Study guide
2.5 Membrane Filtration: MF, UF, NF & RO Operation, Integrity Testing and Cleaning
Alabama Water/Wastewater Operator Certification Study Guide Exam
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: Alabama Regulations, Certification, Exams & Utility Administration
1.1 ADEM Division 335-10-1: Facility Classifications, Grades & Staffing Rules 1.2 Becoming Certified in Alabama: Exam Application, Operator Intern Status, Experience, Renewal & CEHs 1.3 Environmental Compliance, SDWA, Clean Water Act & NPDES Permits 1.4 Alabama's PSI-Delivered WPI Exams: Format, Grade Crosswalk & Need-to-Know Blueprints 1.5 ADEM Drinking-Water Operating Rules (Division 335-7): Control Tests, Residuals, Pressure, Cross-Connections & Records 1.6 Utility Administration: SOPs, Records, Security, Cybersecurity, Emergency Planning & Supervision
2 Chapter 2: Source Water, Wells, Coagulation, Filtration & Membranes
2.1 Source Water Hydrology, Groundwater vs. Surface Water & Protection 2.2 Coagulation Chemistry, Coagulants & Rapid Mixing Mechanics 2.3 Flocculation Basin Design, Clarification & Sedimentation 2.4 Granular Media Filtration, Head Loss & Backwash Protocols 2.5 Membrane Filtration: MF, UF, NF & RO Operation, Integrity Testing and Cleaning 2.6 Wells & Groundwater Systems: Construction, Pumps, Testing and Sanitary Protection (ADEM 335-7-5)
3 Chapter 3: Water Disinfection, Chemical Addition, Stabilization & Residuals
3.1 Chlorination Chemistry, Breakpoint Chlorination & Residuals 3.2 Disinfection Byproducts (DBPs), Stage 1/2 Rules & CT Compliance 3.3 Corrosion Control, Lead and Copper Rule & Fluoridation 3.4 Iron/Manganese Removal, Water Softening & Taste/Odor Control 3.5 Water Treatment Residuals: Sludge, Backwash Recycle & Plant Discharges
4 Chapter 4: Wastewater Preliminary & Primary Treatment
4.1 Wastewater Characteristics, Screening, Shredding & Grit Removal 4.2 Primary Sedimentation Basins, Scum Removal & Clarifier Performance
5 Chapter 5: Secondary Biological Treatment: Activated Sludge
5.1 Activated Sludge Microbiology, Basin Configurations & Aeration Systems 5.2 Process Control: F/M Ratio, MCRT/SRT & Sludge Settling Characteristics 5.3 Operational Troubleshooting (Bulking, Foaming, Pin Floc) & Process Modifications
6 Chapter 6: Fixed-Film Treatment, Lagoons, Nutrient Removal, Tertiary Filtration & Disinfection
6.1 Trickling Filters & Rotating Biological Contactors (RBCs) 6.2 Waste Stabilization Ponds, Aerated Lagoons & Alabama Grade I Lagoon Operations 6.3 Biological Nutrient Removal: Nitrification, Denitrification & Phosphorus Removal 6.4 Tertiary Filtration & Membrane Bioreactors (MBRs) 6.5 Wastewater Disinfection & Dechlorination: Chlorine, UV and Ozone
7 Chapter 7: Sludge Treatment, Biosolids & Odor Control
7.1 Sludge Thickening, Aerobic Digestion & Anaerobic Digestion 7.2 Mechanical Dewatering, Polymer Conditioning & EPA 503 Biosolids Regulations 7.3 Odor Control & Wastewater Chemical Addition
8 Chapter 8: Water Distribution Systems, Installation, Metering & Water Loss
8.1 Distribution Piping Materials, Valves & Finished Water Storage Facilities 8.2 Water Main Flushing, Disinfection Protocols (AWWA C651) & Water Quality Maintenance 8.3 Distribution Hydraulics, Pressure Control & Cross-Connection Prevention 8.4 Main & Service Installation, Tapping, Repair and Utility Locating (Alabama 811) 8.5 Meters, Water Loss Control, Asset Management & Customer Service
9 Chapter 9: Wastewater Collection Systems, Lift Stations & Sewer Maintenance
9.1 Gravity Collection Networks, Manhole Construction & Self-Cleansing Velocity Standards 9.2 Wastewater Lift Stations, Submersible Pumps, Force Mains & Inflow/Infiltration (I&I) 9.3 Sewer Cleaning, CCTV Inspection & SSO Response
10 Chapter 10: Laboratory Procedures, Sampling & Environmental Compliance
10.1 Drinking Water Laboratory Analysis: Turbidity, pH, Alkalinity & Coliform Testing 10.2 Wastewater Laboratory Testing: BOD5, COD, Total Suspended Solids & Settleability 10.3 Representative Sampling Protocols, Preservation, Chain of Custody & QA/QC
11 Chapter 11: Plant Equipment, Pumps, Motors & Instrumentation
