Biosolids Regulations 7.3 Odor Control & Wastewater Chemical Addition
8 Chapter 8: Water Distribution Systems, Installation, Metering & Water Loss
8.1 Distribution Piping Materials, Valves & Finished Water Storage Facilities 8.2 Water Main Flushing, Disinfection Protocols (AWWA C651) & Water Quality Maintenance 8.3 Distribution Hydraulics, Pressure Control & Cross-Connection Prevention 8.4 Main & Service Installation, Tapping, Repair and Utility Locating (Alabama 811) 8.5 Meters, Water Loss Control, Asset Management & Customer Service
9 Chapter 9: Wastewater Collection Systems, Lift Stations & Sewer Maintenance
9.1 Gravity Collection Networks, Manhole Construction & Self-Cleansing Velocity Standards 9.2 Wastewater Lift Stations, Submersible Pumps, Force Mains & Inflow/Infiltration (I&I) 9.3 Sewer Cleaning, CCTV Inspection & SSO Response
10 Chapter 10: Laboratory Procedures, Sampling & Environmental Compliance
10.1 Drinking Water Laboratory Analysis: Turbidity, pH, Alkalinity & Coliform Testing 10.2 Wastewater Laboratory Testing: BOD5, COD, Total Suspended Solids & Settleability 10.3 Representative Sampling Protocols, Preservation, Chain of Custody & QA/QC
11 Chapter 11: Plant Equipment, Pumps, Motors & Instrumentation
11.1 Centrifugal and Positive Displacement Pumps: Operation, Cavitation & Packing/Seals 11.2 Electric Motors, Variable Frequency Drives, Flow Meters & SCADA Systems
12 Chapter 12: Safety: Chemicals, Confined Spaces & Field Hazards
12.1 Chemical Safety: Chlorine Gas Emergency Handling (Kits A & B) & Hydrogen Sulfide (H2S) Hazards 12.2 Permit-Required Confined Space Entry, Lockout/Tagout (LOTO) & Personal Protective Equipment 12.3 Field Safety: Work-Zone Traffic Control, Electrical Hazards, Fall Protection & Hazard Communication
13 Chapter 13: Water & Wastewater Mathematics: Hydraulics, Chemical Feed & Pumping
13.1 Flow Conversions, Geometry, Tank Volume & Detention Time Calculations 13.2 The Pounds Formula, Chemical Feed Rates & Solution Concentration Calculations 13.3 Pumping Math: Total Dynamic Head, Horsepower, Efficiency & Power Cost
14 Chapter 14: Water & Wastewater Mathematics: Treatment Process Calculations
14.1 Clarifier Surface Overflow Rate, Weir Loading & Granular Filter Loading Rates 14.2 Biological Calculations: F/M Ratio, MCRT Solids Balance & Sludge Volume Index (SVI)
2.2 Coagulation Chemistry, Coagulants & Rapid Mixing Mechanics
Key Takeaways Explain This Topic AI
Raw water colloidal particles remain stably suspended due to negative electrostatic surface charges, quantified by a negative zeta potential (typically -15 to -30 mV) that repels neighboring colloids.
Primary metallic coagulants (aluminum sulfate, ferric chloride, ferric sulfate, and polyaluminum chloride) destabilize colloids through double-layer compression, charge neutralization, and sweep flocculation.
Alum (Al2(SO4)3 · 14H2O) consumes natural bicarbonate alkalinity at a rate of approximately 0.5 mg/L of alkalinity as CaCO3 per 1.0 mg/L of commercial alum, depressing pH and necessitating supplemental base feed.
Rapid mixing requires high hydraulic or mechanical shear (G = 700 to 1,000+ s^-1) and brief detention times (1 to 30 seconds) to disperse coagulant micro-species before hydrolysis completes.
Synthetic polyelectrolytes (cationic, anionic, and nonionic polymers) act as coagulant aids or primary coagulants; overdosing cationic polymer causes charge reversal and restabilization.
Last updated: October 2026
2.2 Coagulation Chemistry, Coagulants & Rapid Mixing Mechanics
Quick Answer: Coagulation is the chemical process of destabilizing finely divided colloidal particles so they can agglomerate into settleable flocs. Natural raw water colloids carry negative electrical surface charges that prevent them from colliding, quantified by a negative zeta potential (typically − 15 to − 30 mV -15\text{ to }-30\text{ mV} − 15 to − 30 mV ). Primary coagulants carrying multi-valent positive charges ( Al 3 + \text{Al}^{3+} Al 3 + , Fe 3 + \text{Fe}^{3+} Fe 3 + ) are injected into a high-energy rapid mixer ( G = 700 − 1000 s − 1 G = 700-1000\text{ s}^{-1} G = 700 − 1000 s − 1 , 1-30 seconds) to neutralize surface charges, collapse the electrical double layer, and form sweep flocs.
Colloidal Physics & The Electrical Double Layer
Waterborne impurities fall into three broad physical size categories:
Suspended Solids: Particles > 1.0 μ m > 1.0\text{ }\mu\text{m} > 1.0 μ m (silt, fine sand, large bacteria) that settle under gravity if given sufficient quiescent settling time.
Colloidal Solutes: Particles ranging from 0.001 μ m 0.001\text{ }\mu\text{m} 0.001 μ m to 1.0 μ m 1.0\text{ }\mu\text{m} 1.0 μ m (clays, color-causing humic acids, viruses, protein macromolecules).
Dissolved Matter: Solutes < 0.001 μ m < 0.001\text{ }\mu\text{m} < 0.001 μ m (salts, simple sugars, small organic molecules).
Why Colloids Do Not Settle
Colloids cannot settle under gravity in conventional treatment timeframes. A fine clay colloid ( 0.1 μ m 0.1\text{ }\mu\text{m} 0.1 μ m ) would require an estimated 20 to 200 years to settle 1 foot in still water. Instead, colloids remain suspended indefinitely due to two interacting physical phenomena:
Brownian Motion: Continuous, random bombardment of sub-micron colloids by thermal kinetic movement of surrounding water molecules.
Electrostatic Repulsion: Natural colloids carry a net negative surface charge resulting from isomorphic substitution within clay mineral crystal lattices (e.g., Al 3 + \text{Al}^{3+} Al 3 + substituting for Si 4 + \text{Si}^{4+} Si 4 + ) and ionization of functional carboxyl ( -COOH \text{-COOH} -COOH ) and phenolic hydroxyl ( -OH \text{-OH} -OH ) groups on humic matter.
The Electrical Double Layer (EDL) & Zeta Potential
Because the colloid has a negative surface charge, it attracts dissolved cations from the surrounding bulk solution, creating an Electrical Double Layer (EDL) :
Stern Layer (Fixed Layer): A rigid, dense layer of positive counter-ions held tightly against the colloid surface by electrostatic attraction.
Diffuse Layer: A secondary, looser zone extending into the bulk water where positive cations outnumber negative anions, with ion concentration tapering off to bulk solution levels.
Plane of Shear (Slipping Plane): The boundary separating ions that move along with the colloid through the water from the bulk fluid.
Zeta Potential ( Z P ZP ZP ): The electrical potential (voltage) measured at the slipping plane, expressed in millivolts ( mV \text{mV} mV ).
Natural raw surface waters typically display a zeta potential of − 15 mV to − 30 mV -15\text{ mV to }-30\text{ mV} − 15 mV to − 30 mV . Electrostatic repulsion prevents colloids from approaching closely enough for short-range attractive van der Waals forces to take effect.
Coagulation Objective: Reduce Zeta Potential to between − 5 mV and + 3 mV \text{Coagulation Objective: Reduce Zeta Potential to between } -5\text{ mV and } +3\text{ mV} Coagulation Objective: Reduce Zeta Potential to between − 5 mV and + 3 mV
When the zeta potential approaches zero, the electrostatic repulsive energy barrier collapses, allowing van der Waals forces to pull particles together upon contact. +------------------------------------------------------------------------+
- | ELECTRICAL DOUBLE LAYER DIAGRAM |
- | |
- | [ Colloidal Particle ] | Stern Layer | Diffuse Layer |
- | Negative Surface | Rigid Cations | Cations & Anions Graded |
- | ( - - - - ) | ( + + + + + ) | ( + - + + - + - ) |
- | | | |
- | | |-> Plane of Shear |
- | (Zeta Potential Point) |
- | |
- | Repulsive Energy Barrier collapses as ZP moves from -30 mV toward 0 |
- +------------------------------------------------------------------------+
- The Four Coagulation Mechanisms
Double-Layer Compression: High concentrations of inert electrolytes increase the ionic strength of the water, compressing the diffuse layer and reducing the distance over which repulsive forces act.