11.1 Centrifugal and Positive Displacement Pumps: Operation, Cavitation & Packing/Seals 11.2 Electric Motors, Variable Frequency Drives, Flow Meters & SCADA Systems
12 Chapter 12: Safety: Chemicals, Confined Spaces & Field Hazards
12.1 Chemical Safety: Chlorine Gas Emergency Handling (Kits A & B) & Hydrogen Sulfide (H2S) Hazards 12.2 Permit-Required Confined Space Entry, Lockout/Tagout (LOTO) & Personal Protective Equipment 12.3 Field Safety: Work-Zone Traffic Control, Electrical Hazards, Fall Protection & Hazard Communication
13 Chapter 13: Water & Wastewater Mathematics: Hydraulics, Chemical Feed & Pumping
13.1 Flow Conversions, Geometry, Tank Volume & Detention Time Calculations 13.2 The Pounds Formula, Chemical Feed Rates & Solution Concentration Calculations 13.3 Pumping Math: Total Dynamic Head, Horsepower, Efficiency & Power Cost
14 Chapter 14: Water & Wastewater Mathematics: Treatment Process Calculations
14.1 Clarifier Surface Overflow Rate, Weir Loading & Granular Filter Loading Rates 14.2 Biological Calculations: F/M Ratio, MCRT Solids Balance & Sludge Volume Index (SVI)
2.5 Membrane Filtration: MF, UF, NF & RO Operation, Integrity Testing and Cleaning
Key Takeaways Explain This Topic AI
Microfiltration and ultrafiltration remove particles, bacteria and protozoa by size exclusion, while nanofiltration and reverse osmosis also remove dissolved hardness, organics and salts at much higher feed pressures.
Recovery is permeate flow divided by feed flow times 100, and salt rejection is one minus permeate concentration divided by feed concentration, times 100.
Rising transmembrane pressure at constant flux, or falling temperature-corrected specific flux, signals fouling and the need for a chemically enhanced backwash or clean-in-place.
Under 40 CFR 141.719, membrane units used for Cryptosporidium credit need a direct integrity test at least once a day and continuous indirect monitoring at least every 15 minutes.
If filtrate turbidity from a membrane unit exceeds 0.15 NTU for more than 15 minutes, a direct integrity test must be run immediately.
Last updated: October 2026
2.5 Membrane Filtration: MF, UF, NF & RO Operation, Integrity Testing and Cleaning
The WPI Water Treatment Class 1, 2 and 4 outlines all list membrane filtration under "monitor, evaluate and adjust" treatment processes, and the Class 4 outline adds membrane inspection and maintenance. Membranes are physical barriers, so they behave differently from granular media filters: removal depends on pore size and membrane integrity, and performance is tracked by pressure and flux rather than head loss alone.
The Four Pressure-Driven Membrane Classes
Class Typical removal Typical configuration Typical pressure
Microfiltration (MF) Particles, turbidity, bacteria, Giardia and Cryptosporidium Hollow fiber, pressurized or submerged Low (a few to about 30 psi transmembrane)
Ultrafiltration (UF) Everything MF removes, plus some viruses and large organic molecules Hollow fiber Low (similar to MF)
Nanofiltration (NF) Hardness, color, natural organic matter and DBP precursors, many dissolved ions Spiral wound Moderate (roughly 70 to 150 psi feed)
Reverse osmosis (RO) Nearly all dissolved salts, nitrate, arsenic, radionuclides, PFAS Spiral wound High (brackish water roughly 150 to 600 psi; seawater much higher)
MF and UF work by size exclusion and are used in place of, or after, conventional clarification. NF and RO work by diffusion through a dense membrane , so they remove dissolved substances and need pretreatment to protect the membrane.
Terms You Must Know
Feed enters the membrane, permeate (filtrate) passes through, and concentrate (reject or retentate) carries the removed material away.
Flux is permeate flow per unit of membrane area, usually in gallons per square foot per day (gfd) : Flux (gfd) = Permeate flow (gpd) Membrane area (ft 2 ) \text{Flux (gfd)} = \frac{\text{Permeate flow (gpd)}}{\text{Membrane area (ft}^2)} Flux (gfd) = Membrane area (ft 2 ) Permeate flow (gpd)
Transmembrane pressure (TMP) is the pressure difference across the membrane. At constant flux, rising TMP means fouling.