Charge Neutralization: Positively charged coagulant hydrolysis species (e.g., Al(OH) 2 + \text{Al(OH)}^{2+} Al(OH) 2 + , Al 8 (OH) 20 4 + \text{Al}_8\text{(OH)}_{20}^{4+} Al 8 (OH) 20 4 + , Fe(OH) 2 + \text{Fe(OH)}_2^+ Fe(OH) 2 + ) adsorb directly onto the negatively charged colloid surface, neutralizing the zeta potential.
Sweep Flocculation (Enmeshment): When metal coagulants are added in quantities exceeding the solubility limit of the metal hydroxide at operating pH, rapid precipitation of amorphous gelatinous metal hydroxides ( Al(OH) 3 (s) \text{Al(OH)}_3\text{(s)} Al(OH) 3 (s) or Fe(OH) 3 (s) \text{Fe(OH)}_3\text{(s)} Fe(OH) 3 (s) ) occurs. The expanding "sponge-like" hydroxide precipitate enmeshes and sweeps colloids out of suspension.
Interparticle Bridging: High-molecular-weight synthetic polymers bind to multiple colloids simultaneously, forming physical chemical bridges that span the electrostatic gap.
- Primary Chemical Coagulants
- 1. Aluminum Sulfate (Alum)
Alum ( Al 2 ( SO 4 ) 3 ⋅ 14 H 2 O \text{Al}_2(\text{SO}_4)_3 \cdot 14\text{H}_2\text{O} Al 2 ( SO 4 ) 3 ⋅ 14 H 2 O , molecular weight ≈ 594 g/mol \approx 594\text{ g/mol} ≈ 594 g/mol ) is the most widely utilized municipal coagulant. It is supplied as dry crystalline powder or as a liquid solution (typically 48 % to 50 % 48\%\text{ to }50\% 48% to 50% dry alum equivalent by weight, specific gravity 1.32 to 1.34 1.32\text{ to }1.34 1.32 to 1.34 , providing ≈ 5.4 lbs dry alum/gal \approx 5.4\text{ lbs dry alum/gal} ≈ 5.4 lbs dry alum/gal ).
Effective pH Range: 5.8 to 7.5 5.8\text{ to }7.5 5.8 to 7.5 (minimum aluminum solubility occurs at pH 6.0 to 6.2 \text{pH } 6.0\text{ to }6.2 pH 6.0 to 6.2 ). At pH < 5.5 \text{pH} < 5.5 pH < 5.5 or pH > 8.0 \text{pH} > 8.0 pH > 8.0 , aluminum remains dissolved as free Al 3 + \text{Al}^{3+} Al 3 + or aluminate ions ( Al(OH) 4 − \text{Al(OH)}_4^- Al(OH) 4 − ), escaping filters and causing post-precipitation in the distribution network.