Specific flux is flux divided by TMP, corrected to a standard temperature (often 20°C) because water viscosity changes with temperature. Falling specific flux is the best fouling indicator.
Recovery is the fraction of feed that becomes permeate: Recovery (%) = Permeate flow Feed flow × 100 \text{Recovery (\%)} = \frac{\text{Permeate flow}}{\text{Feed flow}} \times 100 Recovery (%) = Feed flow Permeate flow × 100
Rejection (for RO and NF) is the fraction of a dissolved substance kept out of the permeate: Rejection (%) = ( 1 − C permeate C feed ) × 100 \text{Rejection (\%)} = \left(1 - \frac{C_{\text{permeate}}}{C_{\text{feed}}}\right) \times 100 Rejection (%) = ( 1 − C feed C permeate ) × 100
Log removal value (LRV) is log 10 ( C feed ) − log 10 ( C permeate ) \log_{10}(C_{\text{feed}}) - \log_{10}(C_{\text{permeate}}) lo g 10 ( C feed ) − lo g 10 ( C permeate ) .
Worked example. An RO train receives 500 gpm of feed and produces 375 gpm of permeate. Recovery is 375 ÷ 500 × 100 = 75 375 \div 500 \times 100 = 75 375 ÷ 500 × 100 = 75 percent, and the concentrate flow is 125 gpm. If feed total dissolved solids are 1,200 mg/L and permeate TDS is 30 mg/L, rejection is ( 1 − 30 ÷ 1,200 ) × 100 = 97.5 (1 - 30 \div 1{,}200) \times 100 = 97.5 ( 1 − 30 ÷ 1 , 200 ) × 100 = 97.5 percent. A UF plant producing 2.0 MGD across 50,000 ft² of membrane runs at 2,000,000 ÷ 50,000 = 40 2{,}000{,}000 \div 50{,}000 = 40 2 , 000 , 000 ÷ 50 , 000 = 40 gfd.
Fouling, Scaling and Pretreatment
Particulate fouling and biofouling coat the membrane surface; organic fouling comes from natural organic matter.
Scaling happens in RO and NF when dissolved salts such as calcium carbonate, calcium sulfate, barium sulfate or silica exceed solubility in the concentrate. Higher recovery concentrates salts further and raises scaling risk.
RO pretreatment commonly includes antiscalant feed, sometimes acid to lower pH, and cartridge filters (about 5 µm) just ahead of the high-pressure pumps. Many RO membranes are polyamide and are damaged by free chlorine , so chlorine is removed before the membrane when those membranes are used. The silt density index (SDI) test checks whether feed water is clean enough.
MF and UF Operation
Filtration cycle : typically 15 to 60 minutes.
Backwash : permeate is pushed backward through the fibers, often with air scour, to remove the cake layer.
Chemically enhanced backwash (CEB) : a short soak with chlorine, acid or caustic on a set schedule.
Clean-in-place (CIP) : when TMP reaches the manufacturer's limit or specific flux drops, the unit is taken offline and recirculated with cleaning solutions. High-pH caustic, often with chlorine, removes organic and biological foulants; low-pH acid (such as citric acid) removes inorganic scale, iron and manganese. Spent cleaning solutions must be neutralized and disposed of properly.
Integrity Testing under the LT2ESWTR
A broken fiber or failed O-ring lets pathogens bypass the barrier, so 40 CFR 141.719(b) sets integrity requirements for membranes used to earn Cryptosporidium removal credit:
Challenge testing establishes the removal efficiency the product can achieve.
Direct integrity testing must be done on each membrane unit at least once each day . The most common method is the pressure decay test : the wetted membrane is pressurized with air below its bubble point, and the rate of pressure loss is compared with a control limit. The test must be able to detect a breach of about 3 µm and verify the log removal credited.
Continuous indirect integrity monitoring , usually filtrate turbidity, must be recorded at least every 15 minutes . If filtrate turbidity exceeds 0.15 NTU for more than 15 minutes (two consecutive 15-minute readings), a direct integrity test must be performed immediately .
A unit that fails its control limit must be taken offline, the breach located (for example, by a bubble test on the module) and repaired by pinning or replacing fibers, and the unit retested before returning to service.
Post-Treatment and Concentrate
RO permeate is low in alkalinity and often carries dissolved carbon dioxide, so it is corrosive . Plants strip carbon dioxide in degasifiers, add alkalinity or caustic and a corrosion inhibitor, and often blend with treated bypass water before distribution. Concentrate and CIP wastes must go to an approved outlet, such as a sanitary sewer with the utility's approval or a permitted discharge (Section 3.5).