Hydrolysis Reaction: Al 2 ( SO 4 ) 3 ⋅ 14 H 2 O + 6 H 2 O ⇌ 2 Al(OH) 3 (s) ↓ + 3 H 2 SO 4 + 14 H 2 O \text{Al}_2(\text{SO}_4)_3 \cdot 14\text{H}_2\text{O} + 6\text{H}_2\text{O} \rightleftharpoons 2\text{Al(OH)}_3\text{(s)} \downarrow + 3\text{H}_2\text{SO}_4 + 14\text{H}_2\text{O} Al 2 ( SO 4 ) 3 ⋅ 14 H 2 O + 6 H 2 O ⇌ 2 Al(OH) 3 (s) ↓ + 3 H 2 SO 4 + 14 H 2 O
Alkalinity Consumption by Alum
Alum requires alkalinity in the raw water to react and form aluminum hydroxide floc. It reacts with natural calcium bicarbonate alkalinity:
Al 2 ( SO 4 ) 3 ⋅ 14 H 2 O + 3 Ca(HCO 3 ) 2 → 2 Al(OH) 3 ↓ + 3 CaSO 4 + 6 CO 2 + 14 H 2 O \text{Al}_2(\text{SO}_4)_3 \cdot 14\text{H}_2\text{O} + 3\text{Ca(HCO}_3)_2 \to 2\text{Al(OH)}_3\downarrow + 3\text{CaSO}_4 + 6\text{CO}_2 + 14\text{H}_2\text{O} Al 2 ( SO 4 ) 3 ⋅ 14 H 2 O + 3 Ca(HCO 3 ) 2 → 2 Al(OH) 3 ↓ + 3 CaSO 4 + 6 CO 2 + 14 H 2 O
1.0 mg/L of commercial alum consumes ≈ 0.50 mg/L of alkalinity (as CaCO 3 ) \mathbf{1.0\text{ mg/L of commercial alum consumes } \approx 0.50\text{ mg/L of alkalinity (as }\text{CaCO}_3\mathbf{)}} 1.0 mg/L of commercial alum consumes ≈ 0.50 mg/L of alkalinity (as CaCO 3 )
If raw water natural alkalinity is insufficient ( < 30 to 45 mg/L < 30\text{ to }45\text{ mg/L} < 30 to 45 mg/L as CaCO 3 \text{CaCO}_3 CaCO 3 ), alum addition depresses pH below the optimum coagulation zone. This leads to incomplete flocculation, elevated settled water turbidity, dissolved aluminum breakthrough into finished water, and highly corrosive water.
2. Iron Salts (Ferric Coagulants)
Ferric Chloride ( FeCl 3 \text{FeCl}_3 FeCl 3 ): Available as a dark brown, highly corrosive, acidic liquid ( 35 % to 45 % 35\%\text{ to }45\% 35% to 45% , pH < 2 \text{pH} < 2 pH < 2 ). Effective across a broad pH range of 4.0 to 11.0 4.0\text{ to }11.0 4.0 to 11.0 . It consumes approximately 0.92 mg/L of alkalinity as CaCO 3 per 1.0 mg/L of dry FeCl 3 0.92\text{ mg/L of alkalinity as }\text{CaCO}_3\text{ per }1.0\text{ mg/L of dry }\text{FeCl}_3 0.92 mg/L of alkalinity as CaCO 3 per 1.0 mg/L of dry FeCl 3 .
Ferric Sulfate ( Fe 2 ( SO 4 ) 3 \text{Fe}_2(\text{SO}_4)_3 Fe 2 ( SO 4 ) 3 ): Available in dry or liquid form. Like ferric chloride, it produces dense, heavy ferric hydroxide ( Fe(OH) 3 \text{Fe(OH)}_3 Fe(OH) 3 ) flocs that settle more rapidly than alum flocs, particularly in cold water ( < 4 ∘ C < 4^\circ\text{C} < 4 ∘ C ). Effective for raw waters with high organic color.
3. Polyaluminum Chloride (PACl) & Pre-Hydrolyzed Salts
Polyaluminum Chloride ( Al n Cl ( 3 n − m ) ( OH ) m \text{Al}_n\text{Cl}_{(3n-m)}(\text{OH})_m Al n Cl ( 3 n − m ) ( OH ) m ) and Aluminum Chlorohydrate (ACH) are pre-polymerized aluminum salts with controlled basicity ( 50 % to 83 % 50\%\text{ to }83\% 50% to 83% ). Because the aluminum is already partially hydrolyzed into complex polymers:
They consume significantly less natural alkalinity than alum (often 50 % to 80 % 50\%\text{ to }80\% 50% to 80% less).
They cause minimal pH depression, frequently eliminating the need for lime or caustic soda.
They perform reliably in cold water where alum hydrolysis kinetics slow down.
They produce less chemical sludge volume by weight.
Supplemental Alkalinity & pH Conditioning Chemicals
Chemical Reagent Chemical Formula Commercial Form Alkalinity Equivalent
Hydrated Lime Ca(OH) 2 \text{Ca(OH)}_2 Ca(OH) 2 Dry powder ( 90 % 90\% 90% purity) 1.0 mg/L alum requires ≈ 0.38 mg/L lime 1.0\text{ mg/L alum requires } \approx 0.38\text{ mg/L lime} 1.0 mg/L alum requires ≈ 0.38 mg/L lime
Quicklime CaO \text{CaO} CaO Pebble / granular (requires slaker) 1.0 mg/L alum requires ≈ 0.28 mg/L CaO 1.0\text{ mg/L alum requires } \approx 0.28\text{ mg/L CaO} 1.0 mg/L alum requires ≈ 0.28 mg/L CaO
Soda Ash Na 2 CO 3 \text{Na}_2\text{CO}_3 Na 2 CO 3 Dense white powder / granular 1.0 mg/L alum requires ≈ 0.53 mg/L soda ash 1.0\text{ mg/L alum requires } \approx 0.53\text{ mg/L soda ash} 1.0 mg/L alum requires ≈ 0.53 mg/L soda ash
Caustic Soda NaOH \text{NaOH} NaOH 25 % or 50 % 25\%\text{ or }50\% 25% or 50% liquid solution 1.0 mg/L alum requires ≈ 0.40 mg/L 100% NaOH 1.0\text{ mg/L alum requires } \approx 0.40\text{ mg/L 100\% NaOH} 1.0 mg/L alum requires ≈ 0.40 mg/L 100% NaOH
Worked Engineering Problem: Alum Feed & Alkalinity Balance
Problem: A water plant treats a flow rate of 6.0 MGD 6.0\text{ MGD} 6.0 MGD with an alum dose of 34.0 mg/L 34.0\text{ mg/L} 34.0 mg/L . The raw water natural alkalinity is 28.0 mg/L 28.0\text{ mg/L} 28.0 mg/L as CaCO 3 \text{CaCO}_3 CaCO 3 . The target finished water alkalinity entering the distribution system must be maintained at a minimum of 25.0 mg/L 25.0\text{ mg/L} 25.0 mg/L as CaCO 3 \text{CaCO}_3 CaCO 3 to prevent corrosion.
Calculate the daily dry alum requirement in pounds per day.
Determine the alkalinity consumed by the alum.
Calculate the required supplemental hydrated lime dosage ( mg/L \text{mg/L} mg/L ) and the total pounds of lime needed per day, assuming hydrated lime provides 1.35 mg/L of alkalinity as CaCO 3 per 1.0 mg/L of commercial lime 1.35\text{ mg/L of alkalinity as }\text{CaCO}_3\text{ per }1.0\text{ mg/L of commercial lime} 1.35 mg/L of alkalinity as CaCO 3 per 1.0 mg/L of commercial lime .
Step 1: Calculate Daily Alum Feed (Pounds Formula): Feed (lbs/day) = Flow (MGD) × Dosage (mg/L) × 8.34 lbs/gal \text{Feed (lbs/day)} = \text{Flow (MGD)} \times \text{Dosage (mg/L)} \times 8.34\text{ lbs/gal} Feed (lbs/day) = Flow (MGD) × Dosage (mg/L) × 8.34 lbs/gal Alum (lbs/day) = 6.0 MGD × 34.0 mg/L × 8.34 = 1 , 701.36 lbs/day \text{Alum (lbs/day)} = 6.0\text{ MGD} \times 34.0\text{ mg/L} \times 8.34 = 1,701.36\text{ lbs/day} Alum (lbs/day) = 6.0 MGD × 34.0 mg/L × 8.34 = 1 , 701.36 lbs/day
Step 2: Calculate Alkalinity Consumed by Alum: Alkalinity Consumed = 34.0 mg/L alum × 0.50 mg/L alk / mg/L alum = 17.0 mg/L as CaCO 3 \text{Alkalinity Consumed} = 34.0\text{ mg/L alum} \times 0.50\text{ mg/L alk / mg/L alum} = 17.0\text{ mg/L as CaCO}_3 Alkalinity Consumed = 34.0 mg/L alum × 0.50 mg/L alk / mg/L alum = 17.0 mg/L as CaCO 3
Step 3: Determine Residual Alkalinity Without Lime: Remaining Alkalinity = 28.0 mg/L (raw) − 17.0 mg/L (consumed) = 11.0 mg/L as CaCO 3 \text{Remaining Alkalinity} = 28.0\text{ mg/L (raw)} - 17.0\text{ mg/L (consumed)} = 11.0\text{ mg/L as CaCO}_3 Remaining Alkalinity = 28.0 mg/L (raw) − 17.0 mg/L (consumed) = 11.0 mg/L as CaCO 3
Step 4: Calculate Supplemental Alkalinity Deficit: Alkalinity Deficit = 25.0 mg/L (target) − 11.0 mg/L (remaining) = 14.0 mg/L as CaCO 3 \text{Alkalinity Deficit} = 25.0\text{ mg/L (target)} - 11.0\text{ mg/L (remaining)} = 14.0\text{ mg/L as CaCO}_3 Alkalinity Deficit = 25.0 mg/L (target) − 11.0 mg/L (remaining) = 14.0 mg/L as CaCO 3
Step 5: Calculate Lime Dose and Daily Pounds: Lime Dose (mg/L) = 14.0 mg/L alkalinity 1.35 mg/L alk / mg/L lime = 10.37 mg/L hydrated lime \text{Lime Dose (mg/L)} = \frac{14.0\text{ mg/L alkalinity}}{1.35\text{ mg/L alk / mg/L lime}} = 10.37\text{ mg/L hydrated lime} Lime Dose (mg/L) = 1.35 mg/L alk / mg/L lime 14.0 mg/L alkalinity = 10.37 mg/L hydrated lime Lime (lbs/day) = 6.0 MGD × 10.37 mg/L × 8.34 = 518.91 lbs/day \text{Lime (lbs/day)} = 6.0\text{ MGD} \times 10.37\text{ mg/L} \times 8.34 = 518.91\text{ lbs/day} Lime (lbs/day) = 6.0 MGD × 10.37 mg/L × 8.34 = 518.91 lbs/day
Rapid Mixing Hydraulics & Mechanics
The primary function of rapid mixing (flash mixing) is to instantaneously disperse the coagulant chemical throughout the entire raw water stream.
The Kinetics of Coagulant Hydrolysis
Hydrolysis reactions occur in fractions of a second:
Positively charged monomeric and polymeric intermediate aluminum species form within 0.01 to 0.1 seconds 0.01\text{ to }0.1\text{ seconds} 0.01 to 0.1 seconds .
Charge neutralization of colloids occurs within 0.1 to 1.0 seconds 0.1\text{ to }1.0\text{ seconds} 0.1 to 1.0 seconds .
If the coagulant is not dispersed into the raw water within this brief window, the intermediate species polymerize into neutral Al(OH) 3 (s) \text{Al(OH)}_3\text{(s)} Al(OH) 3 (s) precipitates without contacting colloids, wasting chemical.
Rapid Mixing Design Parameters
Detention Time ( t t t ): Extremely short, typically 1 to 30 seconds (never exceeding 60 seconds).
Velocity Gradient ( G G G ): A measure of hydraulic shear and mixing intensity: G = P μ V G = \sqrt{\frac{P}{\mu V}} G = μ V P where P P P is power dissipated ( ft ⋅ lb/s \text{ft}\cdot\text{lb/s} ft ⋅ lb/s or Watts), μ \mu μ is dynamic viscosity of water, and V V V is basin volume. For rapid mixing, design standards require: G = 700 s − 1 to 1 , 000 + s − 1 G = 700\text{ s}^{-1} \text{ to } 1,000+\text{ s}^{-1} G = 700 s − 1 to 1 , 000 + s − 1
Types of Rapid Mixers
Mechanical Impeller Mixers: High-speed vertical shaft mixers equipped with radial or axial flow turbines installed in small mixing chambers. Provide controllable mixing intensity but consume electrical power and require shaft seal maintenance.
In-Line Static Mixers: Fixed, twisted helical geometric elements fitted directly inside the raw water pipeline. As water flows through the elements, turbulent vortices continuously divide and recombine the stream. Extremely rapid ( < 2 seconds < 2\text{ seconds} < 2 seconds ), zero moving parts, but head loss increases with the square of the flow rate.
Hydraulic Mixers (Hydraulic Jumps): Coagulant injected directly into the turbulent standing wave of a Parshall flume or open channel weir drop. Energy is supplied entirely by gravitational head loss; mixing intensity varies with flow rate.
Coagulant Aids & Synthetic Polymers
Polyelectrolytes (polymers) are long-chain synthetic or natural organic macromolecules made of repeating monomer subunits. They serve three operational roles:
Primary Coagulant: High-charge-density, low-molecular-weight cationic polymers (e.g., polyDADMAC, Epi-DMA). They neutralize negative colloidal charges at low dosages ( 0.5 to 2.0 mg/L 0.5\text{ to }2.0\text{ mg/L} 0.5 to 2.0 mg/L ) without consuming alkalinity or altering pH.
Flocculant Aids (Coagulant Aids): High-molecular-weight, low-charge anionic or nonionic polymers . Added downstream of the primary coagulant (often at the end of rapid mix or in stage 1 flocculation) to bind micro-flocs into tough, dense macro-flocs via bridging.
Filter Aids: Ultra-low dosages ( 0.01 to 0.05 mg/L 0.01\text{ to }0.05\text{ mg/L} 0.01 to 0.05 mg/L ) added directly to filter influent to toughen floc against hydraulic shearing in the media bed.
Caution — Polymer Overdosing & Restabilization: Overdosing cationic polymer can flip the colloidal surface charge from negative to positive. The particles become positively charged, repel one another again, and undergo charge reversal restabilization . Water turns milky, floc formation ceases, settled turbidity spikes, and filters blind rapidly.
Process Control: Jar Testing Protocol
The Jar Test is the standard laboratory method used to determine the optimal coagulant type, chemical dosage, rapid mix intensity, and coagulation pH. +------------------------------------------------------------------------+
- | JAR TEST PROCEDURE |
- | |
- | 1. Fill six 1-liter (or 2-liter) Gator beakers with fresh raw water |
- | 2. Dose varying coagulant concentrations (e.g., 10, 20, 30, 40, 50) |
- | 3. Flash Mix: 100 to 150 rpm for 1 minute (Simulate Rapid Mix) |
- | 4. Flocculation: 30 rpm for 20 minutes (Tapered shear simulation) |
- | 5. Settling: 0 rpm for 15 to 30 minutes (Observe floc settling rate) |
- | 6. Withdraw supernatant 2 inches below surface; measure NTU and pH |
- | 7. Select dosage yielding lowest turbidity with lowest chemical cost |
- +------------------------------------------------------------------------+
- Operational Troubleshooting Matrix: Coagulation Anomalies
Symptom / Observation Root Cause Diagnostic Check Operator Corrective Action
Settled water turbidity elevated; floc in rapid mix is pinpoint and fragile Coagulant underdose or insufficient alkalinity depressing pH Check jar test curve; test raw vs. mixed water pH and alkalinity Increase coagulant dose; feed lime/soda ash to raise coagulation pH to 6.0 − 6.8 6.0-6.8 6.0 − 6.8
Water in rapid mix appears cloudy/milky; no floc forms; filters blind Coagulant or polymer overdose causing charge reversal Measure zeta potential or perform multi-jar test with lower doses Immediately decrease coagulant or polymer feed rate
Floc settles extremely slowly during winter months ( < 4 ∘ C < 4^\circ\text{C} < 4 ∘ C ) Cold water increases viscosity, slowing chemical hydrolysis kinetics Check raw water temperature and compare settled turbidity Switch to or supplement with PACl or ferric salts; add coagulant aid polymer
Chemical feed pump stroke set correctly but dry chemical feed hopper empty Bridging or rat-holing in dry chemical hopper Visual inspection of feed hopper; verify chemical weight loss scale Clear blockage using mechanical vibrator or hopper paddle; inspect dehumidifier